Instruments for Radiation Detection and Measurement Lab # 4.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

NUCP 2371 Radiation Measurements II
Instruments & Radiopharmaceutical Production
Lab B4: The Creation and Annihilation of Antimatter SFSU Physics 490 Spring 2004 Professor Roger Bland.
Liquid Scintillation Counter And Contamination Monitoring Training Presented by: Ali Shoushtarian Office of Risk Management October 2009.
King Abdul-Aziz University Diagnostic Radiology Department MS.Nouf Al-Zahrani DR. Saddiq Jastniah Introduction to Nuclear Medicine 2 nd year.
Dispersive property of a G-M tube HV - + In the proportional region a G-M tube has dispersive properties tube voltage.
Chapter 8 Planar Scintigaraphy
Scintillators. When radiation interacts with certain types of materials, it produces flashes of light (scintillation) Materials that respond this way.
Fysisk institutt - Rikshospitalet 1. 2 Overview Gamma camera Positron emission technology (PET) Computer tomography (CT) Proton therapy Electrical impedance.
1. 2  Ray Imaging u Inject a pharmaceutical labelled with a radioactive nuclide  Detect where  -rays are coming from u Local concentration in patient.
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
Gamma Camera Technology
Computed Tomography RAD309
Instruments for Radiation Detection and Measurement
Radiation Sensors Zachariadou K. | TEI of Piraeus.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Gamma Spectroscopy HPT TVAN Technical Training
. 2 RCRS provides: Pick-up and delivery of meters Required 9-month calibration Preventive maintenance and repairs Shipping for extensive repairs RCRS.
Conventional and Computed Tomography
RAD 466-L 8 by Dr. Halima Hawesa
Instruments for Radiation Detection and Measurement Lab # 3 (1)
LEC ( 2 ) RAD 323. Reconstruction techniques dates back to (1917), when scientist (Radon) developed mathematical solutions to the problem of reconstructing.
Positron Emission Tomography
ADC PRE-PATIENT COLLIMATION POST-PATIENT COLLIMATION.
BASIC PHYSICS & RADIOPHARMACY & INSTRUMENTATION in NUCLEAR MEDICINE by Prof. Dr. Haluk B. Sayman.
Innovation is in our genes. 1 Siemens Medical Solutions Molecular Imaging What are SPECT basics?
بسم الله الرحمن الرحيم و الشمس تجري لمستقر لها ذلك تقدير العزيز العليم صدق الله العظيم.
Pulse-Height Analyzers Basic Functions Single Channel Analyzers Time Methods Multi-channel Analyzers.
Md.Kausher ahmed Electrical department. Biomedical engineering Code:6875.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
3/2003 Rev 1 II.3.4 & 13-15a – slide 1 of 31 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 4,Liquid.
Introduction to nuclear medicine technology NMT 231 Aya Ahmed Saeed.
Nuclear Medicine Principles & Technology_I
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Detection of Radiation Contents: Geiger tubes Photo-Multiplier tubes Cloud Chambers Solid State devices.
Simulating the Light Distribution in Sodium Iodide Detectors Lisi Goodlett Dr. Ingo Wiedenh ö ver.
CAT scanners and gamma cameras Unit 16 Waves. Learning objectives Describe how CAT scanners can produce a much more detailed image than conventional X-rays.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Chapter-2 The Planar Imaging Gamma Camera
Introduction to Gamma Camera
Chapter-4 Single-Photon emission computed tomography (SPECT)
Chapter-2 The Planar Imaging Important points in chapter 2 (chapter 13 from the book) The gamma camera (the basic principles of the gamma camera) The types.
Nuclear Medicine Introduction
 Two reasons medical tracers can be placed in a body:  Diagnose disease or Treat Disease  In both cases, several factors must be accounted for:  Gamma.
PET Imaging Positron Emission Tomography
Muhammad Musaddiq.
Chapter-5 Positron emission tomography (PET)
Gamma Camera Technology
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
Nuclear Medicine Physics
P.E.T. Positron Emission Tomography
Image quality and Performance Characteristics
Gamma Camera.
Function and Structure in
Lecture 1: Development of the Analog Gamma Camera
CLRS 321 Nuclear Medicine Physics & Instrumentation I
Gamma-Gamma Correlations in Na-22
Scintillation Counter
Nuclear Medicine Physics & Instrumentation I
Lecture 1—Basic Principles of Scintillation
Gamma Camera & Basic Principles
Function and Structure in
Gamma Camera Ilker Ozsahin Oct
Nuclear Medicine Introduction
3/9/2019 L13-L14 1 Instruments for Radiation Detection & Measurement PRINCE SATTAM BIN ABDUL AZIZ UNIVERSITY COLLEGE OF PHARMACY Nuclear Pharmacy (PHT.
Radioactivity B. Sc. -III Feb Dr. Wagh G. S. M. Sc. M. Phil. Ph
Assist. Prof. Dr. Ilker Ozsahin Oct
Presentation transcript:

Instruments for Radiation Detection and Measurement Lab # 4

In nuclear medicine it is important to ascertain the –Presence –Type –Intensity –Energy of radiations emitted by radionuclides Two commonly used devices –Gas-filled detectors –Scintillation detectors

Scintillation Detecting Instruments g-ray detecting equipment Most commonly used: –well counters –Thyroid probes –g or scintillation All these instruments are g-ray detecting devices Consist of: Collimator (excluding well counter) Sodium iodide detector Photomultiplier tube Preamplifier Pulse height analyzer Display or Storage

Scintillation detectors consist of scintilator emitting flashes of light after absorbing gamma or x radiation. The light photons produced are then converted to an electrical pulse by means of a photomultiplier tube. The pulse is amplified by a linear amplifier, sorted by a pulse-height analyzer and then registred as a count. Different solid or liquid scintillators are used for different types of radiation. In nuclear medicine, sodium iodide solid crystals with a trace of thallium NaI(Tl) are used for gamma and x ray detection.

g rays from a source interact in the sodium iodide detector and light photons are emitted. The light photons will strike the photocathode of a photomultiplier (PM) tube and a pulse is generated at the end of the PM tube. The pulse is first amplified by a preamplifier and then by a linear amplifier

Scintillation Camera also known as a gamma camera consists of : Collimator Detector X, Y positioning circuit PM tubes Preamplifiers Linear amplifiers PHA Display or storage

Collimator classification of collimators used in scintillation cameras depends primarily on –The type of focusing –The thickness of the holes Depending on the type of focusing –parallel hole –Pinholet –Converging –Diverging type

Pinhole collimators are used in imaging small organs such as thyroid glands Converging collimators are employed when the target organ is smaller than the size of the detector

diverging collimators are used in imaging organs such as lungs that are larger than the size of the detector Parallel hole collimators are most commonly used in nuclear medicine procedures.

Parallel hole collimators are classified as high- resolution, all-purpose, and high-sensitivity types. The size and number of holes the same for all these collimator The only change is in the thickness. High sensitivity collimators are made with smaller thickness than all-purpose collimators High-resolution collimators are made thickest of all.

Detector NaI(Tl) crystals used as the detector Rectangular in shape Have the dimension between 33 X 43 cm and 37 X 59 cm with thickness varying between 0.64 cm and 1.9 cm The most common thickness is 0.95 cm The 0.64-cm thick detectors are usually used in portable cameras for nuclear cardiac studies

Detector Increasing the thickness of a crystal increases the probability of complete absorption of g rays and hence the sensitivity of the detector

X, Y Positioning Circuit When a g ray interacts in the crystal, its exact location is determined by the X, Y positioning circuit Many PM tubes are mounted on the NaI(Tl) crystal in scintillation cameras After g-ray interaction in the crystal, a maximum amount of light will be received by the PM tube nearest to the point of interaction

Pulse Height Analyzer circuit that sums up the output of all PM tubes to produce a pulse known as the Z pulse that represents the energy of a g ray The SCA analyzes the amplitude of the Z pulses and selects only those of desired energy by the use of appropriate peak energy and percent window settings In many scintillation cameras, the energy selection is made automatically by pushbutton type isotope selectors designated for different radionuclides such as 131I, 99mTc

Pulse Height Analyzer In some scintillation cameras, two or three SCAs are used to select simultaneously two or three g rays of different energies

Display and Storage most cameras employ digital computers in acquiring, storing, and processing of image data

Tomographic Imagers limitation of the scintillation cameras is that they depict images of three-dimensional activity distributions in two- dimensional displays One way to solve this problem is to obtain images at different angles around the patient such as anterior, posterior, lateral, and oblique projections Success of the technique is limited because of the complexity of structures surrounding the organ of interest –Single Photon Emission Computed Tomography –Positron Emission Tomography

Tomographic Imagers mathematical algorithms, to reconstruct the images at distinct focal planes (slices).