Inspection & Preventive maintenance of breakers

Slides:



Advertisements
Similar presentations
L.T Circuit Breakers.
Advertisements

Seminar on Circuit Breaker
Detail Discussion on Different type of Circuit Breaker
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Preventing Equipment Failures
Electrical Installation
© Abb Control Ltd - 1 ABB Protection - Overload What do we mean by a fault? Overload Operating condition in an electrically undamaged circuit which causes.
1S25 Arc Fault Monitor. 1S25 Arc Fault Monitor 1S25 Arc Fault Monitor Electrical arc short circuits in metal clad switchgear may occur for many different.
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
MOLDED CASE CIRCUIT BREAKER BASICS
Utility Management Providence Health System - Oregon Environment of Care.
Chapter 9 Radio Maintenance MComm – Ch Confidence Testing Preventive Maintenance Corrective Maintenance Summary Overview MComm – Ch9 - 2 >>
Quad Plus Shredder Drive Maintenance Joe Kowalkowski Engineering Manager – Recycling Industry
© ABB Ltd - ATLV /26/2015 Insert image here Fuses vs Fuseless Technology.
ACADs (08-006) Covered Keywords Switchgear, motor control, ground, circuit breaker. Description Supporting Material
MAIN ELECTRICAL SURVEY ITEMS, GENERATORS AND GOVERNORS,, CIRCUIT BREAKERS, SWITCHBOARDS AND FITTINGS (Adapted from:D.T. Hall:Practical Marine Electrical.
Unit 5 Bench Testing, Maintenance, and Troubleshooting.
SUBSTATION HIGH VOLTAGE COMPONENTS
Flanders Electric – Engineering Division Welcomes Youto an Overview of Reconditioned Switchgear.
Miniature Circuit Breakers (MCB) Multi 9
Breaker Basics Welcome to this general overview of ABB.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
Quality Service Providing Quality Performance.
Troubleshooting Electric Control Devices
Area of Study 2: Electricity
By R. Vijay Krishna. CONTENTS  INTRODUCTION  WORKING PRINCIPLE OF C.B  TYPES OF CIRCUIT BREAKERS  SF6 CIRCUIT BREAKER.
ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008 Guest Palace Hotel Doha, Qatar Engr. Amado B. Taduran Philippine Association of Safety Engineers.
Objectives Review electric circuits and electricity pricing - Introduce HW5 Select conductor and conduit List electrical devices.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety INSTRUCTOR’S NOTES:
Technological World. Electrical Function An electrical function is the role that a component plays in the control or transformation of electric current.
Circuits and Electronics. Circuits A circuit is a closed path through which a continuous charge can flow. A circuit is a closed path through which a continuous.
ADT490 TroubleShooting Device Failures. 2 Introduction ‣ Many problems are external to FAS ‣ Many are device problems.
Vadodara institute of engineering,kotambi NAME:NAFISKHANPATHAN(13ELEE181) BARIYA VIPUL(13ELEE182) PATEL AMIT(13ELEE180) BRANCH:EE-2 PPT OF EEE.
Circuit breakers The main purpose of a circuit breaker is to: Switch load currents Make onto a fault Break normal and fault currents Carry fault current.
Brookhaven Science Associates Accelerator Safety Workshop Lessons Learned at C-AD Accelerators E. Lessard August 7-9, 2007.
SAFETYSAFETY. Overview ●Introduction to Safety ●Potential Electronic Mishaps ●Safe Work Practices.
Submitted to: Submitted by:
Electricity Notes 5 Electric Power – the rate at which _______________________ the rate at which _____________________ is converted into another form of.
Main contacts closed – RED Colour with ON
Practical experience with the AD Stochastic Cooling Murphy’s Law R. Louwerse.
VACUUM CIRCUIT BREAKER. WHAT IS A CIRCUIT BREAKER A circuit breaker is an equipment that breaks a circuit either manually or automatically under all conditions.
Condition Monitoring of Circuit Breakers and Switchgear
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Electrical Safety. What is a short circuit? Connection that allows current to take the path of least resistance. Easiest possible path. Path with the.
Group names  أبوبكر عبد المعز & عبدالله سلامه. Circuit breakers  Circuit breakers are be considered one of the most important component in power systems.
IDENTIFYING SYMPTOMS OF SURPRISE ELECTRICITY (ELECTRIC SHOCK)
ONLOAD TAP CHANGING TRANSFORMER
Circuit Protection Unit 9.
3AH5 Vacuum Circuit-Breaker For Standard Applications
2017 Fall Educational Forum Bruce A. Tagg, ALCM
3AH5 Vacuum Circuit-Breaker For Standard Applications
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Fuel Supply System Service
Air Circuit Breaker This type of circuit breakers, is those kind of circuit breaker which operates in air at atmospheric pressure. After development of.
Components of Substation
ELECTRICAL POWER-II Electrical engineering sixth semester
The Safe Use of Electricity
SWITCH GEAR AND PROTECTION(IV-1) TOPIC-CIRCUIT BREAKER
Objectives Learn about Electricity Pricing Electric systems.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

Inspection & Preventive maintenance of breakers 1

Why and what has to be maintained on breakers ? Case Mechanism Arc chute Main contacts Control unit Connection systems Auxiliary Devices Communication system 2

Maintenance of case Function of case : isolate the main contacts and protect from arcing effects support the mechanism, tripping device, auxiliary devices, terminals Must withstand the stresses during short circuit Damaged case is the consequence of : shocks, moisture, high short circuit, overheating ( loose connection) Preventive maintenance includes : visual inspection of dust, dirt, grease, moisture, cracks, soot, cleaning, ( dust, dirt, soot,) with dry cloth, brush or vacuum cleaner replacement in case of cracks

Maintenance of the mechanism Breaker mechanism Spring energy on Masterpact Tumbler on Compact NS operate the contacts to establish and interrupt the circuit Chassis mechanism to rack in and out the breaker, test the breaker Jammed mechanism is the consequence of : dust : shocks : bending of mechanical part corrosive atmosphere : rust and corrosion of metallic part No operation for a long time Preventive maintenance includes : dust removal : vacuum cleaner recommended cleaning : dry cloth, brush, solvent prohibited greasing : only Schneider recommended greases, in small quantity operation of breaker / chassis : to give the spring charged energy and the mechanism their original characteristics

Maintenance of the arc chute (Power breaker only) Function of arc chute : splitters : extinguish the arc and absorb the energy under normal condition and electric fault filter : blow the pressured gas out , cool down the gas Arc chute deteriorates under In : the insulation material of the arc chamber can perforate under Icc : the metal part is vaporised Arc chute in bad condition may result in a non interruption of the arc, decrease of the isolating function and ultimately destruction in case of high short circuit current. Filters : avoid compound (made of dust + grease) covering the filter Preventive maintenance includes : periodic inspection after a fault : splitters should not present holes and be too thin, plastic part should not have holes ( decrease of insulation level) replacement cleaning of filter

Maintenance of main contacts (Power breaker only) Function of main contacts : To make or break the circuit under normal ( In) or fault conditions (overload and Short-circuit ) Contacts get worn during each mechanical and electrical open / close operation and after short circuit ( maxi 2 cycles at Icu) Worn contacts will result in : over heating of the breaker ( increase of contact resistance) decrease of life expectancy Preventive maintenance includes : periodic visual check, control of the mechanical contact wear indicator and electronic wear indicator on Micrologic P & H measurement of individual pole resistance replacement

Maintenance of electronic control unit Function of control unit : permanently analyse the phase current compare it to the protection set and in case of fault trips the breaker Control unit is sensitive to : environment : ambient temperature, humidity, corrosive atmosphere, operating conditions : vibration, electro-magnetic field, A malfunctioning of the trip unit will result in : a non interruption of the fault current damage of equipment and breaker Preventive maintenance includes : periodic push to trip test or trip test control of the complete tripping channel curve adjustment saving of log event, settings ( Micrologic P & H)

Maintenance of thermal-magnetic trip unit Function of thermal-magnetic trip unit : Connected permanently in series with the phase currents based on the bending of a bimetal for overload and the movement of a magnet in a strong magnetic field Thermal -magnetic trip unit is sensitive to : ambient temperature, corrosive atmosphere A malfunctioning of the trip unit will result in : a non interruption of the fault current damage of equipment and breaker Preventive maintenance includes : primary injection test to trip the breaker

Maintenance of connection systems Function of connection systems : Link together various types of devices by mean of electrical distribution systems (bus bars, cables, auxiliary wires, ). Bad connection ( too tight or too loose) will result in : Thermal effect leading to destruction of devices short circuit or fire Preventive maintenance includes : For fixed connectors : No need of control if done with Schneider recommendation . otherwise : check temperature rise, if loose, dismantle and tighten with new screws, bolts & washers For sliding connectors : (mainly chassis) periodic cleaning and greasing with Schneider recommended grease if corrosive atmosphere ( SO2 / H2S) : clean with special solution ( Thiourée) and re grease Wires : check tightening and the insulation material

Maintenance of auxiliary devices Function of auxiliary devices : Shunt trip release, under voltage release, OF contacts, SD/SDE alarm contacts , electrical motor MCH Malfunctioning of the auxiliary device will result in a wrong operation of the breaker the consequences can be : no safety operation ( emergency) wrong operation in the circuit Preventive maintenance includes : functional test of auxiliary device at nominal voltage replacement

Maintenance of communication systems Function of communication systems : allow the dialogue with control unit ( read, write) allow the remote control of breaker ( open close) Bad communication will result in : loss of information (status, monitoring, maintenance, production) loss of control of breaker Preventive maintenance includes : testing of reading network parameters testing of reading setting and changing setting testing of remote control