A: ECMO circuit tubing with component pieces in place, configured with a centrifugal pump. A: ECMO circuit tubing with component pieces in place, configured.

Slides:



Advertisements
Similar presentations
Partial Pressures of O 2 and CO 2 Normal air pressure at sea level 760 mm Hg = 1 atm = kPa airtracheaalveoliartery vein PO
Advertisements

Today: and F 4/10 no class. M 4/13 class + movie at 7pm in WEL
Diversity… Gas exchange and Circulation
LABORATORY OF BIOLOGICAL STRUCTURE MECHANICS Technical and biological advances in ECMO New Perspective in ECMO 2012 III International.
Blood Vessels and the Heart
The Circulatory System.
The Closed Circulatory System Humans have a closed circulatory system, typical of all vertebrates, in which blood is confined to vessels and is distinct.
What is it? What are my responsibilities as baby nurse?
Circulatory and Respiratory Systems
The heart. The Heart Describe the role of the heart in the circulatory system. Explain the differences between arteries, veins and capillaries, by relating.
Definition of cardiovascular system The cardiovascular system is responsible for transporting nutrients and removing gaseous waste from the body. This.
The Respiratory System Group Members: Abby Ridley-Kerr Lia Kato Sasha Yovanovich Shelby LaRosa.
Blood Gas Analysis and Analyzer (BME Lab 2) Palestine Polytechnic University Engineering & Technology Collage Electrical &Computer Department Biomedical.
Artificial Lung Medical device to take over or supplement the respiratory function of the lungs. Used in cardiopulmonary bypass for open-heart surgery.
4.3.1 Heart of the Matter.
Who Wants to Be a Millionaire?
Circulation and Respiration
3.2 The Circulatory System
Circulatory System Delivers food and oxygen to body cells and carries carbon dioxide and other waste products away from body cells.
Science: Circulation Walt- Understand how gas exchange takes place
Ambulatory Extracorporeal Membrane Oxygenation
Circulation and Gas Exchange
Circulatory System Transport.
The Respiratory System and Its Regulation
Chapter 22 – The Respiratory System
Circulatory System.
Heart Lung Machine Lecture (9).
Checkpoint Define bulk flow and diffusion. Draw a diagram to enhance your answer. 2. Describe the process of ventilation including the appropriate volume.
The Circulatory System
Ambulatory Extracorporeal Membrane Oxygenation
Bell Ringer Period 1 Put belongings away Hw Due Thursday, Test Friday
Your Heart The size of your fist Mostly muscle 4 hollow chambers
Blood Flow Through the Heart
Transport and Diffusion of Gases
What can we do if our lungs stop working properly?
Xinran Lu, David K. Wood, John M. Higgins  Biophysical Journal 
External and Internal Respiration
Pre-Dissection Drawing Activity
The Spectrum mask incorporates the leak port into the circuit, whereas the Mirage mask incorporates the leak port into the mask. The Spectrum mask incorporates.
RESPIRATION AND CIRCULATION
O2 CO2 Gas Exchange Diffusion
The Circulatory System
3.2 The Circulatory System
Hybrid Extracorporeal Membrane Oxygenation Using Avalon Elite Double Lumen Cannula Ensures Adequate Heart/Brain Oxygen Supply  Ju Zhao, MD, Dongfang Wang,
The high flow nasal cannula (HFNC) system incorporated an air/O2 blender with a flow meter and a heated humidifier. The high flow nasal cannula (HFNC)
T h e H e a r t “The Pump of Life”.
Pumpless arterio-venous extracorporeal lung assist compared with veno-venous extracorporeal membrane oxygenation during experimental lung injury  R. Kopp,
Simulated screenshot of flow starvation in volume control continuous mandatory ventilation. Simulated screenshot of flow starvation in volume control continuous.
The peak flows (60 L/min) and flow patterns are the same for all the breaths. The peak flows (60 L/min) and flow patterns are the same for all the breaths.
Schematic drawing of alveolar sizes at upper (A), middle (B), and lower dependent (C) lung regions at end expiration and end inspiration. Schematic drawing.
Bland-Altman plots with exhaled VT difference plotted against the mean (displayed and pneumotachograph-measured) with and without sensor for method circuit.
Alveolar and airway CO2 during the ventilatory cycle: flow (upper graph) and mean alveolar and airway CO2 pressure scalars (lower graph). Alveolar and.
Diagram of venovenous extracorporeal membrane oxygenation (VV-ECMO) (A) and venoarterial ECMO (VA-ECMO) (B) and patient circulation. Diagram of venovenous.
The Boussignac continuous positive airway pressure (CPAP) is a small plastic cylinder that attaches to a face mask. The Boussignac continuous positive.
Control circuit for set-point or dual targeting schemes.
Assembly used to convert a standard ventilator to an intermittent mandatory ventilation circuit. Assembly used to convert a standard ventilator to an intermittent.
Renal replacement therapy using an in-line hemofilter during extracorporeal membrane oxygenation (ECMO). Renal replacement therapy using an in-line hemofilter.
Depiction of the highest oxygen-consuming and perfused organs in the body under resting conditions. Depiction of the highest oxygen-consuming and perfused.
Simulation-Based Postcardiotomy Extracorporeal Membrane Oxygenation Crisis Training for Thoracic Surgery Residents  Harold M. Burkhart, MD, Jeffrey B.
Plots of alveolar PO2, hemoglobin saturation, and alveolar PCO2 as a function of alveolar ventilation in a normal subject at sea level (inspired oxygen.
Components of a patient-triggered mechanical breath.
Pumpless extracorporeal gas exchange aiding central airway surgery
The Global Initiative for Chronic Obstructive Lung Disease (GOLD) ABCD scheme for classifying patients with COPD with separate appraisal of air-flow limitation.
Survival among subjects with COPD, under age 65 and with similar pulmonary function impairment, in the Nocturnal Oxygen Therapy Trial (NOTT)58 and Intermittent.
Experimental setup. Experimental setup. Each tested ventilator was connected to the TTL test lung via a ventilator circuit. An oxygen analyzer, a pressure.
Basic setup for high-flow nasal cannula oxygen delivery.
Renal replacement therapy (RRT) using RRT machine during extracorporeal membrane oxygenation (ECMO). Renal replacement therapy (RRT) using RRT machine.
Arterial blood gas measurement of oxygen tension.
Setup of the BiPAP Synchrony with an inspiratory filter and single-limb passive circuit, with the filter placed over the fixed leak to collect aerosol.
Presentation transcript:

A: ECMO circuit tubing with component pieces in place, configured with a centrifugal pump. A: ECMO circuit tubing with component pieces in place, configured with a centrifugal pump. Patient outflow tubing marked with blue tape (venous limb) draws deoxygenated blood from patient into the pump. Patient inflow tubing marked with red (arterial limb) tape returns oxygenate blood to the patient. This circuit is configured with a centrifugal pump interface. B: ECMO cart with all component pieces in place, configured with a rotary pump. C: Maquet Cardiohelp system. 1: Artificial lung (Maquet Quadrox) provides extracorporeal gas exchange. 2: External pump provides driving force for blood flow through the ECMO circuit. This can be either a centrifugal or rotary pump. The blood flow circuit tubing in A is configured for a centrifugal pump interface, whereas B depicts a rotary pump. 3: Blood parameter monitoring system (Temuro CDI) uses fluorescence sensors on the venous and arterial sides to monitor continuously pH, PCO2, PO2, oxygen saturation, hemoglobin/hematocrit, HCO3, and potassium. 4: Gas source delivers fresh medical gas (oxygen and air) modified by a flow meter and blender, shown in B, to the artificial lung via green tubing, shown in A. 5: Blood flow meter continuously monitors blood flow through the ECMO circuit via a sensor on the arterial limb tubing, serving as a direct measure of blood flow. 6: Bioconsole monitors blood flow generated by the external pump and the generated circuit pressures on the venous and arterial limbs. A display screen on the lower console displays flow characteristics generated by the external pump. 7: External heater uses a water bath to rewarm the blood while outside the patient to prevent hypothermia. 8: Maquet Cardiohelp system combines the artificial lung, a centrifugal pump, and bioconsole monitoring system into one unit, allowing smaller circuit priming volumes and a more streamlined overall circuit configuration. John C Lin Respir Care 2017;62:732-750 (c) 2012 by Daedalus Enterprises, Inc.