Introduction The Gamma Bracing System

Slides:



Advertisements
Similar presentations
Framing.
Advertisements

Roof Trusses Created By M.S.Martin 11/04, reviewed 11/05, reviewed 11/07.
Sectional Assembly and Installation
Dr. Ruth Collins TrinityHaus
Pryda Floor & Rafter Truss Systems
Unit 43 Wall Framing Wood-framed Wall Components • Constructing Wood-framed Walls • Sheathing Exterior Walls • Weather Barriers • Rainscreen Walls • Structural.
Installing Doors & Frames Ref: Handout / Text M. S. Martin Sept
Interior Wall and Ceiling Finish
Unit 8 Fastening Systems
Timber Portal Frame Construction
Unit 45 Metal Framing Industry and Code Regulations • Light-gauge Steel Framing Members • Fasteners • Framing Tools • Metal Framing Safety • Light-gauge.
Cabinet and Countertop Installation
Gable Roofs and Components
CASTING A CONCRETE WALL
Gable Ends, Verge, Eaves & Erection of Gable Roofs
Mezzanine Floor.
Timber Framed Structures
Fitting Door Frames To Cavity Brickwork & Brick Veneer Your Ref: from P11 of text M.S.Martin Sept 2005 M.S.Martin Sept 2005.
Walls Ron Gatepain constructionsite.
Split Sole 45 Degree Raker
Engineering Overview Presenter’s Name
NGfL CYMRU GCaD STRUCTURAL TIMBER FRAMING.
WALL FRAMING Section 6 of AS 1684 relates to the regulations governing timber wall construction.
Unit 42 Floor Framing Floor Unit Resting on Sill Plates • Floor Unit Resting on Cripple Walls • Posts and Beams • Floor Joists • Subfloor • Floor Underlayment.
QUINN TRUSS OPEN WEB JOIST SYSTEM TECHNICAL DETAILS.
Ledgewood Farm greenhouse construction How do I Start? to I’m Finished!
2 Post Vertical Shore/Laced Post
Chapter 20 Cladding with Masonry & Concrete
Wall plate should measure the insertion point height plus 30” to accommodate a 30” cleat. The 30” cleat receives 20 X 16d nails. Cut the wall plate and.
After the foundations have been completed the walls are set out and construction commences. wall structures.
Solid Sole 60 Degree Raker
Case Study – St Clair Park Village, Auckland, NZ
Wall and Ceiling Construction Vocabulary
Topic C1 Superstructures - walls
Building Types.
BUILDING CONSTRUCTION V ARCHITECTURAL FINISHING SYSTEMS
Construction Residential Houses Definition of a House: A structure serving as a dwelling for one or more persons, especially for a family.
Installation. Indoor Unit Installation Typical Installation.
Introduction The Gamma Bracing System  Gamma bracing system is a light weight steel, structural truss bracing frame that fits INSIDE the timber studs.
Wall and Ceiling Construction
Structural Components
1 Building Types. 2 Building Use and Size Buildings are available in many types and sizes. Large, specialized buildings should be planned and built by.
1 Presented by the Wood Truss Council of America.
Roof and Ceiling Framing
SHREE J.M.SABVA INSTITUTE OF ENGINEERING &TECHNOLOGY, BOTAD 1.BELADIYA VISHAL R. 2.PARMAR PRAKASH K. 3.DESAI PARAS V. 4.PARMAR VISHAL D. 5.GOHEL KAMLESH.
Residential Construction Mr. Todzia
BUILDING THE FRAME Walls are constructed in sections, lying down on the floor platform and then tilted up into position. Fundamentals of Building Construction,
Wood Construction CTC-375.
Lecture 15 - Timber Wall Framing Example
QuickWalls® strong. fast. simple. *Light Weight *Insulated
Learning Outcome Lesson Objective
Potting Bench Plans Matt Howell Brooks County High School ___, Georgia Georgia Agricultural Education Curriculum Office, August, 2004.
Potting Bench Plans Matt Howell Brooks County High School Quitman, Georgia Quitman, Georgia Georgia Agricultural Education Curriculum Office, August, 2004.
Mezzanine Build Plans.
VIEW SERIES with Sliding Door
Regulation and compliance with performance standards
UPPER FLOORS TIMBER AND CONCRETE.
Objectives Describe the fasteners, anchors, and adhesives used in construction and explain their uses. f. Identify various types of mechanical anchors.
Competency: Draw wall sections and details
Pritesh h prajapati Arvind g prajapati Arvind m prajapati Arvind khata.
•Connecting to the Foundation & Bearing
Wood structures Topic 3 Floor Framing
Wood Structures Topic 8 Quality Workmanship
Building Construction I Sofia Sebastian 1
171-SH SH Box with Pre-Installed 101⁄2" Pigtail Popular 4" square boxes and switch boxes Pre-installed 101⁄2" insulated grounding.
Competency: Draw wall sections and details
STRUCTURAL TIMBER FRAMING
Unit 8 Floor Framing.
Product Information Applications Installation Guide
Introduction The Gamma Bracing System
Presentation transcript:

Introduction The Gamma Bracing System Gamma bracing system is a light weight steel, structural truss bracing frame that fits INSIDE the timber studs and between the top and bottom plates. And is designed to provide structural bracing performance for timber framed constructions Gamma bracing frames are ideally suited for New or Existing constructions or the refurbishment of existing buildings that have suffered trauma & Leaky Building syndrome.

Gamma Testing Gamma bracing frames have been fully tested and accordance with NZS3604: 2011 P21[2010] Racking Test method for use in New Zealand 3

Gamma Certification Independent Structural Engineer to review testing. Can also provide expert technical support . Structural design work

Gamma Technical Literature Gamma Technical Installation Manual. Details how to install Performance details Details required components Hold Down requirements

Gamma Performance Gamma Performance Gamma bracing frames provide up to 80BU for wind (130BU/m) Gamma bracing frames provide up to 90BU for earthquake (150BU/m) Gamma Performance Gamma system Reference Wind (BU’s) Earthquake (BU’s) GBF400/2.4 45 GBF400/2.7 40 GBF400/3.0 35 GBF535G/2.4 69 75 GBF600/2.4 80 90 GBF600/2.7 70 GBF600/3.0 55 60

Gamma Software Calculator Gamma bracing calculator software available from the Gamma web site www.gammabracing.co.nz Calculates Demand and Achieved The Gamma Bracing software is flexible and allows the user to include other bracing products and systems. Archicad Architectural design software available

Gamma Installation Establish the position of the Gamma frames within the building. Can be installed at Pre-nail frame stage. Directly onsite Can be installed from the outside when the cladding is removed. Or from the inside when the lining is removed. In wet areas (bathrooms etc) Gamma frames are 45mm in depth leaving space for cross noggins

Gamma Installation Mark hole positions on bottom plate and drill through into floor to the required depth. Then fit the Gamma frame. Ensure the holes are free from debris and insert the Masonry screw. Place the washer over the bracket.

Gamma Installation Insert the impact socket extension drive through the access hole in the lower part of the frame and impact drive the bolt into the concrete.

Gamma Installation

‘J” Bolt set into concrete Gamma Hold-Down Anchor Requirements Hold-down Anchors Floor Type Wall Type Anchor Type Uplift Capacity Concrete External Wall Masonry Screw 15kN Chemical Set Anchor ‘J” Bolt set into concrete Internal Wall Expansion bolt Timber External/Internal M12 x 200mm Coach Screws 12kN

Gamma Installation (Concrete Floors) For external walls on concrete floors position the Gamma frame flush with the inside face of the timber framing to achieve the maximum edge distance for the Hold-Down anchor. (Min Edge distance 60mm). For internal walls the Gamma frames can be positioned anywhere within the framing

Gamma Installation (Timber Floors) For external walls on timber floors position the Gamma frame to ensure that the Hold-Down anchors are fastened into solid blocking.

Gamma Installation - Insulation Install insulation to all cavities within the Gamma frame No issue with thermal loss or conductivity (Gamma frames are 45mm in depth) Pre cut installation packs are available from most insulation suppliers Bradford Styrobeck EcoFleece Expol Pink Batts

Installation of Gamma Frames Gamma frames deliver the specific engineering bracing units to the structure immediately they are installed. Gamma bracing frames can be used in conjunction with other bracing systems Gamma frames have service access holes pre punched. Any modifications to the Gamma frame are not permitted Installation diagram provided with each frame along with fixing screws & washers. Install the interior linings as per AS/NZS 2589. No plasterboard bracing fixing patterns are required Timber moisture levels do NOT need to be less than 18% before Gamma fames are installed. This allows early structural integrity to the building.

Installation of Gamma Frames Gamma bracing frames can accommodate stud centers of 400, 450 & 600mm & various stud heights using timber blocking.

Installation of Gamma Frames GBF535G/2.4 – Gamma GBF400 frame with double studs either side.

Installation of Gamma Frames New building code requirements require LBP to install structural bracing elements. GAMMA bracing systems are flexible for designers and easily incorporated into the building design. GAMMA’S are permanent structural members not easily destroyed with DIY projects.

Gamma – Outstanding Performance Gamma bracing frames provide a highly ductile and robust structural bracing system and will continue to provide structural service post event allowing dwellings to be re-habitable. The Gamma bracing frame maintains increased performances even when taken well past the recommended test deflection limits in the P21 [2010] test procedure. Gamma bracing frame withstood multiple consecutive P21 Racking tests with only a very minimal drop of in performance compared with the first test. This proved that the Gamma is extremely robust and durable.

Gamma – Key Build Cost Savings Pre-Nail installation requires the Gamma frame to be simply dropped in between the studs and 4 x Hex head screws installed. Installing Gamma bracing frames is easy and cost effective No requirement for temporary bracing (Labour & Material) No Structural Plywood or Plasterboard Bracing lining boards required. Bracing completed once framing is erected and Gamma frame installation is completed. No post line Council inspection required. Installation of the interior linings quicker, easier and can be carried out once the build is fully enclosed. Reduced issues with plasterboard joint peaking and fastener popping.

Thank You