LOW IMPEDANCE RESTRICTED DIFFERENTIAL EARTH FAULT

Slides:



Advertisements
Similar presentations
Protection IED platform, product release 1
Advertisements

Announcements Be reading Chapters 9 and 10 HW 8 is due now.
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Earthing systems, Harmonics Currents and GFP
Earthing systems, Harmonics Currents and GFP
CHAPTER 3: SPECIAL PURPOSE OP-AMP CIRCUITS
Understanding electrical networks to enhance their protection ? Situate the protection relay Ask the customer the right questions Duration: 43:35 min Expert:
GENERATOR PROTECTION.
SYMAP-BC SYMAP-BC.
Given Connections Solution
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
Differential protection : (protective relaying by Blackburn)
© 2007 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
Basic Electricity.
MIG II DIGITAL FEEDER PROTECTION
1 EXPERIENCE AND RELIABILITY. 2 Short circuit loop measurements EN EN
Engineering Practice Electric Fitting Resistance Electrical resistance is the ratio of voltage drop across a resistor to current flow through the resistor.
Vidhyadeep Institute Of Management & Technology, Anita, Kim Electronics & Communication Department Guided by Mr. Vicky Paperwala.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Electrical Installation 2
POWER SYSTEM PROTECTION
1 © ABB AB, Application of Unit Protection Schemes for Auto-Transformers Zoran Gajić ABB AB Vasteras, Sweden Authors: Z. Gajić, ABB Sweden.
RCD TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
IP Other safety devices © Oxford University Press 2011 Other safety devices.
KD Relay Application: Compensator distance relay that provides a single zone of phase protection for all three phases. It provides tripping for phase to.
Human Life & Home Protection Device (Protector) Boris Fradkin 2015 A.L.F. Enterprise.
Assumption University Thailand EE4503 Electrical Systems Design Main Circuit 1.
EE 445 Course Presentation Power System Protection
Protection of Microgrids Using Differential Relays
Lecture 22 Unbalanced Faults and Power System Protection Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Protection & Switchgear
Transformer Protection Over-current protection in the form of fuses may be the only protection provided to a small 100 kVA, 11 kV/440 V distribution transformer.
Advanced Coordination Topics – EasyPower w/ Power Protector
Lecture 22 Unbalanced Faults and Power System Protection Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Announcements Read Chapters 10 and 11
1 Distributed Generation and Power Quality-Continued.
POWER HOUSE.
Evolution and Prospects of Relay Protection and Automation Systems Evolution and Prospects of Relay Protection and Automation Systems Moderator: Janez.
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
UETTDRTS01B MAINTAIN NETWORK PROTECTION & CONTROL SYSTEMS.
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
Survey of Smart Grid concepts and demonstrations Smart substation Ari Nikander.
Types of business ownership. Advantages to Sole Proprietorship  Keep all profits  Less Expensive  Easier to use.
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
Power System Protective Relaying-Part One
Part Three – Relay Input Sources
Design a protection System of 220/33kV Grid Station United Arab Emirates University College of Engineering Saif Mohammed AL Aryani Ahmed Soruor.
Protection and Relay Schemes
PS 1 – Transformer Protection, Monitoring & Control
Motor Protection Dr. Hendro Rijanto.
Protection of Power Systems
PROTECTION AGAINST INDIRECT CONTACT
D - connection DELTA 3-phase distribution system
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Webinar Notes Please use the Q & A utility to ask us any questions concerning the material being presented. Please contact Brittany Socha - chat line.
الباب الثاني الأنواع المختلفة للشركات
Agenda Introduction of Protective Relays
Power System Protective Relaying-Part One
Chapter 4 – Operational Amplifiers – Part 1
By LCdr NS Wickramasinghe BSc Hons (E & E Eng) MSc (HRM) AMIE (I) AMIE (SL) C Eng (I)
Electrical components and systems
Difference between Earthing & Grounding
Exercise 9 Power systems.
ALTERNATIVE CURRENT & VOLTAGE SENSORS
ประกาศกระทรวงอุตสาหกรรม ฉบับที่ 5292 (พ.ศ. 2562)
Presentation transcript:

LOW IMPEDANCE RESTRICTED DIFFERENTIAL EARTH FAULT ND10 LOW IMPEDANCE RESTRICTED DIFFERENTIAL EARTH FAULT

PROTECTIVE FUNCTIONS 50/51 Phase overcurrent 50N/51N - 87NHIZ. Residual overcurrent or high impedance restricted differential ground fault 64REF Biased restricted differential ground fault BF Breaker Failure

64REF – MOST COMMON APPLICATIONS Like every differential protective function 64REF is largely adopted in case of high selectivity needs. Common applications are generator protection and transformer protection. G ~ 64REF 64REF

BEFORE ND10 – 87NHIZ ONLY SEVERAL CONS Design Large cubicle NAXX STABILIZING RESISTOR SEVERAL CONS Design Large cubicle Connections Low liability External devices NAXX 3 CT’s Low leakage reactance type according to IEC Class PX, TPS or BS Class X 87N METROSIL 50 51 3 CT’s Phase Currents EXPENSIVE SOLUTION

ND10 – ONE DEVICE ONLY ND10 CHEAPER SOLUTION CT 3 CT’s Residual current ND10 50 51 3 CT’s Phase Currents CHEAPER SOLUTION

ND10 – 64 REF LOW IMPEDANCE FROM SAME INPUTS Separate inputs for phase current and current from earth connection. Earth overcurrent and biased restricted earth fault protective functions both contemporaneously performed. Phase overcurrent protective function from same 3 CT’s set. ND10 50N 51N 64 REF 50 51 RELIABLE SOLUTION

EASIEST SOLUTION in case of EARTH FAULT DIFFERENTIAL FUNCTION ND10 – MANY ADVANTAGES Biased 64REF is internally calculated. Easy connections. RS and METROSIL design is not required. No one external device is needed for stabilization. Smaller cubicles. ND10 50N 51N 64 REF 50 51 EASIEST SOLUTION in case of EARTH FAULT DIFFERENTIAL FUNCTION

External Market Support Oscar Ornago tel. +39.02.57495753 Piazza Federico Mistral, 7 20139 Milano (MI) ITALY Tel: +39.02.5749571 Fax: +39.02.57403763 e-mail: thytronic@thytronic.it company web site: www.thytronic.it products web site: www.pro-n.it External Market Support Oscar Ornago tel. +39.02.57495753 e-mail: o.ornago@thytronic.it