Producing an X-ray Exposure

Slides:



Advertisements
Similar presentations
Technique Guidance Systems
Advertisements

Chapter 11 Prime Factors.
CHAPTER 6 THE X-RAY BEAM SPECIFIC OBJECTIVES NOTED IN THIS POWER POINT BEGIN ON PAGE
Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
The X-Ray Tube Bushong Ch 7.
Chapter’s 2, 3. & 4 By Garland Fisher
Primary Exposure Factors IV
Radiographic Quality Chapter 5.
Chapter 7 Radiographic Image Formation and Exposure Factors.
E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
X-ray tube and detection of X-rays Lecture 5. Reminder: The rough schematics of an X-ray tube filament cathod target anode photon flux e-e- electron kinetic.
ACVR Artifacts Artifacts of Diagnostic Radiology
Analyzing the Image Density. Density Overall blackening of the image.
354 Chapt. 6 X-ray Tube TWO Primary components – cathode and anode Tube must be supported: Ceiling/floor mounted/C-arm, etc. – SID’s – Detents (center.
Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.
X-RAY TUBE & EXPOSURES INVERSE SQ LAW CIRCUITRY
Resident Physics Lectures
Medical Imaging X-Rays I.
Factors affecting the X-Ray output
X-Ray Production & Emission
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Production Chapter 8.
The X-ray Imaging System
X-Ray Production & Emission
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
P RIMARY E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Quality Control.
Ch. 2 – Anatomy of the X-ray Machine
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Lecture (2). 2 1.Explain how to produce x-rays and discuss its properties 2.List the basic components of the radiographic machine and identify primary.
Image Quality Radiographic Resolution.
Fundamentals of X-ray Production
Prime Exposure Factors 1
Chapter 2 The X-ray Beam.
Introduction to Dental Radiography and Equipment
RAD 254 Chapter 15 Radiographic Technique 4 primary exposure factors are: kVp, mA, time, distance.
Factors affecting CT image RAD
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
Exposure Factors or Prime Factors
Preparing Variable kVp Technique Charts By Prof. Stelmark.
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Emission Chapter 9.
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Radiographic Quality Visibility and Sharpness
Fundamentals of X-ray Production By Professor Jarek Stelmark.
Medical Equipment Technology Department 1 Introduction to Biomed. Imaging Systems Lecture No.5-6 Dr. Yousif Mohamed Y. Abdallah.
Resident Physics Lectures Christensen, Chapter 2C Production of X-Rays George David Associate Professor Department of Radiology Medical College of Georgia.
Tube Exposure Factors Math Technique Contrast and Density
Sergeo Guilbaud School of Radiologic Sciences
Radiology Steps in radiation production Kilovoltage and voltage.
X-ray tube.
 Make and type of x-ray machine  Incoming line voltage  Kilovoltage  Milliamperage and exposure time  Focal film distance/source-imagine distance.
An early x-ray by Wilhem Rontgen
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
8 November 1895, produced and detected electromagnetic radiation in a wavelength range today known as X- rays or Röntgen rays, electromagnetic radiationwavelengthX-
Radiology Milliaperage. The beam of radiation we use in dentistry may be described in two ways: 1.Quality = penetrating ability - energy of the photon.
Exposure Factors or Prime Factors
Producing An Image RVT: Chapter 6. Learning Objectives: Chapter 6 Understand the 4 factors of radiographic exposure and how each impacts the production.
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
Introduction to Radiography
X-RAY PRODUCTION AND EXPOSURE FACTORS
Stacy Kopso, M.Ed., RT(R)(M)
Principles of Image Production
Exposure Factors Chapter 4
Resident Physics Lectures
Principles of Image Production
Resident Physics Lectures (Year 1)
CHAPTER 7 X-RAY PRODUCTION.
Resident Physics Lectures (Year 1)
What makes a Quality Image
Generation of X-rays Q&A
Presentation transcript:

Producing an X-ray Exposure By Professor Stelmark

Phases of the x-ray exposure: Prep phase Exposure phase

Prep phase prepares the cathode and anode for the exposure

Prep phase Activated by pressing exposure switch halfway down

Prep phase Activated by pressing a separate prep button

The anode begins to revolve Filament heats up to at least 2,200 deg. Celsius. Thermionic emission liberates electrons. Space charge is created The anode begins to revolve 3,000 – 4,000 rpm

The ready light comes on

Exposure Phase Activated by pressing exposure switch all the way down or by activating a separate exposure switch

X-rays are being produced. Anode rotates. Strong positive charge is developed. Projectile electrons strike the target. X-rays are being produced. Thermionic emission continues. Cathode develops strong negative charge. Projectile electrons depart for the anode.

X-rays originate in the target ( focal spot) Exposure will continue until set time is terminated by the timer or the operator’s finger is taken off the button. No x-rays are produced after the exposure is terminated

X-ray quantity is the number of x-rays in the useful beam X-ray Emission The intensity of the x-ray beam of an x-ray imaging system is measured in roentgens (R) or milliroentgens (mR) and is called the x-ray quantity. Another term, radiation exposure ( primary signal intensity), is often used instead of x-ray intensity or x-ray quantity. All have the same meaning and all are measured in R or mR. X-ray quantity is the number of x-rays in the useful beam

Primary Factors The primary exposure technique factors the radiographer selects on the control panel are milliamperage, time of exposure, and kilovoltage peak (kVp). Depending on the type of control panel, milliamperage and exposure time may be selected separately or combined as one factor, milliamperage/second (mAs). Regardless, it is important to understand how changing each separately or in combination affects the radiation reaching the IR and the radiographic image.

Prime Exposure controlling factors mAs (mA x time) kVp ( potential difference) kilo x volt x peak SID ( distance)

The quantity of x-ray photons in an exposure cannot be determined by either the mA or the exposure time alone. Although mA determines the rate of x-ray production, it does not indicate the total quantity, because it does not indicate how long the exposure lasts. Exposure time does not indicate the total quantity either, because it does not measure the rate of x-ray production. To determine the quantity of radiation involved in an exposure, both mA and time must be considered. mA x Time (sec) = mAs

220 mA x 0.077 (sec) = 16.94mAs

As the mAs is increased, the quantity of radiation reaching the IR is increased. As the mAs is decreased, the amount of radiation reaching the IR is decreased.

Changes in mAs have a direct effect on density.  Original image.  Decreased in density when the mAs is decreased by half.  Increase in density when the mAs is doubled.

When the kVp is increased at the control panel, a larger potential difference occurs in the x-ray tube, giving more electrons the kinetic energy to produce x-rays and increasing the kinetic energy overall. The result is more photons (quantity) and higher energy photons (quality).

The kVp affects the exposure to the IR because it alters the amount and penetrating ability of the x-ray beam. Altering the penetrating power of the x-ray beam affects its absorption and transmission through the anatomic tissue being radiographed. Higher kVp increases the penetrating power of the x-ray beam and results in less absorption and more transmission in the anatomic tissues

Higher kVp increases the penetrating power of the x-ray beam and results i less absorption and more transmission in the anatomic tissues

As the thickness of the body part is increased, the quantity of radiation reaching the IR is decreased. As the thickness of the body part is decreased, the amount of radiation reaching the IR is increased.

As SID is increased, the x-ray intensity is spread over a larger area.

The Radiographic Images Analog Digital

Analog Image  An image in which continuous variation in the scene being sensed is represented by continuous variation in image tone, such as the image produced from photosensitive chemicals in a photographic film.  High radiographic density/ high optical density. Dark or black areas on the radiograph Low radiographic density/ low optical density. light or clear areas on the radiograph

Digital Image A digital image is a representation of a two-dimensional image using discrete numerical values. High image brightness (low optical density) refers to bright or white areas on the digital image low image brightness (high optical density) refers to dark or black areas on the digital image