Dynamic Behavior of Closed-Loop Control Systems

Slides:



Advertisements
Similar presentations
Dynamic Behavior of Closed-Loop Control Systems
Advertisements

ERT 210 Process Control & dynamics
Chapter 10 Stability Analysis and Controller Tuning
ERT 210 Process Control & dynamics
CHE 185 – PROCESS CONTROL AND DYNAMICS
Chapter 8 Root Locus <<<4.1>>>
CHE 185 – PROCESS CONTROL AND DYNAMICS
Control System Design Based on Frequency Response Analysis
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Chapter Summer 2. Comparator 3. Block Blocks in Series
Dynamic Behavior and Stability of Closed-Loop Control Systems
Transient and steady state response (cont.)
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Dynamic Behavior and Stability of Closed-Loop Control Systems
Chapter 11 1 Closed-Loop Responses of Simple Control Systems In this section we consider the dynamic behavior of several elementary control problems for.
Chapter 8: System Stability.
Digital Control Systems Stability Analysis of Discrete Time Systems.
Chapter 6 – The Stability of Linear Feedback Systems
Feedback Controllers Chapter 8.
Chapter 7 PID Control.
Automatic Control Theory-
Anis Atikah Ahmad CHAPTER 11: Dynamic Behaviour & Stability of Closed-Loop Control Systems Anis Atikah Ahmad
Transfer Functions Chapter 4
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Control Engineering Lecture# 10 & th April’2008.
Open and closed loop transfer functions. BIBO stability by M. Miccio rev. 3.5 of March 12, 2015.
Chapter 7 Stability and Steady-State Error Analysis
Chapter 11 1 Stability of Closed-Loop Control Systems Example 11.4 Consider the feedback control system shown in Fig with the following transfer.
سیستمهای کنترل خطی پاییز 1389 بسم ا... الرحمن الرحيم دکتر حسين بلندي - دکتر سید مجید اسما عیل زاده.
Chapter 8 Feedback Controllers 1. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control.
Chapter 6 Analysis of Feedback Control Systems Prof. Shi-Shang Jang Chemical Engineering Department National Tsing-Hua University Hsin Chu, Taiwan June,
Subsea Control and Communications Systems
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Lec 7. Higher Order Systems, Stability, and Routh Stability Criteria Higher order systems Stability Routh Stability Criterion Reading: 5-4; 5-5, 5.6 (skip.
Lecture 7 Poles and Zeros Stability. Transfer Function Models General Representation wh where z i are the zeros p i are the poles n ≥ m to have a physically.
Modern Control System EKT 308 Steady-State and Stability.
In The Name of Allah The Most Beneficent The Most Merciful
CHAPTER VI BLOCK DIAGRAMS AND LINEARIZATION
1 Time Response. CHAPTER Poles and Zeros and System Response. Figure 3.1: (a) System showing input and output; (b) Pole-zero plot of the system;
Modern Control System EKT 308
Stability Analysis . A system is BIBO stable if all poles or roots of
ERT 210/4 Process Control & Dynamics DYNAMIC BEHAVIOR OF PROCESSES :
TRANSFER FUNCTION Prepared by Mrs. AZDUWIN KHASRI.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Dr. Tamer Samy Gaafar Lec. 2 Transfer Functions & Block Diagrams.
Automatic Control Theory CSE 322
Anis Atikah Ahmad CHAPTER 11: Dynamic Behaviour & Stability of Closed-Loop Control Systems Anis Atikah Ahmad
Chapter 11 1 ERT 210/4 Process Control CHAPTER 11 DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS.
1 PID Feedback Controllers PID 反馈控制器 Dai Lian-kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
Intelligent Robot Lab Pusan National University Intelligent Robot Lab Chapter 6. TRANSIENT RESPONSE -- STABILITY Pusan National University Intelligent.
General Stability Criterion Most industrial processes are stable without feedback control. Thus, they are said to be open-loop stable or self-regulating.
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Automatic Control Theory CSE 322
Laplace Transforms Chapter 3 Standard notation in dynamics and control
Transfer Functions Chapter 4
Digital and Non-Linear Control
Control Systems (CS) Lecture-17 Routh-Herwitz Stability Criterion
Automatic Control Theory CSE 322
Learning Outcomes After completing this ppt the student will be able to: Make and interpret a basic Routh table to determine the stability of a system.
Effects of Zeros and Additional Poles
CHAPTER VI BLOCK DIAGRAMS AND LINEARIZATION
Dynamic Behavior and Stability of Closed-Loop Control Systems
Time-Domain Analysis of Control Systems (3)
UNIVERSITI MALAYSIA PERLIS SCHOOL OF ELECTRICAL SYSTEM ENGINEERING
Chapter 6 – The Stability of Linear Feedback Systems
Stability of Closed-Loop Control Systems
Feedback Control Systems (FCS)
Proportional Control and Disturbance Changes
Chapter 6. STABILITY Good relationships nurture you. They help you find yourself and who you are. I don’t mean just relationships with boys or men. Relationships.
Time Response, Stability, and
Presentation transcript:

Dynamic Behavior of Closed-Loop Control Systems Chapter 11

Chapter 11

Next, we develop a transfer function for each of the five elements in the feedback control loop. For the sake of simplicity, flow rate w1 is assumed to be constant, and the system is initially operating at the nominal steady rate. Process In section 4.1 the approximate dynamic model of a stirred-tank blending system was developed: Chapter 11 where

Chapter 11

The symbol denotes the internal set-point composition expressed as an equivalent electrical current signal. is related to the actual composition set point by the composition sensor-transmitter gain Km: Chapter 11

Chapter 11 Current-to-Pressure (I/P) Transducer Control Valve The transducer transfer function merely consists of a steady-state gain KIP: Chapter 11 Control Valve As discussed in Section 9.2, control valves are usually designed so that the flow rate through the valve is a nearly linear function of the signal to the valve actuator. Therefore, a first-order transfer function is an adequate model

Chapter 11 Composition Sensor-Transmitter (Analyzer) Controller We assume that the dynamic behavior of the composition sensor-transmitter can be approximated by a first-order transfer function, but τm is small so it can be neglected. Controller Suppose that an electronic proportional plus integral controller is used. Chapter 11 where and E(s) are the Laplace transforms of the controller output and the error signal e(t). Kc is dimensionless.

Chapter 11

Chapter 11 1. Summer 2. Comparator 3. Block Blocks in Series are equivalent to...

Chapter 11

Chapter 11 “Closed-Loop” Transfer Functions Indicate dynamic behavior of the controlled process (i.e., process plus controller, transmitter, valve etc.) Set-point Changes (“Servo Problem”) Assume Ysp  0 and D = 0 (set-point change while disturbance change is zero) Chapter 11 (11-26) Disturbance Changes (“Regulator Problem”) Assume D  0 and Ysp = 0 (constant set-point) (11-29) *Note same denominator for Y/D, Y/Ysp.

Chapter 11

Chapter 11

Chapter 11 Figure 11.16 Block diagram for level control system.

Chapter 11

Chapter 11

Chapter 11

EXAMPLE 1: P.I. control of liquid level Block Diagram: Chapter 11

Chapter 11 Assumptions 1. q1, varies with time; q2 is constant. 2. Constant density and x-sectional area of tank, A. 3. (for uncontrolled process) 4. The transmitter and control valve have negligible dynamics (compared with dynamics of tank). 5. Ideal PI controller is used (direct-acting). Chapter 11 For these assumptions, the transfer functions are:

Chapter 11 The closed-loop transfer function is: (11-68) Substitute, (2) Chapter 11 Simplify, (3) Characteristic Equation: (4) Recall the standard 2nd Order Transfer Function: (5)

To place Eqn. (4) in the same form as the denominator of the T.F. in Eqn. (5), divide by Kc, KV, KM : Comparing coefficients (5) and (6) gives: Chapter 11 Substitute, For 0 <  < 1 , closed-loop response is oscillatory. Thus decreased degree of oscillation by increasing Kc or I (for constant Kv, KM, and A). unusual property of PI control of integrating system better to use P only

Stability of Closed-Loop Control Systems Chapter 11

Chapter 11 Proportional Control of First-Order Process Set-point change: Chapter 11

Chapter 11 Set-point change = M Offset = See Section 11.3 for tank example

Chapter 11 Closed-Loop Transfer function approach: First-order behavior closed-loop time constant (faster, depends on Kc)

Chapter 11

Chapter 11 General Stability Criterion Most industrial processes are stable without feedback control. Thus, they are said to be open-loop stable or self-regulating. An open-loop stable process will return to the original steady state after a transient disturbance (one that is not sustained) occurs. By contrast there are a few processes, such as exothermic chemical reactors, that can be open-loop unstable. Definition of Stability. An unconstrained linear system is said to be stable if the output response is bounded for all bounded inputs. Otherwise it is said to be unstable. Chapter 11

Chapter 11 Effect of PID Control on a Disturbance Change For a regulator (disturbance change), we want the disturbance effects to attenuate when control is applied. Consider the closed-loop transfer function for proportional control of a third-order system (disturbance change). Chapter 11 is unspecified Kc is the controller function, i.e., .

Let If Kc = 1, Chapter 11 Since all of the factors are positive, , the step response will be the sum of negative exponentials, but will exhibit oscillation. If Kc = 8, Corresponds to sine wave (undamped), so this case is marginally stable.

If Kc = 27 Since the sign of the real part of the root is negative, we obtain a positive exponential for the response. Inverse transformation shows how the controller gain affects the roots of the system. Chapter 11 Offset with proportional control (disturbance step-response; D(s) =1/s )

Therefore, if Kc is made very large, y(t) approaches 0, but does not equal zero. There is some offset with proportional control, and it can be rather large when large values of Kc create instability. Integral Control: Chapter 11 For a unit step load-change and Kc=1, no offset (note 4th order polynomial)

Chapter 11 PI Control: no offset adjust Kc and I to obtain satisfactory response (roots of equation which is 4th order). Chapter 11 PID Control: (pure PID) No offset, adjust Kc, I , D to obtain satisfactory result (requires solving for roots of 4th order characteristic equation). Analysis of roots of characteristic equation is one way to analyze controller behavior

Rule of Thumb: Closed-loop response becomes less oscillatory and more stable by decreasing Kc or increasing tI . General Stability Criterion Consider the “characteristic equation,” Note that the left-hand side is merely the denominator of the closed-loop transfer function. Chapter 11 The roots (poles) of the characteristic equation (s - pi) determine the type of response that occurs: Complex roots  oscillatory response All real roots  no oscillations ***All roots in left half of complex plane = stable system

Chapter 11 Figure 11.25 Stability regions in the complex plane for roots of the characteristic equation.

Chapter 11 Stability Considerations Feedback control can result in oscillatory or even unstable closed-loop responses. Chapter 11 Typical behavior (for different values of controller gain, Kc).

Chapter 11 Roots of 1 + GcGvGpGm (Each test is for different value of Kc) (Note complex roots always occur in pairs) Figure 11.26 Contributions of characteristic equation roots to closed-loop response.

Chapter 11

Chapter 11 Routh Stability Criterion Characteristic equation (11-93) Where an >0 . According to the Routh criterion, if any of the coefficients a0, a1, …, an-1 are negative or zero, then at least one root of the characteristic equation lies in the RHP, and thus the system is unstable. On the other hand, if all of the coefficients are positive, then one must construct the Routh Array shown below:

Chapter 11 For stability, all elements in the first column must be positive.

Chapter 11 The first two rows of the Routh Array are comprised of the coefficients in the characteristic equation. The elements in the remaining rows are calculated from coefficients by using the formulas: (11-94) Chapter 11 (11-95) . (11-96) (11-97) (n+1 rows must be constructed; n = order of the characteristic eqn.)

Chapter 11 Application of the Routh Array: Characteristic Eqn is We want to know what value of Kc causes instability, I.e., at least one root of the above equation is positive. Using the Routh array, Conditions for Stability The important constraint is Kc<8. Any Kc 8 will cause instability.

Figure 11.29 Flowchart for performing a stability analysis. Chapter 11

Chapter 11 Additional Stability Criteria 1. Bode Stability Criterion Ch. 14 - can handle time delays 2. Nyquist Stability Criterion Ch. 14 Chapter 11

Direct Substitution Method Imaginary axis is the dividing line between stable and unstable systems. Substitute s = jw into characteristic equation Solve for Kcm and wc (a) one equation for real part (b) one equation for imaginary part Example (cf. Example 11.11) characteristic equation: 1 + 5s + 2Kce-s = 0 (11-101) set s = jw 1 + 5jw + 2Kce-jw = 0 1 + 5jw + 2Kc (cos(w) – j sin(w)) = 0 Chapter 11

Chapter 11 Direct Substitution Method (continued) Re: 1 + 2Kc cos w = 0 (1) Im: 5w – 2Kc sin w = 0 (2) solve for Kc in (1) and substitute into (2): Chapter 11 Solve for w: wc = 1.69 rad/min (96.87°/min) from (1) Kcm = 4.25 (vs. 5.5 using Pade approximation in Example 11.11)

Chapter 11 Previous chapter Next chapter