Some characteristics of the extruded scintillator.

Slides:



Advertisements
Similar presentations
R&D of Strip/Block Scintillators E.P.Jacosalem, S.Iba, N.Nakajima, H.Ono, A.L.Sanchez, A.M.Bacala & H.Miyata GLD Calorimeter Group 8 th ACFA Workshop on.
Advertisements

Comparison of 3 types of scintillator strips and 2 types of reflector films Miho NISHIYAMA Shinshu-U Light yield of 3 scintillator strips have been measured.
Bulk Scintillator Light Yield  We have prepared samples of bulk scintillator in order to study optimization for the MICE Fiber Tracker  pT(1.25%) + 3HF(.1-1%)
1 Cosmic Ray Test Stand with Scintillating Cells for Digital Hadron Calorimeter 06/23/2003 Kurt Francis - Northern Illinois University.
Problem with Square WLS Fiber Optic Cable A report on the observations of the physical response to square WLS fiber optic cable being applied and glued.
ANTEC EXTRUSION SIMULATION AND EXPERIMENTAL VALIDATION TO OPTIMIZE PRECISION DIE DESIGN by Srinivasa Rao Vaddiraju, M.
Tile-Fiber Optimization Vishnu V. Zutshi. Introduction Based on my conversations with Sasha and Manuel We already have intimations of tile-fiber system.
3/18/20021 Update on DHC elements testing. Task force: A. Dyshkant, M.Martin, V. Rykalin V. Rykalin.
Studies of Small Scintillating Cells with Modified Geometries Alexander Dyshkant for NICADD at NIU.
Performance of new strip scintillator Jungeun Lee, Jaeyun Choi, Kyungpook National University Minseok Park.
Fermi National Accelerator Laboratory EXTRUDED SCINTILLATOR STRIPS FOR MINERVA Anna Pla-Dalmau Fermilab Victor Rykalin NICADD, Northern Illinois University.
Jerry Blazey NIU/NICADD Towards A Scintillating (Semi)- Digital Hadron Calorimeter: Progress at NIU/NICADD Jerry Blazey Northern Illinois University.
Extruded Scintillating Tile Thickness Measurements A Preliminary Set of Measurements of the Extruded Scintillating Tiles from the NICADD Extruder.
Towards a Digital Hadron Calorimeter Vishnu V. Zutshi for NIU/NICADD Group.
T T20-00 Range Chart Control Limit Calculations Purpose Allows the analyst to calculate the "Range Chart" 3- sigma control limits based on table.
Beam test of scintillator strips Miho NISHIYAMA Shinshu University ・ scintillator strip calorimeter ・ Kuraray scintillator strips and KNU extruded ・ the.
THE FORWARD PROTON DETECTOR AT DZERO Gilvan Alves Lafex/CBPF 1) MOTIVATION 2) DETECTOR OPTIONS 3) FPD R&D 4) OUTLOOK Lishep 98 Lafex/CBPF Feb 17, 1998.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
1 NIU Integrated Readout Layer Kurt Francis NICADD Northern Illinois University March 19, 2014.
A General High Resolution Hadron Calorimeter using Scintillator Tiles Manuel I. Martin for NIU / NICADD Northern Illinois University Northern Illinois.
KEK BT Summary &Plan Shinshu University Miho Nishiyama.
Systematic Studies of Small Scintillators for New Sampling Calorimeter E.P.Jacosalem, S.Iba, N.Nakajima, H.Ono, A.L.Sanchez, A.M.Bacala & H.Miyata GLD.
CLAS12 forward detector: Pre-shower S. Stepanyan (JLAB) Collaborating institutions: YerPhI, JMU, OU, NSU, Orsay-IPN Concept, R&D, PED … CLAS12 Detector.
SCECAL progress report Tohru Takeshita (Shinshu) _DESY Beam Test summary _improvements for FNAL BT _FNAL module _current status at Fermilab.
Testing of C-layer bottom hole counters A.Ito, J.Negret, B.Satyanarayana.
PCAL Strips light transmission properties April 25, 2011April 26, 20111April 27,
1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
Scintillator tile – SiPM development at ITEP Michael Danilov, ITEP CALICE Meeting, Casablanca, 23 Sep 2010.
1 Hadronic calorimeter simulation S.Itoh, T.Takeshita ( Shinshu Univ.) GLC calorimeter group Contents - Comparison between Scintillator and Gas - Digital.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
06 FEB th ACFA Development of fine strip scintillator with extrusion technique SungHyun Chang, DongHee Kim, Jun Suhk Suh, Youngdo Oh, Daejung Kong,
ECFA-DESY, Praha 16/11/02 S. Nemecek: Tiles & fibres... Tile and fibre measurements (Tile HCAL) J. Cvach, S. Němeček Institute of Physics AS CR, Prague.
CLAS12 Pre-shower H. Voskanyan (YerPhI)  R&D: Test measurements  Prototype CLAS Collaboration, CLAS12 TWG Meeting February 28, 2007, JLAB.
Comparison of 3 types of scintillator strips Miho NISHIYAMA Shinshu-U Light yield of 3 scintillator strips have been measured using b-ray source. 1. fiber.
Gamma Detector of Plastic Scintillator Oct. 2, 2009 IP-BSM Group 1.
Short Summary of the Japan- Korea KNU Oct GLDCAL meeting S. Uozumi (Shinshu) 3 rd Japan-Korea joint meeting is held on Oct at Kyunpook.
Fermilab Summer Internship 2004 Eric Benjamín Téllez Ugalde Universidad Nacional Autónoma de México UNAM (National Autonomous University of Mexico)
DEVELOPMENT OF THE POLYSTYRENE SCINTILLATOR TECHNOLOGY AND PARTICLE DETECTORS ON THEIR BASES VLADIMIR RYKALIN IHEP, PROTVINO INSTR-14, NOVOSIBIRSK, 24.
Status Report of Tile Calorimeter at Korea Calorimeter meeting 2005/6/13 Youngdo Oh Kyungpook National University.
The reading is 7.38 mm. The reading is 7.72 mm.
10 mm is the same as... 1 cm. 20 mm is the same as... 2 cm.
Backward Calorimetry For SuperB
Date of download: 1/2/2018 Copyright © ASME. All rights reserved.
ILC Detector Activities in Korea
CLAS12 Forward Detector Element PCAL
SCINTILLATING DIGITAL HADRON CALORIMETER
Tail-Catcher/Muon Tracker Prototype
SCINTILLATOR HARDWARE
Extruded Scintillator for MINERVA Victor Rykalin
Vishnu V. Zutshi For the NICADD team.
Towards a Scintillator-based (semi)Digital HCal
Scintillator HCal R&D Update
ELJEN TECHNOLOGY SCINTILLATOR AND GLUE
RESPONSE OF CELLS WITH 3, 4, AND 5 MM THICKNESSES
Si PM , the first glance Victor Rykalin
12/7/2018 Irradiation plan Victor Rykalin Victor Rykalin.
Tadashi Nomura (Kyoto U), KRare05 at Frascati, Italy
Study of a Scintillating Digital Hadron Calorimeter Prototype
CELLS RESPONSE OF DIFFERENT COATING/WRAPPING
Random Sampling Spider Web
Vishnu V. Zutshi for NIU/NICADD
N vs. E 0.25mip threshold roughcut for SLAC 2/24/2019.
ACD transparency - gaps between tiles - holes in tile to attach them
MRS, TEST STAND, EXTRUDER NEWS Victor Rykalin
Test of the designed die
General Introduction to IFR
5/14/2019 Scintillator extrusion at FERMILAB (Joint FERMILAB-NICADD project) Victor Rykalin Victor Rykalin.
Extruded Scintillator for MINERVA Victor Rykalin
Towards a Scintillator-based (semi)Digital HCal
Presentation transcript:

Some characteristics of the extruded scintillator. 10/24/2019 Some characteristics of the extruded scintillator. Victor Rykalin Victor Rykalin

Content Introduction The results of measurements Summary 10/24/2019 Victor Rykalin

Introduction We are doing very well ! 10/24/2019 Victor Rykalin

Introduction part, some useful information We have 100*5mm^2 of 6 m long profile for analysis. Mechanical measurements (we did before, NICADD measurements). Light output uniformity (within one cell, WSU measurements). Light output measurements(over 6 m scintillator profile, FNAL-NICADD measurements). Light output measurements (comparison to cast scintillator, FNAL-NICADD measurements) 10/24/2019 Victor Rykalin

Mechanical measurements The result is based on P. Torres NICADD activity. 4.78  0.03 mm 20 cm 44 m 10/24/2019 Victor Rykalin

Light output uniformity of FNAL-NICADD scintillator (WSU measurements) 50 mm 50 mm Sr 90, 2 mm coll., 8 mm step, 56 points, sigma grooved fiber of =0.83 mm. Sigma ~ 2.2 % FNAL- NICADD 10/24/2019 Victor Rykalin

100*5 mm^2 scintillator 1. 2. 3. 4. Cells measurements How the measurements were performed ? 100*5 mm^2 scintillator 1. 2. 3. 4. Cells measurements Fluorescence measurements Light output measurements and selection of the scintillator for the cell fabrication Cells production, no wrapping. 10/24/2019 Victor Rykalin

Light output uniformity, 6 m. Bi 207 e- 0.975 MeV 7% kj 0.481 MeV 2% kikkkkjkjkj 1.047 MeV 2% 10/24/2019 Victor Rykalin

The results, uniformity over 6 m Each sample is 6 pieces of scintillator 19*19 mm^2 269.4  7.7 (~ 3%) 10/24/2019 Victor Rykalin

Distribution 10/24/2019 Victor Rykalin

Uniformity over 1 sample 10*10 cm^2 269 255 263.0  6.6 (~2.5 %) 10/24/2019 Victor Rykalin

The results, relative light output normalized to the 1 mm of scintillator thickness, bulk measurements, Ru106 BC404 3.25  0.22 BC408 2.70  0.15 F-NICADD 2.01  0.30 (~66% of BC408) averaged over 10 samples 10/24/2019 Victor Rykalin

Summary. When the extruder works properly for the scintillator bulk we have…. Thickness  ~ 0.6 % (4.78 mm) Uniformity LY  ~ 2.2 % (5*5 cm2 ) Uniformity LY  ~ 3 % (over 6 m) Uniformity LY  ~ 2.5 % (10*10 cm2) Light output 66 % of BC408 This is a starting point ! 10/24/2019 Victor Rykalin