R. Kumar 1, K. Tokmakov 2, A. V. Cumming 1, G. D. Hammond 1, J. Hough 1, S. Rowan 1 1 SUPA, University of Glasgow, Glasgow, G12 8QQ, UK, 2 SUPA, University.

Slides:



Advertisements
Similar presentations
Gravitational Wave Astronomy Dr. Giles Hammond Institute for Gravitational Research SUPA, University of Glasgow Universität Jena, August 2010.
Advertisements

Overview of the Advanced LIGO Upgrade Giles Hammond, SUPA, University of Glasgow on behalf of the LIGO Scientific Collaboration and the Virgo Collaboration.
2 mm diameter region 300 micron thermoelastic noise cancellation section Neck region, for transition from 2 mm stock to 300  m fibre 150  m section for.
Gravitational Wave Astronomy Dr. Giles Hammond Institute for Gravitational Research SUPA, University of Glasgow Universität Jena, August 2010.
Cantley, Cagnoli, Crooks, Cumming, Heptonstall, Jones, Martin, Rowan, Hough Development of a CO 2 laser machine for pulling and welding of silica fibres.
1 Test Mass Suspensions for AIGO Ben Lee The University of Western Australia.
Aspects of Fused Silica Suspensions in Advanced Detectors Geppo Cagnoli University of Texas at Brownsville and TSC LIGO, Hanford.
Silicate bonding on silicon and silica S. Reid, J. Hough, I. Martin, P. Murray, S. Rowan, J. Scott, M.v. Veggel University of Glasgow.
Silica Research in Glasgow Gianpietro Cagnoli – IGR - University of Glasgow GEO Collaboration Ginzton Lab, Stanford Caltech.
Fused Silica Research for Advanced LIGO Alexander Ageev, Gregg Harry, Jim Hough, Steve Penn, Sheila Rowan, Phil Willems.
Nawrodt 05/2010 Thermal noise in the monolithic final stage Ronny Nawrodt Matt Abernathy, Nicola Beveridge, Alan Cumming, Liam Cunningham, Giles Hammond,
Development of a CO 2 laser machine for pulling and welding of silica fibres and ribbons D. Crooks for the GEO 600 collaboration Aspen January 2005 LIGO-G Z.
LIGO-G D 1 25-May-02 Advanced LIGO Suspension Model in Mathematica Gravitational Wave Advanced Detector Workshop Elba - May 2002 Mark Barton.
Charge Mitigation Studies Stuart Reid, I. Martin, A. Cumming, W. Cunningham, J. Hough, P. Murray, S. Rowan. Glasgow M. Fejer, A. Markosyan, R. Route Stanford.
September 8, 2015 THE MONOLITHIC SUSPENSION STATUS FOR THE VIRGO INTERFEROMETER THE MONOLITHIC SUSPENSION STATUS FOR THE VIRGO INTERFEROMETER Helios Vocca.
EMDM Monolithic suspension development Activity plan Piero Rapagnani Detector meeting
Substrate mechanical loss studies Sheila Rowan (Stanford University) for: LIGO Laboratory (Caltech, MIT, LLO, LHO) LSC Partners (University of Glasgow,
Low noise Fused Silica suspensions: from the GEO600 experience to the 2 nd generation requirements Geppo Cagnoli INFN Sez. Firenze University of Glasgow.
Advanced LIGO: our future in gravitational astronomy K.A. Strain for the LIGO Science Collaboration NAM 2008 LIGO-G K.
STREGA WP1/M1 mirror substrates GEO LIGO ISA Scientific motivation: Mechanical dissipation from dielectric mirror coatings is predicted to be a significant.
SUSPENSION DESIGN FOR ADVANCED LIGO: Update on GEO Activities Norna A Robertson University of Glasgow for the GEO 600 suspension team LSC Meeting, Louisiana,
Conceptual Design for Advanced LIGO Suspensions Norna A Robertson University of Glasgow and Stanford University for the GEO suspension team +contribution.
Update on Advanced LIGO suspension design and technology development towards the quad noise prototype Caroline A. Cantley for Advanced LIGO Suspension.
The investigation of thermal and non- thermal noises in fused silica fibers for Advanced LIGO suspension Moscow State University Bilenko I.A. Lyaskovskaya.
T1 task- update Mike Plissi. 2 Motivation  Thermo-elastic noise is higher than the ‘intrinsic’ noise in crystalline materials  There are several sources.
Advanced LIGO Suspension Status Caroline A. Cantley Advanced LIGO Suspension Team / University of Glasgow for the GEO600 Group LSC Meeting, LLO March 2004.
JRA3 STREGA - Introduction Geppo Cagnoli IGR – University of Glasgow ILIAS-GW Meeting, Orsay, 5 th -6 th Nov 2004.
SUSPENSION DESIGN FOR ADVANCED LIGO: Update on GEO Activities Norna A Robertson University of Glasgow for the GEO 600 suspension team LSC Meeting, Hanford.
Simulation for KAGRA cryogenic payload: vibration via heat links and thermal noise Univ. Tokyo, D1 Takanori Sekiguchi.
Low temperature dissipation in coating materials S. Reid 1, I. Martin 1, H. Armandula 3, R. Bassiri 1, E. Chalkley 1 C. Comtet 4, M.M. Fejer 5, A. Gretarsson.
18 th - 22 nd May 2015 LIGO-G GWADW Alaska Suspension Upgrades: Discussion Points + Questions Giles Hammond (Institute for Gravitational Research,
18 th - 22 nd May 2015 LIGO-G GWADW Alaska Suspension Upgrades for Enhanced Interferometers Giles Hammond (Institute for Gravitational Research,
LIGO-G Z Thermal noise in sapphire - summary and plans Work carried out at: Stanford University University of Glasgow Caltech MIT.
LIGO-G D Fused Silica Suspensions Phil Willems LIGO/Caltech Elba GWADW Meeting May 19-26, 2002.
Cold damping of fused silica suspension violin modes V.P.Mitrofanov, K.V.Tokmakov Moscow State University G Z.
Francesco Cottone INFN & Physics Departments of Perugia, Pisa, Florence (Collaboration Work under VIRGO Project) Thermomechanical properties of silicon.
Monolithic suspension assembly procedure (DRAFT) Status 27 th May 2009 LIGO-T v2.
ILIAS - GWA N5 - Strega JRA3 General Meeting Orsay - November 5th-6th, 2004 M1 Activities.
Thermal Noise performance of advanced gravitational wave detector suspensions Alan Cumming, on behalf of the University of Glasgow Suspension Team 5 th.
State College May 2004 LIGO- Mining for IMBH Gravitational Waves Fabrizio Barone Enrico Campagna Yanbei Chen Giancarlo Cella Riccardo DeSalvo Seiji Kawamura.
Thermoelastic dissipation in inhomogeneous media: loss measurements and thermal noise in coated test masses Sheila Rowan, Marty Fejer and LSC Coating collaboration.
Thermal Noise in Thin Silicon Structures
Suspension Thermal Noise Giles Hammond (University of Glasgow) on behalf of the Strawman Red Team GWADW 2012, 18 th May 2012 LIGO-G
Advanced LIGO UK 1 LIGO-G Z Development issues for the UK Advanced LIGO project Caroline Cantley Glasgow University for the UK Advanced LIGO Team.
C1) K. Tokmakov on behalf of the Advanced LIGO Suspensions Team Monolithic suspensions of the mirrors of the Advanced LIGO gravitational-wave detector.
111 Kazuhiro Yamamoto Institute for Cosmic Ray Research, the University of Tokyo Cryogenic interferometer technologies 19 May 2014 Gravitational Wave Advanced.
Monolithic suspensions in Virgo Helios Vocca Dipartimento di Fisica & INFN di Perugia LIGO-G Z.
Proposal for baseline change from ribbons to fibres in monolithic stage Mark Barton for the IGR Monolithic Team Systems Meeting 16 April 2008 G
LIGO-G Z Silicon as a low thermal noise test mass material S. Rowan, R. Route, M.M. Fejer, R.L. Byer Stanford University P. Sneddon, D. Crooks,
Design and Testing of a Silicon Suspension A. Cumming 1, G. Hammond 1, K. Haughian 1, J. Hough 1, I. Martin 1, R. Nawrodt 2, S. Rowan 1, C. Schwarz 2,
1/16 Nawrodt, Genoa 09/2009 An overview on ET-WP2 activities in Glasgow R. Nawrodt, A. Cumming, W. Cunningham, J. Hough, I. Martin, S. Reid, S. Rowan ET-WP2.
Modelling and Testing of Cryogenic Suspensions Giles Hammond Institute for Gravitational Research SUPA University of Glasgow on behalf of the KAGRA suspensions.
Low temperature dissipation in coating materials S. Reid 1, I. Martin 1, E. Chalkley 1, H. Armandula 3, R. Bassiri 1, C. Comtet 4, M.M. Fejer 5, A. Gretarsson.
Department of Physics & Astronomy Institute for Gravitational Research Scottish Universities Physics Alliance Brownian thermal noise associated with attachments.
ALIGO Monolithic stage Giles Hammond, University of Glasgow for the Advanced LIGO Suspensions Team aLIGO/aVirgo Workshop Pisa, Italy 23 rd -24 th February.
Overview of monolithic suspension work for Advanced LIGO Mariëlle van Veggel, Mark Barton, Tim Bodiya, Alan Cumming, Liam Cunningham, Giles Hammond, Gregg.
Update on the Fused Silica Suspension for Advanced LIGO Giles Hammond, on behalf of the Suspension Team L-V Meeting, Amsterdam, 22 nd -25 th September.
Overview of the 20K configuration
New suspension study for LCGT
Pros and cons of cryogenics for Einstein Telescope and Cosmic Explorer
Cryogenic Si-Si Bond Strength Testing
Thermal noise calculations for cryogenic optics
Violin mode amplitude glitch monitor for the presence of excess noise: from GEO 600 to aLIGO Borja Sorazu, Alan Cumming, Giles Hammond, Siong Heng, Rahul.
S. Rowan, M. Fejer, E. Gustafson, R. Route, G. Zeltzer
Flat-Top Beam Profile Cavity Prototype: design and preliminary tests
Test Mass Suspensions for AIGO
Lowering Mechanical Loss in Fused Silica Optics with Annealing
Characterisation of the aLIGO monolithic suspensions
Flat-Top Beam Profile Cavity Prototype
R&D in Glasgow MATERIALS ACTIVITY AIM Silica
Presentation transcript:

R. Kumar 1, K. Tokmakov 2, A. V. Cumming 1, G. D. Hammond 1, J. Hough 1, S. Rowan 1 1 SUPA, University of Glasgow, Glasgow, G12 8QQ, UK, 2 SUPA, University of Strathclyde, Glasgow, G1 1XQ, UK. Re-optimisation of the GEO HF Monolithic Suspension References 1.H Luck, H Grote, LIGO-P v2. (2010) 2.Heptonstall et al, LIGO-P v2. (2010). 3.G. Cagnoli, P. Willems, Physical Review B 65 (2002) A. Cumming et al, Classical and Quantum Gravity 26, p (2009) 5.A. Cumming, LIGO-T v1. (2010). 6.K. Tokmakov et al, LIGO-G v1. (2009). We would like to thank STFC/Rolling Grant, the University of Glasgow and our collaborators in Germany for their support in this project. Introduction The GEO-600 detector employs a triple pendulum suspension with a quasi- monolithic lower stage to minimise suspension thermal noise. Fused silica fibres which are welded to silica ears are used to suspend the test masses. During 2010 the detector will be upgraded to GEO-HF which will focus primarily on frequencies above 500 Hz [1]. There is a small risk that during this upgrade a suspension fibre may be damaged. A robust procedure for repairing the suspensions therefore needs to be in place in order to minimise downtime of the detector. The Glasgow group has gained significant experience over the past decade in developing monolithic suspensions for both the GEO-600 detector and the Advanced LIGO project [2] and are in an excellent position to perform this work. An additional opportunity also exists to re-optimise the GEO suspension design utilising the techniques gained from Advanced LIGO. The repair scenario will utilise laser pulled fibres fabricated at University of Glasgow with a CO 2 pulling machine [2]. Fibres will be transported to the GEO site in a humidity controlled enclosure and welding will take place with a H 2 -O 2 flame (identical to the original GEO suspension). We consider this work as a security measure which will ensure the future operation of the GEO-HF detector. An initial test suspension has already been developed which cancels thermoelastic loss and has the first violin mode at approximately 1kHz. Over the next couple of months the tooling will be optimised and a further series of suspensions will be fabricated and tested in Glasgow. This work will ensure that the Glasgow team maintains the skill necessary for producing an optimised GEO-HF suspension. Tooling development for welding silica fibres Any future suspension work at GEO will utilise flame welding. This is different to the case of the Advanced LIGO suspension which incorporates laser welding. In GEO-HF laser welding cannot be used to due to lack of the necessary laser facility at the GEO site. The welding of silica fibres to the silica ears will require a new set of tooling and this work has been ongoing in Glasgow  a miniaturised version of the Advanced LIGO tooling. The new set of tools includes a fibre cutter (figure 5) to cut the fibre to length and a fibre holder with x-y-z stages (figures 5, 6). The fibre holder will be placed onto the metal frame of the suspension tooling (figure 7). A suction pipe will also be used to extract silica vapour [6] while flame welding the fibres. A metal heat shield will be placed between the ears and the silica mass. Figure 5: fibre cutter / holder having three x-y-z stages for accurate adjustment while welding Figure 7: GEO test suspension with metal masses (5.6 kg). The fibre holder is bolted in place and is set up for flame welding of silica fibres. The fibres will be fabricated using the CO 2 laser (100 W) pulling machine at Glasgow (figure 3). In the old GEO suspension flame pulled fibres were used. Laser pulled fibres are far more accurate in dimension and have a much more reproducible bending point (typically 2 mm between different fibres). The pulling speed can also be adjusted to make fibres with very short neck length (see figure 4). Fabrication of silica fibres A new fibre has been designed to take into account factors such as thermoelastic noise cancellation, location of the bending point and violin mode frequencies. Thermoelastic noise, arising from the temperature dependence of the thermal expansion coefficient, leads to a temperature gradient during bending of the fibre. Heat flow across this temperature gradient induces a noise source and is a direct consequence of the Fluctuation-Dissipation theroem. In stressed fibres there is an additional term due to the variation of the Young’s modulus with temperature [3]. In fused silica it is possible to cancel these two effects by choosing a suitable fibre geometry [4,5]. Hence tapered fibres having varying cross sections have been designed to cancel this effect. Finite element modelling (figure 1) was performed in order to estimate the energy distribution in the fibres and the mode frequencies for optimised performance and lower thermal noise. The new fibre design will be pulled from a 2 mm stock, tapering down to a 300  m diameter at the bending point for thermoelastic noise cancellation. The remainder of the fibre will be 150  m diameter to keep the fundamental violin mode above 1kHz. For example, a comparison of the mechanical loss between an original GEO flame pulled fibre and an optimised laser pulled fibre is shown in figure 2. It is clear that the optimisation reduces the thermolastic peak at 20 Hz. Mechanical loss estimation of the GEO suspension using an optimised fibre design Figure 4. A fibre fabricated for the original GEO- 600 suspension (pulled by flame from a stock with 5mm diameter) in comparison with a fibre pulled on the laser pulling machine from 2mm silica stock. The short neck provides a larger dilution factor and, therefore, lower loss. Figure 3: CO 2 laser pulling machine facility at Glasgow Figure 6. During welding, the fibre is held in position by tweezers with ceramic tips. To keep the surface of the fibre pristine the tweezers grip the fibre by the 2mm stock. The suction pipe Future Work Acknowledgements Figure 2: Plot showing the mechanical loss versus frequency estimated for an optimised fibre in comparison with the loss for an original GEO-600 fibre. The mechanical loss here is estimated for the pendulum mode of vibration. LIGO-G V1 300 micron thermoelastic noise cancellation section Neck region, for transition from 2 mm stock to 300  m fibre 2 mm diameter region 150  m section for keeping the violin mode above 1kHz. Figure 1: Finite element model of the GEO suspension. Also shown is the proposed fibre which features a varying cross section. Finite element analysis of the suspension system for GEO-HF (optimised fibre design)