VAPOR INTRUSION: AN INTRODUCTION OHIO COMMUNITY DEVELOPMENT CONFERENCE JENNIFER MILLER NOVEMBER 7, 2012.

Slides:



Advertisements
Similar presentations
CFD Modelling of Gas Freeing of VLCCs K. Chow University of Hertfordshire Fluid Mechanics Research Group 2006 European PHOENICS User Meeting.
Advertisements

Vapor Study Informational Meeting General Mills/Henkel Corp. Superfund Site Van Cleve Recreation Center November 12, 2013 Minnesota Department of Health.
Vapor Study Informational Meeting General Mills/Henkel Corp. Superfund Site Van Cleve Recreation Center November 12, 2013 Minnesota Department of Health.
PHASE II ESA INVESTIGATING IDENTIFIED CONCERNS. PHASE II ESA Why do we do it? To provide information relevant to: > Assessing whether there has been a.
Case Study of Subsurface Vapor Intrusion at a Dry Cleaner Site Amy Goldberg Day AEHS Annual East Coast Conference on Soils, Sediments.
Learning from the States… Commonwealth of Massachusetts
COMPARISONS OF SUB-SLAB SOIL GAS MEASUREMENTS TO MODELED EMISSIONS FROM SUBSURFACE CONTAMINATION by John A. Menatti and Robin V. Davis Utah Department.
2014 Vapor Intrusion Guidance Amendments Discussion Points Waste Site Cleanup Advisory Committee Meeting May 22, 2014.
Illinois Department of Nuclear Safety1 Radon Mitigation Overview So, you tell the homeowner that they have elevated radon. Now what do you tell them?
Radon in Your Home Presenter information here 4/2014.
Vapor Intrusion. What is Vapor Intrusion? The migration of volatile chemical vapors from the subsurface to overlying buildings.
Why Dilution may not always be a Solution Winnie Cheng, Regional Radiation Specialist AARST 2014 International Radon Symposium Charleston, South Carolina.
MPCA Citizens’ Board Information Item February 25, 2014.
Claremore Medical Office Building From Landfill to Medical Office Building A Brownfield Success Story THE GREEN SIDE OF BROWNFIELD REMEDIATION.
Radon. What is Radon Radon is emitted from the decay of radium It’s a radioactive gas that’s found naturally in the environment.
And the contamination of Industrial Wasteland Adam Stanley Jonathan Beeson.
Lesson 3 How does radon enter a home?. Slide 3-1 Predicted average indoor radon levels (U.S.) This map cannot be used to determine the radon level of.
Field Hydrologic Cycle Chapter 6. Radiant energy drives it and a lot of water is moved about annually.
EBC Seminar The IAQ/Mold Assessment – Getting it Right! – Controlling Your Risk Next Speaker Rosemary McCafferty Haley & Aldrich, Inc.
Lesson 3 How does radon enter a home?. Slide 4-1 Predicted average indoor radon levels (U.S.) This map cannot be used to determine the radon level of.
.
Vapor Intrusion Guidance Proposed Updates
DRAFT Field Sampling Guidance To be used this field season by DEC and consultants Initial focus on soil, groundwater, and vapor intrusion Future versions.
INDOOR AIR POLLUTION: RADON In 1990 EPA placed indoor air pollution at the top of the list of 18 sources of cancer risk Indoor pollution is rated by risk.
Kathy Metropulos Division of Drinking and Ground Waters Protecting your aquifer: What to consider when drilling oil and gas wells.
Radon Overview How Radon Enters the Home. Learning Outcomes Upon completion of this module you will be able to:  Recall the predominant source of radon.
Vapor Intrusion Evaluation Strategy and Modeling Developments
Overview of US EPA’s Vapor Intrusion Guidance VAP CP Summer Coffee July 14 th, 2015 Carrie Rasik Ohio EPA CO- Risk Assessor
MONITORING SYSTEM EVALUATION. INFORMATION GATHERING  Review previous LFG inspection reports  Identify specific probes to be sampled  Obtain monitoring.
©2002 Pearson Education, Inc. Upper Saddle River, New Jersey THE NATURE AND PROPERTIES OF SOILS, 13/e Nyle C. Brady and Ray R. Weil Chapter 7 Soil.
Guided Notes about Air Resources
Of Massachusetts Department ENVIRONMENTAL PROTECTION Soil Vapor Intrusion... A Decade of Regulatory Requirements & Experiences Paul W. Locke MA DEP Bureau.
DTSC VAPOR INTRUSION GUIDANCE California Industrial Hygiene Council 16 th Annual Conference Dan Gallagher Department of Toxic Substances Control California.
NYS Department of Environmental Conservation Customizing EQuIS to Manage Soil Vapor Intrusion Data Chris Mickle ICEDM Conference – Portland Oregon May.
Predicting Vapor Intrusion Risks in the Presence of Soil Heterogeneities and Anthropogenic Preferential Pathways Brown University Ozgur Bozkurt, Kelly.
Vapor Intrusion and Environmental Liability Learning From Past Mistakes EDR Insight Webinar, February 12, 2013 Presented by: Joseph Maternowski Hessian.
Background and lessons learned Managers Meeting February 13, 2014.
GeoSyntec Future Directions for Assessing Vapor Intrusion by Todd McAlary, GeoSyntec Consultants, Inc. AEHS VI Workshop October 19, 2004.
USEPA Region 2 Vapor Intrusion Study Cayuga Groundwater Contamination Site March 4, 2009.
Air Leakage and Water Vapor Control Chapter 6. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
Weathering Weathering is the physical breakdown and chemical alteration of rocks and minerals. Weathering happens on or near the surface. Weathering is.
Tyson Burt Mathieu Gagnon
Do Now 1. What is the atmosphere? 2.What are the main gases that compose the atmosphere?
GORE, GORE-TEX and designs are trademarks of W. L. Gore & Associates © 2007 W. L. Gore & Associates, Inc. 1 Environmental Investigations Using Versatile,
Today’s Lecture  Groundwater sampling. Announcements  Lecture  today: groundwater sampling  Thursday: HAZWOP – quiz (Bruce)  Lab  Lab 1: Phase I.
Radon in the home For most Americans, greatest exposure to radon is in home, especially in rooms that are Below grade (such as basements) In contact with.
Charge Questions for Expert Panel Modeling Vapor Attenuation Workshop Annual International Conference on Soils, Sediments, and Water October 19, 2004 Amherst,
The Water Cycle.  The amount of water on Earth is finite (which means that there is a limited amount).  All of the water present at the beginning of.
Flammable and Combustible Liquids Standard 29 CFR Part City of Council Bluffs Presented by: SilverStone Group © 2006, 2012 Zywave, Inc. All rights.
1 FORMER COS COB POWER PLANT From Characterization to Redevelopment Brownfields2006 November 14, 2006.
Evaluation of Methane Pathway, Risk and Control Rafat Abbasi, P.E., Senior Project Manager Brownfields and Environmental Restoration Program Department.
Vapor Study Informational Meeting General Mills/Henkel Corp. Superfund Site Van Cleve Recreation Center November 12, 2013 Minnesota Department of Health.
High Resolution Site Characterization Approach: Rapid Sample Collection with High Quality Analyses Targeting VOCs/SVOCs Presented by: Harry O’Neill, President.
The World of AUL Presentation by: Atul Pandey, P.E. PANDEY Environmental, LLC 2016 Ohio Brownfield Conference April 7, 2016.
Welcome to the World of AUL Avoiding the voidance of your CNS.
What’s the Problem: The Vapor Intrusion Issue Brownfields 2008 Heavy Starch: Cleaning the Dry Cleaners Detroit, MI May 5, 2008 Presented by: Henry Schuver,
Excavation & Trenching Awareness Plus
Dry Cleaning and the Environment
Chapter 10 Groundwater!.
General Principles for Hydrocarbon Vapor Intrusion
East Hennepin Avenue Site
Chemical Metals Industries, Inc. (CMI)
Sean Anderson, P.Eng., QPESA Steve Russell, B.Sc., QPRA
Using the HAPSITE® as a Vapor Intrusion Investigation Tool
At facilities with subsurface contamination, what other chemicals may your workers be breathing? Matt Raithel.
Connecticut Remediation Standard Regulations: Volatilization Criteria
Atmosphere Basics.
Radon Vapor Intrusion Screening Level Calculator
Chemical Metals Industries, Inc. (CMI)
VI Issues: Lessons Learned
Presentation transcript:

VAPOR INTRUSION: AN INTRODUCTION OHIO COMMUNITY DEVELOPMENT CONFERENCE JENNIFER MILLER NOVEMBER 7, 2012

VAPOR INTRUSION Vapor intrusion is the movement of soil gases, or vapors, into the air inside a building from the soil formation, through cracks or openings in the building foundation or basement.

VAPOR INTRUSION How does vapor move? > Unsaturated soil is porous, allowing vapor to diffuse through it just as it would through room air > Some soils and bedrocks, like clay and limestone, have seams or cracks along which vapor can move > Man-made porous areas (utility lines, old canals, building foundations) can also be preferential pathways for movement > Where soil meets basements, building slabs and crawl spaces, openings such as cracks, joints, sumps and utility penetrations can allow the vapor to move from the soil into the structure

VAPOR INTRUSION Vapor intrusion is aided by the stack effect, which can cause an upward air flow as warm air escaping through openings in the upper reaches of the building pulls in cooler make-up air in the lower reaches of the building. This can create a slight vacuum that pulls in additional soil vapor.

VAPOR INTRUSION The soil vapor can contain chemicals that are harmful when they accumulate in the building’s airspace: > Volatile/semi-volatile organic compounds from spills > Radon from soil minerals > Methane or hydrogen sulfide from buried decomposing wastes Effects can be near-term (e.g., explosion from accumulated methane) but are usually longer-term (e.g., cancer from exposure to a carcinogenic chemical)

VAPOR INTRUSION How to investigate: > ASTM E – Vapor Encroachment Screening > Review of government databases and historical records to look for potential vapor encroachment conditions within a set radius > Multiple cases in LJB’s experience show either poor application of the assumptions in this standard or field results that do not support the radius of effect set by the standard: proceed with caution

VAPOR INTRUSION How to investigate: > Information from Phase I ESA may also be used to identify potential sources > If a potential source of soil vapor is identified, soil vapor samples are collected, usually using hand-driven or hydraulically-driven rods and a vacuum pump

VAPOR INTRUSION Points to consider with respect to sampling: > The most important quality control check is to make sure no surface air has accidentally been pulled into the sample. Ideally, analyze the sample for atmospheric gases. For example, at depths of 3 feet or greater, oxygen should be very low compared to its atmospheric concentration of approximately 21% > Holding times for samples collected in Tedlar bags are as little as 24 hours – always check that analysis occurred in time

VAPOR INTRUSION Interpreting results: > U.S. EPA publishes indoor air screening levels with its Regional Screening Tables developed by Oak Ridge National Laboratory Risk of 1 in 1,000,000 Multiple chemical analysis may be necessary Tables are screening levels; site-specific levels should be developed if remediation is required

VAPOR INTRUSION Mitigation > Remediate source > Sub-slab vapor removal system Passive Active > Basement or crawl space venting > Air exchange ventilation system > Sealing of basement/foundation

VAPOR INTRUSION Confirm that mitigation is successful > Confirmation samples in soil/groundwater if source remediation is selected > Indoor air sampling if building modifications are selected At least two samples: one during hot weather and one during cold weather Also wise to plan for system maintenance and repair: O&M manual and tenant education is advisable

Questions?