SISTEMA Example Three.

Slides:



Advertisements
Similar presentations
Masterclass 2001: Safety Integrated Excellencein Automation&Drives: Siemens Folienthema/Folie 1/Jahreszahl Name & Department AS-Interface Safety now included!
Advertisements

SISTEMA Examples.
/// MELSEC Safety /// QS001CPU /// QS0J61BT12 /// QS0J65BTB2-12DT /// MELSEC Safety /// Mitsubishi Electric - MELSEC Safety - Training Documentation -
Three-Phase AC machines
HVAC Commercial Ref.
HYDRAULICS & PNEUMATICS
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Shielding Workshop S. Buda Personnel Protective Systems March 27, 2007.
Rexroth IndraDrive Integrated Safety Technology
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
©Ian Sommerville 2004Software Engineering, 7th edition. Chapter 15 Slide 1 Real-time Systems 2.
Elec467 Power Machines & Transformers
4/24/05 BAE Motor Control PLCs and Ladder Logic An Introduction.
Prepared By: Certified Compliance Solutions, Inc. August 2012
Simply easy! TM XUSL2E/4E light curtains Pilot light ? How to provide a signal to a pilot light or to a PLC input.
1 Week 11 SYSTEM SAFETY Matakuliah: Mechatronics 2 Tahun: 2005 Versi: 1.0/0.
Electrical Safety Training
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
Logic Operations in Electro-Pneumatics
Control of Pneumatic Energy
Section 4: Electric Motors
Timers.
1 EXPERIENCE AND RELIABILITY. 2 Short circuit loop measurements EN EN
SISTEMA Example One. Schneider Electric – Sistema Example 1 – June Example 1: Start/Stop Facility with Emergency Stop Device Circuit Diagram.
SISTEMA Example Two. Schneider Electric – Areva D Acquisition – June Example 2: Safe stopping of a PLC-driven drive with emergency stop – Category.
Troubleshooting Electric Control Devices
10.2: Electricity and Electric Circuits. Static vs. Current Electricity Static Electricity: charges build up in one location Current Electricity: electrons.
The Control of Electricity in Circuits
Electrical Installation 2
Electrical Power Systems
Electrical Distribution Training
Control Technology and Automation
Schematic Diagrams & Circuits
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
Current Electricity and Electric Circuits. Static vs. Current Electricity Static Electricity: charges build up in one location Current Electricity: electrons.
SISTEMA Example Four.
Introduction to SISTEMA. Schneider Electric 2 - Mac - Safety – March 2010 Introduction ●Introduction In Europe: ●Manufacturers are used to designing the.
8.2 ELECTRIC CURRENT BC Science 9: p Electric Circuit An electric circuit is a complete pathway that allows electrons to flow. Electrons flow.
Basic study of a switch Unit 3.Lesson 3. A switch Purpose A switch is a mechanical device used to connect and disconnect a circuit at will Parts seen.
Single pole Double throw (SPDT) Switch By: Engr.Irshad Rahim Memon.
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
Circuits and components Unit 45 Dr. Hatem Elaydi Engineering Technical English Islamic University of Gaza April 6, 2016.
Electricity. TYPES OF CIRCUITS Individual electrical circuits normally combine one or more resistance or load devices. The design of the automotive electrical.
AIR CONDITIONING (COOLING)
Fluid Power Control.
Design of starters for AC motors C.K. PITHAWALA COLLAGE OF ENGINEERING & TECHNOLOGY Group no - 3 Name Enrolment no Chaudhari Darshan M Chaudhari.
Push Button Station and Relay
Industrial Star Delta Starter For a 3-Phase Induction Motor
Real-time Software Design
Circuits.
Circuits and components Chapter 45
Blower-/Fan Coil-Actuator
PLC Timers MECH 1500 Two classes of timers: Retentive Non-Retentive.
PRESENTED BY:AMOD SHAKYA. Power Circuit –connectoin with motor using contactor Control Circuit-using switch make a holding circuit.
GROUND-FAULT GROUND-CHECK MONITOR
Industrial Electronics
MECH 1500 Motor Controls.
Equipotential Grounding Procedures Protective Grounding Training
Current Electricity and Electric Circuits
PSS0 Design & Concept of Operations
Programmable Logic Controllers (PLCs)
Electrical components and systems
PLTW Terms PLTW Vocabulary Set #12.
Fluid Power System Electrical Control
Presentation transcript:

SISTEMA Example Three

Example 3: Position monitoring of a moveable guard – Category 3 – PL d Circuit Diagram

Example 3: Position monitoring of a moveable guard – Category 3 – PL d Safety Function Safety-related stop function, initiated by a protective device: opening of the moveable guard (protective grating) initiates the safety function STO (safe torque off). Functional Description Opening of the moveable guard (e.g. safety guard) is detected by two position switches B1 and B2 in a break contact/make contact combination. The position switch B1 with direct opening contact actuates a contactor Q2 which interrupts/prevents hazardous movements or states when it drops out. The position switch B2 with make contact is read in by a standard PLC K1, which can bring about the same de-energization response by actuation of a second contactor Q1. The safety function is retained in the event of a component failure.

Example 3: Position monitoring of a moveable guard – Category 3 – PL d Functional Description Cont. The switching position of B1 is also read into the PLC K1 by means of a make contact, and is compared for plausibility with the switching position of B2. The switching positions of the contactors Q1 and Q2 are likewise monitored in K1 by mechanically linked read back contacts. Component failures in B1, B2, Q1 and Q2 are detected by K1 and lead to operating inhibition owing to the dropping out of Q1 and Q2. Faults in the PLC K1 are detected only by the function (fault detection by the process).

Example 3: Position monitoring of a moveable guard – Category 3 – PL d Design Features Basic and well-tried safety principles are observed and the requirements of Category B are met. Protective circuits (e.g. contact protection) as described in the initial paragraphs of Chapter 8 are implemented. A stable arrangement of the protective device is assured for actuation of the position switch. B1 is a position switch with direct opening contact in accordance with IEC 60947-5-1, Annex K. The supply conductors to the position switches are laid separately or with protection. Faults in the start-up and actuation mechanism are detected by the use of two position switches differing in the principle of their actuation (break and make contacts)..

Example 3: Position monitoring of a moveable guard – Category 3 – PL d Design Features Cont. Q1 and Q2 possess mechanically linked contact elements to IEC 60947-5- 1, Annex L. The PLC K1 satisfies the normative requirements described in Section 6.3