The esophageal balloon catheter is advanced to approximately 60 cm, so the catheter tip is in the stomach, confirmed by gently compressing the abdomen,

Slides:



Advertisements
Similar presentations
Effect of nasal positive expiratory pressure (PEP) on 6-min walk test (6MWT) distance and pre- to post-exercise increase in lung volumes in each individual.
Advertisements

The patient is being ventilated with 2 types of breaths.
The changes in peak flow and inspiratory time between a minimum rise time (first 2 breaths) and a maximum rise time (last 2 breaths), with the Servo-i.
Trigger pressure-time product (PTP) with zero pressure support, with no leak, medium leak, and large leak. Trigger pressure-time product (PTP) with zero.
Relationship between the recruited volume and the arithmetic mean of the ratios of lung density at PEEP 15 cm H2O to lung density at PEEP 5 cm H2O (μP15/P5)
Matrix used to calculate the kappa statistic.
HomeLOX liquid oxygen system, which creates oxygen from a concentrator and refrigerates the concentrator gas to a liquid state, which is stored in a small.
The Arndt endobronchial blocker, one of the commercially available endobronchial blockers for lung isolation. The Arndt endobronchial blocker, one of the.
Picture of bubble PEP devices.
Example of nocturnal oxygen desaturation (NOD) and its physiological consequences. Example of nocturnal oxygen desaturation (NOD) and its physiological.
Several potential sources of error in esophageal manometry are illustrated in this transverse section of the thorax. Several potential sources of error.
Cuff-pressure changes after the addition of 5 mL and 10 mL of air into the cuff of 3 artificial airways, after initial baseline of 30 cm H2O established.
Even though this patient is undergoing positive-pressure mechanical ventilation, the first 4 breaths have a relatively negative pressure (ie, pressure.
An example of delayed cycling during pressure-support ventilation of a patient with COPD, on a Puritan Bennett 7200 ventilator, which has a flow-termination.
Likert-scale agreement ratings regarding the use of extubation readiness parameters by pediatric critical care physicians. Likert-scale agreement ratings.
Example airway pressure and rib-cage impedance in a premature infant supported with the biphasic mode of SiPAP (“sigh” positive airway pressure) from the.
Simulated screenshot of flow starvation in volume control continuous mandatory ventilation. Simulated screenshot of flow starvation in volume control continuous.
Characteristics of a pressure-supported breath.
A: The Parker Flex-Tip tube (left) has a flexible tip pointing toward the center of the distal lumen. A: The Parker Flex-Tip tube (left) has a flexible.
Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value, Area Under the Curve, and 95% CIs for the 0, 10, 25, 50, and 100 SatSeconds.
During this tracing of 30 seconds, the ventilator displays that the patient rate is 16 breaths/min. During this tracing of 30 seconds, the ventilator displays.
Comparison of airway pressure release ventilation (APRV) (blue curve) and biphasic positive airway pressure (BIPAP) (black curve). Comparison of airway.
Example of invasive measurement of respiratory pressures.
A: Machine-triggered intermittent mandatory ventilation (IMV) with inadequate patient triggering of mandatory breaths. A: Machine-triggered intermittent.
Trigger and synchronization windows.
Illustrated here are several features used to determine that the esophageal balloon is correctly placed in the esophagus. Illustrated here are several.
Typical pressure-time curves during forced expiration against an occluded airway in cystic fibrosis (CF) patients and healthy controls. Typical pressure-time.
Top: Stress index (SI) in a patient early in the course of ARDS
This tracing depicts 30 seconds of information.
Schematic drawing of alveolar sizes at upper (A), middle (B), and lower dependent (C) lung regions at end expiration and end inspiration. Schematic drawing.
Effect of respiratory mechanics on cycling of pressure support from inhalation to exhalation. Effect of respiratory mechanics on cycling of pressure support.
In supine obese people, the weight of the abdomen pushes against the diaphragm, causing a cranial displacement of the muscle. In supine obese people, the.
Flow, esophageal pressure, airway pressure, and transpulmonary pressure can be used to calculate respiratory system compliance, chest-wall compliance,
Esophageal pressure, airway pressure, and transpulmonary pressure (PL) with PEEP set at 26 cm H2O (same patient as Fig. 24). Esophageal pressure, airway.
Negative pressures calculated with the Rosen and Hillard formula
We connected the supplemental oxygen supply at 3 places: near the ventilator, near the exhalation valve, and on the nasal mask port. We connected the supplemental.
The curved Macintosh blade and straight Miller blade in standard adult sizes (Macintosh size 3, Miller size 2), with different handle choices available.
Change in mean pulmonary arterial pressure after a 5-min inhalation of the Rho kinase inhibitor Y in rats with hypoxic pulmonary hypertension, with.
Three-dimensional computed tomogram reconstruction of the great vessels extending into the neck, documenting a pseudo-aneurysm of the right innominate.
The Boussignac continuous positive airway pressure (CPAP) is a small plastic cylinder that attaches to a face mask. The Boussignac continuous positive.
Control circuit for set-point or dual targeting schemes.
A: Optimal cutoff point (circled) at which visual analog scale score categorizes subjects with versus those without bronchial obstruction. A: Optimal cutoff.
Control circuit for a servo targeting scheme (eg, Proportional Assist Ventilation). Control circuit for a servo targeting scheme (eg, Proportional Assist.
Negative pressures generated in our airway model.
A: Pressure ulcer on the left cheek of a patient after 1 week of prone positioning using a commercially available endotracheal tube (ETT) holder. A: Pressure.
Ciaglia Blue Dolphin percutaneous technique.
Graphical representation of the locations where spontaneous breaths may occur during the airway pressure (Paw) release ventilation ventilatory cycle. Graphical.
Calculated negative pressure developed in the lung plotted against the outside diameter of the suction catheter to the inside diameter of the airway. Calculated.
Flow, airway pressure, and transversus abdominis electromyogram (EMG) waveforms from a mechanically ventilated patient with COPD receiving pressure-support.
Plots of alveolar PO2, hemoglobin saturation, and alveolar PCO2 as a function of alveolar ventilation in a normal subject at sea level (inspired oxygen.
Components of a patient-triggered mechanical breath.
FEV1 and FVC for the control group (without noninvasive ventilation [NIV]), NIV with an inspiratory pressure (IPAP) of 15 cm H2O and expiratory pressure.
The visual sputum suctioning system.
Correlation between maximum inspiratory pressure and inspiratory load compensation (ILC) ventilatory variables in the 16 difficult-to-wean subjects, prior.
Relationship of mouth pressure (Pmo) and box pressure (Pbox) by body plethysmography under closed–loop panting conditions (left) and open-loop panting.
PaO2/FIO2, leukocyte count, and C-reactive protein during the first 10 days after out-of-hospital cardiac arrest, in subjects with or without early-onset.
Ventilation protocol. Ventilation protocol. The PEEP group raised peak inspiratory pressure (PIP) through 5-cm H2O PEEP increments every 2 min while keeping.
A: Tracheostomy timing in Project IMPACT surgical ICUs
A: Work of breathing before and after nebulized terbutaline delivered via standard nebulization method versus delivered during continuous positive airway.
Sequence plot visualizing the development of symptom frequency for the cohort at the individual level between 2006 and Sequence plot visualizing.
The changes in peak flow and inspiratory time between a minimum rise time (first 2 breaths) and a maximum rise time (last 2 breaths), with the Servo-i.
Progression of spontaneous breathing trials administered during inspiratory muscle strength training study interventions. Progression of spontaneous breathing.
With the patient's mouth opened, the tip of the curved blade (Macintosh) is inserted into the right side of the mouth. With the patient's mouth opened,
Delivery efficiency with different devices, ventilator positions, and ventilator settings. Delivery efficiency with different devices, ventilator positions,
Efficiency of aerosol bronchodilator delivery during continuous high-flow system at different CPAP and flow levels. Efficiency of aerosol bronchodilator.
A: Comparison of pediatric lung transplant survival between different age groups. A: Comparison of pediatric lung transplant survival between different.
Fentenyl and lorazepam use for the first 5 d of ventilatory support are presented. Fentenyl and lorazepam use for the first 5 d of ventilatory support.
Representative waveforms for each of the devices tested from which the oscillatory f was counted. Representative waveforms for each of the devices tested.
Mean nasopharyngeal pressure during high-flow oxygen therapy, with mouth open or closed. Mean nasopharyngeal pressure during high-flow oxygen therapy,
Effects of an automated endotracheal-tube-compensation system on a pressure-support breath. Effects of an automated endotracheal-tube-compensation system.
Presentation transcript:

The esophageal balloon catheter is advanced to approximately 60 cm, so the catheter tip is in the stomach, confirmed by gently compressing the abdomen, which increases the pressure reading on the manometer. The esophageal balloon catheter is advanced to approximately 60 cm, so the catheter tip is in the stomach, confirmed by gently compressing the abdomen, which increases the pressure reading on the manometer. The catheter is then withdrawn to approximately 40 cm while watching for pressure change and visualizing cardiac oscillations. Tom Piraino, and Deborah J Cook Respir Care 2011;56:510-513 (c) 2012 by Daedalus Enterprises, Inc.