IOT Measurements & Amplifier Improvements at Diamond

Slides:



Advertisements
Similar presentations
ESLS 04 Daresbury Laboratory
Advertisements

Andrew Moss ASTeC MICE RF workshop 16t h February 2012 Daresbury Laboratory Response to RF review for the MICE RF system.
Lighting concepts – Ballasts and Lighting Controls
Diamond RF Status Morten Jensen ESLS RF2004. Latest constructional Status Photo. by Angelos Gonias, DLS, Aug. 30 th 2004.
EMMA RF System Summary RF Requirements (S Berg): Aperture: –Aperture 34.7 mm (min) –Dispersion effects may increase by 3 – 4 mm Frequency: –Frequency range.
29 th June 2006EuroFEL DS5 Feedback Carl Beard EMMA RF Systems.
TS01 Klystron Modulator Minh Nguyen May 20, 2014 Beam Voltage Stability Improvements.
Andrew Moss ASTeC MICE Project Board 28 th June 2011 MICE RF System.
RF Safety Discussion Derun Li/Bob Rimmer Center for Beam Physics Lawrence Berkeley National Laboratory SRF Institute, JLab.
BEPCII RF POWER SYSTEM RF group, IHEP Sep ~ April 1.The 1 st transmitter had finished installing,commissioning and SAT (Site Acceptance Test).
MICE Refurbishment of CERN RF equipment for MICE M. Vretenar, CERN AB/RF.
Collaboration meeting, RAL, 4 th – 7th November 2009 Andrew Moss ASTeC Collaboration meeting, RAL, 10 th – 13 th november 2009 MICE RF Amplifier Status.
RF systems for MICE Andrew Moss The MICE RF Group and the TIARA WP7 Team Contributions include Daresbury, RAL, CERN, LBNL, LANL, FNAL, Strathclyde & Sheffield.
Andrew Moss Daresbury Laboratory August 2013 Latest results of MICE amplifier testing.
Indian Institute of Technology Hyderabad Vibration Detector.
Proton Source Workshop December 7 & 8, 2010 John Reid December 8, 2010.
Tom Kubicki.  Booster HLRF System to be upgraded using 1kW Solid State Driver (SSD) Amplifiers.  Used to drive the 200kW Power Amplifier  Eliminates.
Andrew Moss ASTeC 7 th December 2011 MICE RF System.
RF power & FPC status Eric Montesinos, CERN BE-RF on behalf of all people involved, great thanks to all of them !
Andrew Moss ASTeC Collaboration meeting CM29 15 th - 18 th February 2011 MICE RF System.
High Current Run I 2015 Feb 3 22:45 to Feb. 4 23:00 High Current Run II 2015 Feb 5 12:15 to Feb. 6 13:00 Current ~ 20 mA Approx. 40 trips, i.e. fast shutter.
Electrical & Control Power Supplies Trevor Hartnett.
HVPS Upgrade for ALS Storage Ring RF System -Disconnect Switch Status
February 17-18, 2010 R&D ERL Alex Zaltsman R&D ERL High Power RF Systems Alex Zaltsman February 17-18, 2010 High Power RF Systems.
Neutrino Factory Workshop, IOP, 28th October 2003 RF Systems David M Wilcox.
Anders Sunesson RF Group ESS Accelerator Division
MICE RF System Power Supplies, Control and Monitoring Status report February 2012 Chris White, STFC Daresbury Laboratory MICE Collaboration Meeting CM32,
Operational experience of high-power RF at Diamond Light Source Chris Christou, Pengda Gu, Alun Watkins Diamond Light Source.
Solid State RF High Power Amplifier Developments at SOLEIL Ti RUAN, on behalf of SOLEIL RF Group CWRF10 CELLS-ALBA Barcelona Spain May
Renovation of the 200 MHz RF system LLRF issues. Cavities redistribution 26 October th LIU-SPS Coordination Meeting 2  2011 : 4 cavities 2 x 4.
High Power RF System Status By: Peter McIntosh Klystron Department PEP-II Machine Advisory Committee Review October
14 th ESLS RF Meeting – Trieste, September 2010 ALBA RF Status 1/28 ALBA RF Status Francis Perez.
Commissioning of the ALBA IOT-Transmitters Paco Sanchez - 14th ESLS RF - ELETTRA, September Paco Sanchez, RF Group, CELLS (Consortium for.
Upgrades and EM simulations for the Diamond SR HP Amplifiers
ALBA RF Amplifiers based on IOTs CWRF08 - CERN, March 2008 Michel Langlois & Paco Sanchez 1 Michel Langlois & Paco Sanchez.
TRIGGER DELAY 100µs. G. Gräwer AB/BT/ECLBDS Trigger Delay2 The trigger delay is a back-up system that generates an asynchronous dump trigger for MKD and.
Other Utilities of ALBA LLRF
CWRF 2008, Geneva, March Alessandro Fabris on behalf of the Elettra RF Group Sincrotrone Trieste, Trieste, Italy. Elettra RF System Upgrade:
Operational experience of high-power RF at Diamond Light Source
CW and High Average Power Workshop BNL The Diamond Storage Ring IOT based High Power Amplifier Morten Jensen on behalf of the SR RF Group.
Stefan Wilke, DESY MHF-e 1 12th ESLS RF Meeting 1 st October, 2008 at DIAMOND Overview and Status of Assembling and Commissioning the RF-System at PETRA.
Status of the 1.2 MW MB-IOT for ESS Morten Jensen CLIC Workshop 2016, January, CERN.
13 th ESLS RF Meeting – 1 st October 2008 DAMPY Cavity 1/20 80 kW at Dampy Francis Perez.
Diamond LLRF Activities Pengda Gu For DLS RF Group.
650 MHz Solid State RF Power development at RRCAT
ALBA RF System Paco Sanchez - 13th ESLS RF - DESY, 30 September Paco Sanchez, RF Group, CELLS (Consortium for the Exploitation of the Synchrotron.
ALBA RF Systems Francis Perez.
Status of the Diamond Storage Ring RF Systems Morten Jensen on behalf of Diamond Storage Ring RF Group ESLS RF 2009.
Improvements to Diamond Light Source RF Amplifiers Peter Marten On behalf of the Diamond RF Group* *also C. Christou, P. Gu, M. Maddock, S. A. Pande, A.
Report on Sigmaphi 75 kW RFQ Amplifier and Ferrite 75 kW Circulator Ralph Pasquinelli November 18, 2014.
Andrew Moss ASTeC, Daresbury Laboratory October 2010 MICE RF Amplifier Status.
Status of the ELETTRA RF Plants
Electrical Configuration and System Protection
Report Technical Director Storage-Ring-Installation Completed
Storage Ring RF Systems
Observation of Failure Modes of RF Amplifiers at ATLAS
Overview of cavity reliability at Diamond Light Source
Status of RF at Diamond Light Source and overview of upgrade plans
352MHz Klystron Control for the 3MeV Linac test stand
RF operation of REX-ISOLDE
RF Matching Network Description
BEPCII RF POWER SOURCE AND INPUT COUPLER
CEPC RF Power Sources System
PEP-II RF System Status and Upgrades
M. Zerlauth, I. Romera 0v1.
An Optimal Procedure for RF Conditionning at the FREIA Laboratory
RF Local Protection System
Status and New Developments of ALBA RF Systems
Status and New Developments of ALBA RF Systems
IOT operation in the SPS Long term experience TWC 800 MHz
Presentation transcript:

IOT Measurements & Amplifier Improvements at Diamond Peter Marten Senior RF Technician Diamond RF Group 15th ESLS-RF Meeting, October 5-6th, ESRF

Agenda IOT Statistics Amplifier Trips IOT Measurements Amplifier Faults Modifications Current Projects

IOT Operating Hours Faulty 20 IOTs, 12 in 3 amps. 17 Working: SR Amp. 3 Faulty / Spare SR Amp. 1 Faulty RFTF/Test Amp. 2 20 IOTs, 12 in 3 amps. 17 Working: 10 IOTs have combined operating hours over 141,000 hours (2 IOTs have operated for > 25,500 hours) All 10 are still working well 7 Spare IOTs undergoing conditioning 2 IOTs waiting for further investigation 3 Faulty: 1 Failed during initial e2v commissioning (2007), replaced under warranty 1 Failed during setup, Si contamination Leaky ion pump on delivery, replaced under warranty

Amplifier Trips No. of Trips 2010: 17 trips, 9 ISC trips (mostly new IOTs) 2011: 6 trips, 3 ISC (to date) No. of Trips

Trips IOT Short Circuit Focus PSU Geometry @ 500 MHz Output dead: no +5 V supply to Isolated logic or analogue comparator circuits > switching regulator not fired Random noisy signal causing triggering of interlock signal

Trips Toaster IOT Bias Supply Water Other Faulty wiring Input cavity fault Water Faulty flow monitor switch Other Load arc > before arc detector upgrade Human error

Transfer Curve

Effect of High Voltage on Gain Reduce ISC trips @ 33 kV? Gain -0.5dB (60 kW) Plenty of drive available in DA to compensate

Effect of High Voltage on Efficiency 5% increase in efficiency (33 kV) Operation at 80 kW is easy HV > control room No re-tune required

Effect of Output Coupling on Efficiency Same efficiency if OLC tuned Problem: Can’t increase power instantly to 80 kW Danger of tube damage if run in undercoupled region Undercoupled

Effect of Filament Voltage on Power

Amplifier Faults Water System Blackened Cu collector (268-0851) failed at 80 kW during tests compared with an example after 8 years service in a TV transmitter

Amplifier Faults Water System Si contamination IOT failed during conditioning at 80 kW IOT Power limited to 60 kW Coolant and Cu collector analysed > Si Dowcal 10 formula had changed Decontaminated water systems Replaced with 40% Thermocal C

Modifications PSM AHU belts replaced (Optibelt) Smoke detectors installed inside HVPS PSM PSI 04 current measurement board modified Second AHU for rack and IOT cooling Drive amplifier coax upgraded (<loss, RF, life)

Water Upgrade Project Secondary System with Glycol Primary Cooling Current System x 3 Secondary System with Water Reject Loads Primary Cooling

Water Upgrade Project Provide duty and standby pumps Eliminate glycol from IOT cooling Improve present water system (disturbance during repairs often causes unrelated leaks) Ideally remove Glycol requirement from reject loads (H & S, messy, reduced cooling efficiency) Simplify design to cool all three systems from one secondary water system (R. load modelling)

The Water Load Development

The Water Load The present load uses a mixture of 40% Glycol and 60% Water Need to maintain a separate circuit(?) The new load will use pure water Easier maintenance

The High Power Co-axial Load Matched to the input transmission line Absorb all the input power Remove the heat generated by water circulation Section at A-A A Input A Slowly introduce water while keeping matched so that the wave attenuates on its forward travel Extra length to absorb remaining energy d and d1 are changed in steps to keep impedance matched and introduce more & more water

Dielectric Properties of Water & Glycol 40% Glycol-Water Mixture @25C Pure Water @25C Dielectric Constant () 56 78 Loss Tangent (tand) ~0.2 ~0.024 Glycol Impedance matching is relatively easy Good absorber of RF Power  Fast attenuation leading to compact design Water Impedance matching is relatively difficult Not a good absorber of RF power  Slow attenuation leading to increased length

Numerical Design of Water Load Using CST Studio Time Domain / frequency Domain Solvers

Numerical Design of Water Load E – Field Due to relatively low tand there is still enough energy left at the end. Need more sections of Teflon Design in progress The Load

Fast IOT Fault Detection and Isolation Purpose IOT breakdown is single largest amplifier fault Fault on one IOT isolates HV for all 4 IOTs Typically 10-15 trips per year / 8 IOTs in operation Recovery is fast – but beam is lost Possible solution Detect IOT fault (µs) Isolate IOT HV (dissipated energy < 9J) Maintain beam –> Other IOTs to ramp up Re-instate IOT -> Other IOTs ramps down

Successful First Test of Principle Fast IOT Fault Detection and Isolation Successful First Test of Principle Close up of IOT turn OFF and ON Cavity 1 Voltage Small voltage disturbance during switching Cavity voltage Forward Power Beam current = 210 mA Reflected Power IOT 2, 3, 4 IOT 1 OFF IOT 1 IOTs 2, 3 and 4 UP IOT power Note IOT 1 turned off and IOTs 2,3 and 4 compensate 20 ms Preparation: Quench Detector turned OFF Reflected power trip turned off

Ongoing Work Signal debounce and first fault reporting Filament management HV PSM regulation investigation at certain loads

On behalf of the RF Group Morten Jensen Pengda Gu Matt Maddock Peter Marten Shivaji Pande Simon Rains Adam Rankin David Spink Alun Watkins Thank you for your attention