ispark 'i' Explosionprotection made by PTB:

Slides:



Advertisements
Similar presentations
Process Management System Economical Automation with Standard Software
Advertisements

RP Designs Semi-Custom e-Commerce Package. Overview RP Designs semi- custom e-commerce package is a complete website solution. Visitors can browse a catalog.
ITU WORKSHOP ON STANDARDS AND INTELLECTUAL PROPERTY RIGHTS (IPR) ISSUES Session 5: Software copyright issues Dirk Weiler, Chairman of ETSI General Assembly.
Paolo Gemma, Senior Expert, Huawei
1 IEC standards for Equipment used in Environments for Explosive Atmospheres: a tool to enhance safety; business continuity and open international markets.
Available & Effective charging solution for electric cars Advanced mobile charging systems.
THE DEVICE, THE FEATURES & Centralized Management System (CMS)
Independent Laboratory Testing PART 6 Regulations Wayne Colley Electrical Safety Division Electrical Engineer.
Design Rule Generation for Interconnect Matching Andrew B. Kahng and Rasit Onur Topaloglu {abk | rtopalog University of California, San Diego.
Sector Initiative on Equipment for Explosive Environments (SIEEE) Melbourne 02. September 2009 Status Report: 1.Kick off meeting 2007 in Geneva, Presentations.
1 Overview about the PTB Ex Proficiency Testing Scheme - Status Report - Lisa Zater, Tim Krause, Uwe Klausmeyer 26 th of August 2014 ExTAG WG 10.
Sampling Mathsfest Why Sample? Jan8, 2003 Air Midwest Flight 5481 from Douglas International Airport in North Carolina stalled after take off, crashed.
Mr. Harethe El Ouadhane IEC member for IEC MT14. |Infrastructure Business | Germany | Test Engineer & Expert (Internal Arc, Making, Breaking.
Using Between-Subjects and Within-Subjects Experimental Designs
Testing- and Calibration Technology Calibration Software EasyCal Pressure and Temperature Measurement.
Electrical Circuits. Drawing Circuits 1) A cell, a bulb and a switch “in series” 2) A battery of cells, a switch and two bulbs in series.
German calibration lab association
Blabo® Automated Tank Cleaning ExxonMobil 2009 Article Electrical standards Designed for operation in hazardous areas. Constructed for zone 1, and some.
Manfred Kochsiek Wilfried Schulz Physikalisch-Technische Bundesanstalt Braunschweig und Berlin Modernisation of Legal Metrology in Germany.
S3: Module D Physikalisch-Technische Bundesanstalt Session 3: Conformity Assessment Module D Peter Ulbig, Harry Stolz Belgrade, 31 October.
Basics of OHSAS Occupational Health & Safety Management System
Fieldbus 1 FISCO. Fieldbus Certified Transmitter : Intrinsically safe IIC/Group A T4 Ui : 30V Ii : 100mA Ci : 0.01  F Li : 100  H C c : 0.12  F L c.
A Global Approach for Ex-Products – IECEx UNECE WP.6 Geneva June 2006 Proposal for a new activity: “International legal requirements for explosion.
Introduction to MCMC and BUGS. Computational problems More parameters -> even more parameter combinations Exact computation and grid approximation become.
Ways for Improvement of Validity of Qualifications PHARE TVET RO2006/ Training and Advice for Further Development of the TVET.
Human Computer Interaction
EASI a free web database application for collecting and managing monitoring records.
Safety management software for state and local highway agencies: –Improves identification and programming of site- specific highway safety improvements.
Sub-Cycle Fault Location in Electrical Systems: IP and Current Status of Technology Charles Kim Electrical and Computer Engineering Howard.
Key Stage 3 National Strategy © Crown copyright 2004 Constructing and solving linear equations in Year 7.
M O V E – Management – Of – Vibration – Emissions/Exposure.
Electrical Fire in Terminal Room at Collider-Accelerator Department Relay-Fire Investigation Committee
9-1 Using SafetyAnalyst Module 4 Countermeasure Evaluation.
©2010 John Wiley and Sons Chapter 3 Research Methods in Human-Computer Interaction Chapter 3- Experimental Design.
Understanding Sampling
Task 1B Multiple Choice Quiz. Quiz Link Part 1: Z Z Part2:
National Legislation on in- service inspections and the PED.
CABLING SYSTEM WARRANTY REGISTRATION. PURPOSE OF CABLING REGISTRATION.
94/9 requires an EC Type examination certificate Annex III Certificate and a QA-Notification (production audit Annex IV/VI/VII) Manufacturers need for.
Lecture №4 METHODS OF RESEARCH. Method (Greek. methodos) - way of knowledge, the study of natural phenomena and social life. It is also a set of methods.
SAFETY AND INFRASTRUCTURE REQUIREMENTS FOR TEL-2 INSTALLATION IN THE LAB Paolo Magagnin (BE-BI-ML) 24 – April
Update on Modeling Activities Gun Simulation Optimization Using Genetic Algorithms.
Safety of Electrical Products and the IEC Conformity Assessment Schemes A presentation to Regional Workshop in Conjunction with COPANT May, 2004.
Standards ? What other Standards? Eddie Welsh EQA Assessment Manager.
Research proposal (Lecture 3) Dr.Rehab F Gwada. Objectives of the Lecture The student at the end of this lecture should Know Identify Target Population.
Network and Server Basics. Learning Objectives After viewing this presentation, you will be able to: Understand the benefits of a client/server network.
COMPUTER CRIMES Presented by THABO.
Basic requirements on area dosemeters
PTB Ex Proficiency Testing Scheme
Overview 1. Approach to IS assessment
U.S. participation in IECEx Scheme
Ron Sinclair Managing Director – Baseefa
IECEx Industry Seminar Integrating IECEx and ATEX for Europe
IECEE Factory Surveillance Service (FSS)
ATEX fans st ATEX.
QPS EVALUATION SERVICES INC.
Sector Initiative on Equipment for Explosive Environments (SIEEE)
Key Takeaways from Post-Seminar Workshop
Online Testing - System Readiness Tools
Electrical Safety Standards
Experimental Design.
Experimental Design.
The Role of the Communications Unit Leader
11C Line of Best Fit By Eye, 11D Linear Regression
MECH 3550 : Simulation & Visualization
On-Line Certificate System
presented by Paul Moliski Director of Accreditation
Tri-lateral comparison CMI-PTB-VNIIR to evaluate bell provers
ประกาศกระทรวงอุตสาหกรรม ฉบับที่ 5292 (พ.ศ. 2562)
Presentation transcript:

ispark 'i' Explosionprotection made by PTB: a method for computer aided assessment and design of intrinsically safe circuits with Lo and Co - Ik_000.PPT Physikalisch-Technische Bundesanstalt Braunschweig und Berlin

ispark 'i' User target group Operators of sites requiring explosion protection Manufacturers of explosion protected apparatus Third party experts Testing and certification bodies ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 104

ispark 'i' What does the method provide? On the base of preset electrical source data, intrinsic safety of the source itself is checked and maximum permissible capacitances Co and inductances Lo are determined, specialities of cable reactances are picked up, granting some more headspace for site installations ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 100

ispark 'i' How does it work? Systematic investigation of experimental ignition testing results, using the standardized spark test apparatus, yielded characteristic electrical and calorical parameters. A computer program uses these parameters for a model based calculation ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 110

ispark 'i' Competing methods practical use of the standardized spark test apparatus analytical evaluation against reference ignition data according to IEC 60079-11 ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 114

'i' Disadvantages of practically using the standardized spark test apparatus the standardized spark test apparatus itself, including appropriate infrastructure, is required usage is prone to errors and often lengthy experimental results are dependable only if statistically analysed, the standardized type test reveals no real significance ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 119

ispark 'i' Drawbacks using reference ignition data reference ignition data are available only for some very simple sources and circuits certain effects are not comprised by those data, for example non linearities and cables usage is prone to error and often lengthy reference ignition data often reveal quantita-tive contradictions ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 121

ispark 'i' Advantages using ispark arbitrary electrical sources can be assessed circuits comprising both, inductances AND capacitances as well as cables, are included the application is simpliest to use reproducibility and coherence are very high ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 140

ispark 'i' What kind of data must be preset? zone 0,1 resp. zone 2 (safety factor 1,5 resp. 1,0) gasgroup type of circuit including quantities for multiple sources parallel and/or serial con-nection type of freewheeling if any Cable data: L‘, C‘ and R‘ ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 150

ispark 'i' What kind of data are reported? summary of preset data if the source is determined intrinsically safe, a list of maximum Lo/Co pairs which are per-missible concurrently within the circuit if inclusion of cables is claimed, additionally to Co/Lo pairs, a maximum cable length extra allowed ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 160

ispark 'i' What's needed to use ispark? personnel for type in electrical data and handle the reported results a common standard PC running at least Win2000 (upto Win7_64) the program package ispark itself a license granted by PTB (royalty is € 2560.-, halved for acknowledged certification bodies) Note: License includes all subsequent impro-vements/versions of ispark without additional charge ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 180

'i' ispark‘s status today? in PTB using ispark is the first choice when assessing circuits for certification about one-third of European Notified Bodies have a license for ispark as well as one-third of IECEx participants weaknesses of standardized experimental type testing nowadays are found more and more - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 180

ispark 'i' For further information please contact Martin Krämer, Dipl.-Ing., Ag 3.62 Physikalisch-Technische Bundesanstalt Bundesallee 100 38116 Braunschweig, DEUTSCHLAND tel: (+49) 0531/592-3525 fax: (+49) 0531/592-3605 email: martin.kraemer@ptb.de ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 190