Irradiator Specification Installation Qualification (IQ) + Software validation Operational Qualification (OQ) Performance Qualification (PQ) Demonstrate.

Slides:



Advertisements
Similar presentations
PROCESSOR QA.
Advertisements

1 Interstate Pipeline Gas Quality Primer Business Practices Subcommittee June 15-16, 2004 PIPELINE SEGMENT Wholesale Gas Quadrant North American Energy.
ASME Y14.5 presentation by Alex Krulikowski May 2005
Demand Resource Operable Capacity Analysis – Assumptions for FCA 5.
World Health Organization
X-Ray Sterilization – Managing Risks Dr. Joern Meissner Meissner Consulting GmbH.
Validation & Sample Size Selection
1 The Short Story on Long Cycles Why the length of your steam sterilization cycle may effect your sterility assurance.
Beckett Energy Systems
VALIDATION – ARE WE DOING ENOUGH David McNamara Manager – CSSD Holy Spirit Northside Private Hospital SRACA (NSW) Conference 10 th November 2011.
Simplified VO M&V Protocols Approved May 4 th, Simplified VO M&V Protocol can be applied to distribution systems with Residential and Small Commercial.
Key Concepts in Evaluating Overall System Uncertainty Carroll S. Brickenkamp NVLAP Program Manager Panasonic Users Meeting June 2001.
World Health Organization
PPAP Requirements Training
EQUIPMENT VALIDATION.
Experience, Expertise and a Commitment to Excellence™
A Seminar on 1.  Validation vs Qualification  Why to validate?  Who should do Equipment Validation?  Parts of Equipment Validation  Validation of.
Evaluation of the characteristics of TLD LiF:Mg.Ti-100 Powder: A Measure of Consistency Between Multiple Batches of Powder Paola Alvarez,Jose Francisco.
ETHYLENE OXIDE STERILIZATION VALIDATION
SAE AS9100 Quality Systems - Aerospace Model for Quality Assurance
MEDICAL DEVICE STERILIZATION
Lic. Pedro Antonio Pérez.  To develop a simple and versatile dosimetric method capable of determining changes in matter (Xylenol Orange added Fricke.
A seminar On Validation Of Ampoule Filling & Sealing Machine
Optical Fibre Dosimetry First Thoughts. Goal Target Measuring dose in a distributed way using optical fibres (“active”) Constraints: – Mixed-Radiation.
Unit IV Analyzing the Image. Unit IV Analyzing the Image.
Water | Slide 1 of 16 January 2006 Water for Pharmaceutical Use Part 4: Commissioning, Qualification and validation Supplementary Training Modules on Good.
Validation SAPRAA March 2013.
World Health Organization
WHO Supplementary Training Modules GMP
Qualification of HVAC systems
EQUIPMENT QUALIFICATION/VALIDATION
Quality Control Rad T 110.
QUALITY MANAGEMENT SYSTEM ACCORDING TO ISO
Basic Principles of GMP
Rocky Mountain RAPS Process Validation Presentation 6/7/06 By Clay Anselmo.
1 Manufacturing Processes and Validation for Next Generation Implants.
VALIDATION METHODOLOGY
Water | Slide 1 of Water for Pharmaceutical Use Part 3: Operational considerations Supplementary Training Modules on Good Manufacturing Practice.
MAINTAINING PROCESS EFFECTIVENESS DEMONSTRATION OF CONTINUOUS EFFECTIVENESSRECALIBRATIONMAINTENANCEREQUALIFICATIONCHANGES AND RISK ASSESSMENT.
Liam Newcombe BCS Data Centre Specialist Group Secretary Energy Efficient Data Centres.
World Health Organization
Module 1, Part 3: Process validation Slide 1 of 22 © WHO – EDM – 12/2001 Validation Part 3: Process validation Supplementary Training Modules on Good Manufacturing.
Radiation Processing Irradiation consists in exposing a product to ionizing radiation in order to preserve, modify or improve its characteristics. The.
Good management Processing record Qualified and experienced operators Quality Manual  A Radiation processing facility should have the following vital.
A NON LINEAR TRANSPORT LINE FOR THE OPTIMIZATION OF F18 PRODUCTION BY THE TOP LINAC INJECTOR C. Ronsivalle, L. Picardi, C. Cianfarani, G. Messina, G.L.
Radiation Test Facilities G. Spiezia. Engineering Department ENEN Radiation tests facilities  Radiation test in the accelerator sector  External facilities.
NSTX-U NSTX-U PAC-31 Response to Questions – Day 1 Summary of Answers Q: Maximum pulse length at 1MA, 0.75T, 1 st year parameters? –A1: Full 5 seconds.
Xoft Routine Per Article Manufacturing Testing of the Axxent ® Source S. Axelrod, T.W. Rusch, M. Powell; Xoft, Inc., Fremont, CA  Purpose: To select sources.
Validation | Slide 1 of 27 August 2006 Validation Supplementary Training Modules on Good Manufacturing Practice WHO Technical Report Series, No. 937, 2006.
Network design Topic 6 Testing and documentation.
Module 4Slide 1 of 23 WHO - EDM Validation Basic Principles of GMP.
Ircon ® ScanIR ® 3 Linescanner How to deal with sectors/zones? Rev. A 07/2013.
RICH MEETING - CERN - April 21 st 2004 Università degli Studi di Milano Bicocca Variation of Refractive Index inside an Aerogel Block Davide Perego.
Upgrade PO M. Tyndel, MIWG Review plans p1 Nov 1 st, CERN Module integration Review – Decision process  Information will be gathered for each concept.
1 OBJ 2 Internal and External Exposure Control RPT
Wet Packs: Strategies for Prevention and Resolution
UnionPay Card Manufacturer Certification Introduction.
1 Copyright © 2016, The Green Grid The webcast will begin shortly Today’s live session will be recorded.
E-beam and X-ray Technologies: innovative solutions
Introduction for the Implementation of Software Configuration Management I thought I knew it all !
World Health Organization
UNILAC requirements for BIOPHYSICS research
Author: Nurul Azyyati Sabri
Water for Pharmaceutical Use
Hongyu Bai LCLS-II 2 K Cold Box FDR March 9, 2017
How to deal with Sectors/Zones?
Lecture 6: Drop & Cushion Testing presented by David Shires
ולידציה מול כיול-השונה והדומה
Commissioning is no longer what it used to be: Installation and Operational Qualification (IQ/OQ) for an Electron Beam Plant Florent KUNTZ1, Benoît MULLIER2,
יוסי שדמתי רק איכות מניהול סיכונים לאימות ותיקוף תהליכי הרכבה From Risk Management to Processes Validation יוסי.
Presentation transcript:

Irradiator Specification Installation Qualification (IQ) + Software validation Operational Qualification (OQ) Performance Qualification (PQ) Demonstrate irradiator specifications are met (installation in accordance with agreed upon specifications between vendor and operator of the irradiator) Gamma No dosimetry Examples: sources installed, Source rack moves properly, conveyance E-beam Characterisation of beam Characterize dose delivery of the Irradiator under baseline conditions: Dose magnitude, distribution and reproducibility Gamma 1)Fully loaded irradiator with single density 2)Mixed densities in the irradiator 3)Incomplete load configurations 4)Process interruptions E-beam 1)Surface dose profile 2)Dose distribution (3 dimensions) 3)Dose versus process parameters 4)Process interruptions Establish process for irradiation of product within predescribed limits Process specification

Installation Qualification of electron beam irradiator Characterisation of the electron beam  Position and shape of the beam spot (ensure product surface is covered) Position and shape of the beam spot  Electron energy Electron energy  Scan width and uniformity Scan width and uniformity  Beam current Involve dosimetry Methods in ISO/ASTM Note: beam profile needs to be characterised at multiple distances from the conveyor

electrons EXAMPLE: Beam width characterisation; Setpoint 60 cm 77 cm 59 cm 32 cm Mark with pen at distance 25 cm (so peak not related to dose delivery)

electrons 77 cm 32 cm EXAMPLE: Beam spot characterisation Mark with pen (so peak not related to dose delivery)

EXAMPLE E-Beam energy measurement electrons Based on descending slope energy can be calculated (ASTM51649) Al

Operational Qualification of Gamma irradiator 1)“Standard operating conditions” i.e. Irradiator filled to design capacity with a single product density 2) “At or beyond Standard operating conditions” of the irradiator  At least 2 different runs, each with a different density (“low” and “high”)  At least 3 irradiation containers in each run  3-dimensional dosimeter grid DUR as function of density (compare with specification) Min and Max dose zone identified as function of density Dose distribution study Dose magnitude study (scalability with timer setting) Variability of dose delivery Impact of density mixing on Dose magnitude and distribution Incompletely filled irradiation containers Process interruptions Compare results With those of 1) Dose rate as function of density (throughput, compare with specification) In the same run or even in the same irradiation container

Transition Dose Map:  Low density (or empty) followed by high density loads  1st and last dose map  Compare to homogeneous map Partial Load Map:  May use compensating dummy to center load product  Map at maximum dose locations and compare to fully loaded adjacent containers. Transition Dose Map:  Low density (or empty) followed by high density loads  1st and last dose map  Compare to homogeneous map Partial Load Map:  May use compensating dummy to center load product  Map at maximum dose locations and compare to fully loaded adjacent containers. Low density (or empty as worst case) followed by high density Dose map at least their interfase

Partially filled irradiation container Dose map their interfase

Process interruption  Cycle source between fully up and fully down (multiple times)  Single material  Irradiation container adjacent to the source plane  Response of dosimeter might be influenced by fractionated exposure

Operational Qualification of electron beam irradiator 1)“Standard operating conditions” i.e. Irradiator filled to design capacity with a single product density 2) “At or beyond Standard operating conditions” of the irradiator  At least 1 run  At least 3 irradiation containers in each run  3-dimensional dosimeter grid DUR (as function of density) Min and Max dose zone identified as function of density Dose distribution study Dose magnitude study (scalability with process parameters) Variability of dose delivery Surface dose mapDemonstrate whole surface is effectively irradiated Process interruption study All scenarios for interruption need to be included in the test program For all pathways (single – double sided exposure, different beam energy) Edge effectsEdge effectsProduct irradiated as a single entity

EXAMPLE: Dose versus process parameters at an electron beam facility

EXAMPLE: Dose distribution in reference product (double sided exposure) 40cm high 0.15 g/cc stack of homogeneous material 10 MeV electron beam

EXAMPLE: Dose distribution in reference product (single sided exposure) 0.15 g/cc stack of homogeneous material 10 MeV electron beam

Process interruption study  Location closest to the scanhorn  1-dimensional dosimeter strip in direction of product conveyance  Response of dosimeter might be influenced by fractionated exposure  Test all possible sources of interruptions e.g. Accelerator, conveyor, safety, electrical  Parameters at the extremes of operating conditions EXAMPLE: Accelerator interruption at maximum of conveyor speed

Performance Qualification, GOAL Determining dose delivery characteristics to product in a defined load configuration and for a specified process flow  Minimum and maximum dose zone determined  Variation of dose delivery characterized  Process capability for meeting specified dose range is assessed  Process monitoring practice established Acceptance criteria

Select a Product Load Configuration and a Process Flow Select a Performance Qualification dosimeter grid Product Dose Requirements Irradiator Operational Qualification Processing Efficiency Operational Qualification Dose Distribution Characteristics Additional Locations to Account for Product Heterogeneity Product Load Configuration / Orientation (partial fill of irradiation container) Consider Routine Monitoring Practices Performance Qualification, METHOD Write protocol and get it approved by all parties Execute Analyse data Write report and get it approved by all parties

Process specification includes  Description of packaged product (dimensions, weight, orientation in shipper) and acceptable variations  Loading pattern in the irradiation container  Conveyor path, process flow including lead / trail product if required  Setpoints and tolerances on irradiator parameters  Dose range of the product  Temperature restrictions  Restrictions on time between end of manufacturing and completion of irradiaiton  Process monitoring position, frequency and acceptance criteria  Any required re-orientation for multiple exposure

Questions: -Do you have a signed record on file stating all the characteristics of the irradiator? -Have you during IQ / OQ verified characteristics of the irradiator as they are mentioned in that signed record with specifications? -Did PQ cover all scenarios of processing the product (partially filled cartons, partially filled irradiation containers,...) ? -Is the outcome of PQ detailed in a process specification? Is it sufficiently detailed and signed by contract irradiator and product manufacturer?

References: -IAEA Guidelines for development, validation and routine control of industrial radiation processes -ASTM 51649:2005 Practice for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV -ASTM 2303:2003 Standard guide for absorbed dose mapping in radiation processing facilities -AAMI TIR 29:2012 Guide for process characterization and control in radiation sterilization of medical devices - ISO series