Round Table Meeting Part I

Slides:



Advertisements
Similar presentations
Bedridden Code Issues in RCFE’s Working with Your Local Fire Authority
Advertisements

NFPA-101, LIFE SAFETY CODE, 2003 EDITION Chapter 15 Existing Schools
2009 Edition – NFPA 101 Steve Hornyak, DAHC, CDT, FDAI
College and University Fire Prevention
OSHA Office of Training and Education
7 | Means of Egress (Life Safety Code)
MEANS OF EGRESS.
Determining the Occupant Load
Electronic Locking and Exemption Request Form Training
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Licensing Section Updates Governor Foster has recently appointed two new members to the Advisory Board. Ronnie Whiddon of Custom Security of Baton Rouge.
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Denver Fire Alarm Test Preparation Speed Drill © Ted Smitty Smith 2013.
NFPA 72 - National Fire Alarm Code Chapter 4 - Notification Appliances
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS
of NFPA 101 Life Safety Code 2000 Edition Means of Egress
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
High-Rise Hotels New Codes General Fire Safety Information Ted Erb Fire Prevention Officer Bellevue Fire Department April
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
N.F.P.A. 13R Justin Bohlmann FIR-204.
January 16, 2014 Brad Keyes, CHSP Changes to the 2014 Acute Care & Critical Access Hospital Manuals on Life Safety Compliance.
Assisted Living Communities: Changes & Challenges November 20, 2014 Central Georgia Technical College Macon, GA.
Cancer Center Training 2012 Cancer Center Training 2012 “Defend in Place” Strategy for Fire Alarm Activations Cancer Center Building #7559.
Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL 2560 NOTES ABOUT THIS PRESENTATION: Review Oxygen-Enriched Environments.
Retirement Home Regulated under the Retirement Home Act, 2010.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
FIRE ALARM SYSTEMS AND FUNDAMENTALS
WELCOME DBI & SFFD Meet the Pros October 11, 2007.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Chapter 14: Inspection and Maintenance
Emergency Action Plans
EGRESS AND FIRE PROTECTION
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Means of Egress Chapter 4.
The Association of Electrical and Medical Imaging Equipment Manufacturers Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL.
Fire Safety By Alicia Civile and Alexandra Fernandez.
© 2015 American Society for Healthcare Engineering, a personal membership group of the American Hospital Association 155 N. Wacker Drive, Suite 400 | Chicago,
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
Area of Refuge It’s the Law!
Means of Egress Part 3 Chapter 4.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Code Officials and the Code Process.  Concentrates on the code process as a whole.  Different type of code officials  Various steps that are taken.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
Means of Egress Don Ebert- Risk Manager (509)
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Fire Alarm Verification CAN/ULC-S561-03
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Louisiana AFAA Quarterly Meeting State Fire Marshal Questions
Carbon Monoxide Detection: Code and Legislation Updates
Fire Protection Systems Chapter 9 IBC 9th Edition Amendments
Louisiana AFAA State Fire Marshal Questions Quarterly Meeting
Proposed Changes to the 2009 International Building & Fire Codes
NICET Fire Alarm Tech Level 1 Practice Test
Fire Alarm Systems for Emergency Operations of Elevators
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
MINNESOTA STATE FIRE MARHSAL DIVISION HEALTHCARE TEAM
General Requirements of NFPA 101
Presented by: Tim Knisely
Fire Alarm Tech Practice Test # 16 NICET
Presentation transcript:

Round Table Meeting Part I LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY Louisiana Burglar & Fire Alarm Association Convention New Orleans 11/15/01 Round Table Meeting Part I

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY 1. Most security systems have three (3) emergency buttons, (1) for fire, (1) for medical, (1) for police notification. When installed in commercial applications can the fire button be active? Yes, provided the combination fire alarm/security system is listed for commercial use by a recognized testing organization.

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY 2. Follow to # 1. If yes, does the installing company have to carry a D-1 license and submit the system as a non-conforming, non-required system? If the proposed fire alarm system is not required by code, then a contractor with a “D-1” or “D” license can submit on a Non-Required Exemption Request Form. If the proposed fire alarm system is required by code, then a contractor with a “D” license shall submit the shop drawings, cutsheets, battery calculations and sequence of operation for an official plan review.

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY 3. NFPA 72 1999 5-5.3.2.1.11 If a DACT is programmed to call a telephone line (number) that is call forwarded to the line (number) of the DACR, a means shall be implemented to verify the integrity of the call forwarding feature every 4 hours. If a toll free number is pointed (thru the long-distance carrier's switch) to a DACR number, does the integrity of the toll free number have to be verified every 4 hours? No. Appendix “A” further explains that “Call forwarding should not be confused with WATS or 800 service. The latter, differentiated from the former by dialing the 800 prefix, is a dedicated service used mainly for its toll-free feature; all calls are preprogrammed to terminate at a fixed telephone line (number) or to a dedicated line.”

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY Guidelines for Schools Conducting Self Inspections of Fire Alarm Systems Part II

Provides additional information to School Officials. LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY Provides additional information to School Officials. Helps them to understand their responsibilities concerning the fire alarm systems. Identifies what actions need to be taken if the system is yellow or red tagged. Provides guidance to prevent impairment to the system. Explains when to conduct fire alarm drills. Outlines a Self-Inspection Checklist Not mandated by the State Fire Marshal. It is a service!

Special Locking Arrangements Issues for Exemption Request Forms LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code Special Locking Arrangements Issues for Exemption Request Forms Part III

Everyone is now “security minded.” LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY Dramatic increase in submittals for “special locking systems” since the September 11, 2001 terrorist attacks. Everyone is now “security minded.” Not to reduce the minimum life safety features required by the Life Safety Code. Many of the Exemption Request Forms are being denied, because contractors are not providing all of the required information.

Let’s look at Memorandum 2000-9. LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY Let’s look at Memorandum 2000-9. Per R.S. 40:1574, any renovation to an existing building requires the submittal of plans to this office prior to renovations being performed. The addition of access control or delayed egress locking devices falls into the definition of renovation. The following information is required to be submitted by the building owner anytime that access control or delayed egress locking devices are installed in a building other than One or Two Family Dwellings. 1. Completed access control and delayed egress locking systems exemption request form. 2. The necessary fees - $20.00 3. A description of how the system will work. 4. Manufacturer’s specification sheets for the system and devices. If the building has a fire alarm system, then the exemption request form shall include the locking system connection to the fire alarm and a description of how the locking system will interface with the fire alarm. (cont.)

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY Memorandum 2000-9 (cont.) Please note that a Class D license is required to perform any work on a required fire alarm and a Class D-1 license work on a non-required fire alarm. A burglary license is required to perform work only on a burglar alarm system. If the building is protected by an automatic sprinkler system, then the exemption request form shall include the locking system connection to the sprinkler system and a description of how the locking system will interface with the sprinkler system. Please note that if the automatic sprinkler system is “supervised” in accordance with 101:7-7.2, then only a contractor with a Class “D” license can perform this work. Should you have any questions regarding this matter, please contact the Plan Review Section of this office at 1-800-256-5452 or 225-925-4920. This memorandum voids and replaces Memorandum 2000-2, dated January 5, 2000.

Not providing the manufacturer’s cutsheets on the system and devices. LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY What are some of the typical oversights that are causing these exemption request forms to be found not in compliance? Not providing a written description of how the system will function and interact with the life safety features of the building. Not providing the manufacturer’s cutsheets on the system and devices. Not submitting both the “Special Locking System” Exemption Request Form and the “Fire Alarm Modification” Exemption Request Form at the same time, if Contractor “A” installing the locking system and Contractor “B” is connecting to the fire alarm system. Do not fax these exemptions without calling the clerical staff! Not identifying where the locking system is being installed within the building.

“HEADS UP OF SOME ISSUES FOR SPECIAL LOCKING SYSTEMS!” LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY “HEADS UP OF SOME ISSUES FOR SPECIAL LOCKING SYSTEMS!” Verify that all signage required by special locking systems are worded and placed correctly. Verify that all signage required by special locking systems comply with the Americans with Disabilities Act - Accessible Guidelines (ADA-AG). Additional signage may be mandated to comply with the requirements of ADA-AG, Section 4.30.

“HEADS UP OF SOME ISSUES FOR SPECIAL LOCKING SYSTEMS!” LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY “HEADS UP OF SOME ISSUES FOR SPECIAL LOCKING SYSTEMS!” 101:7.2.1.6.1 Delayed-Egress Locks(d): On the door adjacent to the release device, there shall be a readily visible, durable sign in letters not less than 1 in. (2.5 cm) high and not less than 1/8 in. (0.3 cm) in stroke width on a contrasting background that reads as follows: “PUSH UNTIL ALARM SOUNDS DOOR CAN BE OPENED IN 15 SECONDS”

“HEADS UP OF SOME ISSUES FOR SPECIAL LOCKING SYSTEMS!” LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY “HEADS UP OF SOME ISSUES FOR SPECIAL LOCKING SYSTEMS!” 101:7.2.1.6.2 c) Access-Controlled Egress Doors: The doors shall be arranged to unlock in the direction of egress from a manual release device located 40 in. to 48 in. (102 cm to 122 cm) vertically above the floor and within 5 ft (1.5 m) of the secured doors. The manual release device shall be readily accessible and clearly identified by a sign that reads as follows: “PUSH TO EXIT” When operated, the manual release device shall result in direct interruption of power to the lock — independent of the access control system electronics — and the doors shall remain unlocked for not less than 30 seconds.

NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview Part IV

NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview Look at the requirements that mandates these systems Understand how to find these requirements in the codes Explain how these requirements affect your fire alarm designs Outline what needs to be provided for code compliance Detail how to submit these systems for plan review

“How does the sprinkler system affect my fire alarm system design?” LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY “What is the difference between an approved automatic sprinkler system and approved supervised automatic sprinkler system?” “How does the sprinkler system affect my fire alarm system design?” “How do I know that the sprinkler is required to be supervised?” “Is it acceptable to chain open the main supply valve as prescribed in NFPA 13 and meet the intent of a supervised system?” “If my fire alarm system is connected to the building sprinkler system, is it then automatically required to transmit off site to a monitoring facility?”

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code 9.7.2.1* Supervisory Signals. Where supervised automatic sprinkler systems are required by another section of this Code, supervisory attachments shall be installed and monitored for integrity in accordance with NFPA 72, National Fire Alarm Code, and a distinctive supervisory signal shall be provided to indicate a condition that would impair the satisfactory operation of the sprinkler system. Monitoring shall include, but shall not be limited to, monitoring of control valves, fire pump power supplies and running conditions, water tank levels and temperatures, tank pressure, and air pressure on dry-pipe valves. Supervisory signals shall sound and shall be displayed either at a location within the protected building that is constantly attended by qualified personnel or at an approved, remotely located receiving facility. (Note: This office’s interpretation of “constantly attended location” is 24 hours a day, 7 days a week and 365 days a year.)

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code 9.7.2.2 Alarm Signal Transmission. Where supervision of automatic sprinkler systems is provided in accordance with another provision of this Code, waterflow alarms shall be transmitted to an approved, proprietary alarm receiving facility, a remote station, a central station, or the fire department. Such connection shall be in accordance with 9.6.1.4. (Therefore based on this requirement the proposed fire alarm system cannot be a local system!)

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code Mandates for supervised automatic sprinkler systems are rarely in the _.3.5 Extinguishing Requirements in occupancy chapters in the Life Safety Code. These requirements are typically given as a code trade-off to extend travel distances, dead-end corridors, or common path of travel. These requirements sometimes are stipulated in minimum construction type limitations in specific occupancy chapters.

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY “Does this mean that I am going to have to look at other sections of the code, other than fire alarm section, to verify that my fire alarm design is code compliant?” Absolutely! The 2000 edition of the Life Safety Code has changed a majority of the sprinkler requirements and sprinkler exceptions to include the term “supervised”. You need to be “code savvy.” Understand other requirements that would mandate a “supervised automatic sprinkler system” - this will affect the design of your fire alarm system.

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code There are requirements in the “core chapters” (Chapters 1- 11) 7.2.12 Areas of Refuge. 7.2.12.1 General. An area of refuge used as part of a required accessible means of egress in accordance with 7.5.4, or used as a part of any required means of egress, shall conform to the following: (1) The general requirements of Section 7.1 (2) The requirements of 7.2.12.2 and 7.2.12.3 Exception: The requirement of 7.2.12.1(2) shall not apply to areas of refuge consisting of stories of buildings protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code There are requirements in the “core chapters” (Chapters 1- 11) 7.5.1.4* Where two exits or exit access doors are required, they shall be placed at a distance from one another not less than one-half the length of the maximum overall diagonal dimension of the building or area to be served, measured in a straight line between the nearest edge of the exit doors or exit access doors. Where exit enclosures are provided as the required exits and are interconnected by not less than a 1-hour fire resistance-rated corridor, exit separation shall be permitted to be measured along the line of travel within the corridor. Where more than two exits or exit access doors are required, at least two of the required exits or exit access doors shall be arranged to comply with the minimum separation distance requirement. The other exits or exit access doors shall be located so that if one becomes blocked, the others shall be available. Exception No. 1: In buildings protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7, the minimum separation distance between two exits or exit access doors measured in accordance with 7.5.1.4 shall be not less than one-third the length of the maximum overall diagonal dimension of the building or area to be served.

NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy 16.2.5.2 No dead-end corridor shall exceed 20 ft (6.1 m), other than in buildings protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7, in which case dead-end corridors shall not exceed 50 ft (15 m). 16.2.5.3 No common path of travel shall exceed 75 ft (23 m), other than for the first 100 ft (30 m) in a building protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.

NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy 16.2.6.2 Travel distance shall meet the following criteria: (1) The travel distance between any room door intended as an exit access and an exit shall not exceed 100 ft (30 m). (2) The travel distance between any point in a room and an exit shall not exceed 150 ft (45 m). (3) The travel distance between any point in a sleeping room and an exit access door in that room shall not exceed 50 ft (15 m). Exception: The travel distance in 16.2.6.2(1) and (2) shall be permitted to be increased by 50 ft (15 m) in buildings protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.

NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy 16.2.11.1 Windows for Rescue. Every room or space normally subject to client occupancy, other than bathrooms, shall have not less than one outside window for emergency rescue that complies with the following: (1) Such windows shall be openable from the inside without the use of tools and shall provide a clear opening of not less than 20 in. (51 cm) in width, 24 in. (61 cm) in height, and 5.7 ft2 (0.53 m2) in area. (2) The bottom of the opening shall be not more than 44 in. (112 cm) above the floor. (3) The clear opening shall allow a rectangular solid, with a width and height that provides not less than the required 5.7-ft2 (0.53-m2) opening and a depth of not less than 20 in. (51 cm), to pass fully through the opening. Exception No. 1: This requirement shall not apply to buildings protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.

NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy 16.3.6 Corridors. Every interior corridor shall be constructed of walls having not less than a 1-hour fire resistance rating in accordance with 8.2.3. Exception No. 2: In buildings protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7, corridor walls shall not be required to be rated, provided that such walls form smoke partitions in accordance with 8.2.4. “What about 16.3.4 - Detection, Alarm, and Communications Systems or 16.3.5 - Extinguishment Requirements?”

NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy 16.3.4 Detection, Alarm, and Communications Systems. 16.3.4.1 General. Day-care occupancies, other than day-care occupancies housed in one room, shall be provided with a fire alarm system in accordance with Section 9.6. 16.3.4.2 Initiation. Initiation of the required fire alarm system shall be by manual means and by operation of any required smoke detectors and required sprinkler systems. (See 16.3.4.5.) 16.3.4.3 Occupant Notification. 16.3.4.3.1 Occupant notification shall be in accordance with 9.6.3. 16.3.4.3.2 Positive alarm sequence shall be permitted in accordance with 9.6.3.4. 16.3.4.4 Emergency Forces Notification. Fire department notification shall be accomplished in accordance with 9.6.4. 16.3.4.5 Detection. A smoke detection system in accordance with Section 9.6 shall be installed in day-care occupancies, other than those housed in one room. Detectors shall be installed on each story in front of the doors to the stairways and in the corridors of all floors occupied by the day-care occupancy. Detectors also shall be installed in lounges, recreation areas, and sleeping rooms in the day-care occupancy.

NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY NFPA 101 - Life Safety Code Chapter 16 - New Day Care Occupancy 16.3.5 Extinguishment Requirements. Any required sprinkler systems shall be in accordance with Section 9.7. Neither of these sections require the automatic sprinkler system to be supervised - this is an example of why you need to have a better understanding of the codes as a whole! Code Savvy!

“How does the sprinkler system affect my fire alarm system design?” LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY “What is the difference between an approved automatic sprinkler system and approved supervised automatic sprinkler system?” Supervised sprinkler systems are monitored for integrity by the fire alarm control panel, which transmit signals (supervisory, trouble and alarm) to a monitoring facility. “How does the sprinkler system affect my fire alarm system design?” The supervisory requirements of NFPA 101 would prohibit the fire alarm signaling system type to be a protected premises or local. “How do I know that the sprinkler is required to be supervised?” Get a copy of the architectural review or ask the design professional.

Waterflow & tamper devices LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY What if the building is not required to have a fire alarm system in accordance with the _.3.4 section of the occupancy chapter, but the building owner wishes to utilize a supervised automatic sprinkler system to enhance an architectural feature, what would be the minimum equipment to satisfy this requirement? The State Fire Marshal’s Office views these “supervised automatic sprinkler systems” as required fire alarm systems not providing occupant notification at the protected premise. Therefore, the following equipment would be required: Control Panel - Listed for the appropriate signaling system type, sprinkler supervision and waterflow. Manual pull station - See 101:9.6.2.5, required when the sprinkler system is down due to maintenance. Waterflow & tamper devices Smoke detector - See 72:1-5.6, required if the control panel is not located in a continuous occupied area. These systems can be submitted on the Fire Alarm Exemption Request Form pursuant to State Fire Marshal Memorandum 99-2.

LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY “Is it acceptable to chain open the main supply valve as prescribed in NFPA 13 and meet the intent of a supervised system?” No! The requirements of 101:9.7.2.1 stipulates that the where a supervised automatic sprinkler system is required by another section of the code, the supervisory attachments shall be installed and monitored in accordance with NFPA 72. “If my fire alarm system is connected to the building sprinkler system, is it then automatically required to transmit off site to a monitoring facility?” No! Only if other sections of the code require the sprinkler system to be supervised.