Field fluorometers for the hydrogeology: Improved separation of uranine from other dye tracers using laser light Pierre-André SCHNEGG CHYN, rue Emile Argand.

Slides:



Advertisements
Similar presentations
Richard Young Optronic Laboratories Kathleen Muray INPHORA
Advertisements

Spectrophotometer.
Absorbance spectroscopy
Announcements Homework for tomorrow…
Determination of Concentration Using Spectrophotometry
Yu. I. BARANOV and W. J. LAFFERTY Optical Technology Division Optical Technology Division National Institute of Standards and Technology, Gaithersburg,
Vertical Distribution of Photosynthetic Pigments in Bamfield Inlet and Trevor Channel Ashlee Lillis Eosc 473.
SPECTROPHOTOMETRY IN BIOTECHNOLOGY
Avoiding bleed-through artifacts on the confocal microscope Fluorescent dyes are molecules that, when exposed to light of a specific range of wavelengths,
OPTICAL ABSORPTION.
Absorbance spectroscopy
AAS and FES (Ch 9, 7th e, WMDS)
Flame Test Lab.
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Absorption Spectroscopy (AAS) The Visible Spectra.
Atomic Emission Spectroscopy
Photosynthesis AP Lab. Dr. Lourdes Rueda. Key Concepts I: Plant Pigment Chromatography Paper chromatography is a technique used to separate a mixture.
Telescopes (Chapter 6). Based on Chapter 6 This material will be useful for understanding Chapters 7 and 10 on “Our planetary system” and “Jovian planet.
Determining the k a of an acid- base indicator Experiment 3.
Determining the ka of an acid-base indicator
Light and sound are the two major ways that we receive information about the world. Of the two, light provides the greater variety of information. The.
Richard Young Richard Young Optronic Laboratories Kathleen Muray Kathleen Muray INPHORA Carolyn Jones Carolyn Jones CJ Enterprises.
Introduction to Instrumental Analysis - Spectrophotometry
What is Chromatography? Derived from the Greek word Chroma meaning colour, chromatography provides a way to identify unknown compounds and separate.
Flame Photometry Flame atomic emission spectrometry
Abab And we continue with the hows and whys of analogue soundtracks, from conventional silver tracks over high magenta up to the final dye tracks.
The ANTARES experiment is currently the largest underwater neutrino telescope and is taking high quality data since Sea water is used as the detection.
SPECTROPHOTOMETRY. Determines concentration of a substance in solution by Measures light absorbed by solution at a specific wavelength by using spectrophotometer.
Color in image and video Mr.Nael Aburas. outline  Color Science  Color Models in Images  Color Models in Video.
Fundamentals of Multimedia Chapter 4 : Color in Image and Video 2 nd Edition 2014 Ze-Nian Li Mark S. Drew Jiangchuan Liu 1.
NucleoCounter YC-100 Presentation
SPECTROPHOTOMETRY IN BIOTECHNOLOGY
Quality Assurance How do you know your results are correct? How confident are you?
Electromagnetic radiation travels through space in the form of a wave, with the distance between two crests of a wave termed a wavelength. At one end.
Gas Chromatography Lecture 38.
Factors Affecting Stability of Quinidine Melissa Usry and Sharmistha Basu-Dutt Department of Chemistry, University of West Georgia, Carrollton, GA
Dam Removal as a Solution to Increase Water Quality Matthew Nechvatal, Tim Granata Department of Civil and Environmental Engineering and Geodetic Science.
The Effect of Annealing Conditions and Concentration on 5 D 3  7 F J Emission in Terbium-doped Sol-gel Glasses * Colleen Gillespie and Dan Boye, Davidson.
Topic 1 Tools of the Biology Laboratory Exercise I. The spectrophotometer. Exercise II. Liquid Measurements. Exercise III. Sedimentation and Centrifugation.
Determination of Concentration Using Spectrophotometry
Molecular Luminescence Spectroscopy
Colorimetric determination of manganese in steel
UNI Plant Physiology Measuring Light Absorbance UNI Plant Physiology Spring 2005.
SPECTROPHOTOMETRY IN BIOTECHNOLOGY. LIGHT IS A TYPE OF ELECTROMAGNETIC RADIATION Imagine electromagnetic radiation like waves on a pond – But instead.
Spectrophotometric Methods For Determination Of Proteins
Absorption Spectroscopy CHEM 251 Week of November 1 st, 2010 Alexis Patanarut.
Topic 1 Tools of the Biology Laboratory Exercise I. The spectrophotometer. Exercise II. Liquid Measurements. Exercise III. Sedimentation and Centrifugation.
Biology 227: Methods in Modern Microscopy Andres Collazo, Director Biological Imaging Facility Yonil Jung, Graduate Student, TA Week 10 Multispectral Imaging.
Forensic Photography
Carbol Fuchsin (Basic Fuchsin/Phenol) Doped with Lugol's Iodine
Flame Emission Spectrometry
Short Answer Review Some M/C questions will be taken from concepts learned in “sacred” labs.
Vision Basics Lighting I. Vision Basics Lighting I.
Absorbance Demo Tutorial
Introduction to Spectrophotometry
Introduction to Spectrophotometry
Investigation of Lasers and Play-Doh
Absorbance spectroscopy
Vernier Spectrophotometer
Flame Test Lab.
Absorption Spectroscopy
Volume 95, Issue 11, Pages (December 2008)
Volume 91, Issue 8, Pages (October 2006)
Volume 99, Issue 8, Pages (October 2010)
SPECTROPHOTOMETRY Applied Chemistry.
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
Sample AP Model Drawing Question
Colourimetry The absorption of light by a coloured solution is directly related to the concentration of the solution. Colourimetry determines the concentration.
Immunofluorescence Microscopy cell Biology Ptactical 3
A Low-cost, User-friendly, Smartphone-based
Presentation transcript:

Field fluorometers for the hydrogeology: Improved separation of uranine from other dye tracers using laser light Pierre-André SCHNEGG CHYN, rue Emile Argand 11, CH-2009 Neuchâtel - Switzerland ABSTRACT Flow-through field fluorometers for the hydrogeology are employed in tracer tests for detection of small concentrations of dye tracers. It is convenient to be able to detect several tracers with the same sonde. However, tracers with similar optical properties are difficult to separate with the LED sources used in conventional fluorometers. We replaced one of them by a green laser rod. Its narrow wavelength distribution allows separate a cocktail of three favorite tracers, otherwise hard to achieve without laboratory techniques: Uranine, eosin and rhodamine. 532 nm LASER 470 nm LED 520 nm LED Uranine absorption Amidorhodamine G absorption Eosin absorption Injection site Detection site 650 m The flow-through fluorometer is a waterproof stainless steel cylinder hosting a vertical glass tube illuminated by four LEDs. In this research, one of the LEDs was replaced by a 532 nm green laser rod. A set of color filters and condensers (for the LEDs and photo detectors) completes the set-up (not required for the laser!) The new design was tested in a small stream (0.8 m 3 / s). In the first test, 1 g eosin was injected 650 m upstream at am and 1 g uranine at am. In the second test, 5 g eosin, uranine and amidorhodamine G were injected the next day at am, am and am. Water turbidity was slightly above 10 NTU. Absorption spectra of three dye tracers and light spectra of two LEDs and the green laser. Interestingly, uranine is hardly excited by the laser, easing the separation of the three dye tracers. This operation is done by solving the set of three linear equations of three unknown concentrations. Test 1 – Two tracers : Eosin and uranine were injected in the stream at 10 minute interval. Only two optics were active at a time. Figs. 1 and 2 show the breakthrough curves after mathematical separation (eosin: red and blue, uranine: green). The 470 nm LED was kept active. In Fig. 1, the second optics was the 525 nm LED. In Fig. 2, it was the laser. There is no visible difference. In the other figures, only one light source was active. The fluorometer is not instructed of the presence on uranine in the water. Fig. 3 was measured with the 525 nm LED. The breakthrough curve is erroneous and delayed (red arrow) because this LED excites uranine as well as eosin. Fig. 4 was obtained by illumination with the green laser. This time, the eosin curve is correct since the laser does not see the uranine Test 2 – Three tracers : Three tracers were injected at 5 minute intervals: Eosin, uranine and amidorhodamine G (5 g each). In spite of some turbidity (>10 NTU), the three breakthrough curves are well separated. A good separation of three optically similar dye tracer requires careful calibration of the sonde: Same batch of tracers for calibration and tracer test, calibration of the sonde in a 10 ppb solution prepared with the stream water, at the temperature of the stream. As a rule of thumb, good separation is achieved if the tracers are in relative concentrations higher than 1:10. Fig. 5 shows instabilities occurring on the baseline of tracers of smaller concentration ratio. 5 www-geol.unine.ch/geomagnetisme/tract.html 2008 Joint Annual Meeting Celebrating the International Year of Planet Earth October, 2008 | Houston, Texas, USA