Filtering Signal Processing.2

Slides:



Advertisements
Similar presentations
Clinical Applications of Spectral Analysis Winni Hofman, PhD University of Amsterdam Medcare Amsterdam.
Advertisements

Chapter 3. Amplifiers and Signal Processing John G. Webster
Analog-to-Digital Converter (ADC) And
7th Lecture Dimitar Stefanov. Recapping Three types electrodes are used for sensing of EMG signals: 1.indwelling (intramuscular) electrodes (single fiber.
Chem. 133 – 2/19 Lecture. Announcements Lab Work –Turn in Electronics Lab –Starting Set 2 HW1.2 Due Today Quiz 2 Today Today’s Lecture –Noise –Electrochemistry.
Differential Amplifier
Sinusoidal Waves. Objective of Lecture Discuss the characteristics of a sinusoidal wave. Define the mathematical relationship between the period, frequency,
Measurement of Voltages and Currents
Chapter-3-1CS331- Fakhry Khellah Term 081 Chapter 3 Data and Signals.
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
5/4/2006BAE Analog to Digital (A/D) Conversion An overview of A/D techniques.
TRANSMISSION FUNDAMENTALS Review
Pre-processing for EEG and MEG
Analog Data Processing with BioProc3 Part Two EMG Analysis Techniques.
EE 4272Spring, 2003 Chapter 3 Data Transmission Part II Data Communications Concept & Terminology Signal : Time Domain & Frequency Domain Concepts Signal.
Chapter 3 Data and Signals
Department of Electronic Engineering City University of Hong Kong EE3900 Computer Networks Data Transmission Slide 1 Continuous & Discrete Signals.
William Stallings Data and Computer Communications 7th Edition (Selected slides used for lectures at Bina Nusantara University) Data, Signal.
Module 3.0: Data Transmission
Chem. 133 – 2/17 Lecture. Announcements Lab Work –Electronics Lab Report due 2/19 –Let me know by today if you plan to do a lab practical instead –Half.
1 Announcements l Bring motors to lab this week. l Bring eight 1N4001 diodes to lab per team. Get them at the Scientific Supply Store (2 nd Floor Sciences.
Chapter 5 Signals and Noise  Signal carries information about the analyte that is of interest to us.  Noise is made up of extraneous information that.
Electromyography: Recording D. Gordon E. Robertson, Ph.D. Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
Inputs to Signal Generation.vi: -Initial Distance (m) -Velocity (m/s) -Chirp Duration (s) -Sampling Info (Sampling Frequency, Window Size) -Original Signal.
EKT314/4 Electronic Instrumentation
Lecture 1 Signals in the Time and Frequency Domains
1-1 Basics of Data Transmission Our Objective is to understand …  Signals, bandwidth, data rate concepts  Transmission impairments  Channel capacity.
1 Business Telecommunications Data and Computer Communications Chapter 3 Data Transmission.
Differential Amplifier
Tesla’s Alternating Current Dr. Bill Pezzaglia Updated 2014Mar10.
3 SIGNALLING Analogue vs. digital signalling oRecap advantages and disadvantages of analogue and digital signalling oCalculate signal transmission rates.
Electromyography (EMG) Theory of Operation & Underlying Anatomical and Physiological Issues.
EMG Analysis and Interpretation
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
ELECTRONIC INSTRUMENTATION & PLC DKT Signal Conditioning Circuits.
Active Filter A. Marzuki. 1 Introduction 2 First- Order Filters 3 Second-Order Filters 4 Other type of Filters 5 Real Filters 6 Conclusion Table of Contents.
Quiz 1 Review. Analog Synthesis Overview Sound is created by controlling electrical current within synthesizer, and amplifying result. Basic components:
Electromagnetic Spectrum
Measurements & Electrical Analog Devices (Part 2).
Filters By combining resistor, capacitor, inductor in special ways we can design circuits that are capable of passing certain frequency while rejecting.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
Chem. 133 – 2/16 Lecture. Announcements Lab today –Will cover last 4 set 2 labs + start on set 2 labs –Lab Report on electronics labs – due 2/23 (I planned.
Chem. 133 – 2/18 Lecture. Announcements Homework Set 1.2 (bold problems) – due today Quiz 2 Today Electronics Lab Reports – due Tuesday Seminar this Friday.
Muscle Fatigue Interface Final Presentation Shay Chen, Tushar Bhushan, Roman Levitas TA: Lydia Majure ECE 445: Senior Design Project #30 April 1, 2013.
Electromyography E.M.G..
Comparison Between AM and FM Reception. 21/06/20162 FM Receiver.
A function generator is usually a piece of electronic test equipment or software used to generate different types of electrical waveforms over a wide.
 What is Filter ? A Filter is an electrical network that can transmit signal within a specified frequency range. This Frequency range is called PASS BAND.
FUNCTION GENERATOR.
Báo cáo đồ án Thông Tin Số (CT386) Nhóm 2: 1.Cao Kim Loan Lâm Quốc Sự Bộ môn Điện Tử Viễn Thông GVHD : TS.Lương Vinh Quốc Danh.
Chem. 133 – 2/14 Lecture.
ELECTRONIC INSTRUMENTATIONS
Test! OpAmp Active Filters
Electronic Devices Ninth Edition Floyd Chapter 15.
MECH 373 Instrumentation and Measurements
Three types electrodes are used for sensing of EMG signals:
(4) Filters.
MECH 373 Instrumentation and Measurements
ALTERNATING CURRENT AND VOLTAGE
Chem. 133 – 2/16 Lecture.
Electromyography E.M.G..
POWER AMPLIFIERS.
Lesson 7: Anti-Aliasing Filtering
Electromyography E.M.G..
Amplifiers Classes Electronics-II
Amplifiers Classes Electronics-II
Chapter 3 ACTIVE FILTER.
8.5 Modulation of Signals basic idea and goals
Computer Networks Bhushan Trivedi, Director, MCA Programme, at the GLS Institute of Computer Technology, Ahmadabad.
Chapter 5: Active Filters
Presentation transcript:

Filtering Signal Processing.2 The EMG Signal Filtering Signal Processing.2

Filters - Overview Primary function is noise attenuation If the frequency of the noise source is sufficiently different from the frequency components of the signal waveform of interest - the noise can be removed providing a “cleaner” EMG signal

Filters - Overview Frequency range of muscle - slow twitch motor units (20) 70 - 125 Hz

Filters - Overview Frequency range of muscle - slow twitch motor units Fast twitch motor units 125 - 250 Hz

Filters - Overview Frequency range of muscle - slow twitch motor units Fast twitch motor units Sources of noise that “compete” with these frequency ranges Attenuate or make the true signal less visible and difficult to interpret Example: 60 Hz from 120 V power lines

Filter Types Hardware filters Software filters Analog electronic circuit Amplifiers, resistors, capacitors Software filters “Digital” filters Mathematical algorithms Butterworth Filter.vi

Frequency Components Bandwidth Low frequency cut-off Range of frequencies from the low frequency limit of the EMG signal to the high frequency limit = the band pass Low frequency cut-off High frequency cut-off Roll off Rate at which frequency attenuation occurs

Frequency Components

Filter Types by Frequency Component High frequency filter Removes high frequency components above a certain “cut-off” Low pass filter (LP) Pass = retain 20 Hz 250 Hz LP Filter

Filter Types by Frequency Component Low - High frequency filter Removes frequency components below and above certain “cut-offs” Band pass filter (BP) 20 Hz 250 Hz Filter BP Filter

Filter Types by Frequency Component 60 Hz Mid-range frequency filter Removes a specific frequency component within a range Band stop filter (BS) Example: 60 Hz filter 20 Hz 250 Hz BS

Roll Off Rate at which frequency attenuation occurs Expressed by the order The higher the order the more rapid the roll off Index of sensitivity of attenuation Butterworth Filter.vi

Phase Shift Filtering causes a change in phase = shift A time delay frequency component as it passes through the filter May cause waveform distortion especially if the the shift occurs near the cut-off frequency If the phase shift is small it may be a tolerable error source Shift

Phase Shift Solution

Filter Use Turn filter “On” Select type Insert cut-off(s) Run the VI

Practical Effect - Filtering Filtering will “sharpen” the image permitting better approximation of important events Onsets Offsets Etc.

Practical Effect - Filtering Raw Filtered

Signal Processing.2 Descriptive statistics Root Mean Square Signal spike counts Peak amplitude (voltage - mV) detection Averaging Variability analysis Root Mean Square

Descriptive Statistics Often used as a basic means of analysis after visual inspection of the raw data Probably more useful in quantifying “On-Off” phenomena May be used in conjunction with time-based analyses: onset, duration & offset

Signal Spike Counts More useful when muscle force levels are relatively low The interference pattern typical of high force levels (e.g., MVC) makes spike counts difficult

Signal Spike Counts Spike Counting by Window Spike Counting of Raw Signal - (could also be done with rectified signal)

Peak Amplitude Has traditionally been issued as an index of maximal muscle activity Probably valid when electrical activity is relatively constant A peak amplitude that exists more as an outlier may not be truly representative of typical or average activity Full-Wave Rectified Signal

Averaging (Mean) A data smoothing technique useful when high signal variability is of concern Moving average - the mean amplitude of a full-wave rectified window (segment) of data points for: Baseline noise (last session: “2 SD Method”) The true EMG signal Ensemble average - a mean of mean segments across subjects or trials

Variability Analysis.1 Reproducibility of recording electrodes (e.g., Δ’s in skin resistance; number of motor units sampled) with repeated measures designs is problematic Within subjects (e.g., over several days) Between subjects Report EMG amplitude (e.g., mean amplitude or integral - next session) as a percentage of a baseline MVIC

Variability Analysis.2 Variability assessment of EMG will document reproducibility/consistency SD: measure of dispersion about the mean stated in units of interest (mV) CV: describes dispersion of a group mean as a percentage SE: low SE argues sample mean is a good estimate of the population mean

Root Mean Square (RMS) One of several methods of quantifying EMG output (in mV) using Hardware or Software The “effective” value (quantity) of the EMG signal (i.e., not an average) Measures electrical power A form of linear envelope procedure

RMS Value Reflects Motor unit Electrode configuration Firing rates Duration Velocity of the electrical signal Electrode configuration Instrument (amplifier characteristics)

RMS Procedure Individual amplitudes are squared A mean of the squared amplitudes is calculated Square root is calculated

RMS - Time Constant Selected Hardware

RMS - Time Constant Selected Hardware Software

RMS - Time Constant Should be consistent with the nature of the activity being performed Slow movement Use a longer time Fast movement Use a shorter time

Reference Sources Gitter, A.J., & Stolov, W.C. (1995). AAEM minimongraph #16: instrumentation and measurement in electrodiagnostic medicine-part I. Muscle & Nerve, 18, 799-811.

Reference Sources Soderberg, G.L., & Knutson, L.M, (2000). A guide for use and interpretation of kinesiologic electromyographic data. Physical Therapy, 80, 485-498. Winter, D.A. (1990). Biomechanics and motor control of human movement (2nd Ed). New York: John Wiley & Sons, Inc., 191-212.