Production of Insulin Reverse Phase – High Pressure Liquid Chromatography Unit (RP-HPLC) Presented by:Justin McComb Rachelle Bolton Young Chang.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

3.5 Non-Newtonian fluids Newtonian fluids are fluids which follow Newton’s law: Shear Stress Shear Rate CHE Non-Newtonian fluids.
Design of RP-HPLC 1 for Insulin Production
Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
Anion Exchanger Mike LaVallee Shane Nagle Matt Rossiter.
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
IEX Chromatography Presented by: Nikki Apostolakis Helen So Tiffany Yu CHEE450: Engineering Biology.
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
Column Chromatography. Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air.
High-Performance Liquid Chromatography HPLC, when GC won’t cut it!!!
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Core Ag Engineering Principles – Session 1
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Isothermal Reactor Design – Part 2
High Performance Liquid Chromatography High Performance Liquid Chromatography Chem. 331.
Chromatography Tomáš Mlčoch Pavel Moťka. Chromatography Described by Tswett in 1906 Described by Tswett in 1906 He separated some pigments using a tube.
High Performance Liquid Chromatography (HPLC) Jeannette Comeau CHEE April 2004.
Classifying Matter and Separating Techniques. Matter and Chemicals  Matter is anything with mass and occupies space  118 elements in the PT  Properties.
Types of Liquid Chromatography I. Ion Exchange Chromatography A. Factors influencing retention B. Suppressed ion exchange II. Partitioning Chromatography.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
High Performance Liquid Chromatography Instrumentation.
UNIT 1: EXPERIMENTAL TECHNIQUES Measurements Chromatography and Chromatograms Purity Purification and Separation.
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
INTRODUCTION TO CHROMATOGRAPY
COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5.
COLUMN CHROMATOGRAPHY
High Performance Liquid Chromatography High Performance Liquid Chromatography Presented by- MOHSIN NISAR KHAN MOHSIN NISAR KHAN.
HPLC – High Performance Liquid Chromatography
Introduction  High-performance liquid chromatography (HPLC) is a form of liquid chromatography.liquid chromatography  The main purpose is to separate.
FLOW THROUGH GRANULAR BEDS AND PACKED COLUMN
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
Best Broken into four categories
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
HPLC.
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Principles of chromatography
Chromatography.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
 Also known as scrubbing  A unit operation that involves the diffusion of the solute from the gas phase through a stagnant liquid  There is a mass.
Isothermal Reactor Design – Part 2
High-Performance Liquid Chromatography HPLC, when GC won’t cut it!!!
Chem. 133 – 5/2 Lecture.
Chem. 133 – 5/11 Lecture.
Paper Chromatography.
HPLC.
FLIPPED CLASSROOM ACTIVITY CONSTRUCTOR – USING EXISTING CONTENT
High Performance Liquid Chromatography (HPLC)
Chromatographic separation
Dnyanasadhana College, Thane. Department of Chemistry M. Sc
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Best Broken into four categories
SEPARATION TECHNIQUES
HPLC.
High Performance Liquid Chromatography
What is chromatography?
High Performance Liquid Chromatography
Asst. Prof. Dr. Hayder Mohammad Jaffal
High-Performance Liquid Chromatography
Transferring LC-UV to LC-MS.
High performance liquid chromatography (HPLC)
High-Performance Liquid Chromatography
Presentation transcript:

Production of Insulin Reverse Phase – High Pressure Liquid Chromatography Unit (RP-HPLC) Presented by:Justin McComb Rachelle Bolton Young Chang

Overview  Purpose of the Unit  Principles of RP-HPLC  Design Validation Equations  Organic Modifiers  Resin Design Options  Process Design Considerations  Cost Analysis  Final Process  Final Design

Purpose of Unit  The unit purifies native insulin by removing impurities such as: insulin ester denatured insulin partially cleaved precursor components  The second RP-HPLC used in the production of insulin is used to purify the human insulin that has been produced.

Principles of RP-HPLC  RP-HPLC is a technique by which differences in polarity of compounds can be used to separate them from a mixture into their components  Chromatography functions through mass transfer between a mobile and stationary phase Stationary phase (packing): non-polar resin Mobile phase (solvent): polar liquid  As the mobile phase passes through the column, the components within that phase will have different affinities for the stationary phase.

Principles of RP-HPLC  This will affect the elution time of each compound, and will cause the mixture to separate into its components.

Principles of RP-HPLC

Design Validation Equations  Re p = Reynolds  f p = friction factor  Q = volumetric flowrate  A = x-sectional area  ρ = density  μ = viscosity  L = column length  ΔP = pressure drop  ε = void fraction  D p = resin diameter Ergun Equation Laminar Flow Validation Pressure Drop Calculation

Summary Table of Organic Modifiers 1 poise = dyne s/cm 2 = g/cm s = 1/10 Pa s 1 p = 100 centiPoise Density(g/cm 3 Room Temperature Isopropanol Acetonitrile Ethanol

Resin Design Option #1

Resin Design Option #2

Scale Up Constant Length Constant Linear Flowrate Process Design Considerations

Cost Analysis  Capital Cost (Hamilton estimates):  20 units x $20000/unit = $400,000  Operating Costs Resin Cost: $10,000/unit Solvent Cost: Encompasses 80% of total operating cost Energy Cost:  Cold water  Pump (vs. pressure drop)

Final Process  20,000 mg of the insulin solution is dissolved in 1.5 L water, 10% 2-propanol  Column is regenerated with 0.5N NaOH, washed with water, then washed with 80% isopropyl alcohol containing 0.1% trifluoroacetic acid  Column is equilibrated with 5 column volumes of Buffer A  Insulin solution is applied at 100 cm/h flow rate  Column washed with 3 column volumes of 20% Buffer B and 80% Buffer B  Buffer B increased from 20% to 40% in 1 column volume  Native insulin eluted in a linear gradient of 40-50% buffer B in 30 column volumes  16,000 mg insulin (98% purity) generated

Final Design

Questions  ????