Effects of an automated endotracheal-tube-compensation system on a pressure-support breath. Effects of an automated endotracheal-tube-compensation system.

Slides:



Advertisements
Similar presentations
The changes in peak flow and inspiratory time between a minimum rise time (first 2 breaths) and a maximum rise time (last 2 breaths), with the Servo-i.
Advertisements

Airway pressure and flow waveforms during constant flow volume control ventilation, illustrating the effect of an end-inspiratory breath-hold. Airway pressure.
Trigger pressure-time product (PTP) with zero pressure support, with no leak, medium leak, and large leak. Trigger pressure-time product (PTP) with zero.
Lung CT images were obtained while tracing the curve in static conditions. Lung CT images were obtained while tracing the curve in static conditions. Note.
Lung simulator diagram of airway pressure release ventilation (APRV): volume (yellow), lung pressure (white), and flow (orange)/time curve. Lung simulator.
The Arndt endobronchial blocker, one of the commercially available endobronchial blockers for lung isolation. The Arndt endobronchial blocker, one of the.
Picture of bubble PEP devices.
Cuff-pressure changes after the addition of 5 mL and 10 mL of air into the cuff of 3 artificial airways, after initial baseline of 30 cm H2O established.
Noninvasive ventilation-neurally adjusted ventilatory assist (NIV-NAVA) where each patient effort is captured but support is insufficient (maximum electrical.
A: Pressure (green) and volume (black)/time curve in airway pressure release ventilation (APRV). A: Pressure (green) and volume (black)/time curve in airway.
An example of delayed cycling during pressure-support ventilation of a patient with COPD, on a Puritan Bennett 7200 ventilator, which has a flow-termination.
Asynchrony index at baseline and following optimization of pressure support (PS) level (A), and following optimization of mechanical inspiratory time (mechanical.
Likert-scale agreement ratings regarding the use of extubation readiness parameters by pediatric critical care physicians. Likert-scale agreement ratings.
Representative example of the use of a fiberoptic bronchoscope (FOB) to guide intubation through a supraglottic airway device. Representative example of.
Example airway pressure and rib-cage impedance in a premature infant supported with the biphasic mode of SiPAP (“sigh” positive airway pressure) from the.
Simulated screenshot of flow starvation in volume control continuous mandatory ventilation. Simulated screenshot of flow starvation in volume control continuous.
Characteristics of a pressure-supported breath.
The peak flows (60 L/min) and flow patterns are the same for all the breaths. The peak flows (60 L/min) and flow patterns are the same for all the breaths.
Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value, Area Under the Curve, and 95% CIs for the 0, 10, 25, 50, and 100 SatSeconds.
Comparison of airway pressure release ventilation (APRV) (blue curve) and biphasic positive airway pressure (BIPAP) (black curve). Comparison of airway.
Example of invasive measurement of respiratory pressures.
A: Machine-triggered intermittent mandatory ventilation (IMV) with inadequate patient triggering of mandatory breaths. A: Machine-triggered intermittent.
Illustrated here are several features used to determine that the esophageal balloon is correctly placed in the esophagus. Illustrated here are several.
Typical pressure-time curves during forced expiration against an occluded airway in cystic fibrosis (CF) patients and healthy controls. Typical pressure-time.
Top: Stress index (SI) in a patient early in the course of ARDS
Pressure, flow, volume, and electrical activity of the diaphragm (EAdi) waveforms from a patient on pressure support ventilation, and the presumed pressure.
Pressure, flow, volume, and electrical activity of the diaphragm (EAdi) waveforms from a patient on pressure support ventilation, and the presumed pressure.
This tracing depicts 30 seconds of information.
Graphic representation of a dynamic airway pressure scalar during volume control ventilation with a constant inspiratory flow. Graphic representation of.
Schematic drawing of alveolar sizes at upper (A), middle (B), and lower dependent (C) lung regions at end expiration and end inspiration. Schematic drawing.
Effect of respiratory mechanics on cycling of pressure support from inhalation to exhalation. Effect of respiratory mechanics on cycling of pressure support.
The use of a real time analyzer during a single brief inhalation-exhalation of methane (CH4), acetylene (C2H2), and carbon monoxide (CO). The use of a.
Bland-Altman plots with exhaled VT difference plotted against the mean (displayed and pneumotachograph-measured) with and without sensor for method circuit.
Flow, esophageal pressure, airway pressure, and transpulmonary pressure can be used to calculate respiratory system compliance, chest-wall compliance,
Control circuit for an adaptive pressure targeting scheme (eg, Pressure Regulated Volume Control). Control circuit for an adaptive pressure targeting scheme.
The curved Macintosh blade and straight Miller blade in standard adult sizes (Macintosh size 3, Miller size 2), with different handle choices available.
Change in mean pulmonary arterial pressure after a 5-min inhalation of the Rho kinase inhibitor Y in rats with hypoxic pulmonary hypertension, with.
Gap size differences between the fiberoptic bronchoscope and a standard endotracheal tube (ETT) are shown. Gap size differences between the fiberoptic.
The Boussignac continuous positive airway pressure (CPAP) is a small plastic cylinder that attaches to a face mask. The Boussignac continuous positive.
Control circuit for set-point or dual targeting schemes.
The concept of using pulmonary function tests to place subjects into physiologic “buckets” using the interpretation algorithm of the American Thoracic.
Study protocol. Study protocol. Subjects with hemodynamic, respiratory, and neurologic stability and positive predictive index were randomized to 3 groups.
Assembly used to convert a standard ventilator to an intermittent mandatory ventilation circuit. Assembly used to convert a standard ventilator to an intermittent.
Blind intubation through a supraglottic airway device (SAD), in this case, the laryngeal mask airway (LMA) Fastrach. Blind intubation through a supraglottic.
Breathing frequency and PaCO2: comparison between high-flow nasal cannula oxygen therapy (HFNC) and comparative therapies in 8 studies. Breathing frequency.
Control circuit for a servo targeting scheme (eg, Proportional Assist Ventilation). Control circuit for a servo targeting scheme (eg, Proportional Assist.
Negative pressures generated in our airway model.
A: Pressure ulcer on the left cheek of a patient after 1 week of prone positioning using a commercially available endotracheal tube (ETT) holder. A: Pressure.
Graphical representation of the locations where spontaneous breaths may occur during the airway pressure (Paw) release ventilation ventilatory cycle. Graphical.
Calculated negative pressure developed in the lung plotted against the outside diameter of the suction catheter to the inside diameter of the airway. Calculated.
Flow, airway pressure, and transversus abdominis electromyogram (EMG) waveforms from a mechanically ventilated patient with COPD receiving pressure-support.
Plots of alveolar PO2, hemoglobin saturation, and alveolar PCO2 as a function of alveolar ventilation in a normal subject at sea level (inspired oxygen.
Components of a patient-triggered mechanical breath.
FEV1 and FVC for the control group (without noninvasive ventilation [NIV]), NIV with an inspiratory pressure (IPAP) of 15 cm H2O and expiratory pressure.
Determinants of patient-ventilator interaction.
Relationship of mouth pressure (Pmo) and box pressure (Pbox) by body plethysmography under closed–loop panting conditions (left) and open-loop panting.
Airway pressure and flow graphics illustrate delayed cycling.
The CoPilot. The CoPilot. Like the GlideScope, this video laryngoscope has an angulated blade to facilitate clear image capture of the glottic opening.
A: Work of breathing before and after nebulized terbutaline delivered via standard nebulization method versus delivered during continuous positive airway.
The changes in peak flow and inspiratory time between a minimum rise time (first 2 breaths) and a maximum rise time (last 2 breaths), with the Servo-i.
Relationship between airway resistance (Raw) and lung volume, the reciprocal of Raw (conductance of the airways [Gaw]) and lung volume, and Gaw/TGV (thoracic.
Double lumen endotracheal tube (DLET) with its upper channel dedicated to fiberoptic bronchoscopy (FOB) and lower channel exclusively dedicated to ventilation.
Experimental setup. Experimental setup. Each tested ventilator was connected to the TTL test lung via a ventilator circuit. An oxygen analyzer, a pressure.
Progression of spontaneous breathing trials administered during inspiratory muscle strength training study interventions. Progression of spontaneous breathing.
With the patient's mouth opened, the tip of the curved blade (Macintosh) is inserted into the right side of the mouth. With the patient's mouth opened,
Enhancing flow synchrony with a variable flow, pressure-targeted breath. Enhancing flow synchrony with a variable flow, pressure-targeted breath. In the.
Average drug doses in the peripheral lung, central lung, and extrathoracic airway; residual drug left in the device; and residual drug that was exhaled.
Basic setup for high-flow nasal cannula oxygen delivery.
Fentenyl and lorazepam use for the first 5 d of ventilatory support are presented. Fentenyl and lorazepam use for the first 5 d of ventilatory support.
Representative waveforms for each of the devices tested from which the oscillatory f was counted. Representative waveforms for each of the devices tested.
Presentation transcript:

Effects of an automated endotracheal-tube-compensation system on a pressure-support breath. Effects of an automated endotracheal-tube-compensation system on a pressure-support breath. Column A shows a typical pressure-support breath. Note that the airway (circuit) pressure curve has the desired square wave shape, but this is distorted by the endotracheal-tube resistance to a more gradually rising pressure profile in the trachea. In contrast, with an automated endotracheal-tube-compensation system (pressure support plus automatic tube compensation, column B), the airway (circuit) pressure is automatically adjusted to create the desired square wave of pressure in the trachea. Neil R MacIntyre Respir Care 2011;56:73-84 (c) 2012 by Daedalus Enterprises, Inc.