DKE German Commission for Electrical Electronic & Information Technologies of DIN and VDE Dipl.-Ing. (FH) Dirk Barthel FB 2/ Series DIN VDE 0100 (VDE 0100) Low-voltage electrical installations DKE/K 221 Elektrische Anlagen und Schutz gegen elektrischen Schlag German mirror committee IEC/TC 64 and CLC/TC 64 Electrical installations and protection against electric shock
International (worldwide) Series IEC „Low voltage installations“ IEC/TC 64 „Electrical installations and protection against electric shock“ with MTs, PTs European (region) Series CENELEC HD „ Low voltage installations“ (former HD 384) (implementation of IEC with some modifications and perhaps national deviations) CENELEC/TC 64 „Electrical installations and protection against electric shock“ with its WGs nad PTs German (national) Series DIN VDE 0100 (VDE 0100) „Low voltage electrical installations“ (implementation of CENELEC HD and some remaining former requirements which are not covered by CENELEC HDs) German mirror committees with the interested parties (national in Germany): DKE/TC 221 with its SCs 221.1, 221.2, 221.3, and WGs and PTs Dipl.-Ing. (FH) Dirk Barthel FB 2/
DIN VDE 0100 (VDE 0100) Low-voltage electrical installation Group 200/Part 200: Definitions Group 100/Part 100: Fundamental principles, assessment of general characteristics Group 300 : assessment of general characteristics have been transferred to part 100 Group 400: Protection for safety Group 700: Special installations or locations Part Part 410: Protection against electric shock Part 420: Protection against thermal effects Part 430: Protection of cables and cords against overcurrent Part 440: Protection against overvoltages Part 450: Protection against undervoltages Part 460: Isolation and switching Group 500: Selection and erection of electrical equipment Part 510: Common rules Part 520: Wiring systems Part 530: Switchgear and controlgear Part 540: Earthing arrangements Part 560: Safety services Part 550: Other electrical equipment Group 600: Verification *) *) Periodic verification see DIN VDE (VDE ): Initial verification with the clauses: - Inspection - Testing Part 100 up to 600 = General parts 7XX parts contain particular requirements which are based on the requirements of the general parts and have to be considered in conjunction with them. Part 443: Protection against overvoltages of atmospheric origin or due to switching Part 444: Protection against voltage disturbances and electromagnetic disturbances e. g. Part 701: Locations containing a bath or shower
Overview (extract) on IEC (series) „Low-voltage electrical installations“ IEC Structure IEC IEC IEC IEC Chapter -442 Chapter -443 .... IEC Chapter -551 ./. Chapter -559 IEC CLC Structure HD HD HD HD HD .... HD HD (NWIP) HD HD HD Dipl.-Ing. (FH) Dirk Barthel FB 2/
The way from IEC :2012 to DIN VDE (VDE ): CONTENTS FOREWORD Scope …. 421Protection against fire caused by electrical equipment 421.1General requirements Precautions where particular risks of fire exist 422.1General … Selection and erection of installations in locations with endangering of irreplaceable goods 423Protection against burns 424Protection against overheating Annex A (informative) List of notes concerning certain countries …. LOW-VOLTAGE ELECTRICAL INSTALLATIONS – Part 4-42: Protection for safety – Protection against thermal effects Dipl.-Ing. (FH) Dirk Barthel FB 2/
Original (basic) text of IEC (extract) Dipl.-Ing. (FH) Dirk Barthel FB 2/
IEC List of notes concerning certain countries (extract) (informativ) Dipl.-Ing. (FH) Dirk Barthel FB 2/
IEC (extract) Some Country Note (SCN) Dipl.-Ing. (FH) Dirk Barthel FB 2/
CENELEC - HD : Foreword The text of the International Standard IEC :2010, prepared by IEC TC 64, Electrical installations and protection against electric shock, together with common modifications prepared by the Technical Committee CENELEC TC 64, Electrical installations and protection against electric shock, was submitted to the formal vote and was approved by CENELEC as HD on ….. Endorsement notice The text of the International Standard IEC :2010 was approved by CENELEC as a Harmonization Document with agreed common modifications as given below …. COMMON MODIFICATIONS 422Precautions where particular risks of fire exist Add the following note: NOTE 3Other locations having similar risk as those mentioned in IEC , Table 51A, BE2 should also be considered, for example commercial kitchens …….. Dipl.-Ing. (FH) Dirk Barthel FB 2/
CENELEC - HD Special national conditions (extract) (informative)
DKE - DIN VDE (VDE ) (extract) German Standard Including - Common modifications out of HD : Special National Conditions (SNCs) out of HD : purely national Notes (mainly informative) - …
DKE - DIN VDE (VDE ) (extract) original IEC text Special National Condition (SNC) from HD pure national NOTE
DKE - DIN VDE (VDE ) (extract) Special National Condition (SNC) from HD pure national text Dipl.-Ing. (FH) Dirk Barthel FB 2/
Thank you very much for your visit! & Looking forward to a succesful co-operation! Dipl.-Ing. (FH) Dirk Barthel FB 2/