Air Release Valve Series ARV Product Education Course.

Slides:



Advertisements
Similar presentations
SKA-Pak Plus Mobile Air Cart Con-Space Link
Advertisements

Degassing Valve for Corrosive & Ultra-pure Liquids Series DGV US Patent #7,481,238 B2.
Purpose of a VPA Filling & Metering Pump… Imagine having an employee who constantly measures out a precise dose of liquid whenever it’s needed.
Diaphragm Check Valves Series CKM Patented Design.
Flow Control Valves Series FC
City of Black Hawk Water HammerSeptember 2002 Arber Water Hammer Travis Meyer, P.E. Richard P. Arber Associates.
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
STEAM TRAPS.
©2008 Armstrong International, Inc. Basic Steam Trap Operation.
Finally, a compressed air piping system so simple…it’s EZ!
1 Oil Fuel Line De-aerators What they are, what they do and how to install.
Reservoirs Covered in Ch. 5 of Vickers Text
2.3.9 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Purging Containers & Injecting Methanol Prior to.
Filling, purging and air removal
Lesson 25 TWO-PHASE FLUID FLOW
Condensation Piping and Installation Drain Pans
Fluids Review.
Water Hammer.
HYDRAULIC DESIGN.
Pump Installation Vigyan Ashram, Pabal.
Book 2: Chapter 6 Line Pipe and Fittings.
Valves and Appurtenances
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Connecting to industry 1. 2 Safety Break-away Couplings.
Hydronic Mechanical Controls
Module C Sprinkler systems (4-20)
Lease Automatic Custody Transfer
Asahi/America Type 21 Ball Valves Type 21 Ball Valves.
SEWER PIPING DESIGN Sewer piping differs from water piping, in that sewer pipes are not under pressure. The function that takes place inside sewer pipes.
3.7.5 Student Book © 2004 Propane Education & Research CouncilPage 1 A full understanding of the operation of the liquid evacuation process if essential.
Mounting Direction Water Cooler Best solution OK Risk of air bubbles in the system Heatsink Water channels Inlet Outlet.
Components of Centrifugal pumps
Asahi/America Thermoplastic Check Valves Ball Check Valves ½” - 4”PVC, CPVC, PP, PVDF Uniseat/ Seal.
GIDC DEGREE ENGINEERING COLLEGE BRANCH- CIVIL ENROLLMENT NO PATEL SHARADKUMAR KIRITBHAI SHARMA TANISHQ SHAH ASHIT.
HVAC523 Basic Subsystems.
Dr. subhash technical campus
Testing and Information
Gasoline fuel supply systems Function: store, transport, Pressurize and filter gasoline going to carburetor or fuel injection system.
Northvale Korting Fluid Jet Theory and Applications of Eductors By Patrick Belcher.
EVAPORATIVE EMISSION CONTROL SYSTEMS
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Principles of Carburetion
1 INNOVATION EXPERIENCE SYNERGY COMMITMENT CREATIVITY Air Valves.
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
What tests are necessary to make sure your kegs are being cleaned, sanitized and filled correctly By Andrew J. Brewer
Introduction to Energy Management
MODULE 2 Operate the Propane Liquid Supply System.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
Automotive Engines: Theory and Servicing, 7/e By James D. Halderman Copyright © 2011, 2009, 2005, 2001, 1997 Pearson Education, Inc., Upper Saddle River,
Water Heaters 101 Residential Gas and Electric. Outline Basic water heater features Residential gas overview Residential electric overview Q&A.
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
Hydraulic Pressure Control
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
System One Pumps S1-200 Centrifugal Hydraulics
CENTIFUGAL PUMP OPERATION
VALVES IN PIPE LINES.
Prepared by: Patel Nirav ( )
Septic systems.
EVAPORATIVE EMISSION CONTROL SYSTEMS
Real Solutions Product Introduction
Hydraulic Pressure Control
Pumps and Lift Stations
Asahi/America Ball Check Valves
Fuel Supply System Chapter 21 Lesson 1.
Asahi/America Ball Check Valves
Degassing Valve for Corrosive & Ultra-pure Liquids • Series DGV
NAF ProCap Water Mirror concept
Presentation transcript:

Air Release Valve Series ARV Product Education Course

3 ways air enters a piping system: 1.It is there to begin with, unless the piping system is assembled in a vacuum. 2.It enters mechanically, drawn through pumps, seals, valves, fittings etc. while the system is operating. 3.It enters as part of the liquid, then outgasses from the liquid.

How much air is found in the average piping system? Entrained Air represents 2% of the average municipal water supply. When this outgasses, it joins existing air at system high points. In a 100 foot piping system, this represents a 2 foot slug of air…in 1000 ft., it adds up to a 20 ft slug of air…regardless of pipe diameter.

What does air do in a piping system? 1.Liquid flow causes it to move along, until it collects at high points.

2. As air collects, it reduces the area available for flow. These flow restrictions reduce the efficiency and performance of the piping system.

3. The air pocket grows, velocity increases...

4. Velocity & pressure build until the air pocket is swept downstream at dangerous speed...

End Result of Air in a Piping System: Rapid Venting of Air Water Hammer Pressure Surges System Damage

Common remedies… Connect a long run of vertical pipe to a ball valve on a tee. Open the valve at system start-up to allow air to escape, then close it as the pipe fills. Install an Air/Vacuum valve on the tank. Drawbacks… The ball valve is not automatic; if someone forgets to open or close the valve, the results can be disastrous. A tank mounted valve is only effective for air in the tank – won’t purge air trapped elsewhere in the system.

Ball-type Air Release Valves are Ineffective… Competitive air release valves are based on a floating hollow plastic ball. Plast-O-Matic engineers worked on a similar product, but extensive testing proved that the floating ball concept is inherently flawed. Ball floats too easily – too much air remains trapped Even brief exposure to pressure causes the ball to become out-of-round and difficult to seal. Prolonged exposure to pressure makes it extremely out-of-round…impossible to seal

A Real Solution to the Problem… The Plast-O-Matic Series ARV Air Release Valve: A normally-open valve that allows air to escape Self-guided poppet closes when liquid rises.

How it works…

Where to use it… High points Tanks

Specifications: ½", ¾" & 1" NPT connections NPT outlet – permits corrosive vapors and emissions to be piped safely away PVC or CPVC body materials Viton FKM or EPDM seals No metal parts Liquid must have specific gravity of.9 or higher.

Performance: Closes at 0 psi as long as liquid is present. Bubble tight seal at 10 psi (EPDM) or psi (Viton FKM) Max pressure rating º F Max Air Flow Rate 8 SCFM Max liquid flow rate 60 GPM (use additional units for higher flow rates)

Advantages vs. Competition: 1.Self-guided poppet does not become egg- shaped, such as floating ball designs. 2.NPT outlet simplifies piping for applications with potentially hazardous emissions. 3.Union nut enables valve to be opened and inspected/cleaned easily – no tools required. 4.Density of poppet enables it to stay open longer than floating ball – more air is expelled prior to closing.

Series ARV Air Release Valve