Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2

Slides:



Advertisements
Similar presentations
Combined Measurement Results of dedicated RD50 Charge Multiplication Sensors Christopher Betancourt 2, Tom Barber 2, Gianluigi Casse 1, Paul Dervan 1,
Advertisements

Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
30 th March 2010 IoP HEPP/APP Annual Conference 2010 UCL Charge Collection Annealing in ATLAS SCT Silicon Sensors Craig Wiglesworth.
1AIDA final meeting, CERN 9-11 December 2014 Vladimir Cindro, Jožef Stefan Institute Transnational access to TRIGA _Mark III reactor at Jožef Stefan Institute,
TCT+, eTCT and I-DLTS measurement setups at the CERN SSD Lab
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
1 Integrating Radiation Monitoring System for the ATLAS Detector at the Large Hadron Collider Igor Mandić 1, Vladimir Cindro 1, Gregor Kramberger 1 and.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Study of leakage current and effective dopant concentration in irradiated epi-Si detectors I. Dolenc, V. Cindro, G. Kramberger, I. Mandić, M. Mikuž Jožef.
ALBA Synchrotron – 17 June 2010 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona First Measurements on 3D Strips Detectors.
Edge-TCT and Alibava measurements with pion and neutron irradiated micro-strip detectors V. Cindro 1, G. Kramberger 1, I. Mandić 1, M. Mikuž 1,2, M. Milovanović.
Online Radiation Dose Measurement System for ATLAS experiment I. Mandić a, V. Cindro a, I. Dolenc a, A. Gorišek a, G. Kramberger a, M. Mikuž a,b, J. Hartert.
Approach of JSI to field modeling Gregor Kramberger (more details 19 th RD50 CERN, Vertex 2012 proceedings)
RD50 RD50 workshop FreiburgKatharina Kaska 1 Determination of depletion voltage from CV, IV and CCE measurements on Pad Detectors Katharina Kaska, Michael.
1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Charge Collection Study of Heavily Irradiated Silicon Microstrip Detectors Chris Lucas (University of Bristol) Irena Dolenc Kittelmann, Michael Moll, Nicola.
Update on Micron productions - Comparison of AC & DC coupled devices - Marko Milovanovic*, Phil Allport, Gianluigi Casse, Sergey Burdin, Paul Dervan, Ilya.
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Analysis of Edge and Surface TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewart a, R. Bates a, C. Corral b, M. Fantoba b, G. Kramberger c, G.
October, 2001CMS Tracker Electronics1 Module studies at IC OUTLINE laboratory setup description, APV I2C settings pulse shape studies (dependence on ISHA,
Effects of long term annealing in p-type strip detectors irradiated with neutrons to Φ eq =1·10 16 cm -2, investigated by Edge-TCT V. Cindro 1, G. Kramberger.
23 th November 2010 Possibly relevant new from RD50 G. Casse.
1/14 Characterization of P-type Silicon Detectors Irradiated with Neutrons M.Miñano 1, J.P.Balbuena 2, C. García 1, S.González 1, C.Lacasta 1, V.Lacuesta.
Calibration of the gain and measurement of the noise for the apv25 electronics K. Gnanvo, N. Liyanage, C.Gu, K. Saenboonruang From INFN Italy: E. Cisbani,
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
Edge-TCT studies of heavily irradiated strip detectors V. Cindro 1, G. Kramberger 1, A. Macchiolo 3, I. Mandić 1, M. Mikuž 1,2, M. Milovanović 1, P. Weigell.
Annealing of CCE in HPK strip detectors irradiated with pions and neutrons Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko.
A CCE and TCT Study on low resistivity MCz p-on-n detectors Nicola Pacifico, Michael Moll, Manuel Fahrer 16 th RD50 workshop, Barcellona, 31 May-2 June.
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
CNM double-sided 3D strip detectors before and after neutron irradiation Celeste Fleta, Richard Bates, Chris Parkes, David Pennicard, Lars Eklund (University.
Charge Collection, Power, and Annealing Behaviour of Planar Silicon Detectors after Reactor Neutron, Pion and Proton Doses up to 1.6×10 16 n eq cm -2 A.
Study on and 150  m thick p-type Epitaxial silicon pad detectors irradiated with protons and neutrons Eduardo del Castillo Sanchez, Manuel Fahrer,
Summary of Liverpool CC(V) Measurements A. Affolder, P. Allport, H. Brown, G. Casse, V. Chmill, D. Forshaw, T. Huse, I. Tsurin, M. Wormold University of.
RD50 RD50 Workhop: CERN Katharina Kaska Epitaxial silicon detectors irradiated with protons and neutrons Katharina Kaska, Michael Moll RD50 Workshop.
TCT measurements with irradiated strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž.
Trench detectors for enhanced charge multiplication G. Casse, D. Forshaw, M. Lozano, G. Pellegrini G. Casse, 7th Trento Meeting - 29/02 Ljubljana1.
Comparison of the AC and DC coupled pixels sensors read out with FE-I4 electronics Gianluigi Casse*, Marko Milovanovic, Paul Dervan, Ilya Tsurin 22/06/20161.
Annealing effects in irradiated HPK strip detectors measured with SCT128 chip Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1,Gregor Kramberger 1, Marko.
Annealing effects in irradiated HPK strip detectors measured with SCT128 chip Igor Mandić 1, Vladimir Cindro 1, Gregor Kramberger 1, Marko Zavrtanik 1,
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
0 Characterization studies of the detector modules for the CBM Silicon Tracking System J.Heuser 1, V.Kyva 2, H.Malygina 2,3, I.Panasenko 2 V.Pugatch 2,
Marko Milovanović, ESR P3 – Radiation Hard Crystals / 3D Detectors Home country: Serbia, MSc in electrical engineering at the University of Nis (2007)
Investigation of the effects of thickness, pitch and manufacturer on charge multiplication properties of highly irradiated n-in-p FZ silicon strips A.
E-TCT measurements with laser beam directed parallel to strips Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Mikuž 1,2,
TCT measurements of HV-CMOS test structures irradiated with neutrons I. Mandić 1, G. Kramberger 1, V. Cindro 1, A. Gorišek 1, B. Hiti 1, M. Mikuž 1,2,
24/02/2010Richard Bates, 5th Trento workshop, Manchester1 Irradiation studies of CNM double sided 3D detectors a. Richard Bates, C. Parkes, G. Stewart.
RD50 CCE measurements and annealing studies on proton irradiated p-type MCz diodes Herbert Hoedlmosera, Michael Molla, Michael Koehlerb, Henri Nordlundc.
Radiation damage studies in LGAD detectors from recent CNM and FBK run
G. Kramberger, V. Cindro, I. Mandić,
Accelerated annealing with mixed irradiated detector
Charge collection studies with irradiated CMOS detectors
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
Position Sensitive TCT Measurements with 3D-stc detectors
Studies on TH2 chamber Michele, Maria, Givi, Joerg
A. Affolder, P. Allport, G. Casse University of Liverpool
Setup for measurements with SCT128 in Ljubljana: SCTA128VG chip
Magnetoresistance in the irradiated Si microstrip type samples
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Status of the CERN ALIBAVA System
BESIII EMC electronics
Vladimir Cindro, RD50 Workshop, Prague, June 26-28, 2006
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
CCE measurements with Epi-Si detectors
CCE/CV measurements with irradiated p-type MCz diodes
Setup for testing LHCb Inner Tracker Modules
Presentation transcript:

Measurement of charge collection in p-type microstrip sensors with SCT128 chip Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2 1Jožef Stefan Institute, Ljubljana, Slovenia 2 Faculty of Mathematics and Physics, University of Ljubljana, Slovenia I. Mandić, 3rd Workshop on Advanced Si Detectors , Barcelona, June 2008

Setup for measurements with SCT128 chip was built in Ljubljana: SCTA128VG chip drawings of test pcb from CERN (thanks to Jan Kaplon) VME module SEQSI (for clock, commands...) Tektronix digital scope for data acquisition Cambridge LabView software for chip control (thanks to Dave Robinson) data acquisition software (thanks to G. Kramberger ) pitch adapters from Freiburg (thanks to Uli Parzefal) coincidence circuit made by Erik Margan 90Sr source, photomultiplier, scintillator, power supplies.... I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

Test PCB Detector (1.2x1.2 cm2) SCTA128VG Fanin Al detector support and heat spreader PT100 I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

Scintillator is under the Aluminium support structure dimensions: ~ 25 cm x 20 cm x 6 cm 90Sr source is inserted into the upper collimator Test board holder Scintillator is under the lower collimator Photo Multiplier Light guide I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

Setup in the fridge, temperature about - 20° C 90Sr source holder I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

charge sensitive front-end amplifier with about 20 ns peaking time SCTA128VG chip 128 channels charge sensitive front-end amplifier with about 20 ns peaking time sampled every 25 ns (40 MHz sampling clock) Gain = 26.5 mV/fC = 4.2 µV/el measured with calibration signals from on-chip capacitors (~10 % accuracy) noise with detector connected ~ 800 el Strips bonded I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

p-type, FZ material, 300 µm thick strip detectors strip pitch 80 µm n-in-p capacitively coupled polysilicon biased, p-sprayed designed by Liverpool, produced by Micron Semiconductor, sent to us by Gianluigi Casse I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

1 MeV equivalent fluences (same fluence steps as for Liverpool): Irradiations detectors were irradiated with neutrons in the TRIGA reactor in Ljubljana 1 MeV equivalent fluences (same fluence steps as for Liverpool): 5·1014 n/cm2 1.6·1015 n/cm2 3·1015 n/cm2 after irradiation detectors were annealed for 80 minutes at 60° C I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

fitted with convolution of Landau and Gauss functions Measurements trigger: signals caused by electrons from 90Sr source in scintillator in coincidence with 40 MHz clock edge spectrum of signals from strips (pedestals and common mode variations subtracted) fitted with convolution of Landau and Gauss functions  “Most Probable Value” of the Landau function (parameter p1 in the plot below) returned by the fit is the measure of collected charge Bias = 350 V I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

measurements taken at -20° C statistical error of points ~ 5% Signal vs. Bias Voltage measurements taken at -20° C statistical error of points ~ 5% highest voltage limited by breakdown repeats of measurements are shown at two highest fluences (reproducibility test) I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

Comparison of spectra in which MP ~ 20 kel measured after different fluences (normalized to the equal number of clusters in histogram) signals at high voltage after irradiation as high as before irradiation I < 1 µA I ~ 20 µA I ~ 400 µA I ~ 250 µA (better cooling) I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

good agreement with Liverpool results Signal vs. Fluence good agreement with Liverpool results with present cabling in ATLAS the highest voltage is 500 V it seems that higher bias voltage would help I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

after very high fluence detectos can be operated under forward bias Ф = 1.6·1015 n/cm2, T ~ -40° C (a cup of liquid N2 put into the fridge) Bias = +300 V, I = 200 µA, MPV = 10 kel Reverse bias ~ -600 V needed for same MPV, but much lower current (less than 10 µA at this T) Ф = 3·1015 n/cm2, T ~ -24° C, Bias = +400 V, I = 600 µA, MPV = 6.5 kel Reverse bias ~ -600 V needed for same MPV, but much lower current (35 µA at this T) I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

were measured with SCT128 chip Conclusions signals caused by fast electrons from 90Sr source in p-type microstrip detectors were measured with SCT128 chip measurements were made up to very high bias voltages (max.1700 V) CCE as high as before irradiation measured at sufficiently high voltage in detectors irradiated up to Ф = 3·1015 n/cm2 good agreement with measurements from Liverpool I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

Modul 0, Фeq = 0 n/cm2, exposed to few Mrads of gammas Backup plots Modul 0, Фeq = 0 n/cm2, exposed to few Mrads of gammas I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

Number of strips per cluster Ф = 0, Bias = 350 V Ф = 5e14, Bias = 800 V Ф = 1.6e15, Bias = 1100 V Ф = 3e15, Bias = 1600 V I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

Number of strips per cluster forward bias Ф = 3e15, Bias = +400 V Ф = 1.6e15, Bias = +300 V I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

signal mean vs. trigger delay, before irradiation Bias = 200 V Pulse shape signal mean vs. trigger delay, before irradiation Bias = 200 V I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008

measurements for which MPV ~ 20000 el Signal to noise measurements for which MPV ~ 20000 el I. Mandić, 3rd Workshop on Advanced Si. Detectors , Barcelona, June 2008