Programmable AC Source 61500/61600 Series

Slides:



Advertisements
Similar presentations
~ Mini Programmable DC Power Supply ~. mPP Series :
Advertisements

DEWETRON - Power Product Line
Principles & Applications Small-Signal Amplifiers
Interharmonics IEEE T&D Show New Orleans Panel Session PN13 Non-periodic Currents: Causes,
UPS Topologies and Multi-Module Configurations
Chapter 12 Power Amplifiers
Chapter 14 Feedback and Oscillator Circuits
Colombo, Sri Lanka, 3-4 October 2013 ITU-T L.1200 Direct current power feeding interface up to 400 V at the input to telecommunication and ICT equipment.
Druck- und Temperaturmesstechnik Testing Procedure MH-2 Mobile Hydraulic Testing Procedure 1 Pressure Transmitter MH-2.
SWITCH-MODE POWER SUPPLIES AND SYSTEMS Silesian University of Technology Faculty of Automatic Control, Electronics and Computer Sciences Ryszard Siurek.
The World Leader in High Performance Signal Processing Solutions Analog Video Transmission over Unshielded Twisted Pair (UTP) March 2011.
SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead.
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
CL100D series DSP controlled Uninterruptible power supplies.

Beckett Energy Systems
Chapter 11 AC Power Analysis
High Frequency Distortion in Power Grids due to Electronic Equipment Anders Larsson Luleå University of Technology.
LED Driver Load A Introduction Working on Better Solutions.
SITOP power facets A&D SE PS SITOP power Automation and Drives SITOP power flexi The power pack handles it all - from 3 to 52V SITOP power.
Intermediate Course (4) Transmitters Karl Davies East Kent Radio Society EKRS 1.
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
Mike Thornton National Sales Manager
TS01 Klystron Modulator Minh Nguyen May 20, 2014 Beam Voltage Stability Improvements.
Fisica Generale - Alan Giambattista, Betty McCarty Richardson Copyright © 2008 – The McGraw-Hill Companies s.r.l. 1 Chapter 21: Alternating Currents Sinusoidal.
Practical Considerations for Digital Design
1 Chapter 31--Examples. 2 Problem You want the current amplitude though a 0.45 mH inductor (part of the circuitry for a radio receiver) to be 2.6 mA when.
CommentaryVideo Hi, my name is Edward Guillergan and I’m one of AMETEK Programmable Power’s Applications Engineers. I’m here to provide an overview of.
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
©2004 Fluke Corporation Introduction to Motor Troubleshooting 1 Introduction to Motor Troubleshooting.
MODULAR SMPS POWER PLANT
LP33 Series UPS kVA 400Vac/CE
EUT 1040 Lecture 10: Programmable Logic Controllers.
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
POWER SUPPILES LECTURE 20.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
 Distortion – the alteration of the original shape of a waveform.  Function of distortion analyzer: measuring the extent of distortion (the o/p differs.
DC POWER SUPPLY. Maeil Power Co.,Ltd is a one of leading supplier of switching power supply. The company design and manufacture quality products that.
CLASS B AMPLIFIER 1. 2 In class B, the transistor is biased just off. The AC signal turns the transistor on. The transistor only conducts when it is turned.
General Licensing Class G7A – G7C Practical Circuits Your organization and dates here.
150W Inverter - an optimal Presenter: Dr Gawie van der Merwe design in solar home systems.
Numerical algorithms for power system protection Prof. dr. sc. Ante Marušić, doc. dr. sc. Juraj Havelka University of Zagreb Faculty of Electrical Engineering.
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
POWER QUALITY.
Understanding Power Quality Monitoring
1 Power Quality EKT 451 CHAPTER 8. 2 Introduction Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 11 Amplifiers: Specifications.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
Introduction  Utilities transmit electricity over power lines into home as an alternating current (AC) wave.  This is how power travels through wiring.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Copyright© 2005 Avaya Inc. All rights reserved Avaya UPS Training powerware.com/avaya.
Power supply.
The Working Theory of an RC Coupled Amplifier in Electronics.
J.PRAKASH.  The term power quality means different things to different people.  Power quality is the interaction of electronic equipment within the.
A+ Computer Repair Lesson 9 Problems Causing Power Events.
Power Quality Any power problem manifested in voltage, current or frequency deviation that results in failure or misoperation of customer equipment. IEEE.
Auxiliary power supply (APS) Hossein Harimi 2014
Introduction to Global AC Power
N4L Ltd. (UK) EMC IEC61000 COMPLIANT TEST SOLUTIONS
UPS Sales Training Book Angela Hsu
Fundamentals of Harmonics
IMPEDENCE - SOURCE INVERTER FOR MOTOR DRIVES
بِسمِ اللهِ الرَحمنِ الرَحیم
General Licensing Class
آشنائی با کوره های قوس الکتريکی DC و مقايسه آن با کوره های AC
Chapter 11 Amplifiers: Specifications and External Characteristics
PowerLogic™ offer for the basic metering market
Presentation transcript:

Programmable AC Source 61500/61600 Series CHROMA ATE INC. Programmable AC Source 61500/61600 Series Product Manager: Galen Chou

Chroma AC Source Family 3 3

Outline 1. What is programmable AC source ? 2. What is user’s need ? 3. What do they test with AC source ? 4. Functions of Chroma AC sources 3 3

A Primitive AC Source 1. Not easy to setup 2. Inconvenient to use 3. No protection Power Meter Function Generator Transformer Power Amplifier C C 3 3

AC Source Structure AC Input Input Output Stage Waveform Generator, Power Output Waveform Generator, Control and Measurement Units User Interface AC Output User 3 3

AC Source Power Stages Linear type, a transformer on output, high impedance A/D Power Stage D/A Line Input AC Output A transformer on input, weight is heavy A/D Power Stage D/A Line Input AC Output 3 3

Chroma’s AC Source Advantage Power Stage D/D D/A Line Input AC Output 1. No low -frequency transformer, lighter than others 2. Standard PFC input, save power and less interference to main 3. No transformer on output, low impedance 3 3

Chroma’s AC Source Advantage Output impedance: Zo = Ro + Lo High impedance: Voltage drop, Current inhibit, High frequency current filter, not good for testing IEC61000-3-2 The lab doesn’t use the AC source with a transformer on output. AC Source Zo 3 3

What is users’ need ? Basic : (61500/61600 Series) 1. Clean, pure and stable sine waveform AC power 2. Measurement : Power, voltage, current Monitor 3. Line regulation test (90 – 264V, 47 - 63Hz) 4. Simulation mains for all power systems in the world 230V/50Hz, 120V/60Hz, 100V/50Hz … 5. Auto-test (Remote control) 3 3

What is users’ need ? How much power of AC source dose user need? Example: Test 300W (output) power supply 1. Ask the efficiency: Input power = 300W/0.8 = 375W 2. Ask the Power Factor: Input VA = 375/0.75 = 500VA 3. Ask if test OPT: Max VA = 500VA x 1.3 = 650VA 4. Ask the low line : Max input current : 650VA/90V = 7.22A At least, the customer needs 61502/61602 (1KW) 5. Ask the inrush current: If 45Apeak is needed at 230V, then he needs 61504/61604 (2KW) 3 3

Additional : (61500/61600 series) What is users’ need ? Additional : (61500/61600 series) Power Turn ON/OFF phase angle Setting 90° Turn ON for inrush current test. 2. Inrush Current Measurement (Delay time, Interval) Voltage/Frequency Slew Rate Setting a. Operate for range scanning (90V-264V 或 47H – 63Hz ) b. Raising the voltage gradually, power on UUT with less inrush current 4. Voltage/Frequency Save and Recall ( One-key Recall) 3 3

61500/61600 Softpanel Function Auto Run: Programming for long time test (On/Off or Burn-in) 3 3

Report Function : Data Recording stored in a File 61500/61600 Softpanel Function Report Function : Data Recording stored in a File 3 3

What else is users’ need ? Only testing the specification of input power is not enough to verify the UUT. Simulating the power like real world is the way to get better quality and stability. Advance Test : (61500 series only) 1. Transient Voltage Simulation 2. Distorted Waveform Simulation 3 3

Transient Output Different kind of transient output: Surge Sag Frequency Variation Cycle Dropout 3 3

Influence of Transient Output Example : Power supply of DVD player +5V to memory +3.3V to CPU +12V to driver When cycle dropout occurs, output voltage will drop then back to normal level. The machine might shut down because of improper dropping rate of voltage. (Memory might be reset, but CPU might work as usual. ) 3 3

Example for Transient Output Test Cycle Drop Out Test Brown Out Test 3 3

Regulation for Transient Output IEC 61000-4-11 : Voltage dips, short interruptions and voltage variation immunity tests dip short voltage variation 100%UT 0%UT 40%UT t (sec) 3 3

Regulation for Transient Output IEC 61000-4-14 : Voltage fluctuation immunity test 60s Un Un - 10%Un Un + 10%Un 5s±0.5s 5 periods 2s±0.2s ΔU 3 3

Regulation for Transient Output IEC 61000-4-28 : Variation of power frequency immunity test tp f1 f1-Δf f1+Δf 120s 60s f1 tp f1+Δf 3 3

61500 AC Source Functions for Transient Output LIST Mode: Program output waveform sequence by sequence 3 3

61500 AC Source Functions for Transient Output PULSE Mode: Insert a waveform into normal voltage 3 3

61500 AC Source Functions for Transient Output STEP Mode : Change from an initial voltage to destination step by step 3 3

Transient Output with High Voltage A transient high voltage of main will damage the electrical products. (It happens usually in China and India.) Many companies have asked it as a standard test item. Chroma solution: Model 6560, or 2 units connecting in series…. 400V/0.5sec 220V 3 3

Transient Output with High Voltage 2 units of AC Source with synchronizing signal: Use 3-phase Mode, 61500/61600 as the Master, 61500 as the Slave. 220V with 400V/0.5s transient Master: Fixed Mode 220V L N UUT L N Slave: List Mode 180V/0.5 sec 3 3

2 Units of AC Source Application The voltage resonance happens when EMI filter plugs into the main. Using AC Source to simulate the disturbance effect. 3 3

Combine 3 Units of AC Sources Chroma 61500/61600 AC Source : 3 units can be combined to a 3-phase AC Power Source (1 Master, 2 Slave units with setting the phase 120° and 240 °) 3 3

Distorted Waveform Io Zo Fr = Power Plant Power Network Nonlinear load pollutes the mains with distortion current. Io Pure V Distorted V C L Resonance Point Frequency Zo 2Π √LC 1 Fr = 3 3

Distorted Waveform Different kind of distorted waveform: Harmonic Distortion Interharmonic Distortion Clipped Sine Waveform Low frequency drift 3 3

Regulation for Distorted Waveform IEC 61000-4-13 : Harmonics, Interharmonics including mains signaling at AC power port immunity tests Sweep Flat Curve Over Swing 3 3

Influence of Distorted Waveform Comparing With/Without harmonic component: Same UUT, 2.46A 3.015A, 22% increase 3 3

Influence of Distorted Waveform Comparing With/Without interharmonic component: Same UUT, 0.83A 1.3A , 57% increase 3 3

Influence of Distorted Waveform With voltage interharmonics component: Fi=30.85Hz, level =7% abnormal current waveform PWM unstable 3 3

61500‘s Functions for Distorted Waveform SYNTHESIS : Edit harmonic components (Amplitude & Phase) of 40 orders to synthesize a new waveform. (50/60Hz) 3 3

61500‘s Functions for Distorted Waveform INTERHARMONICS : Add a sweeping frequency component (0.01Hz – 2400 Hz) on a normal voltage. It helps to find the resonance point, or the weak point of the UUT. 3 3

61500‘s Functions for Distorted Waveform WAVEFORM EDITOR : Edit waveform by harmonic orders on softpanel, send the data and save to User Waveform of AC Source. It can be used on every frequency but less accuracy. 3 3

Application for AC Power Distortion With the customers or facilities being oversea, the input power problem can’t be solved in a short time. Solution: 1. Measure the harmonic components by Power Analyzer on facility. 2. Re-build the waveform by SYNTHESIS function of AC Source, RD or QC can test it on the lab. . 3 3

Application for AC Power Distortion Measure Harmonic components Re-build Waveform 3 3

DC Component of AC Power It contains DC component on some AC power sources, like UPS. 1. Current unbalance. Input rectifier may be damaged. 2. Input transformer saturation (DC current) Using AC Source AC+DC mode to simulate. Without DC component With DC component 3 3

DC Output Application of AC Power Use optional unit A615008, DC Noise Filter, when output DC voltage. It can help to decrease the noise, and increase the stability. Connection Method: 3 3

Analog Control for AC Source 1. DC Level Control Mode: Use an external DC voltage to control the amplitude of output AC voltage. Frequency is set on AC Source. 424Vdc 212Vdc Output V External input V 10Vdc 300V rms @300V rang 150V rms @150V rang 3 3

Analog Control for AC Source 2. AC Amplifier Mode: Send an external signal to AC source and amplify it as the output waveform, just like the user‘s need. External input V Output V 10 Vdc 424 Vdc @300V rang 212 Vdc @150V rang -424 Vdc @300V rang -212 Vdc @150V rang -10 Vdc 3 3

TTL signals of AC Source 1. AC_ON : Up to high level when AC source output. Counting time interval between power-on and normal operation. 2. Synchronize (Transient) : Send a pulse signal when output change. For external trigger or system integration 3 3

TTL signals of AC Source 3. Fault : TTL level becomes low when protection occur. For notice or system integration 4. Remote_Inhibit : Inhibit the output when the signal becomes low. External control for system integration. Trigger Live 3 3

Regulation Test AC Source offers a pure and stable voltage to UUT. EN61000-3-2 Limits for harmonic current emissions EN61000-3-3 Limitation of voltage fluctuations and flicker Haefely use Chroma AC source as a standard source. 3 3

Do you have Questions? For more information on the Chroma 61500 / 61600 Series AC Power Sources or if you would like to purchase one of these models please contact your sales engineer at ValueTronics. 800-552-8258 or 847-468-8258 www.valuetronics.com 3 3