Float Switches Water level control.

Slides:



Advertisements
Similar presentations
P f a n n e n b e r g Group © Since 2008 company Pfannenberg introduced a new Range of Alarming Products, as so called Marine Range. The main characteristic.
Advertisements

Welcome Herzlich Willkommen Bienvenue JUMO eTRON T data sheet
Motorized Pulley Presentation
Automation and Drives s SIRIUS 1 s SIRIUS Soft Starts.
Automation and Drives s SIRIUS 1 s s SIKOSTART Soft Starts.
Fill in missing numbers or operations
As a stand-alone overview of test tools.
Ohms Law Physics Dr. Robert MacKay. Voltage (Volts) Electrical Pressure V.
Random BuiltIn Function in Stella
Electricity Merit Badge
Energy, Water Consumption & Carbon Emissions June 2010.
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface VIA ROMA, 20 - I CREAZZO (VI) ITALY PHONE
SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead.
SAE J1772™ Gery J. Kissel Engineering Specialist General Motors
It all started simple…. One Alternator One Battery One Starter Motor.
18/05/2001Autotuning1. 18/05/2001Autotuning2 Why to Use Autotuning Inverter needs motor equivalent circuit data for internal calculations to achieve maximium.
Solid level measurement
SITOP select Automation and Drives SITOP select Electronic Diagnosis Module Fault diagnosis – rapid and reliable.
Smart heat for comfort and safety 1 Self-regulating system to maintain water flow in gutters and downpipes.
Welcome to PHOENIX CONTACT Masterversion 13 Electromagnetic and electronic circuit-breaker CLIPLINE complete.
Traction electrical equipment
MEGATRON. Privately owned shares company founded at The company is engaged in manufacturing Measu- rement, Monitoring and Control equipment. Megatron's.
3442 Industrial Instruments 2 Chapter 7 Final Control
SITOP power facets A&D SE PS SITOP power Automation and Drives SITOP power flexi The power pack handles it all - from 3 to 52V SITOP power.
Marks out of 100 Mrs Smith’s Class Median Lower Quartile Upper Quartile Minimum Maximum.
© ABB STOTZ KONTAKT ABB MCB Tripping – Characteristics MCB´s Knowhow ABB STOTZ KONTAKT.
Automation and Drives SIRIUS SC Solid State Switching Devices SIRIUS SC Solid State Switching Devices How Do I Select the Right Heat Sink for my Solid.
HS-30 Hydrostatic Pressure Sensor Presented By Peter Ward Hydrological Services Pty Ltd.
Power and AC.
Factoring Grouping (Bust-the-b) Ex. 3x2 + 14x Ex. 6x2 + 7x + 2.
QR026 High Sensitivity VME Tuner Performance Data
Practical Considerations for Digital Design
Service Export VICTRIX. VICTRIX Instantaneous boiler  VICTRIX 26 2 I Heating only prearranged for external cylinder connection  VICTRIX X 12 2 I  VICTRIX.
Complete Quiz You have 10 minutes to complete the quiz The Quiz is Open-Book (use it) Get help from your neighbor.
Bring Your Smart Module System to Life Design Agenda Solution Overview System design 1.Design your smart module layout 2.Determine how many Gateways.
MECHATRONICS SENSORS.
1 Engine Protector Safe Rider Vehicle Technologies (Pty) Ltd PO Box 11376, Rynfield South Africa Tel./ fax Cell:
WATER LEAK DETECTION SYSTEM
You can Measure the Benefits… Training Course SolidScan’s products.
New England Association Of Fire Protection System Designers Rick Dumont.
MINIMUM ACCEPTABLE LEVELS OF SAFETY & RELIABILITY
Class exercise 1 Find the equivalent resistance of the following circuit.
MonoDrive & XT Constant Pressure Controller
12. Power Distribution Systems 1) Schematic diagram of part of a house wiring system 1.
Discrete-state Process Control
Experts in Chem-Feed and Water Treatment beta Metering Pumps 1.
LOOP TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
Simple Water Level Controller Circuit with Microcontroller and Alarm.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
AC Machines. BOOSTER Basic Function:- -Sometimes when we use electrical power we need different voltage level to main supply. It is provided by Booster.
Diehl AKO Stiftung & Co. KG, Appliance Europe, Pfannerstraße 75-83, DE – Wangen Tel. +49 (7522) 73-0 Fax +49 (7522)
Circuit 2Power 1 Basic Definitions Power : the rate at which energy is transferred from one form to another By considering the Ohm’s law, electrical power.
DVOM Not-So Basics.
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
ABB i-bus® KNX Weather Station
INDUCTION MOTOR PROTECTION FOR SINGLE PHASING, OVERVOLTAGE AND OVER TEMPERATURE Submitted by:
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
Schematic diagram of part of a house wiring system
Relay operation Water level Indicator
Basic Definitions Power 1 Circuit 2
Power Block Implementation
1) Schematic diagram of part of a house wiring system
Electric Current.
ABB i-bus® KNX Analogue Input
Electromagnetic Relay
Presentation transcript:

Float Switches Water level control

Float Switches Water level control 2 designs of float switches are available Industrial heavy duty Domestic or economy Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com

Float Switches Water level control There are two types of industrial float switch Standard switch which is rated up to 13 amps Intrinsically safe float switch will only take a very low voltage control signal Both float switches look identical except for the marking on the base, the ATEX Intrinsically Safe switch will be stamped on the base with the IS Industrial float switch Industrial float switch ATEX approved IS Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com

Atex approved Water level control Float Switches Atex approved Water level control Atex float Max Input Parameters: Ui = 30V, Ii=100mA 8v, 8mA dc minimum contact rating Type Atex ( Certificate SIRA 04ATEX2187) may be used in zones 1 and 2 Temperature range –20°C to +70C and should not be used outside this range Max. submerged depth 20 metres Chemical resistance Industrial float switch ATEX approved IS Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com

Float Switches Water level control Standard switch which is rated up to 240v 15 amps non inductive, 240v 10 amps inductive Maximum size of electrical motor that may be switched is 1.3 hp, 230 v, 50 hz Maximum water depth is 20m You may switch the power via the float switch, but the best and safest arrangement is to use a low voltage such as 12 to 24v ac or dc through the switch, and use a relay to switch the pump on / off. By this means large electrical motors / pumps may be controlled Chemical resistance Industrial float switch Standard Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com

Float Switches Water level control Economy switch has the same specification as the standard switch Rated up to 240v 15 amps non inductive, 240v 10 amps inductive Maximum size of electrical motor that may be switched is 1.3 hp, 230 v, 50 hz Maximum water depth is 20m You may switch the power via the float switch, but the best and safest arrangement is to use a low voltage such as 12 to 24v ac or dc through the switch, and use a relay to switch the pump on / off. By this means large electrical motors / pumps may be controlled Chemical resistance Economy float switch Polypropylene casing and PVC cable High level of chemical resistance Suitable for most water applications Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com

Float Switches How do they work 2 designs of float switches are available Both float switch work in the same way Standard switch has integral weight, economy switch has a separate weight The weight acts as the pivot point for the switch When the switch tilts to the angle shown an electrical circuit is made or broken Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com

How do they work, electrically Float Switches How do they work, electrically The economy and standard floats have the same wiring The switches have three wires, brown, black & blue The Brown wire is the common By connection of Brown & Black, or Brown & Blue wires the electrical circuit may be made or broken, you therefore have the option of normally open or closed circuit on filling or emptying Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com

Float Switches Applications For ATXE application or potentially explosive environments contact Dryden Aqua The standard and economy switches may be used for all aquatic environments Some examples Tanks Lagoons Basement protection from flooding River and lake level Water treatment system Pumping stations Many industrial applications Dryden Aqua float switches are used when you require a simple yet robust means of controlling water levels Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com

Float Switches Water level control Contact Dryden Aqua for more information or to place an order You may order on-line from www.DrydenAqua.com Dryden Aqua Ltd | Butlerfield | Bonnyrigg | Edinburgh EH19 3 JQ | Tel 018758 22222 Fax 018758 22229 www.DrydenAqua.com