Agilent 6410 Triple Quad LC/MS Software

Slides:



Advertisements
Similar presentations
New Applications of GC-ICP-MS Ed McCurdy a, Glenn Woods a and Raimund Wahlen b a Agilent Technologies Ltd, Lakeside, Cheadle Royal Business Park, Stockport,
Advertisements

The 6420 Triple Quad LC/MS System
Background and Theory of Electrospray and Tandem Mass Spectrometry
David Campbell 1,, Eric Deutsch 1, Henry Lam 1, Hamid Mirzaei 1, Paola Picotti 2, Jeff Ranish 1, Ning Zhang 1, and Ruedi Aebersold 1,2,3 1.Institute for.
Protein Quantitation II: Multiple Reaction Monitoring
Performance of a Hybrid RF/DC Quadrupole-Linear Ion Trap Mass Spectrometer James W. Hager MDS SCIEX ASMS, 2002.
Using Skyline to Monitor Long- Term Performance Metrics of High-Resolution Mass Spectrometers J. Will Thompson and M. Arthur Moseley Duke Proteomics Core.
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
The Proteomics Core at Wayne State University
Micromass Quattro Ultima triple quadrupole mass spectrometric detector HPLC system (LC) Electrospray ionisation source (-ve & +ve ion) Photodiode array.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Mass Spectrometry II. Ion trap Magnetic Sector FBFB.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
Mass Spectroscopy Quantitative Chemical Analysis Harris, 6th Edition
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
© ABB - Page 1 Solution Scenario Offshore Oil and Gas Reducing the cost of communicating with remote sites.
Evaluated Reference MS/MS Spectra Libraries Current and Future NIST Programs.
Agilent 7500 ICP-MS Date: 28JUL2005.
Types of Chromatography Liquid chromatography versus gas chromatography? Applications? Volatile  GC Non-volatile  LC.
1 Document Production Software Assists you with composing, editing, designing, printing, and electronically publishing documents –Word processing –Desktop.
Agilent MassHunter Quantitation Analysis Software
Using Spreadsheets In Analytical Chemistry Chap 3. Using Spreadsheets in Analytical Chemistry (1) Getting started : Excel (2) The basic usage  basic usage.
Untargeted Metabolomics: Tandem LC-MSMS. Column and Flow Rate Selection Insert Barnes table for flow rates and sensitivity gain. Reverse Phase and Normal.
In Figure 3, and using the same reasoning for THC, the LOQs for cocaine (coc), MDMA, methamphetamine (meth), and amphetamine (amp) are estimated to be.
7000A GC-QQQ Applications Pesticides in Foods (3).
This eCPIC Quick Guide has been developed to assist System Administrators with creating Hierarchy Grids in eCPIC. The Hierarchy Grid functionality allows.
Click to edit Master title style Click to edit Master text styles –Second level Third level –Fourth level »Fifth level LiveSense Cloud Platform.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Temple University MASS SPECTROMETRY FURTHER INVESTIGATIONS Ilyana Mushaeva and Amber Moscato Department of Electrical and Computer Engineering Temple University.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Mass Analyzers: Quadrupole ion trap?  
Dawn The Trip of One Xenon Atom Through an Ion Engine Simplified Graphic.
Section 10.3 Percent Composition and Chemical Formulas.
Molecular Mass. Mass of Atom Measured in atomic mass unit (amu) 1 amu = 1.66 x g Defined by assigning the mass of 12 amu to the carbon-12 isotope.
© 2006 Bentley Systems, Inc. Bentley Building Solutions multidisciplinary, integrated design and analysis.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
Mass Spectrometry Quantitative Mass Spectrometry
Review for MassHunter and reporting
Unstoppable productivity; Uncompromised MS/MS simplicity Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS/MS Unstoppable productivity; Uncompromised.
Knowing 3ds Max Software. Overview Autodesk 3ds Max, formerly 3D Studio, then 3D Studio Max is a professional 3D computer graphics program It is used.
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
Introduction to Liquid Phase Mass Spectrometry
Hiden Compact SIMS Mass Spectrometry in solid material.
Temperature Dependence of Rb + (H 2 O) n and Rb + (H 2 O) n Ar (n=3-5) Cluster Ions Amy L. Nicely OSU International Symposium on Molecular Spectroscopy.
Methodology of targeted mass spectrometry
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
H M Arif Ullah, Hye Jin Chung*
Business Intelligence MSCS 6931 Compare Tableau and Power BI Haochen(Bamboo) Sun Sep 30, 2015.
Metabolomics Part 2 Mass Spectrometry
Tandem MS.
Sample Preparation Enzymatic Digestion (Trypsin) + Fractionation.
LC-MS/MS Identification of Impurities Present in Synthetic Peptide Drugs Dr Anna Meljon*, Dr Alan Thompson, Dr Osama Chahrour, and Dr John Malone Almac.
Multiple Reaction Monitoring (MRM) Selected Reaction Monitoring (SRM)
Tandem MS.
Accelerating Research in Life Sciences
HPLC Equipment : Detectors
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Using PowerPoint to Present Research Results
Agilent LC/MS Overview
Visual Vocabulary Chemistry.
Results and discussion Technical innovations
Sample Spectra 1/1/2019.
Proteomic Approaches to Cancer Biomarkers
Instrument: Agilent 6495 QQQ, acquisition software version B
NETCHEM Remote Access Laboratory Guide
Mass spectrometry (MS) is an analytical technique that can be used to determine the mass, elemental composition or chemical structure of molecules. Mass.
Presentation transcript:

Agilent 6410 Triple Quad LC/MS Software Mass Hunter QQQ Quantitative Analysis Software Sensitivity, Reliability, Value Whether you need to quantitate drug metabolites, measure herbicide levels in foods, or determine contaminant levels in ground water, the triple quadrupole mass spectrometer has proven itself to be without equal for quantitating trace organic compounds in dirty matrices. The Agilent 6410 Triple Quadrupole LC/MS establishes a new standard for value in a triple quadrupole mass spectrometer; delivering outstanding sensitivity, great ease of use, and legendary Agilent reliability: all at a very attractive price. Features Femtogram-level sensitivity - All ion-path components are designed to maximize ion generation and transmission across a broad mass range-for low limits of detection regardless of application. Fast, high-throughput MS/MS - The high-frequency hexapole collision cell uses linear acceleration to provide very fast MS/MS experiments without cross-experiment memory effects. Sensitivity remains excellent even with 5-ms dwell times. Rugged, reliable performance - Agilent's patented orthogonal spray ion source and high-capacity counter-current drying gas maximize performance across the widest range of flow rates and mobile phases, keep the ion optics cleaner, and reduce background. Ion source choices maximize versatility - The best selection of ion sources in the LC/MS industry-including the revolutionary multimode sources with true simultaneous ESI and APCI-allow the 6410 to address a wide range of applications New software increases throughput - All-new software maximizes convenience and throughput with features like automated tuning, parameterless integration, dynamically linked data, Curve-Fit Assistant, batch review, color-coded outlier flagging, and customizable reporting. Agilent Technologies MassHunter LC-MS/MS Quantitative Analysis Software

Agilent Triple (QqQ) 6410 LC/MS Sensitivity, Reliability, Value Whether you need to quantitate drug metabolites, measure herbicide levels in foods, or determine contaminant levels in ground water, the triple quadrupole mass spectrometer has proven itself to be without equal for quantitating trace organic compounds in dirty matrices. The Agilent 6410 Triple Quadrupole LC/MS establishes a new standard for value in a triple quadrupole mass spectrometer; delivering outstanding sensitivity, great ease of use, and legendary Agilent reliability: all at a very attractive price. Features Femtogram-level sensitivity - All ion-path components are designed to maximize ion generation and transmission across a broad mass range-for low limits of detection regardless of application. Fast, high-throughput MS/MS - The high-frequency hexapole collision cell uses linear acceleration to provide very fast MS/MS experiments without cross-experiment memory effects. Sensitivity remains excellent even with 5-ms dwell times. Rugged, reliable performance - Agilent's patented orthogonal spray ion source and high-capacity counter-current drying gas maximize performance across the widest range of flow rates and mobile phases, keep the ion optics cleaner, and reduce background. Ion source choices maximize versatility - The best selection of ion sources in the LC/MS industry-including the revolutionary multimode sources with true simultaneous ESI and APCI-allow the 6410 to address a wide range of applications New software increases throughput - All-new software maximizes convenience and throughput with features like automated tuning, parameterless integration, dynamically linked data, Curve-Fit Assistant, batch review, color-coded outlier flagging, and customizable reporting. MassHunter LC-MS/MS Quantitative Analysis Software

Triple Quadrupole: MRM means “SIM” Parent Ions Enter Collision Cell - Collide with Ar Gas and Dissociates Sensitivity Selectivity Detector API Source SRM on a triple quad is more sensitive than full scan MS/MS in an ion trap because both Q1 and Q3 are parked on a single m/z ion. This means are nearly 100% duty cycle because both mass analyzers are dwelling on a single ion. In the trap we must do an accumulation, which takes time and translates into a loss of sensitivity. Q3 is Parked Passing Only Product Ions of a Single m/z to the Detector Energy Q1 is Parked Allowing Only Parent Ions of a Single m/z to Pass to the Collision Cell Ion Guide Transports +/- Ions to Q1 +/- Ions and Neutrals Formed in API Source MassHunter LC-MS/MS Quantitative Analysis Software

Pipeline software subsystem architecture Acquisition Deliverables: Acquisition deliverables organized as Sequence table Analysis File versioning of method, data, results can be handled by SSI’s XDrive. Deliverables: Reporting results including graphics and calculations Reporting Deliverables: Reporting subsystem formats results and imports graphics MassHunter LC-MS/MS Quantitative Analysis Software

Agilent 6410 QQQ Quantitative Analysis Software Sensitivity, Reliability, Value Whether you need to quantitate drug metabolites, measure herbicide levels in foods, or determine contaminant levels in ground water, the triple quadrupole mass spectrometer has proven itself to be without equal for quantitating trace organic compounds in dirty matrices. The Agilent 6410 Triple Quadrupole LC/MS establishes a new standard for value in a triple quadrupole mass spectrometer; delivering outstanding sensitivity, great ease of use, and legendary Agilent reliability: all at a very attractive price. Features Femtogram-level sensitivity - All ion-path components are designed to maximize ion generation and transmission across a broad mass range-for low limits of detection regardless of application. Fast, high-throughput MS/MS - The high-frequency hexapole collision cell uses linear acceleration to provide very fast MS/MS experiments without cross-experiment memory effects. Sensitivity remains excellent even with 5-ms dwell times. Rugged, reliable performance - Agilent's patented orthogonal spray ion source and high-capacity counter-current drying gas maximize performance across the widest range of flow rates and mobile phases, keep the ion optics cleaner, and reduce background. Ion source choices maximize versatility - The best selection of ion sources in the LC/MS industry-including the revolutionary multimode sources with true simultaneous ESI and APCI-allow the 6410 to address a wide range of applications New software increases throughput - All-new software maximizes convenience and throughput with features like automated tuning, parameterless integration, dynamically linked data, Curve-Fit Assistant, batch review, color-coded outlier flagging, and customizable reporting. MassHunter LC-MS/MS Quantitative Analysis Software

MassHunter Quantitative Analysis Software Video Organization Batch-at-a-Glance 1. Powerful sample and compound data visualization capabilities Method Editor Sensitivity, Reliability, Value Whether you need to quantitate drug metabolites, measure herbicide levels in foods, or determine contaminant levels in ground water, the triple quadrupole mass spectrometer has proven itself to be without equal for quantitating trace organic compounds in dirty matrices. The Agilent 6410 Triple Quadrupole LC/MS establishes a new standard for value in a triple quadrupole mass spectrometer; delivering outstanding sensitivity, great ease of use, and legendary Agilent reliability: all at a very attractive price. Features Femtogram-level sensitivity - All ion-path components are designed to maximize ion generation and transmission across a broad mass range-for low limits of detection regardless of application. Fast, high-throughput MS/MS - The high-frequency hexapole collision cell uses linear acceleration to provide very fast MS/MS experiments without cross-experiment memory effects. Sensitivity remains excellent even with 5-ms dwell times. Rugged, reliable performance - Agilent's patented orthogonal spray ion source and high-capacity counter-current drying gas maximize performance across the widest range of flow rates and mobile phases, keep the ion optics cleaner, and reduce background. Ion source choices maximize versatility - The best selection of ion sources in the LC/MS industry-including the revolutionary multimode sources with true simultaneous ESI and APCI-allow the 6410 to address a wide range of applications New software increases throughput - All-new software maximizes convenience and throughput with features like automated tuning, parameterless integration, dynamically linked data, Curve-Fit Assistant, batch review, color-coded outlier flagging, and customizable reporting. 2. Create and edit an MRM method in a simple stepwise scenario Excel-base Reporting 3. Flexible and customizable solution based on XML-mapping MassHunter LC-MS/MS Quantitative Analysis Software

Agilent 6410 Triple Quad LC/MS Software Mass Hunter QQQ Quantitative Analysis Software The videos involve quite a bit of demos and not much slide whipping. I’ve tried to mention why we designed the software in a particular manner So that you can gain a deeper understanding – And thus put the features to work in your environment. As always, thank you for your attention. Agilent Technologies MassHunter LC-MS/MS Quantitative Analysis Software