Round Robin II Calibration/Test Results Impact of Burner Tab and Intake Duct on Calibration/Test Results Variations in Burner Air Turbulators Discovered
Round Robin II Calibration Requirements Thermocouple Rake Temperatures: 1850+/- 100 o F Heat Flux: /- 0.8 Btu/ft 2 sec Air Intake Velocity: /- 50 ft/min
Round Robin II Recommended Burner Configuration 10:00 Position 1 Tab in Top Left Position 3.75-Inch Distance from Nozzle Tip to Turbulator Static Disc In Draft Tube
Round Robin II Material Combinations: 1) 2 Layer 0.60 lb/ft 3 Fiberglass 2) 1 Layer Nextel Ceramic Paper/2 Layer 0.42 lb/ft 3 Fiberglass 3) 2 Layer 0.60 lb/ft 3 Curlon 4) 1 Layer TTI Felt/1 Layer 0.42 lb/ft 3 Fiberglass
FAATC Round Robin II Tab/Igniter Arrangement
Various Burner Arrangements Used in Round Robin II
Influence of Tab and Intake Duct on Calibration and Test Results
Position of Flame Deflection Tab
No Tab/With Duct (NTWD) 4 Burner Configurations: With Tab/With Duct (WTWD) No Tab/No Duct (NTND) With Tab/No Duct (WTND)
Tab/Intake Duct Test Conclusions Burner Calibration Influenced More From Tab Than Duct Test Results Influenced More From Burner Set-up Than Calibration No Tab = Temp Calibration = Quicker Failure Time/
Influence of Turbulator on Calibration and Test Results
Differences Between “Old” and “New” Park Burners OldNew No Static DiscStatic Disc 2 3/4 -Inch Turbulator2 5/8 -Inch Turbulator Opposing Turbulator FlowIdentical Turbulator Flow
Old and New Style Turbulators OldNew 2 3/4 ” I.D.2 5/8 ” I.D. C.C.W. C.W. 4” O.D. 3 7/8 ” O.D. C.W. No Disc Disc
Burner Equipment Assortment
Monarch H215 Turbulator with Static Disc