Building Reach Codes Advancing safer, healthier and more affordable buildings Reach Code Basics Building Model Codes EV Model Codes City Actions GHG Emissions.

Slides:



Advertisements
Similar presentations
SSC-NM0053 Determination of Greenhouse Gas Emissions Reductions Based on Whole- Building Simulation of Building Mitigation Efforts Using eQUEST/DOE-2.2.
Advertisements

Grenada Sustainable Energy Plan Stakeholders Meeting April 5, 2002.
By: R.M. Chitranshi. ECBC With the background of high energy saving potential and its benefits bridging the gap between demand and supply, reducing environmental.
Energy Square 1111 “O” Street, Suite 223 Lincoln, Nebraska Website: Phone:
State and Local Initiatives to Combat Global Warming AB A Framework for Change James N. Goldstene California Air Resources Board October 22, 2008.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Grid-interactive Renewable Heating Paul Steffes Steffes Corporation
IEPR Staff Workshop – ZNE Buildings
Service Calculations One and Two Family And Multi- Family Paul Revere Chapter May Meeting.
Take A Load Off, Texas SM is provided by Oncor Electric Delivery LLC as part of the company’s commitment to reduce energy consumption and demand. Frontier.
Planning Department – Building and Safety Adoption of the 2010 California Code of Regulations Presented By: Building and Safety & Fire Prevention.
Green Initiatives & Climate Protection 2011 Annual Report Brian Moura Assistant City Manager July 11, 2011.
SEEA Presentation to SEES March 2006 SEEA Presentation to SEES February 2006 SOUTHEAST ENERGY EFFICIENCY ALLIANCE.
Public Information Meeting Tools for Intensification within the Yonge/Davis Urban Centres Marion Plaunt MES, MCIP, RPP Planning and Building Services August.
C A L I F O R N I A E N E R G Y C O M M I S S I O N California Energy Policy: Zero Net Energy Homes in 2020 Martha Brook, P.E. High Performance Buildings.
Residential Weatherization and Ventilation Subcommittee Presentation to the Regional Technical Forum August 30, 2011.
10 Turn off Lights Not in Use Motion Sensors simple ways to go green
CPUC Role in AB 32 Implementation LIOB – 2 nd June, 2010 San Diego, CA.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
Marin Clean Energy Choice and Competition - Driving Innovation towards Environmental Goals May 2015.
1 Summary of Phase I – Phase III Progress and Accomplishments and Phase IV Work plan April 27, 2004.
Presentation Overview EECAP summary Plan development process GHG inventory results Policy recommendations EAP implementation.
ITEM 6.a AT GREEN BUILDING ORDINANCE City Council – August 25, 2009.
California Energy Efficiency Policy and Goals Beena Morar Southern California Edison June 14, 2016.
Back to the Basics: Climate and Energy Workshop Energy Efficiency Best Practices Karalee Browne.
Energy Efficiency and Customer Research and Development
BPU Energy Efficiency Committee April 11, 2017
City of San Mateo 2016 Reach Code
Energy Star Program Manager
Kenya’s INDC: Actions in the Energy Sector
Capital Region Clean Energy Communities Program
Overall Objectives of NAMA
WHAT IS CLEAN ENERGY DC? WHAT IT IS WHAT IT IS NOT
Truss Heel Heights and Energy Code Requirements
Devin Rauss Building California’s Flexible Grid October 27, 2018
The Florida Energy and Climate Commission (FECC)
Home Energy Savings Program Wyoming
Market Operations Engagement Group EVSE Working Group – Principles
Proposed FY18 Program Changes
Distributed Generation Chau Nguyen, Pricing & Sales Support
DOE Data Center Energy Efficiency Program and Tool Strategy
Updates to the Traffic Reduction and Transportation Improvements Fee (TR/TIF) City Council July 24, 2017.
City-wide LED Street Light Conversion Program
Compliance Software Tool Approval Technical Assistance Manual
Bay Area Model Solar Photovoltaic Ordinance
Bridging State Policy to Local Implementation
Three times more energy reaches the customer with natural gas
Mandatory Solar in New Home Construction
Measuring Progress Towards GHG Reductions Presented by: Stefan Unnasch
State Allocation Board Hearing Solar Energy and Energy Efficiency Project Options for California Schools Mark Johnson, Energy Solutions Manager - Schools.
Residential Water Heater Market in CA
City Council April 30, 2018 Item 13
City of Ventura Green Building Standards
WESTERN REGIONAL WORKSHOP
VAEEC Programmatic Update
Metropolitan Mayors Caucus Illinois Energy Bills
Planning Commission.
Planning Directors Meeting
BUREAU OF STANDARDS JAMAICA
Building a “FutureFit” Silicon Valley
Heat Pump Water Heaters: Evolution to a “California Essential”
2019 GREEN BUILDING PROJECT AWARDS:
Mayors’ Commission on Climate Change
Mayors’ Commission on Climate Change
Meeting Dates June 19 October 16 July 17 November 20
Building Reach Codes Advancing safer, healthier and more affordable buildings Reach Code Basics Building Model Codes EV Model Codes City Actions GHG Emissions.
Building Reach Codes Advancing safer, healthier and more affordable buildings Reach Code Basics Building Model Codes EV Model Codes City Actions GHG Emissions.
Sustainable Agricultural Lands Conservation Program
Presentation transcript:

Building Reach Codes Advancing safer, healthier and more affordable buildings Reach Code Basics Building Model Codes EV Model Codes City Actions GHG Emissions Savings

Purpose Support Cities in meeting climate goals Encourage safer, healthier all-electric buildings within the building code Install EV charging during building construction commensurate with local needs

Guiding Principles Provide cost-effective pathways for both All-Electric and Dual-Fuel (electric + gas) construction Establish the highest possible requirements that are still cost- effective for Dual-Fuel construction. Recommendations must comply within CEC energy code guidelines

Revision History DATE BY EDITS Aug 1 B.H. Version 1 Aug 28 R.R. Corrected EV reference in summary (MUD EV Ready for all units not “spaces”), added subtitle sections and reordered building slides for clarity, added infographic and UC study cost info, slide 6: clarified language, slide 20: added “2019” to column, slide 33: removed confusing reference to “EV Capable being more extensive”, other minor fmt. Sept 3 R.R. Replaced infographic slide 15 for corrected construction savings (DNV GL correction).

I. Reach Code Introductory Slides What are Reach Codes Benefits Model Code Summary Partners for project Timeline

What are Reach Codes? Local enhancements to state code Adopted with current building code cycle Current PCE initiative aimed at improved economic and energy performance Addresses: Building electrification – reduced use of natural gas (methane) and associated emissions Electric vehicle (EV) charging – increased EV readiness

Benefits of Reach Codes Major economic value for residents now and prevents expensive future retrofits Safer and healthier homes – no combustion Enables greater EV adoption Fiscal prudence – more cost effective to address at new construction Advance climate goals  Reduced fueling costs for residents By 2025 approximately 45,000 EVs in SM Co EV savings over gas car $1,200+/year Reduced capital expenses 25,000 new housing units EV Reach Code <$1.5k/unit at new construction $7k/unit for retrofit

Model Code Summary Code Element Approach Building Electrification Provides 2 tracks for developers: All-Electric or Mixed-Fuel All-Electric (preferred) is less expensive, delivers more benefit Mixed-Fuel allows natural gas but has higher efficiency requirements Details vary by building segment Electric Vehicle Readiness Provides “plug and play” access to vehicle charging Single family: Level 2 (dryer outlet power) and Level 1 (standard 110v outlet) Multi-unit dwellings: one “EV Ready” space per unit* Office: 10% Level 2, 10% Level 1, and 30% EV Capable Other Commercial: 6% Level 2 installed and 5% Level 1 installed PCE will provide funding support for affordable housing to address EV measures

Included in SVCE recommendation Reach Code Recommendations Cost-Effective W/in CEC Guidelines Included in SVCE recommendation Base Title 24 Yes All-Electric Yes – Pathway 1 Dual-Fuel Yes – Pathway 2 Mostly Electric (residential only) Not as a standalone pathway Yes – Pathway 2A CalGreen Tier 1 or Tier 2 No Ban on Natural Gas No1 1 A ban utilizes a city’s Police power, not via a local amendment to Energy Code.

Single Family Residence – Base Code All-Electric (1) Electric & Gas (2) TRC Meet Title 24 requirements Meet Title 24 requirements, including: Pre-wire water heater location for future electric heat pump

No Changes Single Family Residence – Base Reach Code All-Electric (1) Electric & Gas (2) TRC Meet Title 24 requirements Meet Title 24 requirements, including: Pre-wire water heater for future electric heat pump Pre-wire for future electric appliances (+$ 750) Additional Energy Efficiency measures (+$1500) Solar thermal or Battery Storage (+ $6000) No Changes

Single Family –Reach Code option All-Electric (1) Electric & Gas (2) “Mostly Electric” (2A) TRC Meet Title 24 requirements, including: Pre-wire water heater for future electric heat pump Pre-wire for future electric appliances (+$ 750) Additional Energy Efficiency (+$1500) Solar thermal or Battery Storage (+ $6000) Meet Title 24 requirements, including: Pre-wire for future electric heat pump Install Electric water and space heating (allows natural gas for cooking) Pre-wire for future electric range (+$ 250) Additional Energy Efficiency measures (+$1500) Solar thermal or Battery Storage (+ $6000) Meet Title 24 requirements No Changes

Project Partners Lead consultant Technical support Facilitation support Regional partner Cost benefit approvals

Last September, Everything Changed SB-100 All electricity is carbon free by 2045 Executive Order B-55-18 Carbon neutral by 2045

August through October Reach Code Timeline Date/Timeframe Activity Dec. 2018 PCE, SVCE and County of San Mateo initiate reach code initiative January Reach Code kickoff event for city staff February Statewide Cost-Effectiveness study March Building Reach Code Workshops April 11 and 24 Draft Model Reach Codes Measures available April & May City-specific stakeholder engagements 15-May Last input into model code measures June Model reach code language shared June through August Outreach and adoption technical assistance July through October City Councils vote on desired reach codes (depends on City’s workplan) August through October Submit Code Packet for CEC approval January 1, 2020 Potential for reach code to go into effect at the same time as state code update 2020-2022 Opportunities to adopt reach code throughout three year code cycle, PCE and County to provide training and support for code implementation

Summary Timeline Transitioning leadership to the cities Stakeholders Consultant Support Available Item Date Leader Participant(s) Content Coordination Technical Cost Effectiveness Study Feb 2019 Consultant SVCE/PCE Draft Model Codes Mar 2019 Cities External Stakeholder Input May 2019 Cities, SVCE/PCE, Community City Staff Recommendation Aug 2019 Consultant, Stakeholders Submit for Council Vote Fall 2019 City Council, Consultant Training City Staff Dec 2020 City Staff New Code Effective Jan 2020 Transitioning leadership to the cities SVCE and Consultants providing support for each of these next steps

Guiding Principles for Reach Codes Preserve a low cost compliance option to minimize impact on construction costs Encourage development of healthier, safer, lower emission buildings Reflect the values of our community Leaders in EV, solar and battery adoption rates nationwide TRC

Key Terms All-Electric - buildings using electricity for space and water heating systems Mixed Fuel – buildings using natural gas for space and water heating systems Compliance Margin – how much more energy efficient than code minimum can be done in a cost effective manner, typically expressed as a percentage (e.g. 5% compliance margin) Performance Pathway – exceed code by a certain compliance margin using CEC-approved modeling software (e.g. 5%) Prescriptive Pathway – exceed code by including a list of specific cost-effective measures (e.g. drain heat recovery or batteries), see appendix for examples. Climate Zone – San Mateo county is located within Climate Zone 3. Santa Clara county is mostly Climate Zone 4, with a small portion in Climate Zone 3. TRC

II. Building Model Code Details Cost and GHG Comparisons 2019 T24 Code basics EDR Prescriptive vs Performance Pathways Building Model Code Language

University of California- All-Electric New Construction UC Carbon Neutral Buildings Cost Study. June 23, 2017 https://www.ucop.edu/sustainability/_files/Carbon%20Neutral%20New%20Building%20Cost%20Study%20FinalReport.pdf 2017 Study

Variability in Savings Statewide Residential Building Electrification in California, E3, April 2019

All-Electric New Residential Bay Area Conservative Case Sources: Costs of electrification – Residential Building Electrification in California, E3 -- April 2019 Annual Energy Use & Generation – Building energy simulation performed by DNV GL Residential Building Electrification in California, E3, April 2019

Why a Reach Code? What if new buildings and vehicles were powered by clean electricity during this 3-year code cycle? Sq Ft CO2 per year Units per year Years in Service Years in Code Cycle Total Avoided CO2* Single Family 2,700 2 tons X 100 50 3 = 30,000 tons Multi-Family 1,000 1 ton 10,000 1,500,000 tons Office 100,000 120 tons 20 30 2,160,000 tons TRC 15,000 vehicles off the road=750,000 tons 50 tons per vehicle Single family: 6,000 vehicles Multifamily: 300,000 vehicles not on the road Office: 430,000 vehicles off the road Miles per Year CO2 per year EV’s added per year Years in Service Years in Code Cycle Total Avoided CO2 Car 12,000 5 tons X 5,000 10 3 = 750,000 tons *CO2 impacts reflect carbon-free electricity, currently met by SVCE while PCE’s goal is GHG free by 2021

GHG Comparison Mixed fuel / All electric 2017 / All Electric 2030 grid

2019 State Code Basics (Title 24 Chapter 6)

What’s already included in the 2019 Code Residential Non-Res Performance Compliance Margin Energy Design Rating (EDR) Percentage Solar Photovoltaics (PV) Installation Sized to offset annual kWh consumption of mixed-fuel n/a Electric-ready 120V/20A for future electric water heater installation Prewiring of all homes for future electric heat water heater Solar PV sized to cover the electric loads associated with a mixed-fuel home Use of Energy Design Rating (EDR) for all residential energy models A minimum quantity, level, and readiness of EV charging infrastructure for residential, multi-family, and non-residential building types. TRC

What is EDR? In California codes have shifted from what was being called zero net energy to the Energy Design Rating, or “EDR”. EDR allows for a range of energy performance, rather than simply targeting zero, as in Zero Net Energy. The EDR measurement is the sum of an efficiency score and an overall score. The efficiency score is based on measures such as insulation, windows, and envelope efficiency. The overall score factors in things like onsite renewable energy and fuel sources. A building with a score of zero (or less) has maximized energy efficiency and most likely added on-site renewable generation such as rooftop solar. An EDR of Zero is equal to Zero Net Energy or Zero Energy. Zero or less is most easily achieved by an all- electric building design. A higher EDR score would indicate a less efficient building.

Options are formatted in green highlights Mandatory + Reach Code Options for New Construction, Additions, Alterations Item 2019 Code Reads Reach Code Reads Water Heating 120V/20A circuit 240V/30A circuit* Condensate drain Clothes Drying - 240V/40A circuit* Cooking 240V/50A circuit* Space Conditioning Optional add-on to Reach Code Location/design addressing air source and footprint 240V/30A circuit* *or adequate capacity Reach Code Optional Requirements TRC Item Reach Code Option Solar (PV) installed Require PV (non-residential only) Performance documentation  Encourage building simulation and compliance forms by certified energy analysts (must include definition of what meets certified standard)

Building Electrification Reach Codes by Building Type Performance and Prescriptive Paths

Buildings Pathways: Performance or Prescriptive Compliance Margin(s) equal to or better than Title 24 code for buildings based on fuel types What is required for All-Electric Buildings (ex. 0% better than T24) What is required for Mixed Fuel Buildings (ex. Reach code 10% better than T24) Pathways for a builder to meet certain EDR requirements Performance – use modeling software to show the proposed building meets or exceeds the compliance margin (%) established in the reach code, OR Prescriptive – install from a list of specific technologies as defined within the reach code TRC

Single and Two-family New Construction Performance Path   Prescriptive Path 1. All Electric. Demonstrate that the proposed home will be all electric, OR Build All Electric. Meet 2019 Title 24 Part 6. 2. Mixed Fuel Building. Proposed Design Building shall be at least 10 EDR points less than the Total Energy Design Rating calculated for the Standard Design Building, OR Mixed Fuel Building a. Low leakage ducts b. R-10 perimeter slab insulation c. Compact hot water distribution d. Fan efficacy of 0.35 Watts/cfm e. Either 1) 5 kWh battery OR 2) A solar water heating system. 2A. Electrically Heated Building (electric space and water heating, gas cooking and/or clothes drying). Proposed Design Building shall be at least 2 EDR points less than the Energy Efficiency Design Rating calculated for the Standard Design Building, OR Electrically Heating Building a. Low leakage ducts. b. R-10 perimeter slab insulation. c. Compact hot water distribution. d. Fan efficacy of 0.35 Watts/cfm. 1 + 2 OR Suggest #1 AND #2. Option to do #1, #2, and #3 Option to not have a prescriptive path for mixed-fuel buildings. Option #3 would require a more in-depth review to enforce 1 + 2 + 2A “Menu options” are formatted with green highlights

Multifamily New Construction (≤3 stories) Performance Path   Prescriptive Path 1. All Electric. Demonstrate that the proposed home will be all electric, OR Build All-Electric and Meet 2019 Title 24 Part 6. 2. Mixed Fuel Building. Proposed Design Building shall be at least 10 EDR points less than the Total Energy Design Rating calculated for the Standard Design Building, OR Mixed Fuel Building a. low leakage ducts in conditioned space b. 0.25 ASR cool roof c. R-10 slab insulation d. compact Hot Water distribution e. 0.35 W/cfm HVAC fan d. Either 1) 2.75 kWh battery/dwelling OR 2) A solar water heating system. 2A. Electrically Heated Building (electric space and water heating, gas cooking and/or clothes drying). Proposed Design Building shall be less than the Energy Efficiency Design Rating calculated for the Standard Design Building Electrically Heated Building Meet 2019 Title 24 Part 6 1 + 2 OR Suggest #1 AND #2. We found not a lot of EDR improvements of MF building Option #2 AND #3 Option to not have a prescriptive path for mixed-fuel buildings. Option #3 would require a more in-depth review to enforce 1 + 2 + 2A “Menu options” are formatted with green highlights

Nonresidential Performance Path Prescriptive Path 1 + 2 OR 1 + 2 + 2A 1. All Electric. Demonstrate that the proposed building will be all electric, OR Build All Electric and meet 2019 Title 24 Part 6. 2. Mixed Fuel Building, All Occupancies. Demonstrate that the energy use of the proposed building is 9% more efficient than the 2019 State Energy Code, OR Mixed Fuel Building a. Fenestration with a solar heat gain coefficient ≥ 0.22. b. Airflows to be equal to the zone ventilation minimums. c. Economizers in air handlers ≥ 33,000 Btu/h d. Reduced the lighting power density (Watts/ft2) by ten percent (10%) e. In common areas, improve lighting: 1) Daylight dimming plus off AND 2) Institutional Tuning f. Install drain water heat recovery. 2A. Mixed Fuel Building, Office and Mercantile. Demonstrate that the energy use of the proposed building is 15% more efficient than the 2019 State Energy Code Mixed Fuel Building a. Fenestration with a solar heat gain coefficient ≥ 0.22. b. E/W fenestration area is < ½ of the N/S fenestration. c. Airflows to be equal to the zone ventilation minimums. d. Economizers in air handlers ≥ 33,000 Btu/h e. Reduced the lighting Watts/ft2 by 10% f. Improve lighting: 1) Daylight dimming plus off AND 2) Institutional Tuning AND 3) Occupant sensing in open plan offices 1 + 2 OR Suggest #1 AND #2. Option to do #1, #2, and #3 Option to not have a prescriptive path for mixed-fuel buildings. Option #3 would require a more in-depth review to enforce 1 + 2 + 2A

Electric Buildings - Single and Two-family New Construction   2016 Energy Code 2019 CALGreen PCE/SVCE Proposed All-Electric Mixed-Fuel Single-Family Two-Family Townhome Meet Title 24 Energy Requirements using: Performance (energy modelling) or Prescriptive (measures) Meet Title 24 Energy Requirements using: Performance or Prescriptive Meet Title 24 Energy Requirements using: Performance or Prescriptive Exceed Title 24 Energy Requirements using: Performance (10 EDR points) Prescriptive (additional measures) Solar generation ready zone in subdivisions with ten or more buildings Requires solar generation Requires solar generation Requires solar generation + Solar water heating or 1.5 kWh battery Required adjacent outlet for future electric replacement: Gas water heaters Use electric appliances Required adjacent outlet for future electric replacement: Gas water heaters Gas clothes dryers Gas ranges and stoves

Electric Buildings – Multifamily (≤ Stories)New Construction   2016 Energy Code 2019 CALGreen PCE/SVCE Proposed All-Electric Mixed-Fuel Single-Family Two-Family Townhome Meet Title 24 Energy Requirements using: Performance (energy modelling) or Prescriptive (measures) Meet Title 24 Energy Requirements using: Performance or Prescriptive Meet Title 24 Energy Requirements using: Performance or Prescriptive Exceed Title 24 Energy Requirements using: Performance (10 EDR points) Prescriptive (additional measures) Solar generation ready zone Requires solar generation Requires solar generation Requires solar generation + Solar water heating or 2.75 kWh battery Required adjacent outlet for future electric replacement: Gas water heaters Use electric appliances Required adjacent outlet for future electric replacement: Gas water heaters Gas clothes dryers Gas ranges and stoves

Electric Buildings – Nonresidential   2016 Energy Code 2019 CALGreen PCE/SVCE Proposed All-Electric Mixed-Fuel Single-Family Two-Family Townhome Meet Title 24 Energy Requirements using: Performance (energy modelling) or Prescriptive (measures) Meet Title 24 Energy Requirements using: Performance or Prescriptive Meet Title 24 Energy Requirements using: Performance or Prescriptive Exceed Title 24 Energy Requirements using: Performance (9% compliance margin) Prescriptive (additional measures) Solar generation ready zone Solar generation ready zone Solar generation ready zone Solar generation ready zone Required adjacent outlet for future electric replacement: Gas water heaters Use electric appliances Required adjacent outlet for future electric replacement: Gas water heaters Gas clothes dryers Gas ranges and stoves

EVCI Cost Retrofit vs. New Terms and Rates Codes III. EV Model Codes EVCI Cost Retrofit vs. New Terms and Rates Codes

EVCI – Cost of New vs Retrofit Investing in EV infrastructure during new construction saves 40-400% of costs compared to retrofitting it later. Build it and they will Come EV Ready EV Capable EV Ready EV Capable EV Ready EV Capable

Key Terms: EV Infrastructure EV Terms, Charge Rates Key Terms: EV Infrastructure Level 1 “Trickle Charging” Standard household outlet 15-20 Amp, 120v AC Driving distance provided: 3-4 miles/hour Level 2 “Standard Charging” Equivalent to a dryer outlet. 40+ Amp, 208/240v AC Driving distance provided (standard charging): 25-30 miles/hour Language in (…..) is the common term for the regulatory/ legal “code” word before. Level 3 “DC Fast Charging / SuperCharging” 24-350kW Driving distance provided 72-1,200 miles/hour

EV Terms, Readiness of Charging Station Key Terms: EV Infrastructure EV Capable - Some Assembly Required Panel capacity, raceway (conduit) only at critical areas (underground, pinch points, etc.) Definition is less stringent than CALGreen 2019 EV Ready - Plug & Play Panel capacity, raceway (conduit), overcurrent protection device (breaker), wire, receptacle & signage. Can refer to Level 1 or Level 2 ELECTRIC VEHICLE OUTLET Yellow differentiating components of “EV Ready” Language in (…..) is the common term for the regulatory/ legal “code” word before. EV Charging Station (EVCS) - Level 2 Charge! Charging station fully installed. All the equipment needed to deliver electrical energy from an electricity source to the EV at Level 2

Electric Vehicles - Single and Two-family New Construction   2016 CALGreen 2019 CALGreen PCE/SVCE Proposed Mandatory Single Family Two-Family Townhome (1) Level 2 EV Capable for one parking space per dwelling unit 2 EV spaces total: 1 Level 2 EV Ready circuit 1 Level 1 EV Ready circuit ELECTRIC VEHICLE OUTLET

Electric Vehicles - Single and Two-family New Construction   2016 CALGreen 2019 CALGreen PCE/SVCE Proposed Mandatory Single Family Two-Family Townhome (1) Level 2 EV Capable for one parking space per dwelling unit 2 EV spaces total: 1 Level 2 EV Ready circuit 1 Level 1 EV Ready circuit ELECTRIC VEHICLE OUTLET

Electric Vehicles - Multifamily New Construction OUTLET Electric Vehicles - Multifamily New Construction   2016 CALGreen 2019 CALGreen PCE/SVCE Proposed Mandatory Multi-Family 3% 10% 25% 100% 75% ≤20 dwelling units >20 dwelling units 3% Level 2 EV Capable for buildings with ≥17 units 10% Level 2 EV Capable ≤20 units: One Level 2 EV Ready per dwelling >20 units: Of all dwelling units, 25% Level 2 EV Ready (10% in affordable housing) 75% are Level 1 EV Ready (90% in affordable housing)

Electric Vehicles - Non-Residential, Office & Commercial OUTLET   2016 CALGreen 2019 CALGreen PCE/SVCE Proposed Mandatory Non-Residential Commercial: Of all parking spaces, 6% Level 2 EVSE 5% Level 1 EV Ready Office building: 10% Level 2 EVSE 10% Level 1 EV Ready 30% EV Capable or EV Ready 6% Level 2 EV Capable (for buildings with at least 10 parking spaces) Over 100 spaces: option for 80kW DC Fast Charger per 100 spaces

Reach Code – EV Charging CalGreen (Part 11) provides minimum requirements for each aspect of EV Charging per building type Code Building Type Quantity Readiness Charging Speed Residential 1 per dwelling unit Capable Level 2 Multi-Unit Dwelling 10% of total spaces Commercial 6% of total spaces Readiness Installed Ready Capable To enact a reach code for EV charging, increase the Quantity, Readiness and/or Charging Speed. Speed Level 3 Level 2 Level 1 Reach Code Building Type Quantity Readiness Charging Speed Residential 1 per dwelling unit Capable Ready Ready Level 2 Level 1 Multi-Unit Dwelling 10% 25% of total spaces Commercial 6% 10% of total spaces [above charts simplified for illustration purposes]

IV. City Actions What steps to take What are other cities doing Outreach Materials & Tools Contacts

Solar Thermal or Batteries Green Construction w/in CalGreen What can we do with Code Base Title 24 Code or Proposed Reach Code or CalGreen Reach Code Dual Fueled All Electric Required Code Base Code Incremental Cost1 $0 Cost Effective Yes Incremental Equipment1 None Carbon Emissions Tons Pounds Frequency of Use Most Least Dual Fueled All Electric Reach Code Base Code $5,500 $0 Yes Solar Thermal or Batteries None Tons Pounds more Dual Fueled All Electric Reach Code Base Code ~ $15,000 $0 No Yes All Energy + Green Construction w/in CalGreen None Tons Pounds TRC 1 To meet Code A ban on gas would result in only All-Electric buildings but Cities would adopt the ban outside of the Building Code.

Action for City XXX City Manager to submit Letter of Intent for $10,000 grant for reach code adoption and implementation support Direct staff to review materials, meet with consultants, and work on customizing model code language Calendar Council review and action

Participation to-date by Agency

Implementation & Adoption Resources Resources & Tools in Development Case Studies Website Homeowner Flyer FAQs Trainings Cost Effectiveness Presentation Tool Carbon Emissions Savings Ordinance Language, Staff Report PPTs

Building staff/permit Tools & Resources Permitting, enforcement, and inspection resources Permit Checklist Inspection Checklist Training for Building Department Staff FAQs

V. GHG Emission Reductions

2,100 Square Foot Single Family Home Key Takeaways High carbon savings of electrification This improves with time, looking to 2030 If gas leaks are considered, mixed fuel emissions increase

2,700 Square Foot Single Family Home

6,960 Square Foot Multi-Family Home

Office

Hotel

Retail

Contact Website: www.PeninsulaReachCodes.org Contact: Rafael Reyes Director of Energy Programs rreyes@peninsulacleanenergy.com (650) 260-0087 Rachael Londer, Resource Conservation Specialist County of San Mateo rlonder@smcgov.org (650) 363-4077

Thank you!

APPENDIX

Outline Background & context Goals Where we go from here

Background & Context New Building codes are issued every three years Cities can amend the code (“reach code”) to meet local conditions New Code goes into effect January 1, 2020

(amend some sections within these two parts only) Building Codes All 11 sections must be adopted this year by Council Reach Code (amend some sections within these two parts only) Energy Part 6 CALGreen Part 11 2019 2019 TRC 2019

Wave of Local Action Across CA 50+ cities pursuing reach codes On July 16, Berkeley banned gas in new construction PG&E publicly supported the Berkeley gas ban

Outline Background & context Goals Where we go from here

Goals for the new Code Encourage Healthier, Safer buildings Increase number of low/no pollution vehicles Pathway toward CA emission goals Fiscal responsibility

Healthier, Safer Buildings Asthma “Remove or reduce indoor exposures by promoting the use of building materials, consumer products, and appliances that emit little or no air pollutants.” - Asthma and Indoor Air Quality in the Home by RAMP1 General Safety “Carbon monoxide, or ‘CO,’ is an odorless, colorless gas that can kill. CO is found in fumes resulting from burning fossil fuels.” - Fire Safety Topics by National Fire Safety Council 1 Regional Asthma Management and Prevention

Support low/no pollution vehicles Santa Clara County has the highest EV adoption rate in the state Code includes average minimum EV charging levels Conclusion: include a higher level of EV charging infrastructure already desired by our customers

Pathway toward Goals Major goals for CA Electricity – via SVCE 2050 Goal - 2050 Major goals for CA Electricity – via SVCE Natural Gas Transportation Fuels

Fiscal Responsibility If the future has less/no natural gas, any new gas service today creates a problem for tomorrow Adding pollution while goals require reductions Adding natural gas infrastructure while shrinking customer base Installing EV charging later as a retrofit cost 2x-5x more than during new construction All-electric homes cost less to build (no gas service/piping, 1 less appliance). If that savings is invested in solar (for example), all-electric homes cost same or less to operate.

Outline Background & context Goals Where we go from here

Reach Codes – inside the building All-Electric Buildings Dual-Fuel Buildings Energy Part 6 Adopt 2019 Code + Pre-wiring for Future Electric Devices Increase Energy Efficiency Install Solar Thermal or Battery Storage (residential only) Adopt 2019 Code as is. No Reach Code. TRC

Reach Codes – EV Charging only Base Code EV Charging Reach Code CALGreen Part 11 Quantity Speed Readiness Increase the Quantity, Speed, and/or Readiness Single Family Residential Multi-Family Commercial Quantity Speed Readiness Quantity Speed Readiness TRC

Electric Buildings - Single and Two-family New Construction 2016 Energy Code 2019 Energy Code PCE/SVCE Proposed All-Electric Mixed-Fuel (CZ3) Single-Family Two-Family Townhome Meet Title 24 Energy Requirements using: Performance (energy modelling) or Prescriptive (measures) Meet Title 24 Energy Requirements using: Performance or Prescriptive Meet Title 24 Energy Requirements using: Performance or Prescriptive Exceed Title 24 Energy Requirements using: Performance (10 EDR points) Prescriptive (additional measures) Solar generation ready zone in subdivisions with ten or more buildings Requires solar generation Requires solar generation Requires solar generation + Solar water heating OR 5 kWh battery Required adjacent outlet for future electric replacement: Gas water heaters Use electric appliances Required adjacent outlet for future electric replacement: Gas water heaters Gas clothes dryers Gas ranges and stoves

Electric Buildings – Multifamily (≤ 3 Stories) New Construction 2016 Energy Code 2019 Energy Code PCE/SVCE Proposed All-Electric Mixed-Fuel (CZ3) Single-Family Two-Family Townhome Meet Title 24 Energy Requirements using: Performance (energy modelling) or Prescriptive (measures) Meet Title 24 Energy Requirements using: Performance or Prescriptive Meet Title 24 Energy Requirements using: Performance or Prescriptive Exceed Title 24 Energy Requirements using: Performance (10 EDR points) Prescriptive (additional measures) Solar generation ready zone Requires solar generation Requires solar generation Requires solar generation + Solar water heating OR 2.75 kWh battery Required adjacent outlet for future electric replacement: Gas water heaters Use electric appliances Required adjacent outlet for future electric replacement: Gas water heaters Gas clothes dryers Gas ranges and stoves

Electric Buildings – Nonresidential 2016 Energy Code 2019 Energy Code PCE/SVCE Proposed All-Electric Mixed-Fuel (CZ3) Single-Family Two-Family Townhome Meet Title 24 Energy Requirements using: Performance (energy modelling) or Prescriptive (measures) Meet Title 24 Energy Requirements using: Performance or Prescriptive Meet Title 24 Energy Requirements using: Performance or Prescriptive Exceed Title 24 Energy Requirements using: Performance (10% -15% compliance margin) Prescriptive (additional measures) Solar generation ready zone Solar generation ready zone Requires solar generation Requires solar generation Required adjacent outlet for future electric replacement: Gas water heaters Use electric appliances Required adjacent outlet for future electric replacement: Gas water heaters Gas clothes dryers Gas ranges and stoves

Electric Vehicles - Single and Two-family New Construction   2016 CALGreen 2019 CALGreen PCE/SVCE Proposed Mandatory Single Family Two-Family Townhome (1) Level 2 EV Capable for one parking space per dwelling unit 2 EV spaces total: 1 Level 2 EV Ready circuit 1 Level 1 EV Ready circuit ELECTRIC VEHICLE OUTLET

Electric Vehicles - Multifamily New Construction OUTLET Electric Vehicles - Multifamily New Construction   2016 CALGreen 2019 CALGreen PCE/SVCE Proposed Mandatory Multi-Family 3% 10% 25% 100% 75% ≤20 dwelling units >20 dwelling units 3% Level 2 EV Capable for buildings with ≥17 units 10% Level 2 EV Capable ≤20 units: One Level 2 EV Ready per dwelling >20 units: Of all dwelling units, 25% Level 2 EV Ready (10% in affordable housing) 75% are Level 1 EV Ready (90% in affordable housing)

Electric Vehicles - Non-Residential, Office & Commercial OUTLET   2016 CALGreen 2019 CALGreen PCE/SVCE Proposed Mandatory Non-Residential Office building: 10% Level 2 EVSE 10% Level 1 EV Ready 30% EV Capable or EV Ready Other nonresidential: Of all parking spaces, 6% Level 2 EVSE 5% Level 1 EV Ready 6% Level 2 EV Capable (for buildings with at least 10 parking spaces) Over 100 spaces: option for 80kW DC Fast Charger per 100 spaces

Tools & Resources www.SiliconValleyReachCodes.org Model Code Language available Staff Report templates available Support for staff via SVCE’s consulting partner Stakeholder meetings Staff/Council briefings Presentation content Q&A

Call to Action If you are currently engaged… Inform your city staff you are looking forward to seeing their recommendations or you would like a study session Encourage staff to utilize our support If you are not currently engaged… It’s not too late! www.SiliconValleyReachCodes.org

Contact Info John Supp Manager – Account Services 408-721-5301 x1014 John.Supp@svcleanenergy.org