Wilhelm Conrad Röntgen

Slides:



Advertisements
Similar presentations
© John Parkinson 1 MAX PLANCK PHOTOELECTRIC EFFECT.
Advertisements

ELECTROMAGNETIC RADIATION
X-Rays in Medicine.
Advanced Biomedical Imaging Lecture 3
I0I0 I 0 V 0 V0V0 f f 0 1)Current depends on potential; max current I 0 (saturation) for high voltages. I 0 reached when all electrons are collected 2)Positive.
Chapter 9 The X-ray Machine
Digital Imaging with Charge- coupled devices (CCDs)
X Rays Medical Physics Notes.
Introduction to x-rays
X rays Finishing Option G. X-ray production We have seen that an accelerating charge must emit energy in the form of EM radiation. If this acceleration.
ANALYTICAL X-RAY SAFETY User Training Centre for Environmental Health, Safety and Security Management.
X-rays : Their Production Their Interaction with Matter
Line focus principle Heal effect Ratings Tube failure
X-ray tube.
X-RAY TUBE.
Electromagnetic Waves G5 - X Rays. Coolidge tube (X-ray tube) K = Hot filament cathode A = Tungsten anode U h = Heater Voltage (e.g. 12V) U a = Accelerating.
/ / X-RAY is part of the electromagnetic radiation. X-RAY has a form that similar to ordinary light rays (like infrared.
Production of X-rays (1)
Addition 1’s to 20.
Instrumental Chemistry
1 Contents: PhotonsPhotons2 Photoelectric effectPhotoelectric effect 4 Bohr AtomBohr Atom11 Line Emission SpectraLine Emission Spectra14 Types of Spectra18Spectra.
Chapter 11 Prime Factors.
I2 Medical imaging.
A Technical Seminar On X-RAY AND CT SCAN.
Electrons The discovery of the electron was a landmark
Resident Physics Lectures
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
Medical Imaging X-Rays I.
PRODUCTION OF X-RAY & X-RAY SPECTRUM
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Instrumentation Part 1.
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
Computed Tomography RAD309
Unit 1 Physics Detailed Study 3.6 Chapter 15: Medical Physics.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
5.4.1 X-Rays. (a) describe the nature of X-rays Stowmarket Physics X-rays - nature Forms of electromagnetic radiation Short wavelength High frequency.
Topic 29: Remote Sensing 29.1 Production and use of X-rays 29.2 Production and uses of ultrasound 29.3 Use of magnetic resonance as an imaging technique.
X-Ray Medical Imaging Physics – IB Objectives
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
X-ray 1. Use of X-ray a. Medical diagnosis ……………………………………….1 b. Industry …………………………………….……………….2 c. Chemistry ………………………………….……………….2 2. X-ray spectrum…………………………….…..…….6.
Chapter 2 The X-ray Beam.
X - RAYS IN DIAGNOSTICS D. Krilov
X-rays. Electromagnetic Spectrum to 10 nm 400 to 700 nm to nm 10 to 400 nm 700 to 10 4 nm X-ray radiation was discovered by Roentgen.
The electron.  An indivisible quantity of charge that orbits the nucleus of the atom.
X-rays discovered in 1895 by Wilhem Roentgen Roentgenology – Branch of medicine dealing with x-ray or gamma rays in diagnosis and treatment. Radiology.
Interaction of x-ray photons (and gamma ray photons) with matter.
Tube Exposure Factors Math Technique Contrast and Density
X-Rays Unit 5: Medical Physics. OCR Specification Learning Outcomes: Describe the nature of x-rays Describe how x-rays are produced Describe how x-rays.
Photons SACE Stage 2 Physics. Photons Consider a darkened room with the Young’s Double Slit experiment setup. The light source is releasing very low levels.
Medical Physics.
X-ray tube.
An early x-ray by Wilhem Rontgen
X-Rays were discovered in 1895 by German physicist Wilhelm Conrad Röntgen. They were called X-Rays because their nature was unknown at the time. He was.
Describe how X-rays interact with matter using the photoelectric effect, Describe the Compton effect and pair production. Define intensity and use the.
Patient is placed between X-ray tube and silver halide film.
Chapter1 & 9 History of Radiology and X-ray Tube
UNIT-IV X-RAYS.
X RAYS.
X-RAY PRODUCTION AND EXPOSURE FACTORS
X-ray Production Sharif Qatarneh Medical Physics Division
By Dr: Mohamed Afifi Lecturer Radiological Science
Part No...., Module No....Lesson No
X-Radiation.
Learning Objectives By the end this lesson you should…
X-Rays & Their Properties
Characteristic Radiation in Tungsten Targets Shell # of electrons Binding energy L Char M N O P Eff X-ray Energy K
X Rays Medical Physics Notes.
Computed Tomography (C.T)
Presentation transcript:

Wilhelm Conrad Röntgen 1895 X - RAYS JP©

X – RAYS !! ROENTGEN 1895 Induction Coil +ve -ve Cathode Ray Discharge Tube Frau Roentgen’s Hand Wrapped Photographic Plate was EXPOSED X – RAYS !! JP©

Early cold cathode X-ray tube anode 0 V 100 kV Air at low pressure JP©

Thermionic Emission of Electrons X-Ray Tube BASIC PRINCIPLE -ve high voltage +ve Anode +ve Heater current Thermionic Emission of Electrons X-Ray Photons JP©

Wavelength range : 10-9 - 10-11 metres On Average 99% of each electron’s energy is converted into heat energy. X-RAYS ARE PRODUCED IN TWO WAYS. 1. A BACKGROUND BREMSSTRAHLUNG SPECTRUM 2. A FINE LINE SPECTRUM Wavelength range : 10-9 - 10-11 metres JP©

BREMSSTRAHLUNG RADIATION SPECTRUM ACCELERATING CHARGES RADIATE ELECTROMAGNETIC RADIATION When a fast-moving electron swings around a heavily charged nucleus, its acceleration changes rapidly. + NUCLEUS BREMSSTRAHLUNG radiation Photon Energy, E = hf JP©

BREMSSTRAHLUNG BACKGROUND SPECTRUM Many X-Ray wavelengths [ down to a certain minimum ] may be produced by a particular X-Ray tube, depending upon how much of the electron’s energy is converted in this way. 0 2 4 6 8 10 λ x 10-11 m Intensity Maximum electron energy available = eV 50 kV 20 kV λmin JP©

DEPENDS UPON THE TARGET METAL IN THE ANODE FINE [ LINE ] SPECTRUM DEPENDS UPON THE TARGET METAL IN THE ANODE 50 kV 0 2 4 6 8 10 λ x 10-11 m Intensity 20 kV LINE SPECTRA JP©

LINE SPECTRUM Produced after an electron knocks out an inner electron from one of the target atoms Electrons from a higher energy level can then fall in to a vacant energy level. Excess energy is lost as an X-Ray photon NUCLEUS K L M e e e e JP©

X-RAY SPECTRUM AS A FUNCTION OF TUBE P.D. Intensity LINE SPECTRA 100 kV 150 kV Voltage / kV JP©

THE ANODE ROTATES AT 3000 RPM ROTATING ANODE X-RAY TUBE rotating anode motor stator tungsten target motor rotor vacuum 100 000V 6.3 V A.C. ball race bearings 0 V hot filament focusing cathode electron beam X-RAYS THE ANODE ROTATES AT 3000 RPM JP©

ROTATING ANODE X-RAY TUBE THE TUBE IS IMMERSED IN OIL TO ASSIST COOLING. THE ANODE IS ROTATED SO THAT IT DOES NOT MELT. X-Ray QUALITY [= penetrating power] is increased by increasing the p.d. across the tube. X-Ray INTENSITY [ number of photons per second] is increased by increasing the filament current. This is the way in which the exposure time to produce a photographic plate is controlled. JP©

ATTENUATION OF X-RAYS IN A VACUUM, OR AIR, ATTENUATION OBEYS THE INVERSE SQUARE LAW IN A MATERIAL OF THICKNESS X metres Where I = the transmitted intensity in Wm-2 , I0 = the incident intensity and μ = the linear attenuation coefficient. % transmission 100 50 x the half thickness JP©

The mass attenuation coefficient, μm, is the attenuation x the half thickness is the thickness of material that halves the X-Ray intensity The mass attenuation coefficient, μm, is the attenuation per unit mass of material.  where ρ is the density of the material JP©

X-RAY IMAGING X-rays cannot be focused. They only make shadow images. We therefore need to produce a point source. The geometry of the anode restricts the angular beam width to about 17o. The width of the beam is further limited with strips of lead. anode Lead aperture Lead cone Narrow X-Ray Beam JP©

Lead GRID absorbs scattered X-Rays X-RAY IMAGING Lead aperture Lead cone anode Lead GRID absorbs scattered X-Rays FILM JP©

evacuated glass envelope IMAGE INTENSIFIER TUBE photocathode anodes fluorescent screen B fluorescent screen A electrons X RAYS to TV camera evacuated glass envelope Screen A converts X – Rays into light Light releases photoelectrons from the photocathode Electrons accelerated by anodes The energy gained by the electrons increases the intensity produces in screen B by a factor of 100 JP©

Contrast Media Barium sulphate is used for X-rays of the digestive system. It is given as a white liquid drink (barium meal) or into the back passage (barium enema). X-rays cannot go through it, so when the X-ray pictures are taken, the outline of the stomach or bowel shows up on the X-ray. JP©

CT SCANNER X – Ray source moves around the circular tube sending X - Rays through the patient in a fan shaped beam. X –Ray detector moves around in time with the source and measures the X – Ray strength in each position. JP©

Computed Tomography Imaging (CT Scan, CAT Scan) Each time the x-ray tube and detector make a 360 degree rotation and the x-ray passes through the patient's body, the image of a thin section is acquired. During each rotation, the detector records about 1,000 images (profiles) of the expanded x-ray beam. Each profile is then reconstructed by a computer into a two-dimensional image of the section that was scanned. JP©