An Electrooculography Prosthetic Control System

Slides:



Advertisements
Similar presentations
Project leader: Benjamin Danziger, EE Todd Bentley, ISE Jim Corcoran, CE Jay Radhakrishnan, EE Peter Drexel, EE Vianna Mullar, EE.
Advertisements

Team Members:  Kyle Bloomer  Josh Geiman  Lucas Bennett Team Sponsor:  Dr. Cindy Harnett Team Mentor:  Dr. Andy Dozier.
In this presentation you will:
Team 7: Automated Retracting Coaster (ARC) Slide
No More Peg Legs and Hooks Better Prosthetic Design through Engineering.
GROUP 7 THOMAS BLASCHAK JOSHUA DAVIS ANTHONY HOMCHENKO CHARLES HUPP NANABAYIN WILSON SMART WHEELCHAIR.
Catheter Guidewire Control System Derek Carlson & Caleb Anderson Advisors: Dr. Dempsey & Dr. Stewart.
The Advanced Prosthetic Hand Project Jessica Reddy, IMSURE Fellow Mentor: Dr. William C. Tang.
Energy Smart Room GROUP 9 PRESENTERS DEMO DATE SPECIAL THANKS TO ADVISOR PRESENTERS Thursday April 19, 2007 Department of Electrical and Systems Engineering.
Hardware-In-The-Loop Testbed Team 186: Douglas Pence, Ken Gobin, Aaron Eaddy, Advisor Sung Yeul Park Department of Electrical and Computer Engineering,
Electrical and Computer Engineering Personal Head-Up Display Ivan Bercovich Radu-Andrei Ivan Jeff Little Felipe Vilas-Boas Faculty: Dr. Tilman Wolf Midway.
HI-WIRE Haptic Interface With Intuitive Robot Control.
Wearable Sensors Final Presentation Problem Background Inferred Transmission (short range) Bulky Design, hard to wear 20 Samples per second.
Cullen College of Engineering RFID-Based Solutions for Piping Technology Piping Tech & UH July, 2007.
INDIAN INSTITUTE OF TECHNOLOGY MADRAS Department of Engineering Design AUTONOMOUS UNDERWATER ROBOTIC LABORATORY Researchers : Dr. Asokan Thondiyath, Mr.
1 Department of Electrical and Computer Engineering Advisor: Professor Hollot Team RCA March 1, 2013 Cumulative Design Review.
Mobile Controlled Car Students : Tasneem J. Hamayel Hanan I. Mansour Supervisor : Dr.Aladdin.
Traumatic Brain Injury Eyewear “TB-Eye” Todd Biesiadecki, Matthew Campbell, Matthew Vildzius ECE4007 L03 EM1 Advisor: Erick Maxwell December 14, 2011.
Pediatric Dynamometer ABSTRACT The Children’s Hospital of the University of Pennsylvania has long been involved with the study of the correlation between.
P12015 This material is based upon work supported by the National Science Foundation under Award No. BES Any opinions, findings, and conclusions.
Easel 5000 New Adjustable Easel. Overview  Introduction  Project Description  Market Analysis  Similar Patents  Preliminary Designs  Optimal Design.
Team 03 Department of Electrical and Computer Engineering 6 March 2015 Digital Fitness Trainer CDR.
Traumatic Brain Injury Eyewear “TB-Eye” Todd Biesiadecki, Matthew Campbell, Matthew Vildzius ECE4007 L03 EM1 Advisor: Erick Maxwell October 31, 2011.
Daredevil Robot Direction Module (DRDM) Senior Design II Midterm Presentation.
ECE 477 DESIGN REVIEW TEAM 3  SPRING 2015 Garrett Bernichon Bryan Marquet John Skubic Tim Trippel.
ECE 477 Final Presentation Team 1  Spring 2013 Zelun Tie Xin Jin Ranmin Chen Hang Xie.
What is a Microprocessor ? A microprocessor consists of an ALU to perform arithmetic and logic manipulations, registers, and a control unit Its has some.
Daredevil Robot Direction Module (DRDM) Senior Design II Final Presentation.
IN 1900 ICT Project Final Presentation. Group name : Code Squad.
PROSTHETIC LEG PRESENTED BY:-AWAIS IJAZ HASNAT AHMED KHAN.
Electrical and Computer Engineering Preliminary Design Review Team 22: Driver Assist.
BANDAGE SIZE NON ECG HEART RATE MONITOR USING ZIGBEE WIRELESS LINK Guided by,Presented by, Ms. Geo. P.G Jeevan.K.Noble Asst.Prof., ECE Dept.S7, ECE-A.
P07122: Autonomous Quadcopter Jason Enslin – EE: Team Leader, Circuit Design/Testing Glenn Kitchell – CE: Programming, Software Design Richard Nichols.
Preliminary Design Review Team 18 October XX, 2015 Department of Electrical and Computer EngineeringAdvisor: Csaba Andras Moritz.
The entire system was tested in a small swimming pool. The fully constructed submarine is shown in Fig. 14. The only hardware that was not on the submarine.
A Mini project on “DRIVERLESS TRAIN ENGINE USING 8051 MICROCONTROLLER” GUIDED BY K.RAMBABU.
Creating a 3D Printed Hand Prosthetic Georgia Donaldson Mr. Spangler Whitefish High School Advanced Chemistry.
Voice Controlled Robot by Cell Phone with Android App
XBee Based Motor Control for Farmers
Obstacle avoiding robot { pixel }
The History of ARM and Microcontrollers Chapter 1
Nicole Chan Eric Westman
Home automation using Arduino & ‘PIR sensor’
BlooDragu: Enhancing Motor Skills with Robotic Arm
EMG-HUMAN MACHINE INTERFACE SYSTEM
Smart Shoe S Seminar 2 Prepared by: Sa’ed Qariab Mos’ab Naffa’a
Microcontroller Enhancement Design Project
Deep Blue Brain Drone Introduction Brain Drone Components Purpose
Brain operated wheelchair
Automatic human detector garbage can.
Outline Introduction Standards Project General Idea
FINAL YEAR PROJECT 1 WPB49804 Development of arm gesture device
WIRELESS ENERGY MEASUREMENT SYSTEM
Advised by Professor Baird Soules
BTY100-Lec#6.3 Biomedical Engineering Bionics.
Introduction to robotics
Cumulative Design Review
Computer Integrated Manufacturing ( CIM). Chapter One 1.1 Introduction 1.2 Types of Manufacturing 1.3 CIM Hardware and CIM Software 1.4 Nature and Role.
Design and Implementation of an Automated Conveyor Line
James Sigler, Mohammed Allahyani, Khalid Alghamdi, Yu Sun
The EZG Portable | Easy to Use | Comfortable | Lightweight | Accurate | Versatile | Safe Structure of Prototype: Electrodes connect via snap leads to wings.
Fig. 2: Internal Components
ELECTRONIC AUTOMATIC TRANSMISSION FOR BICYCLE TA – HERSHEL REGE
M.A.D. Sleeve Muscular Atrophy Detection
P17001: Wearable Interface Design Iterations Team Intro & Background
ECE 791 Senior Project Proposal Advisors: Professor Wayne Smith
A Radio Frequency IDentification (RFID) Prosthetic Control System
Ocular Prosthesis Team Members: Adam Lee, EE Faculty Advisors:
SandWish Automated Tabletop Sandwich Maker
P19045 Essential Tremor Test Rig II Final Review April 7th, 2019
Presentation transcript:

An Electrooculography Prosthetic Control System Walker Arce1,2, Jorge Zuniga Ph.D.1 1Department of Biomechanics, University of Omaha, NE, USA 2Department of Electrical and Computer Engineering, University of Omaha, NE, USA ABSTRACT RESULTS METHODS Printed Circuit Board: A printed circuit board that fits the footprint of the MyoWare Muscle Sensor was developed utilizing EAGLE EDA that incorporates all necessary components from the block diagram for the system. The PCB is a two layer board that measures 0.82x2.06 inches. Software: The Arduino development environment was used to develop the software as the ATmega328P was compatible with this software. AVR Studio 7 and an AVR ISP MKII was used to program the microcontroller. Power Testing: A 30V 10A power supply was used to perform power testing along with a TekPower USB multimeter to collect the current measurement results. A Matlab script was developed to simulate multiple grip events over a period of time to be able to capture the battery life of the device over a period of use. In addition the battery life of the device on multiple sized lithium polymer batteries was calculated using this script. Cost: The developed device was designed to use low cost components that can be easily integrated into a small footprint. The components were also sourced to allow for easy purchase of the bill of materials in the United States. For many surface EMG (sEMG) prosthetic control systems, the muscles on the affected limb are used to trigger the control system. This can lead to fatigue in the user as they have to maintain continuous muscle activation and coactivation in order to achieve prosthetic control [3]. The crux of any prosthetic control system is the human machine interface that is developed, and at present many control systems have complicated interfaces that limit the degrees of freedom of the prosthetics. This study focuses on the development of a low-cost prosthetic control peripheral that is compatible with the prosthetics developed by Dr. Zuniga and his research team. To simplify this interface, a simple, low-cost, low-profile, wearable platform was developed with an off-the-shelf MyoWare Muscle Sensor to allow for custom commands to be sent to a prosthetic control board. The printed circuit board (PCB) was designed using EAGLE EDA and incorporates a battery, with charging circuit, dedicated power supply, microcontroller, and a MyoWare. This is shown in figures one and two. The power consumption of the device was measured and the battery life was calculated for six different battery sizes over a twelve hour period. A standard battery life equation was used for this. The data collected during this study is shown below and was analyzed using the aforementioned Matlab script. Battery Life (Hours) Number of Trigger Events in a Twelve Hour Period Battery Sizes (mAh) 250 500 1000 2000 3000 4000 5000 6000 7000 6.62 6.60 6.55 6.46 6.38 6.29 6.21 6.13 6.05 400 10.59 10.56 10.49 10.34 10.20 10.06 9.93 9.81 9.68 13.24 13.20 13.11 12.93 12.76 12.58 12.42 12.26 12.10 1200 31.78 31.67 31.46 31.03 30.61 30.19 29.80 29.42 29.04 52.97 52.79 52.43 51.72 51.02 50.32 49.66 49.04 48.39 2500 66.21 65.99 65.54 64.65 63.78 62.90 62.08 61.30 60.49 Trigger Events Average Current (mA) 500 26.43 1000 26.52 2000 26.7 4000 27.07 6000 27.44 8000 27.82 10000 28.19 12000 28.55 14000 28.93 INTRODUCTION MATERIALS With the development of low-cost biometric sensors and accessible microcontroller platforms on the market, the options for prosthetic control systems increases significantly [1]. Unfortunately, electronic prosthetic devices are too expensive for most prosthetic users to afford, which has lead to the creation of 3D printed prosthetic devices such as the ones from Dr. Zuniga et al [2]. Surface EMG (sEMG) remains one of the pivotal control mechanisms for prosthetic control systems, but using the affected limb’s muscle activation for the control system can lead to fatigue [3]. To prevent this, electrooculography (EOG) can be used to send actuation controls to a prosthetic control board [4]. To be comfortable for a user to wear, the electrodes need to be discrete and the device needs to be lightweight. The purpose of this study was to create a simple daughter board for the MyoWare that can fulfill these requirements. To this end, a low-cost, sEMG peripheral was developed that acts as a full processing front-end for the MyoWare Muscle Sensor. The developed PCB was ordered from JLCPCB (JLCPCB, Shenzhen, China) and were populated by hand for the study. The prosthesis this control board was designed to interface with is the hybrid actuation prosthetic arm with two PQ12 motors integrated into the socket. The motors were driven at 12V to optimize the torque produced for each motor. In addition, a 500mAh lithium polymer battery was used for testing the device. The low-cost 3D printers used in this study were the Ultimaker 2 Extended+ (Ultimaker B.V., Geldermalsen, The Netherlands). The materials for printing the prostheses were polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS). Other components of the prostheses included: 1 mm nylon lift cord, 1.5 mm diameter elastic cord, Velcro, medical-grade firm padded foam, a protective skin sock, and a BOA dial tensioner system. The final completed system is compatible with any control board that utilizes Bluetooth as a communication protocol. The data generated for this study was completed using a dedicated power supply to test the Operating requirements of the device. Figure 3: The graphed results of the Matlab processing script. CONCLUSION The device developed in this study was promising and warrants future study as an alternative prosthetic mode of control. REFERENCES Lake, Christopher & Miguelez, John M., 2003, ‘Evolution of microprocessor based control systems in upper extremity prosthetics,’ Technology and Disability 15, Advanced Arm Dynamics of Texas, Dallas, TX. Zuniga, J, et al. (2015), doi:10.1186/s13104-015-0971-9 Zecca, M., et al. (2017). Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal. Critical Reviews in Biomedical Engineering, 45(1-6), 383-410. doi:10.1615/critrevbiomedeng.v45.i1-6.150 Duvinage, M., Castermans, T., & Dutoit, T. (2011). Control of a lower limb active prosthesis with eye movement sequences. 2011 IEEE Symposium on Computational Intelligence, Cognitive Algorithms, Mind, and Brain (CCMB). doi:10.1109/ccmb.2011.5952116 Figure 1: Block diagram of the EOG control system. The USB interface is used to reprogram the on-board microcontroller and provide charge to the battery. The power supply is achieved using a 2A low PSRR LDO. The microcontroller was satisfied with an ATmega328P that interfaced to the MyoWare Muscle Sensor. The Bluetooth device used was an HM-11 for sending signal to a remote device. Figure 2: The developed custom control board.