EPOCH 1000 Series Software Feature AWS D1.1/1.5

Slides:



Advertisements
Similar presentations
EPOCH 1000 Series Procedure Conventional Straight Beam Calibration
Advertisements

Conventional UT B-scan Software Option
EPOCH 1000 Series Procedure Conventional Angle Beam Calibration
1 Copyright © 2007 M. E. Kabay. All rights reserved. Using the TRACK CHANGES Features in MS-Word M. E. Kabay, PhD, CISSP-ISSMP CTO & Program Director,
Graham On-Line Quote System Welcome to Grahams presentation of Graham On-line.
Chapter3 Pulse-Echo Ultrasound Instrumentation
EPOCH 1000 Series Software Update New Features - March 2010.
3.60 CEREC Connect Lab Import
Working with Tables for Page Design – Lesson 41 Working with Tables for Page Design Lesson 4.
Tandberg Basic Operating Guide Classic Systems Collaborative Services Education Technology Services The School Board of Broward County, Florida.
PRESS C7000/C7000P/C6000 Color Density Control Color Balance
EPOCH 1000 Series Procedure Multi-Angle Feature. Feature Overview and Activation.
Calibration Procedure.  A winch calibration is completed via a linear interpolation between 2 points.  Requires 2 references  Known lower weight 
Creating Rout Paths Using CAMMaster. Step 1 Import Gerber File. Import Gerber File. User Ctrl+W to window around data. User Ctrl+W to window around data.
Copyright Albion Devices, Inc., Demonstration of MicroComp micro-computer gaging system from Albion Devices, Inc.
EPOCH 1000 Series Procedure Phased Array DGS/AVG
EDSM II Training. EDSM II EDSM II (Enhanced Digital Select Module) is a hand held program module used to program Atlas laundry dispensers –Recommended.
EPOCH 1000 Series Procedure Phase Array Straight Beam Calibration
Customizing Word Microsoft Office Word 2007 Illustrated Complete.
Advanced Tool Management Information Module Advanced Tool Management Information Module.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
Using ITAMS as a Supervisor or ITAMS Approver Login to ITAMS as usual, at: Enter your User Identification Number (Same as your.
EDAX Operation Operation of the Phoenix EDAX system
EPOCH 1000 File Management Data Logging and Reporting
Exceed Series Decorative Stitch Patterns The Exceed series also has a Decorative Pattern menu where intricate patterns can be selected. The Exceed Quilt.
Manual of AWA6228 II).Several Basic Setups Hangzhou Aihua Instruments Co., Ltd.
10 March Setup Users. 10 March Setup Users Window Allows you to perform several user tasks –Enroll users –Enable/disable users –Set user access.
Processing Department Time Entry Human Resources.
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
EPOCH 1000 Series Procedure Custom PA Probe-Wedge Definition.
ResponseCard XR Editing Tests and Homework ®. Navigating the Menu Press the MENU button to bring up the main menu. Press the Down Arrow twice to select.
January 2011City of Boise 1 City of Boise Time Clock Training Airport Biometrics Clocks.
Training Presentation
EPOCH 1000 Series Software Update New Feature Overview - February 2011.
EPOCH 1000 Series Software Update New Feature Overview July 2012.
RT10-B Rail Flaw Detector An implementation of testing truck on a push cart.
Lesson 5: Using Tables.
Configuring the MagicInfo Pro Display
APOLLO GX50/55 GPS Basic Operations. Introduction  This presentation is designed to introduce the basics of the GX50/55 GPS  Focus will be placed on.
Working with GPS Stephen M. Kiama (MSc) [Geo-information Specialist]
MagicInfo Pro Server Software All control, content, and scheduling is performed within the MagicInfo Pro Server software previously installed. Before.
Defining Styles and Automatically Creating Table of Contents and Indexes Word Processing 4.03.
EPOCH 1000i Feature Overview Encoded and Timed C-scan
STEP 1: Determining the exact image width STEP 1: Determining the exact image width Position of X-ray Filter Position of X-ray Filter STEP 5: Crop Extra.
11 Exploring Microsoft Office Excel 2007 Chapter 4: Working with Large Worksheets and Tables Chapter 04 - Lecture Notes (CSIT 104)
 Maintains the Instrument Database  Generates the Calibration Schedules  Maintains Calibration Records  Provides Facility to enter All types of.
BUDGET DEVELOPMENT Budgeting for Operations 1. –Budget 4% admin fee on designated indexes in account code 62889A –Please try to budget as close to actuals.
EPOCH 1000 Series Procedure Linear Scan and C-scan.
TxEIS Security A role-based solution October 2010.
© 2010 South-Western / Cengage Learning Century 21 Keyboarding  Cycle 1  Office Features 1.
O ptical R eturn L oss testing using KI 7340 series Loss Tester Kingfisher International PTY LTD V
CREATING TEMPLATES CREATING CUSTOM CHARACTERS IMPORTING BATCH DATA SAVING DATA & TEMPLATES CREATING SERIES DATA PRINTING THE DATA.
Intuitive Programming System For The Mill
EPOCH 1000i Feature Overview Weld Overlay. Weld Overlay Display Feature.
EPOCH 1000 Series Procedure Phased Array Angle Beam Calibration
Chapter 3 MATLAB Fundamentals Introduction to MATLAB Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
ResponseCard XR User Data Version 1.0 ®. Press the MENU button. ResponseCard XR.
Training Presentation
Version RAILER SMS RAILER RED (Remote Entry Database)
Wimba Pronto Setting Pronto Preferences of the ND University System April 2009.
Latest ROTOSCAN system development
Welcome to State of Michigan Managerial and SupervisoryAdvance Approval & Modification Approval & Modification Tutorial Brought to you by the Office of.
Welcome to State of Michigan Central Finance Advance Approval & Modification & Modification Tutorial Brought to you by the Office of Financial Management.
EPOCH 1000 Series Procedure Phased Array DAC/TVG.
Basic Navigation in Oracle R12 BY: Muhammad Irfan.
1 Chapter No. 9 Measurements and Detection of Radiation, Nicholas Tsolfanadis, 2010, McGRAW-HILL BOOK INTRODUCTION TO SPECTROSCOPY.
TDA Direct Certification
With GageView Pro v and the EPOCH 600
G&H Radiometer/Photometer Reset Notes
Presentation transcript:

EPOCH 1000 Series Software Feature AWS D1.1/1.5

AWS D1.1/1.5 The EPOCH 1000 Series includes AWS weld rating software as a standard feature. The EPOCH 1000 Series AWS software is intended to assist weld inspectors performing AWS-compliant inspections. The AWS software is available both in Conventional UT and in Phased Array modes on the EPOCH 1000 Series.

AWS D1.1/D1.5 The AWS code provides inspectors with a method to classify discontinuities found in welds using ultrasonic inspection. This code uses the following formula to develop an indication rating for a reflector found during an inspection: A – B – C = D A = Discontinuity Indication Level (dB) B = Reference Indication Level (dB) C = Attenuation Factor: 2 x (soundpath in inches – 1 inch) (dB) D = Indication Rating (dB) An AWS D1.1/1.5 inspector must take the Indication Rating (D) that is calculated based on A, B, and C to an Ultrasonic Acceptance – Rejection Criteria table produced by the AWS in order to classify the severity of the discontinuity that has been located.

Conventional UT AWS D1.1/1.5

AWS Setup: Conventional UT The first step in using the AWS weld rating software is to calibrate the instrument for the intended material, inspection range and general sensitivity. This includes: Appropriate Pulser and Receiver adjustments (filters, energy, square wave pulser, etc) Verification of wedge characteristics, such as Beam Index Point and Refracted Angle Calibration for probe delay (zero offset) and material velocity Appropriate screen range selection Sensitivity adjustment from reference

AWS Setup: Conventional UT Properly Calibrated EPOCH 1000

AWS Activation: Conventional UT Once the EP1000 has been properly calibrated: In Menu 4, Press [F1] to select Sizing Option Press [P3] to select AWS D1.1 Use the knob/arrow keys to turn the AWS option On or Off AWS Setup will now appear under [F2] ‘AWS’ will indicate that the AWS option is active

AWS Setup: Conventional UT Once AWS is activated, the user must set the Reference Level for the inspection: Press [P3] and use the knob/arrow keys to adjust the reference level according to the AWS code Bring the sensitivity reflector from the calibration block to the reference level by pressing [2ND F] then [GATES]

AWS Setup: Conventional UT Now set the reference reflector to the specified screen height: Press [P1] to record this gain value as REFB (Reference Gain Indication Level) Press [CHECK] to accept this gain value as REFB The EPOCH 1000 will now automatically rate all gated echoes with a D value!

Phased Array AWS 1.1/1.5

AWS Setup: Phased Array As with Conventional UT, the instrument must be properly setup before turning on the AWS weld rating software. This Includes: Correct probe and wedge selection (from PA Beam menu) Appropriate Pulser and Receiver adjustments (filters, energy, square wave pulser, etc) Calibration for material velocity and wedge delay (zero offset) Appropriate screen range selection If desired, calibration for Sensitivity/Gain can be performed as part of the AWS option setup

AWS Setup: Phased Array Properly Calibrated EPOCH 1000 Note: In this example the Sensitivity/Gain calibration will be performed as part of the AWS option setup.

AWS Activation: Phased Array Once the EP1000 has been properly calibrated: In Menu 4, Press [F1] to select Sizing Option Press [P1] to select AWS D1.1 Use the knob/arrow keys to turn the AWS option On or Off AWS Setup will now appear under [F2] ‘AWS’ will indicate that the AWS option is active

AWS Setup: Phased Array Once AWS is activated, the user must set the Reference Level for the inspection: Press [P7] and use the knob/arrow keys to adjust the reference level according to the AWS code

AWS Calibration: Phased Array The next step is to calibrate the sensitivity of the reference reflector for all focal laws. Using the 0.6” SDH on the IIW block, set the Gate start and width so that the measurement from the SDH can be acquired for all focal laws

AWS Calibration: Phased Array Set the angle between 45 and 55 degrees (it is recommended to use the same angle that was used for the zero calibration) Peak up the SDH reflector and adjust the echo to the previously set reference level Note: The Peak Memory ([PEAK MEM]) and Auto-XX% ([2ND F] [GATES]) features are helpful here

AWS Calibration: Phased Array Now set the calibration mode to AWS using [P7] Press [P1] Add to begin the calibration Move the probe over the SDH reflector to collect amplitude data across all focal laws NOTE: The sensitivity reflector indication must not leave the gated region or become saturated for any focal law NOTE: Use the Erase button to delete the curve and start again

AWS Calibration: Phased Array NOTE: If Sensitivity/Gain calibration has already been completed in a previous step, the unit will allow for the previous Gain calibration data to be used if desired. There may be a difference in reference levels between the original Gain calibration and the AWS reference level.

AWS Setup: Phased Array Press [P2] Done when curve is complete. Instrument will display 0CAL and TVG flags indicate that Zero and Gain calibrations have been performed and are being applied (Active). The EPOCH 1000 will now automatically rate echoes at 45, 60, and 70 degrees with a D rating!

AWS Reporting: UT and PA When the user saves inspection data in AWS mode, the instrument will record the A, B, C and D values for later review and reporting The information can be accessed through the Files > Open menu by selecting the ID and pressing Review

AWS Measurements: UT and PA The user can also manually select the AWS A, B, and C parameters as digital measurement readings from the Meas Setup > Reading Setup screen