Aortic root remodeling with the “cuff” technique for stentless valve implantation  Massimo Massetti, MD, Piergiorgio Bruno, MD, Gerard Babatasi, MD, Olivier.

Slides:



Advertisements
Similar presentations
Aortic Valve Replacement With Patch Enlargement of the Aortic Annulus
Advertisements

Late Surgical Explantation and Aortic Valve Replacement After Transcatheter Aortic Valve Implantation  Louis W. Wang, MBBS, MM, Emily K. Granger, MBBS,
Reinforcement of the Pulmonary Autograft with a Prosthetic Graft to Prevent Dilatation After the Ross Procedure  Thierry Carrel, MD, Florian Schönhoff,
The Completion Bentall Procedure
Valve-Sparing Aortic Root Replacement
Lars G. Svensson, MD, PhD, Eugene H. Blackstone, MD 
Unusual Gastrointestinal Bleeding After Sutureless Aortic Valve Replacement: A Word of Caution  Jules Iquille, MD, Joseph Nader, MD, Eric Colpart, MD,
Homograft Aortic Replacement for Infected Mediastinal False Aneurysm
Yuanjia Zhu, BS, Eric E. Roselli, MD, Jay J. Idrees, MD, Charles M
Early Results of Valve-Sparing Reimplantation Procedure Using the Valsalva Conduit: A Multicenter Study  Davide Pacini, MD, Fabrizio Settepani, MD, Ruggero.
Aortic valve–sparing reimplantation for dilatation of the ascending aorta and aortic regurgitation late after repair of congenital heart disease  Masamichi.
False-positive diagnosis of ascending aorta dissection by single-plane transesophageal echocardiography  Eugenio Neri, MDa, Dominique Maiza, MDa, Gwenael.
A new modified Bentall procedure: the flanged technique
Can An Early Peri-Anastomotic LITA Stenosis Be Reversible?
Simple Modification of “T
Minimally Invasive Mitral Valve Surgery: Influence of Aortic Clamping Technique on Early Outcomes  Amine Mazine, MD, Michel Pellerin, MD, Jean-Sébastien.
CTSNet: a unique educational vehicle
Valved stentless composite graft: clinical outcomes and hemodynamic characteristics  Paul P Urbanski, MD, Anno Diegeler, MD, Alexander Siebel, MD, Michael.
A “Double Overlap” Suture Technique for the Proximal Attachment of a Composite Graft to the Aortic Annulus  John A. Rousou, MD, Abdallah K. Alameddine,
Methods for graft size selection in aortic valve-sparing operations
Successful aortic root remodeling for repair of a dilated pulmonary autograft after a ross- Konno procedure in early childhood  Shintaro Nemoto, MD, PhD,
Surgical intervention criteria for thoracic aortic aneurysms: a study of growth rates and complications  Michael A Coady, MD, John A Rizzo, PhD, Graeme.
The CarboMedics “Top-Hat” supraannular prosthesis
Mini-Bentall Procedure: The “French Cuff” Technique
Ross operation after failed valve-sparing reimplantation: Pulmonary autograft inclusion into the previously implanted Valsalva graft  Saadallah Tamer,
Dilatation of the pulmonary autograft and native aorta after the Ross procedure: A comprehensive echocardiographic study  Obaid Aljassim, MD, Gunnar Svensson,
Replacement of the Ascending Aorta, Aortic Root, and Valve with a Novel Stentless Valved Conduit  Kelvin K.W. Lau, MRCS, DPhil, Krystyna Bochenek-Klimczyk,
Which Patients Benefit From Stentless Aortic Valve Replacement?
Valve-sparing root repair: V-shaped remodeling can be performed in all sinuses  Paul P. Urbanski, MD, PhD  The Journal of Thoracic and Cardiovascular Surgery 
Novel Technique of Valve-Sparing Aortic Root Replacement in Two Children Younger Than 3 Years of Age  James K. Kirklin, MD, Walter H. Johnson, MD, Barton.
Technique for Reconstruction of the Sinotubular Junction
Aortoplasty for Management of the Dilated Distal Ascending Aorta During Proximal Aortic Reconstruction  Emmanuel A. Amulraj, MD, William D.T. Kent, MD,
Expect the Unexpected: A Bizarre Lookalike of Left Atrial Tumor
Implantation of a mechanical valve within a flexible mitral annular ring  Yuzuru Sakakibara, MD, Yoshiharu Enomoto, MD, Akinobu Sasaki, MD, Motoo Osaka,
Chigozirim N. Ekeke, BS, Curt Daniels, MD, Subha V
Johannes M. Albes, MD, PhD, Ulrich A
Repair follows anatomy
The missing flap: Considerations about a case of aortic intussusception  Eugenio Neri, MD, Gianni Capannini, MD, Enrico Carone, MD, Enrico Tucci, MD, Francesco.
Reversed “C” ministernotomy for aortic valve replacement
Aortic valve repair by sinotubular junctional remodeling to eliminate aortic regurgitation in donor cardiac allograft  David J. Kaczorowski, MD, Y. Joseph.
Leonid Sternik, MD, Kenton J Zehr, MD, Hartzell V Schaff, MD 
A Simple Device for Morphofunctional Evaluation During Aortic Valve-Sparing Surgery  Alessandro Leone, MD, Piergiorgio Bruno, MD, Federico Cammertoni,
Reduction aortoplasty for dilatation of the ascending aorta in patients with bicuspid aortic valve  Matthias Bauer, MD, Miralem Pasic, MD, PhD, Raymond.
Aortic Root Aneurysms: Remodeling or Composite Replacement?
A new approach for proximal anastomosis in type “a” acute aortic dissection: prosthesis eversion  Andrea Rignano, MD, Guido C Keller, MD, Michele Carmo,
Increase in size of the pulmonary autograft after the ross operation in children: Growth or dilation?  Laszlo Solymar, MD, PhD, Göran Südow, MD, Daniel.
Postinfarction ventricular septal rupture: Early repair through the right atrial approach  Massimo Massetti, MD, Gerard Babatasi, MD, PhD, Olivier Le Page,
Replacement of Valve Prosthesis Within Aortic Composite Graft
Long-term durability of resection and end-to-end anastomosis for ascending aortic aneurysms  Massimo Massetti, MD, Sebastien Veron, MD, Eugenio Neri,
Exposure of the mitral valve by transecting the ascending aorta during aortic and mitral valve replacement  V.R Machiraju, MD, Claudio A.B Lima, MD, Michael.
The frozen elephant trunk: An interesting hybrid endovascular-surgical technique to treat complex pathologies of the thoracic aorta  Florian S. Schoenhoff,
Abdominal aneurysm rupture and left main stenosis: Emergency one-stage repair with off-pump coronary surgery  Gerard Babatasi, MD, PhD, Massimo Massetti,
Paul Urbanski, MD, PhD  The Annals of Thoracic Surgery 
Preservation of the Bicuspid Aortic Valve
Composite Valve Graft Replacement of the Aortic Root: Twenty-Seven Years of Experience at One Japanese Center  Tomohiro Tsunekawa, MD, Hitoshi Ogino,
The Florida Sleeve: A New Technique for Aortic Root Remodeling With Preservation of the Aortic Valve and Sinuses  Philip J. Hess, MD, Charles T. Klodell,
Aortic valve exposure through a combined right atrial-ascending aortic approach in redo cases  Antonio M Calafiore, MD, Gabriele Di Giammarco, MD, Giuseppe.
Henry F Tripp, MD, Robert M Stiegel, MD, Joseph P Coyle, MD 
Alternative Technique for the Ostium Primum Defect Repair: A Free Wall Flap of Right Atrium  Massimo Massetti, MD, Gerard Babatasi, MD, Eugenio Neri,
Comparing Aortic Root Replacements: Porcine Bioroots Versus Pericardial Versus Mechanical Composite Roots: Hemodynamic and Ventricular Remodeling at Greater.
Less invasive cardiac operations through a median sternotomy: 100 consecutive cases  Massimo Massetti, MD, Gerard Babatasi, MD, PhD, Anne Lotti, MD, Satar.
Transcutaneous Aortic Valve Implantation Using the Left Carotid Access: Feasibility and Early Clinical Outcomes  Thomas Modine, MD, PhD, Arnaud Sudre,
A special adapted retractor for the mini-sternotomy approach
Hybrid Arch Repair Including Supra-Aortic Debranching on the Descending Aorta  Hideyuki Shimizu, MD, PhD, Takashi Hachiya, MD, Kentaro Yamabe, MD, Ryohei.
The Annals of Thoracic Surgery
Bicuspid Aortic Valves and Dilatation of the Ascending Aorta: Reply
Minoru Tabata, MD, MPH, Hiroo Takayama, MD, Michael E
Aortic root replacement versus aortic valve replacement: a case-match study  Paul P Urbanski, MD, Matthias Wagner, MD, Michael Zacher, MD, Robert W Hacker,
Principles of aortic valve repair
Valve-sparing procedure for dilatation of the autologous pulmonary artery and ascending aorta after the Ross operation  Paolo Masetti, MD, Victor A Davila-Roman,
Presentation transcript:

Aortic root remodeling with the “cuff” technique for stentless valve implantation  Massimo Massetti, MD, Piergiorgio Bruno, MD, Gerard Babatasi, MD, Olivier Le Page, MD, Eugenio Neri, MD, Sebastien Veron, MD, Eric Saloux, MD, Andre Khayat, MD  The Annals of Thoracic Surgery  Volume 71, Issue 3, Pages 1053-1055 (March 2001) DOI: 10.1016/S0003-4975(00)02370-5

Fig 1 The spreading mechanism of the commissures in the presence of dilatation of the sinotubular junction. The Annals of Thoracic Surgery 2001 71, 1053-1055DOI: (10.1016/S0003-4975(00)02370-5)

Fig 2 The sinotubular junction remodeling technique is obtained using a tubular graft inserted as a “cuff” in the proximal extremity of the ascending aorta. The vascular prosthesis is selected in order to reduce the diameter of the sinotubular junction to that of the native annulus. The Annals of Thoracic Surgery 2001 71, 1053-1055DOI: (10.1016/S0003-4975(00)02370-5)