Nuclear Medicine Department Loyola University Medical Center

Slides:



Advertisements
Similar presentations
5.4.2 Diagnosis methods in medicine
Advertisements

Instruments & Radiopharmaceutical Production
Lesson 16 Nuclear Medicine. What is Nuclear Medicine? Diagnosis and Treatment of Disease using small amounts of radio-nuclides (radiopharmaceuticals)
CT & MRI – What is Expected from the Radiological Technologists Dr. Harsha Dissanayake MBBS, M.Phil, MD(Radiology) Dip. Neurovascular Diseases (France)
Gamma Camera Quality Control
Isotopes. APPLICATIONS of nuclear processes Military Power Radiation Many important economic and social benefits are derived from the use of isotopes.
HOW TO SURVIVE AN INSPECTION Stephen M. Karesh, Ph.D. Nuclear Medicine Department Loyola University Medical Center Maywood, IL.
King Abdul-Aziz University Diagnostic Radiology Department MS.Nouf Al-Zahrani DR. Saddiq Jastniah Introduction to Nuclear Medicine 2 nd year.
Equilibrium and Generators
VENUS MEDICAL INTRANET. VENUS MEDICAL INTRANET is a RIS (NMIS) solution optimized to support nuclear medicine. VENUS MEDICAL INTRANET based on the newest.
1 NRC Medical Rulemaking Workshops Michael Fuller, US NRC.
Establishment of a Training Dosimetry Laboratory in Cairo University Dr. Hassan Fathy for NSPA.
Radionuclide generators for Nuclear Medicine
Introduction to Technology  Measure of “hot particle” dose  3 layer analysis.
Radionuclide Generators
Radionuclide Production
Radionuclide Generators
Technetium-99m generator
RADIATION SAFETY Phil Facey Lead Superintendent Radiographer
The Bone Scan By Lance Lewis An Illustration of a Bone Scan Taking Place.
X –Ray Technician. Nature of Work Precisely follow orders from physicians Adjust and maintain imaging equipment Prepare patients for procedures Operate.
Introduction to Nuclear Medicine
Nuclear Medicine. The History Henri Becquerel 1896-Discovered mysterious “rays” Nobel Prize Marie Curie named mysterious rays “radioactivity”
Radiology & Nuclear Medicine Referrals - some legal requirements & duties - Mr John Saunderson, Consultant Physicist / Radiation Protection Adviser, Radiation.
Medical Uses-Diagnostics By: Carly Baurer. Background Info and History The German physicist Wilhelm Rontgen, discovered the radiation known today as X-rays.
Reorganizing the Knowledge in Government Documents for Quick Response of Emergencies Dr. Lili RONG Associate Professor Institute of Systems Engineering.
Hot Lab 11. dose calibrator, an ionization chamber used in nuclear medicine to measure the amount of radioactivity of a radionuclide before injection.
BY Nisvil Smith.  Nuclear medicine is a branch of medical imaging that uses small amounts of radioactive material to diagnose and determine the severity.
Gallium-68 – a candidate for use in clinical routine
DIAGNOSTIC SERVICES What They Do * Perform tests or evaluations that aid in the detection, diagnosis, and treatment of disease, injury or other physical.
DOE SUPPORT OF NUCLEAR MEDICINE RESEARCH Alan B. Packard, Ph.D. Vice President Radiopharmaceutical Sciences Council Society of Nuclear Medicine.
 Radiopharmaceuticals are agents used to diagnose certain medical problems or treat certain diseases. They may be given to the patient in several different.
Radiopharmaceutical Production Sub STOP. Radionuclidic purity Radionuclidic purity may be defined as the fraction of total radioactivity that is present.
Radiopharmaceuticals and Kit preparation
Digital Radiology Techniques used in imaging. Why is technology so important? Prenatal Diagnosis and Management of Conjoined Fetuses.
Application of Calibrated Instruments in Medical Facilities MAJ H. Mike Stewart, Jr., MS, CHP April 17, 2009.
Radionuclides production cont. Generators. ● Where clinical tests require that a radioisotope be administered internally, it is advantageous to use an.
Nuclear medicine Basic principles.
Nuclear Medicine Technique I 355 RAD L.Aya Ahmed Saeed.
Introduction to nuclear medicine NMT 231 L.Aya Ahmed Saeed.
MEDICAL USES FOR RADIATION Andres Perez P.1 Level 4 MT10.
L ABORATORY Q UALITY C ONTROL. INTRODUCTION _A major role of the clinical laboratory is the measurement of substances in body fluids or tissues for the.
Technetium-99m By Emily Vella Science Assessment Task 3.
Notification to Authorities: Notification to Authorities: RADIOACTIVE MATERIAL PROCEDURE RADIOACTIVE MATERIAL PROCEDURE [Insert Institution Name Only]
Quality assurance for diagnostic imaging equipment.
Medical Imaging. X-ray Radiography 2-D projection image created from difference in x-ray absorption rates between tissues 2-D projection image created.
7-A Block R III, Johar Town, Lahore, Pakistan SHAUKAT KHANUM MEMORIAL CANCER HOSPITAL & RESEARCH CENTRE References Conclusion.
Case of the Day The likely cause of the poor image quality is: A. Incorrect collimators used B. Energy window incorrectly set over scatter below the 140.
Accuracy, sensitivity and specificity analysis
PACS as Medical Devices
Medical Imaging.
PHYSICS ……is about how the physical world works – anything from solar radiation to nuclear bombs.
Radionuclide Generators
Quantitative Nuclear Medicine Imaging
Nuclear Medicine Physics
Lecture 10 Technological Principles of Medical Instrumentation
IAEA CN-255 Paper233 PEDIATRIC RADIATION PROTECTION THROUGH 99mTc -DMSA ADMINISTRED ACTIVITY STUDY AT NUCLEAR MEDICINE DEPARTMENT, CONSTANTINE, ALGERIA.
This abdominal Tc-99m pertechnetate scintigraphy was performed 15 minutes after the radionuclide injection. The spherical area of increased uptake (arrow)
Diagnostic Services in Healthcare
Radionuclides production cont.
Pathology Digital Radiology
Medical Imaging Imagining Modalities.
Lecture 4(Unit II): Gas-Filled Detector Quality Control
CLRS 321 Nuclear Medicine Physics & Instrumentation I
Accuracy, sensitivity and specificity analysis
Nofetumomab Merpentan (Fragment)
Given that, {image} {image} Evaluate the limit: {image} Choose the correct answer from the following: {image}
Postherpetic Pseudohernia
Comprehensive Medical Assisting, 3rd Ed Unit Three: Managing the Finances in the Practice Chapter 15 – Outpatient Procedural Coding.
Nuclear medicine.
Presentation transcript:

Nuclear Medicine Department Loyola University Medical Center QUALITY CONTROL IN THE HOT LAB Stephen M. Karesh, Ph.D. Nuclear Medicine Department Loyola University Medical Center Maywood, IL 60153

RATIONALE FOR PERFORMING QUALITY CONTROL For certain procedures, IT'S THE LAW. Non-Diagnostic Study ==> Procedure must be repeated; increased radiation dose and patient discomfort; delayed diagnosis

"Would I inject this into my mother?" CRITERION You must be able to answer "yes" to the question, "Would I inject this into my mother?"

CLASSIFICATION OF IMPURITIES TYPE EXAMPLE EFFECT Radionuclidic Mo-99 Radiation Dose Poor Image Quality Radiochemical HR Tc Poor Image Quality Altered Radiation Dose Chemical Al3+ Poor Image Quality

DETECTION OF IMPURITIES TYPE OF IMPURITY METHOD Radionuclidic Dose Calibrator or Multichannel Analyzer Radiochemical Thin Layer Chromatography Chemical Colorimetric

Required QC Testing of a Mo/Tc Generator TEST FREQUENCY SPECIFICATIONS Mo Breakthrough Every Elution <0.15 mCi Mo/mCi Tc at tadministration Al3+ Breakthrough Every Elution <10 ppm of Al3+; may be expressed as mg/ml

OPTIONAL QC TESTING OF A Mo/Tc GENERATOR TEST FREQUENCY SPECIFICATIONS HR Tc Every Elution < 2% (Reasonable limit; presently no legal limit)

QC test procedures for mo/Tc generator Mo-99 breakthrough: Mo-99 is assayed directly in the special lead pig supplied by manufacturer of your dose calibrator. Tc-99m is then assayed directly in the plastic sleeve. Activity (mCi) of mo-99 is divided by activity (mCi) of Tc-99m to obtain a ratio.

QC Test Procedures for Mo/Tc Generator Mo-99 Breakthrough: If this ratio is <0.15 mCi Mo-99 per mCi of Tc-99m at time of administration, the generator eluate has passed the Mo-99 Breakthrough Test. As a rule of thumb, if the ratio is <0.038 at time of elution, the material will be suitable for injection for at least 12 hours.

with your dose calibrator with your dose calibrator Mo-99 Breakthrough Test Step 1 Step 2 Special Pb pig designed for use with your dose calibrator Plastic sleeve designed for use with your dose calibrator

QC TEST PROCEDURES FOR Mo/Tc GENERATOR Aluminum Ion Breakthrough: Al3+ ion is measured colorimetrically. A drop of the eluate is placed on one end of a special test paper; a drop of a standard solution of Al3+, concentration 10 ppm, is placed on the other end of the test strip. If the color at the center of the drop of eluate is less red than that of the standard solution, the eluate has passed the Al3+ Ion Breakthrough Test. Units may be also be expressed as mg/ml.

Aluminum Ion Breakthrough Test Special paper saturated with aluminon reagent, sensitive to Al3+ on a ppm basis Generator Eluate 10 ppm Al3+ standard If “generator eluate” spot is less red than “Al3+ standard” spot, then eluate has passed the Al3+ ion breakthrough test.

Radiochemical Impurities in 99mTc Radiopharmaceuticals Free Tc Chemical form: pertechnetate, TcO4- Hydrolyzed Reduced Tc (Chemical form is probably TcO(OH)2.H2O, a hydrated Tc-oxide For 99mTc MAG3, possible impurity is 99mTc tartrate For 99mTc HMPAO, there are stereochemical impurities.

THIN LAYER CHROMATOGRAPHY SYSTEMS OF Tc-99m COMPOUNDS Tc-99m DTPA, MDP, GH, PYP, HDP, MAA, MIAA, SC SYSTEM IMPURITY MEASURED 1. Silica Gel/0.9% saline Hydrolyzed Reduced Tc 2. Paper/acetone or Free Tc (Pertechnetate) paper/MEK

Tc-99m CHROMATOGRAPHY: SEPARATION ON STRIP SEPARATION OF SYSTEM RADIOCHEMICAL SPECIES Silica Gel/saline HR Tc in bottom half; all other species in top half. Paper/acetone or Free Tc in top half; all other paper/MEK. species in bottom half.

THIN LAYER CHROMATOGRAPHY SYSTEMS: Tc-99m HEPATOBILIARY AGENTS SYSTEM IMPURITY MEASURED ITLC-SA/20% saline Free Tc (Pertechnetate) ITLC-SG/water Hydrolyzed Reduced Tc

Tc-99m CHROMATOGRAPHY: SEPARATION ON STRIP SEPARATION OF SYSTEM RADIOCHEMICAL SPECIES ITLC-SA/20% saline HR Tc in bottom half; all other species in top half. ITLC-SG/water Free Tc in top half; all other species in bottom half.

EXCEPTION TO THE RULE For insoluble Tc-99m Radiopharma-ceuticals (e.g., Tc-MAA, Tc-SC), it is only necessary to test for the presence of free Tc. No simple system can effectively separate colloidal HR Tc from an insoluble product, so HR Tc cannot be measured in these products. We therefore ignore its presence.

STRIP DESIGN top of strip 6 cm solvent front 5 cm cut line 3 cm origin 1 cm strip bottom 0 cm

Labeling efficiency =100% - % HR Tc - % Free Tc CALCULATIONS % Impurity = CPM IN HALF OF STRIP X 100% CPM IN WHOLE STRIP Labeling efficiency =100% - % HR Tc - % Free Tc

Migration Patterns of Tc-MDP Paper/acetone Si gel/saline Free Tc Tc-MDP HR Tc

Migration Patterns of Tc-MDP Paper/acetone Si gel/saline 1,000 99,000 99,000 1,000 Free Tc Tc-MDP HR Tc

Results % free Tc = 1,000/(1,000 + 99,000) = 1 % % HR Tc = 1,000/(1,000 + 99,000) = 1 % therefore, % Tc-MDP = 100 % - 2 % = 98%

Quality Control Of Dose Calibrators Test Frequency Regulatory Agency Accuracy Annually NRC/Dept Of Nuclear Safety Constancy Daily NRC/Dept Of Nuclear Safety Linearity Quarterly NRC/Dept Of Nuclear Safety Geometry Tinstallation NRC/Dept Of Nuclear Safety

GEOMETRY TEST MUST ALSO BE PERFORMED AFTER REPAIR, RECALIBRATION OR AFTER MOVING INSTRUMENT

ACCURACY TEST This test is designed to show that the calibrator is giving correct readings throughout the entire energy scale that we are likely to encounter. Low, medium, and high energy standards (usually Co-57, Ba-133 or Cs-137, and Co-60, respectively), are measured in the dose calibrator using appropriate settings. Standard and measured values are compared.

ACCURACY TEST: Tc-99m Standard Energy expected measured (keV) value (mCi) value (mCi) Co-57 122 2.48 2.51 Cs-137 662 3.38 3.29 Co-60 1,332 1.55 1.52

CONSTANCY TEST This test measures precision and is designed to show that a long-lived source, usually 30 y Cs-137, yields reproducible readings on a daily basis on all isotope settings we are likely to use. The Cs-137 source is placed in the dose calibrator. Activity is then measured on the Cs-137 setting and all other settings used on a daily basis. Values are recorded in the dose calibrator logbook and are compared with recent values to determine if instrument is maintaining constancy on a daily basis.

CONSTANCY TEST USING Cs-137 Isotope Reading (mCi) Setting Mon Tues Wed Thu Fri Cs-137 123 124 122 126 124 Ga-67 223 224 222 226 224 Tl-201 163 164 162 166 164 Tc-99m 243 244 242 246 244 I-131 313 314 312 316 314 I-123 193 194 192 196 194 In-111 283 284 282 286 284 Xe-133 433 434 432 436 434

LINEARITY TEST This test is designed to prove that the dose calibrator readout is linear for sources varying from the mCi range through the mCi range. A high activity Tc-99m source (50-300 mCi) is measured at T0 and at predetermined time intervals up to 48 hours. Expected and actual measurements are compared (and may be analyzed graphically) to determine if the instrument is linear throughout the activity range we are likely to encounter.

LINEARITY TEST: Tc-99m Elapsed expected measured time (hr) value value 0 300 300 1 267 272 2 238 241 3 212 209 6 150 148 12 75 72.4 24 18.75 19.1

GEOMETRY TEST This test is designed to show that correct readings can be obtained regardless of the sample size or geometry. One ml of Tc-99m in a 10 ml syringe (activity 25 mCi) is measured in the dose calibrator and the value obtained is recorded. The activity is then diluted with water to 2 ml, 3 ml, 5 ml, and 10 ml. At each of these points a reading is taken and the value recorded. Data are then evaluated to determine the effect of sample geometry on the dose calibrator reading. If instrument is geometry-dependent, it may be necessary to routinely correct readings obtained when using calibrator.

GEOMETRY TEST: 10 ml SYRINGE Sample Volume Activity (mCi) 0.5 25.5 1.0 25.3 2.0 25.0 3.0 24.8 4.0 24.7 5.0 24.5 8.0 24.4

Specifications: Dose Calibrator QC Tests 1. Deviation from standard or expected values must be within + 10%. 2. If Deviation > 10%, then obligation is to record value, note repair or recalibration of instrument, retest, and record new values. 3. In addition to the above steps, every dose must be corrected mathematically until the instrument is repaired. There is NO LONGER a reporting requirement.

FULL-WIDTH HALF-MAXIMUM VALUE Determines ability of a sodium iodide (thallium) or solid state crystal to resolve gamma ray energies. Measures only resolution, not sensitivity. for NaI(Tl), Normal Value is 6-10% for Ge(Li) Crystal, typical value is <1% across entire energy spectrum.

FULL-WIDTH HALF-MAXIMUM VALUE % FWHM = DE x 100% Epeak

What is % Full Width Half Maximum for the Curve Shown Below? E = 662 keV E = 70 keV

Full Width Half Maximum Determination E = 662 keV % FWHM = DE x 100% Epeak % FWHM = 70 x 100% = 10.6 % 662 E = 70 keV