RJ Mann Catalytic Monitoring Systems. RJMCMS 100 Low Cost Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure.

Slides:



Advertisements
Similar presentations
Titan EP Training For Programming a New Titan EP August 11, 2009.
Advertisements

Titan EP Training For Modifying a Preprogrammed Titan EP August 11, 2009.
Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Yokogawa Network Solutions Presents:
Multi-Function control Panel (MFP) AKCmed. service menu parameters setting Control panel MENU selection ( click on the selected MENU option) main menu.
Gen RGen SGen T 4p +1 Power socket 40A for Gen POWER ALARM ON OFF ENT/EX High Temp DC pri Alarm DC sec Alarm Rectifier Fail Battery Disch Air/Cond Fail.
Welcome to the Radionet Monitoring Secure-Com Presentation.
MX250 Power on and off, Console Mode. January 2004 Page 2 Power Supply MX250 has ac and dc inputs –ac 100 to 240 V, 5A, 50 to 60 Hz –dc –48 V, 6A –worldwide.
Direct Line Supply ArchWeigh HP Belt Scale Internal Speed Sensor The Most Technologically Advanced In-Motion Scale. Click to Advance.
MEGATRON. Privately owned shares company founded at The company is engaged in manufacturing Measu- rement, Monitoring and Control equipment. Megatron's.
When the Easy Fridge/Freezer Alarm is plugged into the wall it will ‘boot up’ and display the System Setup Menu Parameter menu will appear where you will.
PC Encryption installation progress/password screen Includes comments from: Encryption team Sarah Deane Tony Stieber Selected people who took part in the.
Operating Functions.
MUR-System Next We want with this PowerPoint show how easy it is to install the MUR-Systems hardware. You can try the full version of the software from.
MCS LWC MAGNUM ORIGINAL CONCEPTS  Designed to Control Loop Systems  Build to be generic and handle many configurations of Loop Controllers  Type of.
CommentaryVideo Hi, my name is Edward Guillergan and I’m one of AMETEK Programmable Power’s Applications Engineers. I’m here to provide an overview of.
ModCon® 75 Controller.
Keypad / Display Keypad/Display Mounting 6 wire shielded cable 10’ length 3 twisted pairs Keypad Three function keys Four directions.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
What is Arduino?  Arduino is a ATMEL 168 micro-controller kit designed specially for small projects  User friendly IDE(Integrated Development Environment)
Total HVAC Control from anywhere Easy control that can save a fortune
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
In this presentation you will:
A New Technology Transmitter Real Time ScadaLynx Model
Remote Monitoring and Management Solutions ®
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
Automated Pool Maintenance System Jonathan Arbogast Janine Garnham Ajay Suthar.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
G3 Electronics Platform Overview Presentation. G3 Electronics Platform Pneumatic Valve Side 32 Solenoid Output Capability Including Valve side Sub-D.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
AccuMax Multi-Point Injection Mechanics
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
SCADA and Telemetry Presented By:.
FG Wilson Access 4000 Control Panel
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
RPTCS Automatic Transfer Control System Low and Medium Voltage Power Transfer Control.
Module 1: Introduction to PLC
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Home Guard Security System. Introduction & Basic Ideas Home Guard Security System.
INDEX WELCOME DISPLAY DEFAULT DISPLAY MAIN DISPLAY SYSTEM LAYOUT – P105 to P104 SYSTEM LAYOUT – P109 to P106 ROOMS P-109 to P-104 DISPLAY CHANGE SET POINTS.
Electro Eye-Hye System II
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
DataMaster 3000 Data Acquisition and Control Software.
Water. What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured application software.
CUE – Make Any Pump an E-Pump
Our Controllers MegaTron MegaTron Multiple System Capability Multiple System Capability Internet Communication Internet Communication Conductivity.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Service Section Technical Training December 2005.
Overview of NMEA To view the devices on the NMEA 2000 network you need to press menu twice.
World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Autoflame Training,
1. 2 INDEX MAIN DISPLAYS3-4 SYSTEM LAYOUT 5-6 ROOM P-109 DISPLAY7 ROOM P-108 DISPLAY8 ROOM P-107 DISPLAY 9 ROOM P-106 DISPLAY 10 ROOM P-105 DISPLAY 11.
Water Horner APG, LLC June 4, What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Saunders® I-VUE The Intelligent Valve Sensor – Interactive Guide Key Features and Benefits Programming the Saunders® I-VUE Alarm Code Definitions How to.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Intellisys System Manager Intellisys Energy Optimizer
Quick Start Guide for Flex Flow Pump
LONER MOBILE.
LONER MOBILE.
LDA Large Display for Analog Inputs
Digital Chart Recorder Operation
724 Temperature Calibrator
System 57 Gas Control System
Presentation transcript:

RJ Mann Catalytic Monitoring Systems

RJMCMS 100 Low Cost Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure Across the Catalyst, O2 Voltage and Run-Time 30 Day Data Logging, Easy Data Retrieval and Data Transmission 16” X 16” X 10” NEMA 4 Enclosure, MODBUS Input/Outputs, Digital Input/Outputs, Optional Thermocouple Inputs and 24 VDC 2 Line Monochrome Scrolling LCD Display

RJMCMS 200 Configurable Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure Across Catalyst, O2 Voltage and Run Time 90 Day Data Logging, Easy Data Retrieval and Data Transmission 16” X 16” X 10” NEMA 4 Enclosure, MODBUS Input/Outputs, Analog Inputs, Digital Input/Outputs, Thermocouple Inputs, 24VDC with optional AC 6” Red Lion Color Display Password Protected Alarm and Shutdown Options PLC Designed to Track and Display Trend Data Built in 9 Set Point AFR Option Available

RJMCMS 300M Multiple Engine Monitoring System Capable Of Monitoring Six Units Off Of One System Monitors Pre and Post Catalyst Temperatures, Differential Pressure Across Catalyst, O2 Voltage and Run Time Data Logging Capabilities Vary, Easy Data Retrieval and Data Transmission 16” X 16” X 10” NEMA 4 Enclosure, MODBUS Input/Outputs, Analog Inputs, Digital Input/Outputs, Thermocouple Inputs and 24 VDC with Optional AC 6” Red Lion Color Display Password Protected Alarm Options PLC Designed to Track and Display Trend Data

CMS 200 Home Screen Unit 1 – Takes you to the Main Screen PLC I/O & Com Ports – This is used for trouble shooting and adjusting Modbus addresses Alarms – Used to view current alarms Reset PLC – Resets the CMS to factory conditions Alarm Present – Will light up if there is an alarm present

CMS 300M Home Screen Toggle Between Units With Ease

RJMCMS 300M

PLC I/O & Com Ports Screen These Are The Three Buttons Used For Troubleshooting

Communication Port Screens Used To Adjust For Different Modbus Addresses For External Components

Alarms Screen Alarms Will Automatically Clear When Problem Is Resolved

Main Screen DP Over Base Line (in w/c) Raw DP in (in w/c) Delta Temperature Pre-Catalyst Temperature Post-Catalyst Temperature Run Status Pre-Temperature Low DP Read Status Run Hours

Definitions DP Over Base Line - This is measured in inches of w/c and is the difference between your pre-defined baseline and your raw DP across the catalyst Raw DP – Also measured in inches of w/c and is your actual/current DP across the catalyst Delta Temperature – Difference between your Pre and Post Temperatures Run Status – Must connect to a dry contact Has a 30 minute timer to reach minimum temperature Pre-Temperature Low - This point is set in the Set Point Screen This temp must be met within 30 minutes or the light will turn red and an alarm will be triggered Data Logging readings will also show an error message

Definitions (cont.) DP Read Status – This light indicates that the CMS is communicating with the DP Transmitter Run Hours – Timer starts when there is a run signal This is not dependent on whether the unit has reached operating temperature Cannot currently set through the display but will be able to with next software revision Date and Time – Currently must be set through the program but will also be able to do so from the display with the next software revision

Display Quick View Buttons Main ScreenPressure Trends Screen

Display Quick View Buttons Temperature Trend Screen Set Point Screen

Alarm Set Points Screen DP Unbiased DP Biased Post-Catalyst O2 Pre-Catalyst Temperature Post-Catalyst Temperature Set Unit DP Base Push Set Points

Definitions DP Unbiased – This is your raw DP DP Biased – This is your DP over your baseline Post O2 Voltage - Voltage off of the O2 sensor Can be Pre or Post O2 but will only read one or the other Pre and Post Catalyst Temperatures – Taken from either the AFR or installed thermocouple conditioners Set Unit DP Base – This function will set your DP to what the current DP is across the catalyst Push Set Points – This function is used to push your set points to the PLC once you have made one or more set point changes

Adjusting a Set Point Select Which Point You Would Like To Adjust

Adjusting a Set Point Type In The Value Of The Change Then Press Enter Enter Exit

Adjusting a Set Point Press Enter

Adjusting a Set Point

Press Push Set Points Once You Have Made All Of Your Changes Press “Push Set Points ”