WARM Program Combustion Safety Testing Field Training October 21, 2008 Holiday Inn Conference Center, New Cumberland, PA.

Slides:



Advertisements
Similar presentations
For Steam Boilers & Hot Air, Fresh Air, et al.. Thermostat Demand Analysis over time resets burner fire time for steam boiler. This will remove the leads.
Advertisements

Carbon Monoxide in Your Home. What is Carbon Monoxide? CO Deadly gas Cant see, taste, feel or smell.
Factor of Evaporation: lbs/hr steam produced per BHp.
Furnaces also called Fired Heaters
How to lower the energy use of your home David Parker Building Analyst/ Energy Auditor Parker Energy Solutions David Parker Building Analyst/ Energy Auditor.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Lecture 36 Combustion Reactions.
The Importance of Combustion Testing Testo HVAC Distributor Training:
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Combustion Appliances
Problem How does the density of different woods affect how long the wood can burn?
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
ENERGY STAR Qualified Homes
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov House as a System WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Energy Efficient Process Heating. Energy Balance on Furnace.
Do Your Weatherization Standards Measure Up? WARM CHOICE Program Standards and Procedures Energy Essentials Core Contractor Training December 10 and 11,
Environmental Health Issue- Carbon Monoxide Presented by QBE Loss Control Services.
Combustion & Fossil Fuels Chapter Combustion (1.11) In combustion, a substance reacts rapidly with oxygen and releases energy. The energy may be.
DZAC January 2012 Opening Remarks Ken Fletcher. Items of Interest $25 Safety Spot Award Program to start this month Interpretation of safety signs 2.
35” CONDENSING GAS FURNACES Vent and Combustion Air System Design & Installation 1 Add Distributor Art and Text Here.
The House as a System 1. Air Temperature and Water Vapor.
Natural Gas Pipeline Safety EDM Services, Inc. April 2009.
Protecting Against Carbon Monoxide in Your Home
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Combustion Appliances WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Station 3 ?? Air Meters Combustion Analyzer Carbon Monoxide Carbon Dioxide Particles Air Flow Vane Anemometer Exhaust Flow Box Pressures CAZ Test.
Standardized Curriculum WAP Training Plans and Resources.
1 FIRE PREVENTION AND SAFETY IN THE HOME Name. 2 COMMON SENSE !!
WARM CHOICE Program Combustion Safety Testing Energy Essentials Core Contractor Training December 10 and 11, 2008 Four Points by Sheraton, Mars, PA A.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Training the Best Workforce! Larry D. Armanda Therma-View Infrared and Energy Consultants S. Williamsport, PA & A. Tamasin Sterner Pure Energy Coach LLC.
VENTING AND COMBUSTION AIR
WHO IS TLC HOME IMPROVEMENT, INC.?  FOR OVER 36 YEARS TLC HOME IMPROVEMENT, INC. HAS BEEN IN THE FOREFRONT OF THE HOME REMODELING INDUSTRY SERVING THE.
Metering and CO.
Gas Furnace Planned Maintenance
New Jersey Comfort Partners Program A. Tamasin Sterner, Pure Energy.
Your House as a Healthy System Bruce Stahlberg. Improvements / Remodeling When one has finished building one's house, one suddenly realizes that in the.
MORE THAN JUST STAYING WARM… BRANDY TOFT AIR QUALITY SPECIALIST LEECH LAKE BAND OF OJIBWE Home Heating.
Carbon Monoxide Safety
NFPA 54 National Fuel Gas Code Boiler Manufacturer ANSI Standards Local Codes Vent Manufacturer.
MODULE 5 Complete and Incomplete Combustion Characteristics.
1 Combustion Oil Fired Equipment. 2 OIL Combustion of oil fired equipment has the same basics of gas. Remember, Oil is a liquid and this must be converted.
Be the MVP in the CAZ: Combustion Testing for Beginners ESSN 1 Wednesday, April 21, :30 am to Noon 2010 National ACI Conference, Austin TX A. Tamasin.
Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.
Weatherization 201: Weatherization Works! Updated September 23, 2008.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Combustion Safety WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Lecture Objectives: Continue with power generation Learn basics about boilers and furnaces.
Why Weatherization? Low-income families often choose between heat and other necessities 33.8 million households nationally eligible for Weatherization.
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
Richard Kelly, D.I.T.1 Facilities Management and the Environment BSc in Electrical Services and Energy Management.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 10 Spillage Test.
1 HVACR215 – Mechanical for Oil Oil Combustion. 2 Combustion The burning of a substance. Rapid Oxidation The burning of a substance. Rapid Oxidation.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 4 Identifying Venting Requirements and Characteristics.
1 Combustion Efficiency Test. 2 Principles 1.Composition of flue gases 2.Flue gas smoke concentration 3.Temp of flue gas 4.Draft produced 5.Excess combustion.
1 HVACR116 – Trade Skills Testing for CO Troubleshooting Testing for CO Troubleshooting.
1 Mansel Nelson, ITEP–EEOP. 2 3 Safety Perform regular maintenance Avoid installing unvented (or "vent-free”) heating appliances Consider using only.
OE OXYGEN ENRICHED BURNER
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
Carbon Monoxide MAKING GAS SAFE. Carbon monoxide Carbon Monoxide can be produced by burning any fossil fuel – not just gas. It can be generated by: 
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Air pollution. What is air pollution? Air pollution is the presence of substances in the air that are harmful to health or the environment. It can be.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – March 2011eere.energy.gov COMBUSTION BASICS HEATING SYSTEMS FOR ENERGY AUDITORS AND INSPECTORS.
Math Review CAZ Volume and Air Free CO PPM Calculations
Unit 13 Oil-Burning Equipment
RESIDENTIAL CONDENSING GAS FURNACES Vent Design & Installation Training Spring 2014 UTC Building & Industrial Systems Confidential and Proprietary Information.
Furnaces (also called Fired Heaters)
Presentation transcript:

WARM Program Combustion Safety Testing Field Training October 21, 2008 Holiday Inn Conference Center, New Cumberland, PA

Controversial and Confusing Action Levels vary Terminology varies What do you do with unvented appliances? What do you do with coal stoves? How do you seal test holes? How far should WARM go to fix problems?

WARM Procedure Combustion safety testing has been required as part of the WARM program for many years. The procedure and action levels have recently been changed slightly.

Why Focus on Combustion Safety Now? Due to high natural gas and oil prices, more WARM customers have switched to using electric space heaters for their primary or sole heat. They then qualify for air sealing and insulation if their winter seasonal use is at least 2,000 kWh. But they likely have a gas water heater and may still use their fossil fuel heating system…. So… if you air seal a home with a fossil fuel system, ……..

Why Now? Continued So….. When air sealing or insulation is installed in a home with fossil fuel heating or water heating systems, the air exchange across the thermal boundary will (should) be reduced as part of the WARM installed measures. Any planned reduction in air flow (CFM -50Pa) means the combustion appliances must be checked BEFORE air sealing to be sure they are operating safely…. And they need to be checked AFTER air sealing to be sure they still operate safely.

Because… Air is needed for proper combustion. When air flow is restricted, combustion appliances can be starved for air. If a combustion appliance is starved for air, it wont burn properly and/or it pulls its combustion air down the flue and back-drafts. Back-drafting (spillage) is dangerous because the flue gasses contain CO and other bad things. We want to be sure the appliances operate safely.

Why Now? continued Also, if a customers summer seasonal use is at least 2,000 kWh, they qualify for cooling load reduction measures, including insulation and air sealing measures. These customers may have fossil fuel heating systems and/or water heaters.

More Why Now? Utilities and other PA programs are requiring Energy Auditors and Field Technicians to be BPI Building Analyst 1 Certified. Following BPI Standards for combustion testing and safety makes sense in PA right now.

Which WARM Customers Get Combustion Testing? Typical jobs: Defacto electric heat jobs Electric heat jobs with gas water heaters AC jobs receiving air sealing or insulation

Combustion Testing Includes: CO testing: ambient air, combustion appliance zone (CAZ), flues Gas leak detection Spillage and flame roll-out evaluation CAZ depressurization Draft evaluation Gas range testing

Combustion Safety Testing Audit Form Page 18 Combustion Safety Tests must be performed if: Conventionally vented combustion appliances exist and Air sealing is done – to reduce cooling load or to reduce heating load

Audit Form Page

Procedure COMBUSTION SAFETY SEPTEMBER, 2008 This section includes specifications relating to combustion appliance testing, related services and measures, and instructions for action when an unsafe condition is discovered. COMBUSTION SAFETY TESTING PROCEDURE The WARM Program Service Delivery Contractors and QA contractors must follow the most current Building Performance Institute (BPI) Combustion Safety Test Procedure for Vented Appliances and Combustion Safety Test Action Levels which served as a basis for this detailed procedure. For the purposes of this document, BPIs Combustion Safety Test Procedure for Vented Appliances, dated 4/07, BPIs Technical Standards dated 2/28/05, and BPIs Combustion Safety Test Action Levels document dated 4/07 were used. …….

Action Levels

The Big Picture Why Perform Combustion Safety Tests? When inadequate oxygen is present, in addition to CO2 being formed, Carbon Monoxide (CO) can be formed. This is our main concern. Carbon rich fuels, like Fuel Oils, can also lead to Carbon Particles, or Smoke, being produced.

Combustion Diagram The ideal operating range is a setting with excess air. IncompleteComplete Excess Fuel Excess Air Flue gas components Ideal operating range ofburners CO 2 O 2 Eff. Stoichiometric line Courtesy of Bill Spohn, Testo

Air Tight Building Negative pressure conditions in homes can create back-drafting of combustion appliances Common exhaust equipment (i.e. attic fan, bathroom exhaust, fireplace) can compete with the normal venting process of combustion appliances Graphics © COAD 1996 Courtesy of Bill Spohn, Testo

Sometimes Things Go Backwards Back-Draft Flame Roll-Out Spillage Graphic © Readers Digest 2001 Courtesy of Bill Spohn, Testo

Combustion Testing Video 16 minute video demonstrating the combustion safety testing procedure

What is flue gas? carbon hydrogen sulfur oxygen nitrogen water Oxygen(20.9%) water vapor Nitrogen (79%) Carbon dioxide CO 2 Carbon monoxide CO Sulfur dioxide SO 2 O 2 - balance Nitrogen oxide NO x Water vapor H 2 O Smoke (oil systems) fuel-residual ashes fuel air How is it formed? Courtesy of Bill Spohn, Testo

What is Carbon Monoxide ? CO originates from incompletely (oxidized) burnt carbon (fuel). It is very dangerous for human and animals, because it prevents the absorbstion of oxygen in the blood stream. Reasons for the formation: - fuel rich mixture - Improper venting - too early cooling of the flame (1128 F) CO is expressed in parts per million (ppm). Courtesy of Bill Spohn, Testo

CO Sources Fuel burning furnaces and hot water heaters Fuel burning boilers Fuel burning space heaters Kitchen ranges & ovens Auto emissions Attached garages Fireplaces Tobacco smoke Courtesy of Bill Spohn, Testo

Characteristics of CO Odorless Colorless Tasteless Mixes well in air Does not stratify Follows air flow in a structure Poisonous Courtesy of Bill Spohn, Testo

CO Health Effects 35 ppm NIOSH Permissible Exposure Limit – 8 hours 200 ppmNIOSH Ceiling– 15 minutes 200 ppmSlight headache with 2-3 hours 400 ppmHeadache within 1-2 hours 800 ppmSickness & twitching of limbs within 1- 2 hours; unconsciousness in 2 hours 1,600 ppmHeadache within 20 minutes; death within 2 hours 3,200 ppmDeath in 30 minutes 6,400 ppmDeath in minutes 12,800 ppmDeath in 1-3 minutes Courtesy of Bill Spohn, Testo

CO Testing Fuel Burning Appliances Sample from entry of home to exit of home Sample around all un-vented appliances Sample before draft diverter of atmospheric devices Sample where you may suspect CO Graphics © COAD 1996 Courtesy of Bill Spohn, Testo

Types of Furnaces Atmospheric – Natural Draft Buoyancy Creates NEGATIVE Pressure in Flue Induced Draft Fan Creates NEGATIVE Pressure in Flue Power Draft –Power Vent Fan Creates POSITIVE Pressure in Flue Condensing Sealed combustion

Calculating Combustion Efficiency Natural Gas Light Oil Heavy Oil Propane Wood Ambient Temp (combustion air) Oxygen O 2 StackTemp fuel Air Temp The analyzer uses the oxygen and net temperature measurements in fuel specific equations to give the efficiency, CO2 and excess air readings. Courtesy of Bill Spohn, Testo

Combustible Gas Leak Detection

Spillage, Flame Roll-Out, Backdrafting

Testing for CO in the Appliance Test undiluted CO

Testing Draft Notice the hole in the boiler flue pipe

Testing Draft Some combustion analyzers test for pressure as well as CO. This one records pressure (draft) in Inches of Water Column, IWC

Testing Condensing Furnaces Test under Steady State Operating Conditions Sample around burner (CO) Sample efficiency in plastic vent pipe (MFG or authority) Or sample in stack termination (CO) Follow Manufacturers Specs Graphics © COAD 1996 Courtesy of Bill Spohn, Testo

Venting Types Video 17 minute Gas Venting video

Gas Appliance Categories Cat. I fan-assisted gas appliance: negative pressure, a high vent temperature avoiding condensation and an integral fan drawing combustion air through chamber Cat. I gas appliance: negative pressure, a high vent temperature, Cat. II gas appliance: –negative pressure, low vent temperature causing excessive condensation Cat. III gas appliance: –positive vent pressure in the vent, a high vent temperature Cat. IV gas appliance: - positive vent pressure in the vent low vent temperature causing excessive condensation Courtesy of Bill Spohn, Testo

Unvented Appliances – Test Air- Free or Undiluted Gas Ranges CO Hot-Pot Gas Ovens Test CO Air free, undiluted Courtesy of Bill Spohn, Testo

Range Top CO Testing

Sealing Test Holes For double wall (B-vent) flue pipes, letters from vent manufacturers say to use high temperature, non-hardening sealant to plug the hole on the inner sleeve. Do the same for the outer sleeve, but cover with a patch of aluminum tape over the sealant. For single wall flue pipes, use the same, or metal plugs.

What If A Test Fails? If a test fails before air sealing and/or insulating: follow procedure – no air sealing until the problem is fixed If a test fails after air sealing and/or insulating: follow procedure – fix the problem

Bonus Video 6 minute Efficiency Video

What Information is Important? Combustion Efficiency 02, Temperature, Fuel Reduce Fuel Cost - Savings To determine Operating Condition Diluting effects of excess air (NO, NO2, SO2, CO) Weight of pollutant (lbs/Mbtu) Carbon Dioxide (CO 2 ) O 2 Reference (3%, air free) Emission Conversions Excess Air Extra Air for Combustion Courtesy of Bill Spohn, Testo

Typical Readings Gas Fired Power Burners Oxygen : 3 % - 6 % Carbon Dioxide:8.5 % - 11 % Stack Temp : 275 ºF to 570 ºF Draft: -.02WC to -.04WC in the Stack Carbon Monoxide:<100 ppm (diluted) Always Follow Mfrs Specifications Courtesy of Bill Spohn, Testo

Typical Readings Oil Fired Power Burners Oxygen (cast iron cone): 4% - 7 % Oyygen (flame retention): 3%-6% Carbon Dioxide10 – 12.5% Stack Temp (60-79 AFUE): 400 ºF to 600 ºF Stack Temp (80 plus AFUE): 330 ºF to 450 ºF Stack Temp (90 plus AFUE): Less than 125ºF Draft: -.02WC Overfire Carbon Monoxide:< 50 ppm (diluted) Always Follow Mfrs Specifications Courtesy of Bill Spohn, Testo