BeginningNext SlideBack End Program AVADAL 1 of 15 SK-3 Rolls Rolls Will Not Extend/Extend Slowly
BeginningNext SlideBack End Program AVADAL 2 of 15 SK-3 Rolls 1. Are the isolation valves on SK-3 open?
BeginningNext SlideBack End Program AVADAL 3 of 15 SK-3 Rolls 2. Are the isolation valves on SK-5, SK-5A & SK-6 modules open?
BeginningNext SlideBack End Program AVADAL 4 of 15 SK-3 Rolls 3. Is there 650 psi at test point on SK-5, SK-5A & SK-6 modules?
BeginningNext SlideBack End Program AVADAL 5 of 15 SK-3 Rolls 4. Are 2 position 4 way Directional Valves M1 & M3 energized on SK-5, SK-5A & SK-6 modules?
BeginningNext SlideBack End Program AVADAL 6 of 15 SK-3 Rolls 5. Are Rotary Flow Dividers operating properly on SK-3 Modules?
BeginningNext SlideBack End Program AVADAL 7 of 15 SK-3 Rolls 6. Are Cross Line Pressure Relief Valves on module SK-3 set correctly?
BeginningNext SlideBack End Program AVADAL 8 of 15 SK-3 Rolls 7. Is there any mechanical binding?
BeginningNext SlideBack End Program AVADAL 9 of 15 SK-3 Rolls Roller Segments Will Not Retract/Retract Slowly
BeginningNext SlideBack End Program AVADAL 10 of 15 SK-3 Rolls 1. Are the isolation valves on SK-3 open?
BeginningNext SlideBack End Program AVADAL 11 of 15 SK-3 Rolls 2. Are the isolation valves on SK-5, SK-5A & SK-6 modules open?
BeginningNext SlideBack End Program AVADAL 12 of 15 SK-3 Rolls 3. Is there 650 psi at test point on SK-5, SK-5A & SK-6 modules?
BeginningNext SlideBack End Program AVADAL 13 of 15 SK-3 Rolls 4. Are 2 position 4 way Directional Valves M1 & M2 energized on SK-5, SK-5A & SK-6 modules?
BeginningNext SlideBack End Program AVADAL 14 of 15 SK-3 Rolls 5. Are Rotary Flow Dividers operating properly on SK-3 Modules?
BeginningNext SlideBack End Program AVADAL 15 of 15 SK-3 Rolls 6. Is there any mechanical binding?