Rodent Resistant Fiber Optic Cables.

Slides:



Advertisements
Similar presentations
Environmental impacts of incidents SPEAKER NAME SPEAKER APPOINTMENT National Contingency Plan – Environment Group Training.
Advertisements

25 pair color code and high count cables
UNDERGROUND CABLES.
Fiber Optics Types Optical fibers are manufactured in three main types: Multi Mode step-index, Multi Mode graded-index, and Single Mode.
LIGHT-DUTY BELT FASTENER SYSTEMS
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
Lecture Goals Slab design reinforcement.
Adela Technology Company Presentation. Introduction Shenzhen Adela was established in 2008, major in fiber optical cable. After many years of development,
Welcome to Flexco ® Rivet Hinged HEAVY-DUTY FASTENER SYSTEMS.
48 FIBRE DUCT OFC ( RIBBON TYPE )
Network IQ Training Manual Chapter 2 - Fibre Optic Cable Types and Manufacturing.
2-4. Solar Panels.
Fiber Optic Cable Installation Indoors Last Update Copyright Kenneth M. Chipps Ph.D. 1.
FIBER OPTIC CABLE CONSTRUCTION
Content :  Indoor fiber optic cables  The benefits of indoor Fiber Optic Cable  The features of indoor Fiber Optic Cable  Tight-Buffered Cable  Consists.
Qualified Partner Program R&Mfreenet fiber - LAN F.O. installation cable Felice Guarna, Training Program Manager Wetzikon, January 2006.
FIBER OPTICS Light propagation through thin glass fibers.
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
INSTALL THE TRANSMISSION LINE By Mohd Nasir bin Said.
RF Signal Cables W. Udo Schröder, 2011 Principles Meas/Electronics 2 RG59/U coaxial cable (BNC) Stiffer than RG58 75 Ohm impedance Dual shielded cable:
Communication channels and transmission media
Fiber Optic splicing process Technology Partners.
Gandhinagar Institute of Technology
Specifying Optical Fiber Cable. Cable Parameters and Typical Values.
OBJECTIVE  INTRODUCTION OF OPTICAL FIBER  CONSTRUCTION OF OPTICAL FIBER  PRINCIPLE OF OPTICAL FIBER  TYPES OF OPTICAL FIBER  OPTICAL FIBER FAULTS.
UNDERGROUND CABLE.
Flexible Load Handling Attachment: Steel Wire rope
Outside Plant Fiber Optics
Study Guide Answers. Electric Field It can travel through empty space and matter.
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
ELECTRICAL WIRE- ARTICLE  Electrical wire in a term used to describe insulated conductors employed to deliver electricity. The.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
4.0 DOMESTIC ELECTRICITY Domestic electricity is that electricity which is supplied to homes under specific conditions of current and voltage. Voltage,
Specifying Optical Fiber Cable
Engineering Technical English Islamic University of Gaza
Presented To: Dr. Ashutosh Bagchi
Chapter 12: Steel Engineering Technical English
An Introduction to Transmission Media
The PV Cell Cell, Module & Array.
Low energy nuclear reaction occurring in hydrogen-loaded nickel wire
Receptacle Housings for M-Style Infinite Switches
CONCRETE PROTECTION MATERIALS & TECHNIQUES
INTRODUCTION.
Gophers By Dominic Tung.
ALPHEUS FLUID TRANSFER SOLUTIONS DOCK HOSE 2017
Electrical Wire for House in Chennai
Permanent Lifting Magnets
Chapter 3 Physical Properties of Materials
Presentation Title Goes Here
Types of Cables.
HEAVY-DUTY FASTENER SYSTEMS
Maser Cable Training Level 1
Metal Framing Kindorf –PL004 SuperStrut –PL005 Cable Tray- PL039
Conductors and Cables 2017 NEC
Govt. Polytechnic,Manesar
Trends on the Periodic Table
Some Facts about Welding Cable
( BDA 3033 ) Chapter 5: Thick Cylinder **Compound Cylinders**
FTTH PRODUCTS INTRODUCTION
Radiation tolerant fibres for LHC controls and communications
EET 323 – Electrical System Design Lecture 6: Conductors and Over-Current Protection Radian Belu, PhD.
POWER SYSTEM-II (III-1)
The Result Of A Lost Line. Where the rubber hits the …roof
Computer Networks Topics: Twisted Pair and Fiber Optic Cable
Self-sealing Cable Transit Panel Project Update
Selection Criteria Properties Availability Cost
July 16, 2019.
CATHODIC PROTECTION OF REINFORCED CONCRETE STRUCTURES
PH0101 Unit 2 Lecture 4 Wave guide Basic features
Fluid Power System Electrical Control
Presentation transcript:

Rodent Resistant Fiber Optic Cables

Introduction Optical fiber cables can be exposed to a number of potential hazards in an indoor or outdoor environment. Damage can occur in a relatively short period of time The type and severity of damage depends upon several factors including species, type of installation/application, and the geographic location. Rodent protection for optical fiber cables is generally based on making it difficult for the animal to gnaw into the cable core. However some rodent protection is based upon making the cable “blend in” with the surroundings. The small diameter of fiber optic cables make them susceptible to gnawing. Diameters typically greater than 19mm (0.75 in) are generally less susceptible to gnawing.

Competition Competitors offer a variety of armoring for rodent protection Corrugated Steel Tape (CST) FRP Steel Wire Nylon Jacket Chemical Repellents Corning offers a dielectric armor in their Mic Cables, but make no statement about them being rodent resistant. They only mention crush resistance. Some competitors state that their interlocked armor cables (ILA) are rated for direct burial and some even state that they are rodent resistant. Most competitors in the industry do not recommend ILA for direct burial Inconsistence in the industry.

Competition Belden lists a percent effective chart for various types of armoring. There is no mention on how they determined the results.

Armoring - OCC CST FRP Bitterant (non-toxic) Braid ILA Excellent: Direct Burial, Aerial, Subterranean Tunnels Caution: Conduit, Cable Tray Not Recommended: Deployable FRP Excellent: Deployable, Subterranean Tunnels, Conduit, Cable Tray Good: Aerial Not Recommended: Direct Burial Bitterant (non-toxic) Excellent: Subterranean Tunnels, Deployable, Conduit, Cable Tray Not Recommended: Aerial, Direct Burial Braid Excellent: Marine Applications Poor: Deployable Not Recommended: Direct Burial, Conduit, Subterranean Tunnels, Aerial, Cable Tray ILA Not Recommended: Any Rodent Protection

Know Your Threat! Most important thing to understand is what will be the threat to the cable. Once you know what the threat is, the correct armoring can be applied. Some armoring works great for certain applications, but some armoring may attract mammals. - Example: Bitterant – May attract Squirrels, but will deter rats/mice Some applications may only require a color change Some examples of threats OCC has came across: Rats, Gophers, Groundhogs, Deer, Monkeys, Termites, Jackals, Rabbits, Dingo’s, Goats, Oryx’s, Possums, Blue Crabs, Marmots, Snowshoe Hares, and Installers…

Know Your Threat! Some installers will do anything to make it look like a cable or rodent issue and not an install issue. Some installers will do anything to make it look like a cable issue and not an install issue.

Direct Burial Only Corrugated Steel Tape (CST) is the only armoring recommended for Direct Burial Designed for use with burrowing and non-burrowing Rodents Non-CST cables do not offer adequate protection from burrowing rodents FRP subjected to Gophers Gopher Ground Hog

Aerial Squirrels are typically the culprit Lashing CST provides best protection Requires Grounding Lashing FRP can be an alternative Bitterant not really recommended for Squirrel resistance Squirrels equate bitter taste to bitter tasting nutshell. They will eat through the bitterant jacket hoping to find a nut inside.

Subterranean Tunnels Rats and Mice are typically found in these locations FRP is used to deter rats and mice Bitterant can be added for further rat and mice resistance LSZH may be required DX series FRP LSZH Riser from 2-12 Fibers, 18-48 fibers with just LSZH DX series CST LSZH Riser from 2-12 Fibers, 18-48 fibers with just LSZH If Burrowing Rodents are present, CST is required

Conduit/Cable Tray FRP CST Rats and Mice are typically found in these locations FRP is used to deter rats and mice Bitterant can be added for further rat and mice resistance DX Series 2-144 fibers with FRP and Riser Rating CST CST Not typically recommended but can be used Increases Diameter (up to 177%) Increases Weight (up to 370%) Increases Tensile Loads Increases Minimum Bend Radius (up to 154%) Decreases the number of cables that can be installed in a single conduit (fill ratio) Decreases crush resistance Attention to detail when attaching a pulling grip

Deployable Dielectric Metallic Wide range of threats in this environment FRP gives maximum protection for deployable surface rodent protection Low Luster V jacket with appropriate color Designed to make cable “blend in” with surroundings (prevent deployable cable appearing like a snake) Coyotes, Jackals, Deer, and other large mammals Bitterant may be added for further resistance Metallic CST and ILA are never recommended Metallic Braid not generally recommended Braid used for Marine Grade applications Defeats purpose of using Fiber Optic Cable Heavy Large Diameter Stiff If you have a customer that mandates metallic Braid or CST, contact OCC Engineering

Termite Resistance Specific threat for selective locations Termites can be very aggressive in attacking an outer jacket DX Series cable Hard Elastomer inner jacket PVC Outer Sacrificial Jacket

Field Trials – Rodent Resistance Nobody in North America testing fiber optic cable rodent resistance with caged rodents OCC conducting field trial. Currently on-going. All cables located at OCC in Roanoke, VA Multiple cable types laid in parallel next to pathway for burrowing rodents Part Number Description Jacket Color Diameter (mm) Bitterant 1 OC-0002818 D-006V, bitterant, Sand Beige Beige 6 Yes 2 OC-0001138 D-012V, bitterant, Sand Beige, FRP 11 3 D-040VWST9KA-M022 D-040V,Bitterant Black 10.3 4 DX012ZWLS9KAB2-MABS DX012Z, Bronze Braid, Z outer jacket 11.5 No 5 DX012DALT9KAF4 DX012D, FRP, D outer jacket DX012DWLS9KAA2 DX012, CST, A outer jacket 13.4 7 Braided TBFUN Prototype TBFUN with R inner jacket, Stainless Steel Braid, V outer jacket 7.1 8 GMTTAZ02 Beldon Tactical Cable 5.48 ? 9 B-002VSLS95KM B-002V Standard Mil Tact 6.5

Field Trials – Rodent Resistance Currently

Field Trials – Critters of the day and night

Field Trials – Critters of the day and night

Field Trials – Critters of the day and night

Field Trials – Critters of the day and night

Questions