16 LED/Switch and HOA Modules

Slides:



Advertisements
Similar presentations
1 Series V4T 1/4 DIN Temperature Controllers. 2 3 Watlows Next Generation Styling Series 97 Matching 1/16 DIN Limit Controller Series F4S and F4D Ramping.
Advertisements

Prescient II Extinguishing Control Panels
Variable Frequency Drives Bypass Options
Immediate Communications Visual Management Automatic Data Collection Andons Real Time Performance Visibility Wireless Innovations for the Production Floor.
New BNWAS from AMI Target Market Large Fleets – All Vessels Price sensitive customers Global Fleets Crew Installs Small vessels.
Introducing Geoliner 660 an Imaging Evolution  New Multiprocessor Camera for increased Speed  Enhanced Cameras are VODI TM equipped for increased operator.
An Overview - by Neil Breakwell Overview - How the dash electronics is built up from a set of five “modules” The Basic Structure and Components of the.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA SD Mix-M Mode Mix-Minus Mode  Prevent echo due to this feedback.  Audio-signals,
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Assembly Manual Mike Fortney 04/09/2004 CricketSat Receiver.
AC-SSC-1 Installation and operation manual
D-901 Digital Mixer.  Rack-mount digital mixer  Modular design — up to 12 inputs and 8 outputs  Installed sound applications such as audio/visual,
1 Business Communication Systems (BCS) EXP1240 Series IP DECT Cordless System for Mobility EXP1240 Series.
- Product Overview – The LMD DEFLECTOMETER ® Series Inductive Loop Detector Why guess when you can know! © Copyright EDI 2013.
Basic Fire and Smoke Training Basic Fire and Smoke Actuators & Dampers.
1 Check all equipment is included before returning. If you have an accident or the equipment is damaged or you need support please contact Blaize
Material Handling Modules Configuring Your Own Work Cells.
Four Learning Objectives Understand Smoke Control Theory Understand Design Methods Know Your Role in Commissioning Tests Be Familiar with Hardware, Test.
16-Port 10/100Mbps Desktop Fast Ethernet Switch FSD-1604.
Elevators & Fire Alarm Systems: Understanding Interface Requirements Presented by: Antonio Torres- North Central Regional Sales Manager.
3U ATCA Shelf October Proprietary and Confidential-
KLINGE’S NMR 262 Two Independent Systems Integrated into one Unit This Requires Special Features:  Total Redundancy of Refrigeration Components  Total.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
MIS 1.5 Hardware Overview.
Agenda Introductions Market Opportunity Overview – CoPilot Group Activity –Hands-on installation –Demo of live system Group Discussion
TR20 Series Wireless Training Slides New Product Introduction March 2009.
Wireless TL70 70 mm Wireless Modular Tower Light
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
ONYX Product Overview.
10/100/1000Base-T to Dual 1000Base-X SFP Media Converter GT-1205A Icon5Icon4Icon3Icon2Icon1.
Designing An Electronic Trigger Mechanism For A Paintball Marker To Allow User Selectable Firing Rates ECE 4884/4007 Fall 2007 Nathan Densmore Matthew.
Addressable Fire Alarms
1 INTRUSION ALARM TECHNOLOGY KEYPADS (CONTROL UNITS)
June 2008 R&D Center / BCS HW Team Introduction to iPECS P5 Hardware.
SSD Operations Manual March 2014 SSD: 4 th layer of vertex detector Heavy Flavor Tracker Silicon Strip Detector – Operations Manual PXL Inserted from this.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
1 Fluke DAQ Software Visual Demo Guide 2680A-APSW.
AC031S/32S safety monitor: New functionality SAFETY AT WORK Date: 5/18/2009.
XS26-2 Expandable Safety Controller.
TL70 The Choice is Yours: You choose how to order and build the TL70 with the flexibility to customize the tower light as needed and change positions in.
NFS System Components & Installation.
Canadian Museum of Human Rights Winnipeg, Background The Canadian Museum for Human Rights is envisioned to be a national and international destination,
RCX ROOM COMBINING SYSTEM Allows users to combine independent audio systems into various configurations: Remain independent Multiple groups Combined as.
Wireless TL70 Sure Cross ® Wireless TL70 Tower Lights combine the best of Banner’s popular Tower Light family with the reliable, field-proven, Sure Cross.
Wireless TL70 Sure Cross ® Wireless TL70 Tower Lights combine the best of Banner’s popular Tower Light family with the reliable, field-proven, Sure Cross.
IT-100 Integration Module. IT Overview The IT-100 features a bi-directional RS-232 interface that accepts commands and sends event-driven or state-
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
Hotel Room Intelligent System applications SMART-HDL.
BOARD FEATURES  One/Double sided RED-GREEN board  Red player “OFF” – green player “ON”  Signals extra time in color of choise 
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
Pressure Governor System Electronics. 2 Sentry Pressure Governor System Description The Sentry Pressure Governor System (SPGS) is a J1939 CAN based pressure.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
LAUNCH X improvements. LAUNCH ©Auto Testing Division Content Sensor headProgrammeTarget dataClampsCabinetTurn table, Side slip.
The New Switch can replace all the Old Room Needed Controllers 1– Light Switches and Wall Dimmers 2– Air-conditioning Thermostat 3– Volume Control 4–
KNX Push-button Pro Confidential Property of Schneider Electric |
Managing HP Enterprise Virtual Array
A22N Series Pushbutton Switches/Indicators
2012 BEST Robotics Design Competition: ‘Warp XX’
Wireless 3 Buttons Touch Panel
QuickScan™ I QD2400 May 2013.
Analog Room Command Module
IP-AK2 Access Control Solution
ListenIR Sales Training
Telephone Entry and Digital Dial Systems
A22N Series Pushbutton Switches/Indicators
TR20 Series Wireless Training Slides
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

16 LED/Switch and HOA Modules 4100U Module Enhancements 16 LED/Switch and HOA Modules

New 4100U LED Switch Modules New Products Overview 4100-1300 16 LED/16 Switch Module Primary Application is Triple Channel Audio Control Provides Paging and Alert Channel Selection by Floor/Zone Provides additional features over existing 4100-1278 LED Switch Module Provides label space per LED/Switch LEDs are pluggable for color selection based upon local AHJ requirements 4100-1301 & 1302 Fan & HOA Module Primary application is fan and smoke control for Canada Replaces standard 4100U HOA modules where a red LED was not acceptable for control function status indication

4100-1300 16 LED/16 Switch More flexibility to meet local codes or project specifications Some jurisdictions require label next to each switch/LED function Paper Insert allows custom point labels Existing 4100-1278 LED Switch Module does not have label space per switch/LED LEDs are socketed to allow for custom color configurations Kits of 8 LEDs 4100-9843 Yellow 4100-9844 Green 4100-9845 Red Functionally and schematically the same as existing 4100-1278 LED/Switch modules Programming same as existing 4100-1278

16 LED/16 Switch Module Features 4100-1300 Key Features Alternating Red/Yellow Socketed LEDs One Status LED per Switch 4100U Panel Mounted 2” Module All Pluggable LEDs Custom header label area per module (top) Custom label area per LED/Switch Pair 4100-1294 LED/Switch Module Slide-in Labels, order one per cabinet Available as both Factory Built for new panels and as finished goods for aftermarket module installation Agency Listings UL ULC CSFM

16 LED/16 Switch Target Markets Primarily used in multi-channel (2-3 channel) audio control applications Targeted to meet Canadian annunciation requirements Paper label area per LED/Switch Can be programmed for other life safety control functions Socketed LEDs allow for different color combinations The LED/Switch Module provide an easy cost effective solution Replaces expensive custom annunicators Mounts internal to 4100U panel eliminating the need for additional custom cabinets Reduce product and installation costs increasing competitiveness in projects requiring multi channel audio controls by floor or zone

HOA LED/Switch Module Overview 4100U smoke control HOA (Hand-Off-Auto) LED/Switch Module is a 24 Switch/ 24 LED (Green/Yellow/Green) 4100-1301 With UNLABELED Switches 4100-1302 WITH LABELED Switches “ON” “OFF” and “AUTO” Replaces 4100-1278 & 4100-1295 module Yellow LED replaces a red LED Some AHJs and specifically Canada will not allow red LEDs for control function status The HOA LED/Switch Module provides annunciation and control at the operator interface Raised momentary switches provide tactile feedback Alternate switch action provides on/off functions High Intensity Green/Yellow/Green LEDs provide clear status annunciation Slide-in labels provide custom on-site labeling 4100-1302 shown above

4100-1301 & 4100-1302 HOA LED/Switch Module 8 Fan Controls in a double slot module Requires 4” of front panel bay space Each control consist of 3 switches and 3 LEDs Switches allow for status selection (On, Off, Auto) LEDs and switches can be custom defined for other fan or damper control functions One status LED per Switch On/Hands On: GREEN OFF/Hands Off: YELLOW Auto Control: GREEN Available as both Factory Built for new panels and as finished goods for aftermarket module installation Agency Listings UL ULC CSFM

HOA LED/Switch Target Markets Primarily used in large building requiring HVAC override control…smoke control Targeted to meet Canadian annunciation color code requirements Existing HOA module used a Red Led for manual off function New module use yellow LED for Off function Can also be programmed for damper status indication Open - trouble – closed Can be programmed for floor or stair well pressurization Exhaust –trouble- pressurized The HOA LED/Switch Modules provide an easy cost effective solution Replaces expensive custom annunicators/smoke control panels Mounts internal to 4100U panel eliminating the need for additional custom cabinets Reduce product and installation costs increasing competitiveness in projects requiring smoke control or HVAC control functions