Our microscopes Olympus IX81 (wide-field fluorescence, transmission modes, TIRF) Olympus BF51 (color images, less demanding fluorescence applications)

Slides:



Advertisements
Similar presentations
Microscopy Do you want a footer?.
Advertisements

 Identify the parts of a compound light microscope and explain their functions  Define magnification  Calculate the total magnification of the lenses.
Microscopes Compound Light (up to X 2,000) Electron (up to X 200,000) Scanning Electron Microscope (SEM) Transmission Electron Microscope (TEM)
Blizard Advanced Light Microscopy club Making friends with your microscope.
July 2008 Jonathan Sommer.  Has two modes to view samples Optical mode (white light) and Fluorescence mode  Depending on your sample either mode maybe.
Fluorophores bound to the specimen surface and those in the surrounding medium exist in an equilibrium state. When these molecules are excited and detected.
Image-Pro Premier Basic Training Course
Fluorescence microscopy – Principle and practical consideration Hiro Ohkura.
Live Imaging and Other Capabilities of the Bioscience Imaging Facility (BIF)
Introduction to the oil immersion compound microscope
USE AND CARE OF THE MICROSCOPE LECTURE 1. MICROSCOPY u Light Microscopy: any microscope that uses visible light to observe specimens u Compound Light.
Uses of the CCD n Image fluorescence - living or fixed, multiple colors n Image phase or DIC - living or fixed.
Instrument Performance --Tests Field illumination (plastic slides, beads) Axial resolution (mirror) Chromatic aberration (1 u beads, mirror) Laser power.
Microscopes are used to increase the magnification and resolving power of the unaided eye MICROSCOPES.
1.1 Intro to the microscope and Calculating cell size.
Microscopy. Introduction of Microscopes  Microscopic – invisible to naked eye  1595  Magnified images approximately 3x – 10x.
What’s magnified?. Microscopy Microscopes “micro” means small! “scope” means watch/look! Microscopes were first developed as entertainment for the.
Microscopy.
Optical Microscopy Widefield Microscopy - Brightfield, Darkfield, DIC, Phase Contrast, Fluorescence … Total Internal Reflection (TIR and TIRF) Microscopy.
TIRF Total Internal Reflection Fluorescence Microscopy specialized fluorescence microscopy technique specifically images a very thin optical section (50-250nm)
Using the Microscope Lab 1 Biology 101.
Microscopy 1. UNITS OF MEASUREMENT 1 m = 1000 mm (millimeters) 1 m = 1000 mm (millimeters) 1000 mm = 1 µm (microns) 1000 mm = 1 µm (microns) Bacteria.
MICROSCOPY Tutorial 1. Types of Microscopy Light Fluorescence Confocal Electron –Transmission Electron Microscopy (TEM) –Scanning Electron Microscopy.
Nanonics MultiView 2000™ Product Presentation. MultiView 2000 ™ Complete System MultiView 2000™ Product Presentation.
Tile Scanning on Zeiss Microscopes Kim Peifley 2/09/15.
Advanced Biology Visualizing Cells. The Human Eye  Resolution – The minimum distance two points can be apart and still be distinguished as two separate.
THE COMPOUND LIGHT MICROSCOPE. USING THE COMPOUND LIGHT MICROSCOPE WET MOUNT REVIEW MOVING THE SLIDE LETTER INVERSION DEPTH OF FIELD MAGNIFICATION EYEPIECE.
Microscopes Compound Bright-Field Light Microscope
Biology Chapter 1 Biology as a science. Scientific Method.
Microscopy.
Tools of the Biologist The Incredible World of Microscopes video
MultiView 1000™ Product Presentation Nanonics MultiView 1000™
Microscope 101 Always carry a scope with two hands: One on the arm and one under the base.
Designing a Microscopy Experiment Kurt Thorn, PhD Director, Image from Susanne Rafelski, Marshall lab.
Bruno De Fanti Anel EE230 University of California, Santa Cruz December 2011 LASER SCANNING CONFOCAL MICROENDOSCOPY.
Confocal Microscopy Kurt Thorn NIC.
Date of download: 5/30/2016 Copyright © 2016 SPIE. All rights reserved. Optical configuration. The function of a BFP imaging lens, added externally to.
Microscopy Techniques and Calculations. Types of Microscopes.
Microscopes Moisey (2009), Optical Microscope [photograph]. Retrieved from
Scanning Transmission Electron Microscope
Date of download: 6/22/2016 Copyright © 2016 SPIE. All rights reserved. Index-matching effect. Matching the index of refraction of the bead with the solution.
Parts and Functions of a Compound Microscope
Date of download: 6/22/2016 Copyright © 2016 SPIE. All rights reserved. Prismless confocal total internal reflection (CTIR) microscope. 532-nm light is.
Date of download: 7/5/2016 Copyright © 2016 SPIE. All rights reserved. Spatial light modulator-two-photon microscope (SLM-2PM) scheme: (1) Ti:Sa laser.
Outline History(TEM) Background Components Specimen Preparation Imaging method Contrast formation Modifications STEM References.
Tools.
Light Microscope Terms and Practices.
Chapter 2: Viewing the Microbial World
Microscopy.
MultiView 400™ Product Presentation Nanonics MultiView 400™
YZ XZ XY Fig. Supp 1: PSF for BioRad MRC-1024 laser-scanning confocal microscope with 60x oil immersion lens (NA 1.4). The PSF was sampled with a resolution.
Supported by NIH Grant EB
Introduction to MICROSCOPES & BIOLOGICAL DRAWINGS
Microscope Calculations
Measuring the length of cells
New Turf for CFP/YFP FRET Imaging of Membrane Signaling Molecules
Use and Care of a Compound Light Microscope
LIGHT MICROSCOPY basic
Complex Nanophotonics
Microscopes.
New Turf for CFP/YFP FRET Imaging of Membrane Signaling Molecules
Laboratory Exercise 2 “Microscopy”.
Microscopy.
Scanning Electron Microscopy (SEM)
Actin Dynamics at the Living Cell Submembrane Imaged by Total Internal Reflection Fluorescence Photobleaching  Susan E. Sund, Daniel Axelrod  Biophysical.
Harvard Medical School Neurobiology Imaging Facility
Microscopy.
Harvard Medical School Neurobiology Imaging Facility
Dip-coating of S. platensis, C. reinhardtii, and T. subcordiformis.
NA determines resolution.
Presentation transcript:

Our microscopes Olympus IX81 (wide-field fluorescence, transmission modes, TIRF) Olympus BF51 (color images, less demanding fluorescence applications) Olympus FV1000 (high quality for many common needs; 405, 458, 488, 515, 543, 635 nm) Olympus FV3000 (fast acquisition, sensitive detectors for weak signals, large amounts of data, unusual fluorophores, image post-processing; 405, 488, 561, 594, 640 nm)

Confocal or wide-field? Use confocal for: thick samples precise localization of a fluorophore strong autofluorescence Use wide-field for: initial sample check small or flat cells some quantitative applications (ask MM) through plastic

Similar quality for most typical samples FV1000 or FV3000? Similar quality for most typical samples

Understanding objectives Oil High resolution (NA 1.42) No oil Intermediate resolution (NA 0.75)

Oil on objectives Wipe oil after use (2-3 swipes with lens tissue) This is what happens after oil has been left on the objective for a few days

Coverslips #1.5 (0.17 mm) are the best! This is especially important for dry objectives Coverslips must be clean and dry (no mounting medium on the top surface!)

Sign-up Only trained students are allowed to use any microscope Login on confocal microscopes is enabled only for trained users All except FV3000: Sign up in room A202 FV3000: make reservation on scheduling.science.kent.edu limit to 4 hours per user per day can use more time if available within 24 hours notify the next user if finished earlier than planned