Bode Phase Plots Professor Walter W. Olson

Slides:



Advertisements
Similar presentations
Principles & Applications Small-Signal Amplifiers
Advertisements

Multiplication X 1 1 x 1 = 1 2 x 1 = 2 3 x 1 = 3 4 x 1 = 4 5 x 1 = 5 6 x 1 = 6 7 x 1 = 7 8 x 1 = 8 9 x 1 = 9 10 x 1 = x 1 = x 1 = 12 X 2 1.
Division ÷ 1 1 ÷ 1 = 1 2 ÷ 1 = 2 3 ÷ 1 = 3 4 ÷ 1 = 4 5 ÷ 1 = 5 6 ÷ 1 = 6 7 ÷ 1 = 7 8 ÷ 1 = 8 9 ÷ 1 = 9 10 ÷ 1 = ÷ 1 = ÷ 1 = 12 ÷ 2 2 ÷ 2 =
Fraction IX Least Common Multiple Least Common Denominator
1  1 =.
C.L.I.L. MODULE: ANALYSIS AND DESIGN OF FIRST ORDER RC FILTERS
PID Control Professor Walter W. Olson
Biostatistics Unit 5 Samples Needs to be completed. 12/24/13.
Control and Feedback Introduction Open-loop and Closed-loop Systems
Introduction to Electronic Circuit Design
FET Biasing.
Least Common Multiple (LCM)
Stability Margins Professor Walter W. Olson
PRECALCULUS I Complex Numbers
Root Locus Diagrams Professor Walter W. Olson
Least Common Multiple LCM 2 Methods
Fraction IX Least Common Multiple Least Common Denominator
Adding Up In Chunks.
Introduction to Feedback Systems / Önder YÜKSEL Bode plots 1 Frequency response:
Least Common Multiples and Greatest Common Factors
Forging new generations of engineers
Rational Functions and Models
Bode Diagram (1) Hany Ferdinando Dept. of Electrical Engineering Petra Christian University.
Using Lowest Common Denominator to add and subtract fractions
Math Review with Matlab:
Fundamentals of Electric Circuits Chapter 14 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Bode Magnitude Plots Constructed Bode Actual Bode
Chapter 13 – Sinusoidal Alternating Waveforms Lecture 13 by Moeen Ghiyas 05/05/
Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo Laplace Transforms.
Frequency response I As the frequency of the processed signals increases, the effects of parasitic capacitance in (BJT/MOS) transistors start to manifest.
Loop Shaping Professor Walter W. Olson
1 Electrical Engineering BA (B), Analog Electronics, Lecture 2 ET065G 6 Credits ET064G 7.5 Credits Muhammad Amir Yousaf.
Fundamentals of Electric Circuits Chapter 14
Amplifier Frequency Response
Lecture 22. Bode Plots Frequency Response Bode plots Examples
Frequency Response Methods and Stability
Poles and Zeros and Transfer Functions
Lecture 201 EEE 302 Electrical Networks II Dr. Keith E. Holbert Summer 2001.
Frequency Response Analysis
1 Frequency Response Methods The system is described in terms of its response to one form of basic signals – sinusoid. The reasons of using frequency domain.
Lect21EEE 2021 Bode Plots Dr. Holbert April 16, 2008.
1 Frequency response I As the frequency of the processed signals increases, the effects of parasitic capacitance in (BJT/MOS) transistors start to manifest.
Filters and the Bode Plot
Kent Bertilsson Muhammad Amir Yousaf. DC and AC Circuit analysis  Circuit analysis is the process of finding the voltages across, and the currents through,
سیستمهای کنترل خطی پاییز 1389 بسم ا... الرحمن الرحيم دکتر حسين بلندي - دکتر سید مجید اسما عیل زاده.
Copyright ©2011 by Pearson Education, Inc. publishing as Pearson [imprint] Introductory Circuit Analysis, 12/e Boylestad Chapter 21 Decibels, Filters,
Chapter 8 Frequency-Response Analysis
Chapter 10 Analog Systems
Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo Loop Shaping.
Copyright ©2011 by Pearson Education, Inc. publishing as Pearson [imprint] Introductory Circuit Analysis, 12/e Boylestad Chapter 21 Decibels, Filters,
Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo Sensitivity.
Week 9 Frequency Response And Bode Plots. Frequency Response The frequency response of a circuit describes the behavior of the transfer function, G(s),
Lecture 21: Intro to Frequency Response 1.Review of time response techniques 2.Intro to the concept of frequency response 3.Intro to Bode plots and their.
G(s) Input (sinusoid) Time Output Ti me InputOutput A linear, time-invariant single input and single output (SISO) system. The input to this system is.
Automatic Control By Dr. / Mohamed Ahmed Ebrahim Mohamed Web site:
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Fourth Edition, by Allan R. Hambley, ©2008 Pearson Education, Inc. Lecture 18 Bode Plot, High Pass.
1 Eeng 224 Chapter 14 Frequency Response Huseyin Bilgekul Eeng 224 Circuit Theory II Department of Electrical and Electronic Engineering Eastern Mediterranean.
Frequency response I As the frequency of the processed signals increases, the effects of parasitic capacitance in (BJT/MOS) transistors start to manifest.
Lesson 15: Bode Plots of Transfer Functions
Chapter 3: Frequency Response of AC Circuit Sem2 2015/2016
Filters and the Bode Plot
TOPIC 3: FREQUENCY SELECTIVE CIRCUITS
Lecture V Low Frequency Response of BJT Amplifiers
ELEC 202 Circuit Analysis II
Fundamentals of Electric Circuits Chapter 14
Digital Control Systems (DCS)
دکتر حسين بلندي- دکتر سید مجید اسما عیل زاده
Frequency response I As the frequency of the processed signals increases, the effects of parasitic capacitance in (BJT/MOS) transistors start to manifest.
Chapter 10 Analog Systems
The Frequency-Response Design Method
Presentation transcript:

Bode Phase Plots Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo Bode Phase Plots

Outline of Today’s Lecture Review Frequency Response Reading the Bode Plot Computing Logarithms of |G(s)| Bode Magnitude Plot Construction Phase Phase Computations Full Bode Plot System Identification Using Bode Plots for System Identification

Frequency Response General form of linear time invariant (LTI) system was previously expressed as We now want to examine the case where the input is sinusoidal. The response of the system is termed its frequency response.

Reading the Bode Plot Amplifies Attenuates Input Response Note: The scale for w is logarithmic The magnitude is in decibels Amplifies Attenuates decade also, cycle Input Response

What is a decibel? The decibel (dB) is a logarithmic unit that indicates the ratio of a physical quantity relative to a specified or implied reference level. A ratio in decibels is ten times the logarithm to base 10 of the ratio of two power quantities. (IEEE Standard 100 Dictionary of IEEE Standards Terms, Seventh Edition, The Institute of Electrical and Electronics Engineering, New York, 2000; ISBN 0-7381-2601-2; page 288) Because decibels is traditionally used measure of power, the decibel value of a magnitude, M, is expressed as 20 Log10(M) 20 Log10(1)=0 … implies there is neither amplification or attenuation 20 Log10(100)= 40 decibels … implies that the signal has been amplified 100 times from its original value 20 Log10(0.01)= -40 decibels … implies that the signal has been attenuated to 1/100 of its original value

Computing Logarithms of G(s) Since this does not vary with the frequency it a constant that will be added to all of the other factors when combined and has the effect of moving the complete plot up or down When this is plotted on a semilog graph (w the abscissa) this is a straight line with a slope of 20p (p is negative if the sp term is in the denominator of G(s)) … without out any other terms it would pass through the point (w,MdB) = (1,0)

Computing Logarithms of G(s) a is called the break frequency for this factor For frequencies of less than a rad/sec, this is plotted as a horizontal line at the level of 20Log10 a, For frequencies greater than a rad/sec, this is plotted as a line with a slope of ± 20 dB/decade, the sign determined by position in G(s)

Computing Logarithms of G(s) wn is called the break frequency for this factor For frequencies of less than wn rad/sec, this is plotted as a horizontal line at the level of 40Log10 wn, For frequencies greater than wn rad/sec, this is plotted as a line with a slope of ± 40 dB/decade, the sign determined by position in G(s)

Bode Plot Construction When constructing Bode plots, there is no need to draw the curves for each factor: this was done to show you where the parts came from. The best way to construct a Bode plot is to first make a table of the critical frequencies and record that action to be taken at that frequency. You want to start at least one decade below the smallest break frequency and end at least one decade above the last break frequency. This will determine how semilog cycles you will need for the graph paper. This will be shown by the following example.

20-slope for two decades (40) =60 Example Plot the Bode magnitude plot of Break Frequency Factor Effect Cum value Slope dB/dec 0.01 K=10 20Log10(10)=20 20 … s Line -20db/dec Thru (1,0) 20-slope for two decades (40) =60 -20 0.2 s+0.2 +20Log10(.2)= -13.98 60+6.02=46.02 3 s+3 -20Log10(3)= -9.54 46.02-9.54= 36.48 4 s2+4s+16 -40Log10(4)= - 24.08 36.48- 24.08= 12.4 -60 5 s2+2s+25 +40Log10(5)= 27.96 32.4+27.96= 40.36

Example Actual Bode Constructed Bode

Phase For a sinusoidal input, phase represents the lag of the system or, alternatively, the processing time of the system to produce an output from the input Phase is measured as an angle A cycle of the input is consider to take 2p radians or 360 degrees Phase is the angular distance it takes for the output to represent the input Thus it is normal that as the frequency increases that the phase also increase In the case where the phase exceeds 180 degrees, the output appears to “lead” the input. This is particularly evident in the range of 270 to 360 degrees.

Phase As with magnitude there are 4 factors to consider which can be added together for the total phase angle. We will consider, in turn, The sign will be positive if the factor is in the numerator and negative if the factor is in the denominator

Phase Computations

Phase Computations

Example Plot the Bode Phase Plot for

Example Plot the Bode Phase Plot for Again a table is useful: Frequency Factor wn z Effect Cum Value Cum Slope s-1 constant -90 -90 - 0.02 s+0.2 break up at 45/dec 45/dec 0.3 s+3 Break down at -45/dec 0.4 4 0.5 Break down at -90/dec -90/dec 5 0.2 Break up at 90/dec 2 take out 45/dec -45/dec 30 take out -45/dec 40 take out -90/dec 90/dec 50 take out 90/dec total exponent 3-4=-1 >> -90

Example Asymptotic Bode Phase Actual Bode Phase

Full Bode Plot Constructed Bode Actual Bode Asymptotic Bode Phase Actual Bode Phase

Matlab Command bode(sys)

System Identification It is not unusual for a field engineer to be shown a piece of equipment and then asked if he can put a control system on it or replace the control system for which there are no parts. The task of determining how an unknown structure responds is called “System Identification”. To identify a system, there are many tools are your disposal First and foremost, what should the system structure look like? Motors are often first order transfer functions ( ) which you then attempt to identify the constants Perform step tests and see what the response looks like Perform tests with sinusoidal outputs and use the Bode plot to identify the system Apply statistical/time series methods such as ARMAX and RELS

Using Bode Plots for System Identification The overall order of the system will be the high frequency phase divided by 90 degrees The exponent of the “s” term will be the slope on the magnitude plot at the lowest frequency divided by 20 Alternatively, the exponent of “s” is the lowest frequency phase divided by 90 degrees. The system gain constant (Kt) in dB will be the height value at the extension of the “s” term line on the magnitude plot to where it crosses1 rps Starting from the left (the lowest frequency) on the magnitude plot, determine the structural components using the change in slopes in increments of 20 degrees either up or down Then by using the intersection of the lines at those places match to the test curve, determine the break frequencies Write the transfer function in the form

Example exp of s = -2 overall order =3 -40 dB/dec -60 dB/dec Kt=35 dB 80 dB/dec 0.52 2.2 4 20

Example exp of s = -2 overall order =-3 -40 dB/dec -60 dB/dec Kt=35 dB 0.52 2.2 4 20

Example exp of s = -2 overall order =-3 -40 dB/dec -60 dB/dec Kt=35 dB -60 dB/dec 0.52 2.2 4 20

Example

Summary Phase Phase Computations Full Bode Plot System Identification For a sinusoidal input, phase represents the lag of the system or, alternatively, the processing time of the system to produce an output from the input Phase Computations Full Bode Plot System Identification The task of determining how an unknown structure responds is called “System Identification”. Using Bode Plots for System Identification Next Class: Laplace Transforms