Facility Standards for Federal Records Storage Facilities

Slides:



Advertisements
Similar presentations
Underground Storage Tanks at Duke Duke Medical Center –8 permitted USTs located on medical campus –Range in size from 2,000 gallons to 30,000 gallons Proper.
Advertisements

NFPA-101, LIFE SAFETY CODE, 2003 EDITION Chapter 15 Existing Schools
WAYNE DALTON OF SYRACUSE PRESENTS:
Classroom Safety. Fire & Life Requirements as per State Education Dept The following list relates to the classrooms and adjacent areas. They are provided.
INSPECTION OF RISK AND ANALYSIS OF INSPECTION REPORT A PRACTICAL APPROACH PRESENTED BY AJAY K. JAIN.
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Regulations (Standards - 29 CFR) Flammable and Combustible liquids
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
Fired And Unfired Pressure Vessels
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
1 Procuring a Design Project engineers perspective on starting the design process and establishing the A/E scope of work Frank C. Quigley General Engineer.
FAA Office of Airports Airport Fuel Storage and Handling
Introduction to Records Management Policy
Biodiesel & Fire Permits Presented by the Seattle Fire Department for the Department of Ecology Biodiesel Permitting Workshop Seattle, Washington February.
Approaches to Fire Suppression in NARA Facilities: New Buildings and Renovations Ronald Noll, NCARB, AIA, CSI Real Property Branch Management Chief Space.
Subpart T Demolition These handouts and documents with attachments are not final, complete, or definitive instruments. This information is for guidance.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Protecting Your School Assets Through Loss Control.
The Life Safety Surveyor Facility Tour
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
Chapter 4 Licensing and Certification. Chapter Objectives 1.Understand the purpose of licensing 2.Identify the steps in the licensing process 3.Understand.
Indiana Federation of Ambulatory Surgical Centers September 27, 2013 To promote and provide essential public health services.
1 NOTES This presentation is an outline of some of the most important aspects of DOE O 440.1B For completeness, copies of the Order should accompany this.
Effective Workplace Safety Inspections OFFICE OF RISK MANAGEMENT LOSS PREVENTION UNIT.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Massachusetts Department of Public Health Bureau of Environmental Health Heating Systems and Enforcement of the Housing Code (In conjunction with the Department.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
Subchapter III: Company Certification Requirements.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
Construction Safety Council. by David G. Allie Subpart R - Steel Erection ( ) Tiered buildings not adaptable to temporary floors - Safety.
Emergency Action Plans
Residential Construction Unit 1 Mr. Todzia.  Definition-Legal requirements designed to protect the public by providing guidelines for structural, electrical,
Business Owners and Managers and the Fire Code
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
Presented by Steven P. Feltman Food Safety and Quality Specialist.
AC Transit Hydrogen Energy Station / Oakland Fire Department Project AC Transit Hydrogen Energy Station / Oakland Fire Department Project You want to do.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration.
Engineering Analysis of NFPA 285 Tested Assemblies
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Code Officials and the Code Process.  Concentrates on the code process as a whole.  Different type of code officials  Various steps that are taken.
Sprinkler Loads on Trusses
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
Sprinkler Loads on Trusses Educational Presentation.
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
Hot Work Permit Osan AB Fire Emergency Services.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
FACILITIES SERVICES NEW EMPLOYEE ORIENTATION. FUNCTION OF FACILITIES SERVICES  Facilities Services has 55 full time employees who are responsible for.
Fire Alarm Verification CAN/ULC-S561-03
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Fire Protection Systems Chapter 9 IBC 9th Edition Amendments
CITY OF HARARE EMERGENCY SERVICES
CIHQ - All Rights Reserved 2017
Acceptance Process for Manufactured Products by Certification:
29 CFR NFPA Life Safety Code
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
General Requirements of NFPA 101
Operationalizing Export Certification and Regionalization Programmes
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
OSU Controlled Substances Training Module for Researchers
Presentation transcript:

Facility Standards for Federal Records Storage Facilities 36 CFR §1228 Subpart K, “Facility Standards for Records Storage Facilities” and the NARA 1310 Checklist

NARA’s Authority under 44 U.S.C. 36 CFR §1228 Subpart K applies to all records storage facilities (whether Government owned, leased or contractor operated) that Federal agencies use to store, service, and dispose of their records. NARA Facilities NARA is authorized under 44 U.S.C. 2907 to establish, maintain, and operate records centers for Federal agencies. Agency Facilities NARA authorized under 44 U.S.C. 3103 to approve a records center that is maintained and operated by an agency. Commercial Facilities NARA is also authorized to promulgate standards, procedures, and guidelines to Federal agencies with respect to the storage of their records in commercial records storage facilities. (44 U.S.C. 2104a, 2904 and 3102).

What does Subpart K cover? This subpart of 36 CFR 1228 covers the establishment, maintenance, and operation of records centers. The subpart specifies the minimum structural, environmental, property, and life-safety standards that a records storage facility must meet.

Subpart K Facility Standards §1228.228 What are the facility requirements for all records storage facilities? §1228.230 What are the fire safety requirements that apply to records storage facilities? §1228.232 What are the requirements for environmental controls for records storage facilities?

§1228.228 Facility Standards (1/6) (a) Must be constructed with non-combustible materials (walls, columns and floors). (b) Multi-story facilities – must be designed or reviewed by both a licensed fire protection engineer and a civil/structural engineer. (c) Must be outside of the 100 year flood plain

§1228.228 Facility Standards (2/6) (d) The facility must be designed in accordance with all applicable codes. (e) There must be unrestricted emergency vehicle access provided to the facility. (f) The floor load limit – must be established by a structural engineer & posted in facility.

§1228.228 Facility Standards (3/6) (g) The roof system must prevent water from entering the facility. We recommend that there not be any roof mounted equipment above records storage areas. (h) No piping (with the exception of fire protection system piping) through records storage areas.

§1228.228 Facility Standards (4/6) (i) Records Storage and Racking Systems. Provide seismic bracing to meet applicable codes. Designed to prevent collapse under full load. If compact mobile shelving is used, there are specific requirements related to air circulation & fire-protection. Contact NARA.

§1228.228 Facility Standards (5/6) (j) The records storage area must be equipped with an anti-intrusion alarm system. (k) The design of the facility must meet the requirements of a Level III facility as defined by the U.S. Marshals Service. (l) Contaminated records must be stored in a separate storage area on a separate HVAC system. (m) The facility must have an integrated pest management program.

§1228.228 Facility Standards (6/6) For new records storage facilities (facilities established or converted after September 28, 2005): No motors over 1 HP in records storage areas. No high voltage equipment in records storage areas. Redundant source of primary power should be provided to insure continuous power. Positive air pressure for permanent records storage areas.

§1228.230 Fire Safety Requirements (1/3) Fire detection & suppression designed or reviewed by a licensed fire protection engineer. Three-hour fire barrier walls must be provided between storage areas. No more than 250,000 cubic feet of Federal records per storage area. Two-hour rated walls must be provided between records storage areas and auxiliary spaces, All penetrations through fire walls must be sealed with fire stopping material.. The roof fire rating must be a minimum ½ hour or protected by fire sprinklers. (f) Doors between records storage areas must be self-closing and have a Class A rating.

§1228.230 Fire Safety Requirements (2/3) (g) Roof supporting members that cross fire walls must be cut and supported independently on each side of fire barrier. (h) Expansion joints in fire walls must be properly protected. (i) Building columns in records storage areas must be 1 hour fire resistive or protect in accordance with NFPA 13. (j) No automatic roof vents for routine ventilation are allowed in records storage areas. Properly designed roof vents for fire venting are acceptable. (k) Light-weight steel must be protected with 10 minute fire resistant coating or large drop sprinkler heads. (l) Open flame unit heaters or equipment must be installed in accordance with NFPA 54 and the Uniform Mechanical Code.

§1228.230 Fire Safety Requirements (3/3) (m) Existing facilities – two-hour fire barrier wall separation with no openings between records storage areas and boiler rooms or rooms with fuel supplies (generator rooms). (n) New facilities – four- hour fire barrier wall separation with no openings between records storage areas and boiler rooms or rooms with fuel supplies (generator rooms). (o) New facilities - fuel supply lines must not be installed in records storage areas . Fuel lines must be separated from records storage areas by four-hour rated construction assemblies. (p) Equipment rows running perpendicular to walls must be NFPA 101 compliant. (q) No oil-based transformers are permitted in records storage areas – light ballast OK. Electrical wiring must be in metal conduit. Battery charging areas for electric forklifts require at least two-hour fire barrier separation from records storage. No hazardous materials are permitted to be stored in records storage areas – including nitrate film. (s) All records storage areas must have a professionally designed fire detection and suppression system designed to limit loss to a maximum of 300 cubic feet in case of a fire.

§1228.232 Environmental Controls Requirements (1/1) (a) Paper-based temporary records must be stored in a manner to prevent mold growth with no leaks or moisture problems and temperature /humidity extremes must be avoided. (b) Non-textural temporary records must be stored in conditions that preserve them based on their full retention period. (c) Paper-based permanent records must be stored in areas with 24 hour/365 days per year air conditioning equivalent to office space with appropriate temperature, humidity and air-exchanges. (d) Non-textural permanent records, unscheduled records and sample/select records must comply with the standards for permanent records.

Fire Suppression Performance The fire detection and suppression system must be designed and installed to limit the maximum anticipated loss in any single fire event to a maximum of 300 cubic feet of records. §1228.230(s)

Fire Suppression System Must be designed or reviewed by a licensed fire-protection engineer (LFPE) - §1228.230 Must be documented by: NARA Appendix B Live Fire Test LFPE Report & Seal - §1228.242

Appendix B Contains prescriptive requirements based on live fire testing.

Certifications Fire Detection System Fire Suppression System Floor Load Capacity Flood Plain Certification Integrated Pest Management Intrusion Alarm Certification (UL1076) Shelving Design & Installation for Seismic Requirements Temporary or Permanent? ASHRAE Standard 55 & ASHRAE Standard 62 may be required. Certificate of Occupancy

Establishing or Relocating an Agency Record Center Send a written request to: Director, Space & Security Management Division (NAS) National Archives and Records Administration 8601 Adelphi Road College Park, MD 20740-6001

Agency Record Center: Exclusion §1228.240(b) Exclusions … excludes agency records staging and/or holding areas with a capacity for containing less than 25,000 cubic feet of records … The facility standards still apply.

Commercial Records Storage Facilities The agency must certify that the facility meets the requirements of 36 CFR 1228, Subpart K. Submit documentation to NARA that the facility complies with the Standards. Reference the standards in storage/service contract. Must insure that NARA has the right to inspect the facility.

NARA Web Resources http://www.archives.gov Click on: Records Managers Contains information on NARA guidance and regulations and a listing of approved facilities

NARA Public Website www.archives.gov “Records Managers”

NARA “Records Managers” Page “Guidance and Regulations”

NARA Records Management Guidance and Regulations “NARA Regulations” Or … “NARA Bulletins”

NARA Regulations “Part 1228”

NARA Regulations, 1228 “Subpart K”

Facility Standards

NARA Bulletins from Guidance and Regulations Back to … “NARA Bulletins”

NARA Bulletins “2005-07” September 27, 2005

Click on “Attachment 2” for NARA 1310 Checklist NARA Bulletin 2005-07 Click on “Attachment 2” for NARA 1310 Checklist

Recap of what the Subpart K standards mean to you Agencies are responsible for ensuring that records in their legal custody are stored in appropriate space as outlined in Subpart K (36 CFR 1228.240(a)) If the current storage conditions are not in compliance, then the agency is responsible for initiating action to remove records from space that does not meet the Subpart K standards.

Recap of what the Subpart K standards mean to you If your agency stores records in a NARA facility, it is NARA’s responsibility to make sure the NARA Records Center facility meets the Subpart K standards. If your agency stores records in an agency records center, then the agency records officer is responsible for making sure the facility meets the Subpart K standards.

Recap of what the Subpart K standards mean to you If your agency stores records at a commercial records storage facility, it is the agency records officer that must make sure that the facility meets all of the requirements of 36 CFR 1228, Subpart K.

Recap - Agency Records Centers An agency must obtain NARA approval to establish or to relocate an agency records center (or to prior to using an agency records center operated by another agency). NARA will review documentation submitted by the agency to verify that the facility meets the requirements of Subpart K.

Recap - Commercial Records Centers If an agency elects to store the records in their legal custody at a commercial records storage facility, the agency must ensure that the facility meets the Subpart K standards. The agency must submit documentation to NARA that verifies that the facility meets the standards.

Recap - Commercial Records Centers Acceptable documentation required to verify compliance with the standards: A copy of the agency’s contract with the commercial records storage facility incorporating the Subpart K standards. A statement from the agency’s records officer certifying that the facility meets the requirements of Subpart K.

Additional information that can be submitted A copy of our NARA 1310 checklist that we use for inspecting compliance of a facility with the Subpart K standards. Information related to the fire protection system for the records storage facility.

What if the facility does not meet all of the Subpart K requirements? A waiver can be requested from a Subpart K requirement but the request for a waiver needs to be accompanied by information explaining how the alternative is equivalent or superior to the standard requirement. NARA reserves the right to approve or deny waiver requests

Next steps We are currently just under 2 years from the effective date for the standards. Through previous correspondence, we have identified where many of the federal records are stored. For agencies storing records at non-NARA records storage facilities, we will be issuing a letter soon requesting your certification of the facility.

Questions?