QA September 2001 Fire Topic

Slides:



Advertisements
Similar presentations
$200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 Tip SizesNozzlesPotpourriFormulas.
Advertisements

HH HOUSTON FIRE DEPARTMENT PUMP OPERATOR PROGRAM
Fire Apparatus Pump Theory
Chapter 14 Lesson Goal After completing this lesson, the student shall be able to effectively operate a solid stream nozzle, fog stream nozzle, and broken.
Master Streams. Master Stream Training Available...  Awareness and Operations Training  Portable Monitors  Offensive Strategies  Defensive Strategies.
Chapter 14 Lesson Goal After completing this lesson, the student shall be able to effectively operate a solid stream nozzle, fog stream nozzle, and broken.
Blitzfire Deck Gun Ground Monitor
FIREFIGHTING NOZZLES and FIRE HYDRAULICS

Nozzles and Fire Streams
Nozzles, Fire Streams, and Foam
Fire Streams Geronimo Vol. Fire Dept.. Extinguishing Properties of Water G Water extinguishes fires by G Cooling G Remove heat from the fire G Smothering.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Hydraulic Calculations
For The Driver Operator
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
5/4/2015Dixon High School Fire Department1 Introduction The Recruit will also practice and masters certain skills and will be tested on these skills. At.
Nozzles and Fire Streams 1. Introduction Fires usually extinguished by water Water delivered using nozzles and fire streams Nozzle selection important.
Service Delivery 3 Hydraulics. Aim To ensure students can explain the principles of obtaining and delivering water.
Water Supply Advantage of water as extinguishing agent w Water Abundance w Excellent heat absorption qualities w Easily moved long distances w Easily stored.
Pumping Apparatus Driver/Operator
Fire Streams SFFMA Training Objectives: –
Fire Suppression Techniques IFSTA Chapter 14
Nozzles, Fire Streams, and Foam
Firefighter I. Copyright © Texas Education Agency All rights reserved. Images and other multimedia content used with permission. 2 Copyright and.
HYDRAULICS.
Pumping Apparatus Driver/Operator
Characteristics of Water
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Principles of Liquid Flow through Pipelines
Fire Safety & Fire Extinguisher Use. OBJECTIVES Understand the combustion process and different fire classes Understand fire extinguisher types, operating.
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
Module B Nozzles and Fire Streams
Basic Hydraulics Irrigation.
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Water Supply.
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Instructor Lee Lautzenheiser
Pumping Apparatus Driver/Operator
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
NFPA 31 Standard for the installation of Oil- Burning Equipment
Pumping Apparatus Driver/Operator
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
CXS490 Carbon Dioxide Systems
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
FIRE BEHAVIOR ILLINOIS OSFM FIREFIGHTER III. TERMS Heat Measurement –BTU Amount of heat required to raise the temperature of 1 pound of water 1 degree.
1 CXS490 - Characteristic of Fire. 2 Other Resources NFPA Standards (available through Seneca Libraries Link NFPA Handbook Manufacturer’s Technical Information.
Mahoney, Hannig, Fire Department Hydraulics, 2nd Ed. ©2009 by Pearson Education, Inc., Upper Saddle River, NJ Fire Department Hydraulics Chapter 8 Required.
To be effective an extinguisher: Must be readily accessible In working order Suitable for the hazard Large enough to control the size fire Must be readily.

FIRE CONTROL State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
Fluids. Introduction The 3 most common states of matter are: –Solid: fixed shape and size (fixed volume) –Liquid: takes the shape of the container and.
Firefighter III Module B Water Supply (4-19) (4-19)
Learning Objective 1 Explain the way vaporization and steam relate to the extinguishing properties of water.
FIRE EXTINGUISHER D TRAINING. Objectives Understand the combustion process and different fire classes. Understand the combustion process and different.
Flammable Liquids Directorate of Training and Education
Compressed Air Foam System
2013Q2.
Foam Equipment & Systems Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Fire Hose Nozzles & Flow Rates
Fire Extinguishment Theory FIREFIGHTER I 1. 2 Copyright and Terms of Service Copyright © Texas Education Agency, These materials are copyrighted.
Fire Suppression (Fire Fighter II)
Fire Attack and Foam (Fire Fighter II)
Master Stream Operations
Fire Attack and Foam (Fire Fighter I)
Essentials of Fire Fighting
Fire/Life Safety Means of Egress Fire Protection Hazardous Materials.
Portable Fire Extinguisher Overview
Presentation transcript:

QA September 2001 Fire Topic Fire Stream Practices

Fire Extinguishment Theory Temperature Reduction: usually by applying water Fuel Removal: stop fuel from being added remove fuel from path of fire Oxygen Exclusion or Dilution introduce inert gas: carbon dioxide, nitrogen separate or smother: steam, foam Inhibiting Chemical Reaction Dry chemicals, halons, etc. interrupt flame production. most effective on liquid and gas fuels

Compatibility Determine the extinguishing method or extinguishing agent compatible with the material involved.

Characteristics of Water Molecule of two parts hydrogen and one part oxygen Solid (ice) @< 32 degrees (freezing point) Liquid (water) @ 32 to 212 degrees (boiling point) Gas (water vapor or steam) @ > 212 degrees Practically incompressible Weight: approximately 62.5 lb/ft3 Absorbs large amounts of heat by 2 laws of physics: Law of specific heat: heat-absorbing capacity of a substance (water is given a value of 1.00) Latent Heat of Vaporization: heat absorbed during vaporization

Advantages of Water as Agent Great heat absorption capacity Readily available Inexpensive 1,700:1 vaporization expansion ratio

Disadvantages of Water High surface tension Reactivity with certain materials Can freeze Low viscosity Electrically conductive Heavy

6 Principles of Pressure Fluid pressure is perpendicular to any surface. Fluid pressure at a point in a fluid at rest is the same intensity in all directions. Pressure applied to a confined liquid from without is transmitted equally in all directions. The pressure of a liquid in an open vessel is proportional to its depth.

6 Principles of Pressure (cont.) The pressure of a liquid in an open vessel is relative to its density The shape of a vessel is irrelevant to the pressure of the liquid.

Types of Pressure Atmospheric: the pressure applied to the surface by the Earth’s atmosphere (14.7 psi @ sea level) Head: height of a water supply above discharge Static: pressure in a water system before water flows from a hydrant Normal Operating: pressure in water distribution system during normal consumption demands Residual: pressure remaining after overcoming gravity and friction loss when forcing water through pipe, fittings, fire hose, and appliances

Types of Pressure (cont) Flow / Velocity: forward force pressure at a discharge opening while flowing water Elevation Loss and Gain: nozzle above pump = pressure loss nozzle below pump = pressure gain 0.434 psi per foot

Principles of Friction Loss Friction Loss: portion of total pressure lost while forcing water through pipe, fittings, fire hose, etc. varies with length of hose varies with velocity (if flow doubles, FL quadruples) varies with hose diameter FL same, regardless of pressure Critical Velocity: turbulent agitation created when velocity limits are exceeded Water Hammer: damaging energy surge created when water is suddenly stopped

Fire Stream: a stream of water or water-based extinguishing agent from the time it leaves the nozzle until it reaches the desired point. The condition and effectiveness of the stream is influenced by: design, adjustment, and condition of the nozzle operating pressure velocity gravity wind friction with the air

Fire Stream Production 4 basic elements: Water Supply Static Supply: lakes, rivers, swimming pools, portable tanks, etc. (Where are the drafting locations in your run districts?) Apparatus Water Tanks (What is the capacity of your booster tank?) Pressurized Distribution System (Do you know the hydrant capacity color-coding system?)

Fire Stream Production 4 basic elements: (cont.) Fire Department Pumper: receives water supply and increases pressure to required level for an effective production of fire streams (What is the rated capacity of your engine?)

Fire Stream Production 4 basic elements: (cont.) Fire Equipment Hose (What sizes and lengths are on your engine?) Nozzles: forms and shapes the stream Appliances: wyes, siameses, manifolds, double couplings, water thieves, etc. Hardware: spanner wrenches, hose straps, hose bridges, etc.

Fire Stream Production 4 basic elements: (cont.) Trained Personnel: The best supply, apparatus, and equipment will not produce effective fire streams without well trained personnel.

Sizes & Types of Fire Streams Fire Streams are identified by size and type. Size: stream volume in gallons per minute (GPM) Handline: 40 GPM to 350 GPM Master Stream: >350 GPM Type: stream shape or pattern Solid: Produced by a smoothbore, fixed-orifice nozzle (long range/ high volume). The stream must maintain continuity, must shoot 9/10ths through a 15” circle and 3/4ths through a 10” circle, must attain height in moderate wind.

Types of Fire Streams (cont.) Solid (cont.): The flow rate and the reach depend upon the velocity (discharge pressure) and the diameter of the nozzle orifice. At equal pressure, doubling the nozzle size will quadruple the GPM. The maximum horizontal reach is achieved at 32 degrees. The optimum vertical reach is at 70 to 75 degrees. Fog Stream: varied pattern stream, composed of water droplets/ from wide (45-80 degrees), to narrow (15-45 degrees), to straight.

Types of Fire Streams (cont.) Broken Streams produced by special stream nozzles (water curtains, rotary distributor, spoon billed, etc.) or by directing two solid streams together do not have a specific pattern composed of large drops usually not adjustable for fires in attics, basements, partitions, etc. increased water damage should be expected

Types of Nozzles Solid Stream Nozzles Fog Stream Nozzles Handline Nozzles Master Stream Nozzles Special Purpose Nozzles

Foam Fire Streams Foam concentrate is added to a water fire stream using a proportioning device, which creates a foam solution Air is added to the solution, which creates the finished foam Effective on flammable liquids, hazardous materials spills, confined space fires, bulk class A fires

Foam Fire Stream Production 1. Choose appropriate foam concentrate 2. Use hydraulically compatible eductor and nozzle 3. Set eductor to proper concentration percentage 4. Attach eductor, attack hose, and nozzle to pump 5. Assemble sufficient foam concentrate at eductor 6. Place eductor suction hose in concentrate 7. Increase water pressure to eductor specifications 8. Apply finished foam

PP = NP + FL + EL PP: Pump Pressure NP: Nozzle Pressure know the manufacturer’s specifications FL: Friction Loss determined by field tests or by calculations includes hose and appliances EL: Elevation Loss approximately 0.5 psi/ft (vertically)

C = Coefficient specific to hose construction 2 FL = CQ L + A C = Coefficient specific to hose construction Q = Quantity of water in hundreds of gpm L = Length of hose in hundreds of feet A = Appliances: siameses, wyes, master stream devices, etc.

Strategic Objectives ( in order of importance) Rescue: direct streams to protect victims and rescuers Exposure Protection: nearby combustibles Interior: areas of the fire building not involved Exterior: adjacent buildings Confinement: coordinate streams and ventilation to attack and contain the fire Extinguish: apply sufficient streams to seat of fire to reduce heat and heat production

Types of Attack Offensive: direct interior attack greatest risk to firefighters IC must weigh fire and building conditions, life hazards, and building construction type must be coordinated with ventilation efforts attack crews must understand the principles of fire spread streams must be of adequate size and appropriate type to achieve the tactical objectives

Types of Attack (cont.) Defensive: goal is to contain fire to building involved (“written off”) used when available fire flow is insufficient or, structure is obviously lost, regardless of flow, or repeated interior attacks have failed, or structural stability is compromised, or interior crews’ safety is questionable Direct streams to protect last-minute rescue and interior attack crews’ egress

Types of Attack (cont.) Defensive (cont.): concentrate on protecting exposures remove apparatus, crews, appliances, and hose lines from collapse zone attack fire from outside with monitors and elevated master streams