ODS/GHG Reduction: Options in Foams February 2011.

Slides:



Advertisements
Similar presentations
A 2030 framework for climate and energy policies Marten Westrup
Advertisements

Indo-US Workshop on HFCs Incorporated in the year : 1991 Number of Members : 250 Headquartered at : New Delhi Category of Members : Individual,
102 May 2011 Scenarios of ODSs and ODS substitutes Guus Velders.
1 HCFC Phase –out in Air Conditioning Sector Background, Challenges and Progress Sidi Menad SI AHMED 17 TH October 2012.
Workshop on ODS Bank Management (OEWG-30) Geneva, Switzerland Monday 14 June 2010 Timing, Size and Cost of ODS Bank Management Opportunities Paul Ashford.
HFCs: A Critical Link in Protecting Climate and the Ozone Layer Alternatives to high-GWP HFCs UNEP side-event, Montreal Protocol MoP-23, 21 November 2011.
T E A P a n d T O C s - A s s e s s m e n t , M O P - 20, D o h a 1 The TEAP and TOC 2010 Assessment Reports Timelines and issues that will be dealt.
Updates on alternative technologies and international developments in the Refrigeration and Air Conditioning Sectors.
5.6 DEPLETION OF STRATOSPHERIC OZONE. the progression of the Ozone hole over the antarctic from 1970 to 1997.
CFC/HCFC MANAGEMENT Training Conference 2013 – Chicago, IL
1September 18, 2013 The role of HFCs in ozone and climate protection Guus Velders (RIVM) David Fahey (NOAA) The Netherlands (RIVM)
The Challenge: Moving Away From HCFC Refrigerants.
HYDROFLUOROCARBONS DRAFT UK CLIMATE CHANGE PROPOSALS Significant change in HFC emissions Total figures fall between 1990 and 2010 Strong underlying upward.
CFCs/HCFCs Warrington Williams – Thanks to John Meyer Environmental Affairs Director John Morrell & Company.
POLICY ON HFC IN SEYCHELLES Presented by Inese Chang-Waye National Ozone Coordinator.
A Corporate Perspective: the Significance of the Kyoto Mechanisms Tom Jacob DuPont October 29, 2002 UN Framework Convention on.
Iglu Cold Systems Winning with Co2. Iglu Cold Systems is one of an exclusive group of companies to have invested in the development of a complete range.
New Refrigerants Question Time Introductory Comments Ray Gluckman Director, Climate Change SKM Enviros April 26 th 2012, RAC, London.
Smooth Transition; Using Safe And Cost-effective Gaseous Blowing Agents The Benefits of HFC-134a & HCFC-22/142b Technology.
SOLVAY Phasing out ozone-depleting substances: Industry responses to more sustainable consumption and production Jacques de Gerlache, Ph.D. senior toxicologist.
R22 Phase Out Presentation To inform our customers of the single most important changes to the air conditioning industry in modern.
Current and Future HFC Demand
REFRIGERATION & AIR CONDITIONING DIVISION Hydrocarbons for Domestic Appliances Dr.-Ing. Jürgen Süss VP R&D Brussels, October 2009.
Region and sector specific HFC scenarios and effects of MP proposals
HFC WORKSHOP Agustín Sánchez Guevara Ozone Unit Coordinador.- México PARIS, FRANCE JULY 2014.
1 Current and Future HFC Demand by Sectors Bella Maranion TEAP co-chair OEWG-35, Bangkok, 22 April 2015.
Summary of the rapporteurs Key conclusions of the Workshop on HFC Management: Technical issues K. Shepardson / S. Sicars OEWG Bangkok 22 April 2015.
Département fédéral de l'environnement, des transports, de l'énergie et de la communication DETEC Office fédéral de l'environnement OFEV Swiss policies.
DuPont™ FEA-1100: Zero ODP, Low GWP, Non-Flammable Alternative for DuPont™ FEA-1100: Zero ODP, Low GWP, Non-Flammable Alternative for HCFC-141b Helen Walter-Terrinoni.
The Effect of Blowing Agent on Energy Use and Climate Impact Example of Refrigerator and Building Insulation Tim. G.A. Vink Honeywell Fluorine Products.
Refrigerant Management
1 ALTERNATIVE TECHNOLOGIES TO CFCs AND HCFCs OZONE CELL GOVERNMENT OF INDIA MINISTRY OF ENVIRONMENT & FORESTS.
HFC PHASEDOWN: INDIAN PROPOSAL Ministry of Environment, Forest and Climate Change Government of India 21 st. July 2015 Paris, France.
Overview of EU Regulations affecting the use of Fluorinated Greenhouse Gases Tim G.A. Vink Director Regulatory Affairs, Compliance & QA Honeywell Fluorine.
Session 5 Overarching and cross-cutting issues on technical aspects of HFC management.
HFO Low Global Warming Technology Rene Mueller. Honeywell.com  2 Honeywell initiated R&D on low global warming programs in 2001 Programs in place for.
INDIAN INDUSTRY PERSPECTIVE ON PHASE DOWN OF HFC S REFRIGERANT GAS MANUFACTURERS ASSOCIATION (REGMA) INDO-US WORKSHOP ON HFCs 18 th February, 2011.
Mahendra Senevirathne Project Coordinator National Ozone Unit Sri Lanka 17 September
Availability of Low-GWP Alternatives Options for Near Term & Longer Term Transitions OZONACTION NETWORK FOR LATIN AMERICA AND THE CARIBBEAN OCTOBER 6-8.
Refrigerants. Background 1850’s – 1870’s: ammonia, ammonia/water, CO 2 Early 1900’s: SO 2, methyl chloride used for domestic refrigerators 1930’s: halocarbon.
XPS INDUSTRY Mena Region  Alternatives currently offered to the XPS industry, compromises on physical properties, cost constraints on process development.
Energy efficiency in buildings Monga Mehlwana Tuesday, 05 October 2010.
Modelling Long Term Hydrofluorocarbon Emissions Contribution to India's Global Warming Impact Mohit Sharma Junior Research Associate Council on Energy,
WORKSHOP: MANAGING F-GASES THE FOAM INDUSTRY’S NEEDS FOR HFCs FOAM INDUSTRY REPRESENTATION XPS   EXIBA Phenolic   EPFA Polyurethane   ISOPA   BING,
HCFC management and strategy in Hungary and Europe Róbert Tóth Ministry of Environment and Water Budapest, Hungary.
Using Montreal Protocol to Protect the Climate Kristen N. Taddonio U.S. Environmental Protection Agency Stephen O. Andersen Co-Chair, Technology & Economic.
Ozone Depletion Reducing the manufacture and release of halogenated organic chemicals.
Implementing AB 32: California’s Approach to Reducing Greenhouse Gas Emissions National Association of Clean Air Agencies Spring Membership Meeting May.
In the 1970’s, scientists discovered the dangerous impact that CFC’s have in the Earth’s atmosphere. They were destroying the ozone layer which protects.
Maximising the climate benefits of the HCFC phase-out European Commission 36th OEWG, Paris, 20 July 2015 Lunch time Meeting: The EU amendment proposal:
INDUSTRY PROGRESS AND NEEDS FOR REPLACING HIGH GWP HFC S Montreal Protocol HFC Management Workshop Paris July 11, 2014.
Challenges Faced by Companies in Article 5 Parties in Converting to Low-GWP options R K Mehta RAMA – INDIA 20 th & 21st April 2015 Bangkok.
Safe and commercially viable low GWP alternatives For micro, small and medium enterprises in A5 & Non A5 countries. Safe and commercially viable low GWP.
Contents Plastic extrusion process, section of machine (Mikeeg555 [Wikipedia] 2011). XPS Extruded Polystyrene in use as insulation in buildings. (Selector.
Ozone Depleting Substances & Fluorinated Greenhouse Gases.
Update on HPMP preparation Art. 5 and CEIT ECA Network meeting - May 18-22, 2009 Yerevan, Armenia.
BY SHASHANK. S. SURVE TEJAS. N. PAWAR. CONTENTS  INTRODUCTION:-  ABOUT HFO -1234yf.  STRUCTURAL FORMULA.  NEED OF HFO-1234yf.  WHY NOT R-134a SHOULD.
Importance of NIK Alternatives to Phase Down of High GWP HFCs Steve Seidel and Jason Ye (C2ES), Stephen O. Andersen (IGSD), and Alex Hillbrand (NRDC) 28.
F-Gases.
HFC and Global Warming Presented by Mohammad Reazuddin
Commercial Refrigeration Trends and challenges for RECS
THIRD ANNUAL CO3OL WORKSHOP
Hydrocarbon Refrigerants
Refrigerants.
Low-GWP blowing agents as alternatives of HCFC-141b
ODS AND ALTERNATIVES IN RAC SECTOR
ON ALTERNATIVES TO HCFC-141b IN PU FOAM MANUFACTURING SECTOR
CHALLENGES IN MEETING 2020 HCFC PHASE OUT TARGETS
Introduction to HPMP.
Presentation transcript:

ODS/GHG Reduction: Options in Foams February 2011

Honeywell.com India: February Forces: commercializing new molecule(s) Environmental regulation or restriction.... EU F-Gas Directive: restricts the use of materials with GWP > 150 in emissive applications –Restricts the use of HFC-134a in specific applications –EU one component foam industry regulation: 04 July 2008 –EU novelty aerosol industry regulation: 04 July 2009 Kyoto Protocol: Developed countries reduce GHG emissions 5% (1990) – EU reduce GHG emissions by 8% (1990 levels) –Japan striving to meet Kyoto commitments Industry concern with further GWP regulation Taxation of raw materials basis GWP values –Economic impact on finished goods Climate Change bills in U.S. Congress Globally: reduction in ODS and climate change Environmental regulation is now driving commercialization

Honeywell.com India: February Fluorine Products – a History of Innovation Innovation Tied to Environmental Compliance CFCs HCFC Phase-out HFOs 1900s 1990s 2000s2010s CFC Phase-out F-Gas Regulation HCFCs HFCs MONTREAL PROTOCOLEU LEGISLATION Ozone Depleting and Very High Global Warming Potential Non-Ozone Depleting but has High Global Warming Potential Low-Global-Warming Potentials and No Ozone Depletion Effect Markets Served: Mobile and Stationary Air conditioning, Refrigeration, Insulation Foam for Buildings and Electrical Appliances, Cleaning Solvents, Nuclear Power, Aerosols, Heat Pumps, Geothermal and Solar Renewables

Honeywell.com India: February Montreal Protocol calls for HCFC-141b phase out Montreal Protocol on Substances that Deplete the Ozone Layer Baseline average of 2009 and 2010 Freeze 2013 Reductions: 10%m : 2015 > 35% :2020 > 67.5% : 2025 > 2.5% per year reduction 2030 to 2040 Complete phase out 2040 HCFC-141b has been phased out in United States, Japan and Europe –HCFC transitioned the industries to environmentally improved materials Global pressure may accelerate the phase out date in other countries –example: India and UAE, as well as others HFCs are utilised where key needs demanded are: –insulation performance, and energy efficiency of finished products (refrigerators) –non-flammability property Hydrocarbons, and other non-HFC materials, while flammable, may be used: –where deficiencies in insulation performance and flammability can be tolerated –spray foam industry is particularly sensitive to flammability (application / equipment) HCFCs successfully phased out in many countries

Honeywell.com India: February Blowing Agent Attributes Phase out of ozone depleting substances: ODS Global warming potential: climate change impact reduction Ground level smog formation: limited contribution Low order of toxicity – safety in manufacturing use and finished products Non-flammable – safety in manufacturing use Insulation performance / energy efficiency: low lambda or k-factor Processing and equipment implications –Liquids: appliance (refrigerators); commercial refrigeration; spray foam; insulating panels –Gases: extruded polystyrene (thermoplastics); special applications Compatible with formulations and processing equipment materials –Low conversion cost: equipment investment and reformulation Economic valuation in use – translates into finished product economics Commercially available on a global basis Attributes support governments and industrys preferences

Honeywell.com India: February What is HFC 245fa?

Honeywell.com India: February HBA-2: Liquid Low GWP Blowing Agent Fluorochemical Liquid blowing agent Molecular weight: less than HFC-245fa Environmental Properties Low global warming potential: GWP 100 = 7 Non-flammable: ASTM E-681 Volatile Organic Compound: very low MIR Toxicity Screening Preliminary stages: Results are very promising Assessments completed: –Cardiac Sensitization –Genetic Testing: Ames Assay & Mouse Micronucleus –Acute Inhalation (Rat) –Inhalation: 2 & 4 week –Unscheduled DNA Synthesis Honeywell HBA-2 Blowing Agent promising low GWP molecule

Honeywell.com India: February HFC-245fa & HBA-2 Insulation Applications Household refrigerators (appliances) Commercial refrigeration –food preservation Building construction (residential and commercial) –Sprayed foams –Roofing and sheathing (board stock) –Panels (faced panels, sandwich panels)

Honeywell.com India: February HFO-1234ze(E) Blowing Agent Hydrofluoroolefin (HFO) trans – 1,3,3,3 – tetrafluoropropene CHF = CHCF 3 Molecular Weight: 114 Gas: T BP = -19 °C (- 3 °F) Environmental Properties Zero ozone depletion potential (ODP) Low global warming potential: GWP 100 = 6 Non-flammable: U.S. Department of Transportation –Non-flammable Compressed Gas –No flame limits by ASTM E681 –Non-flammable: EU Test Method A11 Volatile Organic Compound Measure –Maximum Incremental Reactivity MIR HFO-1234zeE < MIR Ethane Non-ODS / Low GWP / Non-Flammable / Low POCP = Environmentally Sustainable Molecule =

Honeywell.com India: February HFO-1234ze(E) Insulation Applications Extruded thermoplastics foams –Extruded polystyrene One component foams –Sealing around doors and windows –Repairing damage –Adhesives Two component pressurized foams

Honeywell.com India: February Transition Strategy: Timeframe Dependent HFC-245fa: Commercially available today – a transition solution – Widely utilised in NA. Specific applications: EU / Japan / China – HFC/HCFC-141b blend technology: reduced cost transition option HBA-2: World-scale capacity target is mid-decade – Conversion to HFC-245fa directly applicable to HBA-2 HFC-245fa: Low capital, medium term safe route to ODS management

Honeywell.com India: February Blowing Agent Energy Efficiency (Lambda) Lambda is the measure of heat transfer through a material in a given time and temperature Lower lambda is better: significant energy efficiency driven by insulation characteristics When compared to HCFC-141b insulation performance: – HFC-245fa is equal to slightly better – HBA-2 has shown improvement over HFC-245fa – HFC-245fa/HCFC-141b blends should exhibit similar insulation performance Transitioning: HCFC-141b HFC-245fa HBA-2 maintains energy efficiency

Honeywell.com India: February Sprayed Foam Comparison: HFC-245fa & HBA-2 Low water formulation High water formulation

Honeywell.com India: February Capital Investment: HFC versus non-HFC Why are HFC-245fa and HBA-2 blowing agents low capital investment? They are non-flammable none to limited capital requirement –Low risk – technology, workplace safety, environmental HCFC-141b PUR equipment little to no equipment modifications required Both are liquid blowing agents with moderate vapour pressure –May require storage vessel up-grade low capital investment HFC-245fa conversion from HCFC-141b in US: Cost Minor Why are Non-HFC (hydrocarbon & methyl formate) blowing agents challenging? Generally flammable significant investment in flammability mitigation – Blending operations; foaming equipment; storage vessels – Consequences of miss-operations inherent risk of fire / explosions Factory emissions probable ground level smog formation Non-HFC PUR foams typically exhibit deficiency in insulation performance Non-HFC conversion in US: Cost $500 K USD to $ 5 M+ USD HBA-2 is a LOW capital investment, near drop-in transition from HFC-245fa (small asset) (refrigerator factory)

Honeywell.com India: February Operational Cost: Implications HFC = lowest total cost path to high performance for regulatory compliance Non-HFC solutions have inherent energy efficiency penalty – Cost to restore energy efficiency: panels – low cost; refrigerators – high cost Non-HFC solutions exhibit deficiencies in density, dimensional stability, LTTR* * LTTR: Long Term Thermal Resistance Non-HFC PUR requires additional costs to achieve equal performance

Honeywell.com India: February HFC Solutions Summary ODS and GWP reduction is imperative on a global basis HFC solutions: thru HFC-245fa bridge route... –Provides a balanced, technology neutral / low capital investment pathway –Positions the industry for future HBA-2 adoption –HFC-245fa and HBA-2 do not contribute to ground level smog formation –Non-flammable: inherently safer utilisation in applications HFCs allow for orderly industrial transition: – Frees up ODS rights under an ODS Cap – Accommodates industrial and economy growth HCFC-141b / HFC blends possible attractive solution –ODS reduction on an interim basis –Energy efficiency neutral with respect to operational costs –Economic valuation: low capital investment & raw materials cost reduction

Honeywell.com India: February Blowing Agent Commercialization Status HFC-245fa –Registered for use globally –Commercially available globally –Commercial manufacturing site: 2002 in U.S. 1234ze(E) –U.S.: SNAP listed / PMN pending EPA approval –EU: Registered under REACH (article 24): tonnes/year –Japan: Registration complete –Commercial capacity: 2008 in U.S. –Commercialized in EU and Japan HBA-2 –Toxicity assessment underway: completion 1Q 2011 –Global notifications/registrations U.S.: SNAP / PMN applications are in progress EU: REACH inquiry stage Japan: Filed for compliance with Japan Chemical Substances Control Law Environmental solutions have/will meet regulatory needs timing

Honeywell.com India: February DISCLAIMER Although all statements and information contained herein are believed to be accurate and reliable, they are presented without guarantee or warranty of any kind, expressed or implied. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments, and the user assumes all risks and liability for use of the information and results obtained. Statements or suggestions concerning the use of materials and processes are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patents. The user should not assume that all toxicity data and safety measures are indicated herein or that other measures may not be required.

Honeywell.com India: February 2011 Specific Innovation Requiring Regulatory Approval –Excellent Environmental / Physical / Economic Properties GWP of 7 ODP < Non-flammable Atmospheric Life < 50 days –Tremendous Potential as HFC / HCFC Replacement Low GWP Material Designed for Traditional Applications Foam Blowing Agent: Insulation Performance 3-5% Better vs.HFC-245fa Solvent: Exhibits Very Attractive Solvent Performance Properties Refrigerant for Chillers: Applications Testing by Major OEMs –Hurdle to Overcome: Lack of Environmental / Legal Certainty ODP Lower Than Many Non-regulated Chlorinated Solvents –Methylene Chloride: ODP: Atmospheric Life: ~ 180 days –Perchloroethylene: ODP: 0.006Atmospheric Life: ~ 110 days Very Low POCP Compatibility (Plastics and Most Elastomers) Similar Economics to Current HFC No Certainty in Status Quo – Threshold Value Needed