Presented By Richard Aitken BACKFLOW PROTECTION – THE NEW ZEALAND PERSPECTIVE.

Slides:



Advertisements
Similar presentations
Final Competence Assessment Assessment Documents Assessment strategy (SummitSkills) Assessment methodology (SQA) Assessment guidelines (SQA)
Advertisements

Barhale Procedure for Site Establishment
Basic safety rules and procedures for controlling hazardous energy
City of Milwaukee Cross Connection Program Construction Trades Division Cross Connection Section.
Cross-Connections Gary Carlson Drinking Water Program U.S. EPA Region 8.
PB - Dialysis Review1 DIALYSIS MACHINES REVIEW OF PLUMBING INSTALLATION REQUIREMENTS.
Backflow Preventers. Cross Connection Direct arrangement of piping which allows the potable water supply to be connected to a line which contains a contamination.
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
California’s New Onsite Wastewater Treatment System Policy Richard Sanchez, REHS, MPH President California Conference of Directors of Environmental Health.
Backflow Training Introduction to Backflow For Irrigation Systems.
Review of Safety-Related Regulations and Standards 2-1 Chapter 2.
MassDEP, Environmental Analyst
South Carolina Finance Workshop for Small Water Systems June 4, 2013 Water Partnerships: Financial Advantages and Challenges SC Case Study: Lowcountry.
Participant Challenge Pilot Program Participant Stage One Assess, Learn and Develop.
TECHNICAL SECTION 2000 TRAINING LIQUID WASTE LAND USE SOLID WASTE BIOSOLIDS HOUSING VECTOR WATER INDIVIDUAL PUBLIC.
Backflow Prevention.
Copyright © 2004 McGraw-Hill Ryerson Limited 1 PART 8 – SPECIAL LEGAL RIGHTS AND RELATIONSHIPS  Chapter 35 – Environmental Law Prepared by Douglas H.
21 st Annual Conference. Liquid and Hazardous Waste Management in Christchurch.
The Health (Drinking Water ) Amendment Act 2007 Grading and Backflow Answers for Water Suppliers Diana Staveley AWT.
RADIATION MONITORING OF SCRAP METAL: BELARUS’ PERSPECTIVE V. PIOTUKH LEADING STATE NUCLEAR AND RADIATION SAFETY INSPECTOR PROMATOMNADZOR BELARUS Group.
Codes, Standards & Conformity Assessment GP Russ Chaney CEO, The IAPMO Group
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
A. Mancuso - HACCP and small food producing establishments – experience from Italy 1 HACCP AND SMALL FOOD PRODUCING ESTABLISHMENTS – EXPERIENCE FROM ITALY.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
Plumbing Supply Forum 2012 Carmel Coate, Executive Director PPI Group Is Good!
International Backflow Perspective Australian Backflow Association Gary Ashwood 31 July, 2015.
MINIMUM CRITERIA Project Manager Marianne Lindström, Bulgaria SYKE, Expert Services, Environmental Management Division.
Unit 201: Health and safety in building services engineering
Important informations
Code of Practice NZ Boundary.  1961 Drinking Water Regulations covered Backflow but was loose.  “At the discretion of the Engineer”  2013 Replacement.
Environmental Management System Definitions
Drinking Water + Compressed Air = Dangerous Mixture Spokane Regional Cross Connection Control Chapter Requirements for Winterizing Irrigation Systems with.
Policy and Legal Framework on Soil Contamination Management in Thailand Workshop on Strengthening Contaminated Soil Monitoring in Vietnam, November.
DEREL TEMPUS DEVELOPMENT OF ENVIRONMENTAL AND RESOURCES ENGINEERING LEARNING DEVELOPMENT OF ENVIRONMENTAL AND RESOURCES ENGINEERING LEARNING.
A PRESENTATION TO THE SELECT COMMITTEE OF PUBLIC SERVICES 13 FEBRUARY 2008 BY NOSIPO SOBEKWA CHIEF DIRECTOR: MARITIME TRANSPORT REGULATION DEPARTMENT OF.
This Project is funded by the European Union Project implemented by Human Dynamics Consortium This project is funded by the European Union Projekat finansira.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Strengths and weaknesses of the permitting system and enforcement process in RIEW – Veliko Turnovo Regional Inspectorate of Environment and Water - Veliko.
How to start with the implementation of IPPC Directive Czech Republic Czech Environmetal Inspectorate.
RATIFICATION OF THE CAPE TOWN AGREEMEMENT OF 2012 ON THE IMPLEMENTATION OF THE PROVISIONS OF THE TORREMOLLINOS PROTOCOL OF 1993 RELATING TO THE INTERNATIONAL.
Legal Aspects of GHS Implementation Compiled by Goh Choo Ta.
Plumbing Building Developing Policies and Guidelines Sydney Water Customer Contract Connections to Sydney Water Systems Policy Responsibilities of Connected.
Electricity kills and injures people. Around 1000 electrical accidents at work are reported to HSE each year and about 25 people die of their injuries.
Backflow Prevention:- Asset or Liability? OR Use air gaps at hazardous locations 1992 New Rules:- Either keep a register of all devices, and test annually.
1 DIRECTORATE-GENERAL FOR ENERGY AND TRANSPORT Digital Tachograph : Information Seminar Budapest, 25-26/02/20009 Digitac.
Mutual Recognition Signatories – An Obligation Promote the acceptance of accredited test and inspection reports in their economies (regulators, industry.
Meet your Regulator Workshop with FANR licensees October 2011 Dr. John Loy Director, Radiation Safety Federal Authority for Nuclear Regulation.
Backflow Special Interest Group Christchurch Christchurch 24 September 2008.
CROSS CONNECTION CONTROL PROGRAM
Workshop developed by RCAP/AWWA and funded by the USEPA
Start the program by pressing “enter”.
Pat Nestor MSCSI MRICS Head of Building Control Dublin City Council
Cross Connection Survey Training
Administrative Agencies
Backflow Prevention and Cross Connection Control Update
Maintaining Safety Standards
Department of Water and Environmental Regulation
Your Public Water System’s Cross-Connection Control Program
Maintaining Safety Standards
Global Connections Day Building Safety Service Provider
Managing the Sunshine Coast Council Backflow Register
Backflow Prevention Conference
Chapter 25 Employment-Related Injuries
2017 National Backflow Prevention Conference
BPAA Conference 2017 Plumbing industry outlook Focused on training
Health and Safety! By jack Hughes.
Importance of Law and Policies in the Environmental Management System
Definitions Hazard- the potential of a substance, activity or process to cause harm. They can take many forms such as chemicals, electricity or the use.
Backflow Survey Glen Burr.
CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION
Presentation transcript:

Presented By Richard Aitken BACKFLOW PROTECTION – THE NEW ZEALAND PERSPECTIVE

 Current Chair of New Zealand Backflow Group  Sitting NZ Representative on AS/NZS 2845  Project Leader for New Zealand Field Testing of Backflow Prevention Devices and Air Gap Verification Industry Standard.  Licensed Plumber  Qualified Backflow Tester  Qualified Backflow Hazard and Cross Connection Surveyor  Owner of Plumbing Company in its 17 th year, very busy undertaking earthquake repairs and remedial work. RICHARD AITKEN

 We see things differently….. THE NEW ZEALAND PERSPECTIVE

 Chemigation/Fertigation Valves  Boundary demarcations – Point of Supply  Backflow device testing industry standard  Surveying industry standard  The role of the NZ Plumber in all areas. TOPICS

 The bypassing of current NZ Acts and Legislation by Regional Authorities (ECAN in Canterbury) is of particular concern.  Single Check valves are not recognized in NZ Law after 2001, this being one of the reasons for NZ voting to not adopt the changes to AS  Single check valve failure in a high hazard situation would result in contamination of the source, a critical issue in New Zealand.  The lack of an approved testing procedure for the single check valve.  Valves are being consented illegally, by ECAN.  Lack of determination on whether aquifer draw off is governed by the Health Act or Building Act, and who is responsible for the protection of the potable water. CHEMIGATION VALVES

 Outside the Boundary – Health Act 1.Regulated by the Health Act 2.Governed by: Regional Authorities  Inside the Boundary – Building Act  Regulated by the: Local Territorial Authority (Council)  Implemented by: Local Territorial Authority (Council)  Governed by: The Department of Building and Housing, Plumbers, Gasfitters and Drainlayers Board:  Outcome: The Installing Certifying or licensed Plumber, is the sole bearer of legal responsibility. BOUNDARY DEMARCATION

 Australia changed AS/NZS – NZ voted to not adopt changes.  New Zealand then needed a Specific Industry Standard  The stakeholders in the creation of the standard: 1.New Zealand Backflow Group – Water New Zealand 2.Master Plumbers Association New Zealand  Training unit standards now align with the testing standard.  How is it working in practice, and has it been successful?  It was then Gazetted by the Department of Building and Housing under the Building Act, and included in G12 Water Supplies. FIELD TESTING OF BACKFLOW PREVENTION DEVICES AND VERIFICATION OF AIR GAPS

 The questions we asked in the project scope were:  The need for a Specific Cross Connection Surveying Industry Standard.  The different ways to implement the standard across the boundary demarcation (Health Act/Building Act).  Who can carry out Surveying?  Enforcement of the survey outcome, is the outcome mandatory enforcement?  This project has just commenced and is an exciting prospect, as it is our intention that licensed surveyors will dictate the internal and boundary protection of the potable water supply. SURVEYING INDUSTRY STANDARD

 The plumber is legally responsible for the installation of all devices on and inside the boundary (Building Act).  The plumber is legally responsible for all repairs to devices on and inside the boundary (Building Act).  The plumber is legally required to ensure that the device locations and types meet the Building Act requirements.  BUT.  There are NO mandatory cross connection surveying or hazard assessments required at the consent stage.  There is NO requirement that person who do carry out the hydraulic design are qualified to specify the hazard type or location of the devices.  NO inspection of installed devices in Christchurch (and other areas), the device test result (Tester not required to be a plumber) is used as a method of proving compliance. THE ROLE OF THE NZ PLUMBER

QUESTIONS