K. W. Hill, M. L. Bitter, S.D. Scott S. G. Lee

Slides:



Advertisements
Similar presentations
Toolkit for testing CCD cameras
Advertisements

Matter waves 1 Show that the wavelength of an electron can be expressed as where E is the energy in volts and  in nm.
FOM-Institute for Plasma Physics Rijnhuizen Association Euratom-FOM T E CT E C T E CT E C Carbon Chemical Erosion Yield Experiments in Pilot-PSI Jeroen.
Ion Heating and Velocity Fluctuation Measurements in MST Sanjay Gangadhara, Darren Craig, David Ennis, Gennady Fiskel and the MST team University of Wisconsin-Madison.
Examples of ITER CODAC requirements for diagnostics
An Image Filtering Technique for SPIDER Visible Tomography N. Fonnesu M. Agostini, M. Brombin, R.Pasqualotto, G.Serianni 3rd PhD Event- York- 24th-26th.
Line Features in RHESSI Spectra Kenneth J. H. Phillips Brian R. Dennis GSFC RHESSI Workshop Taos, NM 10 – 11 September 2003.
Thermal and nonthermal contributions to the solar flare X-ray flux B. Dennis & K. PhillipsNASA/GSFC, USA J. & B. SylwesterSRC, Poland R. Schwartz & K.
000509EISPDR_SciInvGIs.1 EIS Performance and Operations Louise Harra Mullard Space Science Laboratory University College London.
Geant 4 simulation of the DEPFET beam test Daniel Scheirich, Peter Kodyš, Zdeněk Doležal, Pavel Řezníček Faculty of Mathematics and Physics Charles University,
1 LOA-ENSTA. 2 3 For PW class laser, a contrast better than is required I ASE has to be < W/cm² The ASE intensity is enough to generate.
Results from first tests of TRD prototypes for CBM DPG Frühjahrstagung Münster 2011 Pascal Dillenseger Institut für Kernphysik Frankfurt am Main.
W. Heidbrink, G. Kramer, R. Nazikian, M. Van Zeeland, M. Austin, H. Berk, K. Burrell, N. Gorelenkov, Y. Luo, G. McKee, T. Rhodes, G. Wang, and the DIII-D.
Advanced GAmma Tracking Array
Spatially Resolved High Resolution X-Ray Crystal Spectrometry and Radiation Tolerant 2D X-Ray Imaging Schemes for ICF Plasmas including NIF Ignition Experiments.
R Barnsley, Moscow, Nov ADAS/SANCO (Atomic data and impurity transport codes) - Evaluation of suitable impurities and ionization stages. - Simulations.
RHESSI/GOES Xray Analysis using Multitemeprature plus Power law Spectra. J.McTiernan (SSL/UCB)
RHESSI/GOES Xray Analysis using Multitemeprature plus Power law Spectra. J.McTiernan (SSL/UCB) ABSTRACT: We present spectral fits for RHESSI and GOES solar.
Temporal evolution of plasma rotation measurement in tokamaks using an optical monochromator and two photomultipliers as detector Severo J. H. F. .
Outline (HIBP) diagnostics in the MST-RFP Relationship of equilibrium potential measurements with plasma parameters Simulation with a finite-sized beam.
Richard M. Bionta XTOD Beam and Detector October 12-13, 2004 UCRL-PRES-XXXXX XTOD Beam and Detector Simulations Facility Advisory.
49th Annual Meeting of the Division of Plasma Physics, November , 2007, Orlando, Florida Ion Temperature Measurements and Impurity Radiation in.
30 Ge & Si Crystals Arranged in verticals stacks of 6 called “towers” Shielding composed of lead, poly, and a muon veto not described. 7.6 cm diameter.
D. Borba 1 21 st IAEA Fusion Energy Conference, Chengdu China 21 st October 2006 Excitation of Alfvén eigenmodes with sub-Alfvénic neutral beam ions in.
Measurements with the KSTAR Beam Emission Spectroscopy diagnostic system Máté Lampert Wigner Research Centre for Physics Hungarian Academy of Sciences.
Nils P. Basse Plasma Science and Fusion Center Massachusetts Institute of Technology Cambridge, MA USA ABB seminar November 7th, 2005 Measurements.
2D Position Sensitive Detector for Plasma diagnosis
Interim progress summary: ITER Imaging X-ray crystal spectrometer design Sam Davis - UKAEA Robin Barnsley - ITER.
Kaschuck Yu.A., Krasilnikov A.V., Prosvirin D.V., Tsutskikh A.Yu. SRC RF TRINITI, Troitsk, Russia Status of the divertor neutron flux monitor design and.
Abstract A time resolved radial profile neutron diagnostic is being designed for the National Spherical Torus Experiment (NSTX). The design goal is to.
Profile Measurement of HSX Plasma Using Thomson Scattering K. Zhai, F.S.B. Anderson, J. Canik, K. Likin, K. J. Willis, D.T. Anderson, HSX Plasma Laboratory,
J A Snipes, 6 th ITPA MHD Topical Group Meeting, Tarragona, Spain 4 – 6 July 2005 TAE Damping Rates on Alcator C-Mod Compared with Nova-K J A Snipes *,
Characterization of core and edge turbulence in L- and H-mode Alcator C-Mod plasmas Outline: Alcator C-Mod tokamak Fluctuation diagnostics Low to high.
T.M. Biewer, Oct. 20 th, 2003NSTX Physics Meeting1 T. M. Biewer, R.E. Bell October 20 th, 2003 NSTX Physics Meeting Princeton Plasma Physics Laboratory.
Tunable, resonant heterodyne interferometer for neutral hydrogen measurements in tokamak plasmas * J.J. Moschella, R.C. Hazelton, M.D. Keitz, and C.C.
Beam Ion Profiles with the SSNPA Diagnostic Columbia U Comp-X General Atomics INEL Johns Hopkins U LANL LLNL Lodestar MIT Nova Photonics NYU ORNL PPPL.
2 The Neutral Particle Analyzer (NPA) on NSTX Scans Horizontally Over a Wide Range of Tangency Angles Covers Thermal ( keV) and Energetic Ion.
Walid DRIDI, CEA/Saclay n_TOF Collaboration Meeting, Paris December 4-5, 2006 DAPNIA Neutron capture cross section of 234 U Walid DRIDI CEA/Saclay for.
Pellet Charge Exchange Measurement in LHD & ITER ITPA Tohoku Univ. Tetsuo Ozaki, P.Goncharov, E.Veschev 1), N.Tamura, K.Sato, D.Kalinina and.
Supported by Columbia U Comp-X General Atomics INEL Johns Hopkins U LANL LLNL Lodestar MIT Nova Photonics NYU ORNL PPPL PSI SNL UC Davis UC Irvine UCLA.
Fast Electron Temperature Scaling and Conversion Efficiency Measurements using a Bremsstrahlung Spectrometer Brad Westover US-Japan Workshop San Diego,
Fast ion collective Thomson scattering diagnostic for ITER S.B. Korsholm 1,2, H. Bindslev 1, F. Leipold 1, F. Meo 1, P.K. Michelsen 1, S. Michelsen 1,
Measurement of toroidal rotation velocity profiles in KSTAR S. G. Lee, Y. J. Shi, J. W. Yoo, J. Seol, J. G. Bak, Y. U. Nam, Y. S. Kim, M. Bitter, K. Hill.
N OVIMIR A. P ABLANT M. B ITTER, L.F. D ELGADO -A PARICIO, M. G OTO, K.W. H ILL, S. L AZERSON, S. M ORITA, L. R OQUEMORE N OVIMIR A. P ABLANT M. B ITTER,
Objectives Much better spatial resolution Velocity space discrimination W. Heidbrink, M. Van Zeeland, J. Yu FIDA Imaging Proposal.
Observations of electrons in the Intense Pulse Neutron Source (IPNS) Rapid Cycling Synchrotron (RCS) J. C. Dooling, F. R. Brumwell, W. S. Czyz, K.C. Harkay,
1 Imaging X-Ray Crystal Spectrometer with Fast Detector for Fast Measurement of Profiles of Ti and Intrinsic Plasma Rotation Velocity without Perturbation.
Comparison between X-ray measurements with the GEM detector and EFIT calculations Danilo Pacella Present address: JHU, Baltimore, MD Permanent address:
Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.
RHESSI and the Solar Flare X-ray Spectrum Ken Phillips Presentation at Wroclaw Workshop “ X-ray spectroscopy and plasma diagnostics from the RESIK, RHESSI.
D-Alpha Fast-Ion Diagnostic: Recent Results from DIII-D W.W. Heidbrink, UC Irvine D-Alpha Diagnostic: Yadong Luo, K. Burrell, + Ion Cyclotron Heating:
Characterization of Fast Ion Power Absorption of HHFW in NSTX A. Rosenberg, J. Menard, J.R. Wilson, S. Medley, R. Dumont, B.P. LeBlanc, C.K. Phillips,
Calculation of the Coded Aperture zero-beam-size image (the “image”). The CA fitting procedure: The image is parameterized as a Sum-Of-Gaussians.
T. Biewer, March 3 rd, 2003NSTX Physics Meeting Measurements of Edge Impurity Ion Dynamics During RF Heating T. M. Biewer, R.E. Bell March 3 rd, 2003 NSTX.
XBSM Analysis - Dan Peterson Review of the optics elements: Pinhole (“GAP”), FZP, Coded Aperture Extracting information from the GAP what is the GAP width?
Neutral beam ion loss measurement and modeling for NSTX D. S. Darrow Princeton Plasma Physics Laboratory American Physical Society, Division of Plasma.
Rev 131 Enceladus’ Plume Solar Occultation LW Esposito and UVIS Team 14 June 2010.
Evaluation of Anomalous Fast-Ion Losses in Alcator C-Mod S. D. Scott Princeton Plasma Physics Laboratory In collaboration with R. Granetz, D. Beals, C.
Hard X-rays from Superthermal Electrons in the HSX Stellarator Preliminary Examination for Ali E. Abdou Student at the Department of Engineering Physics.
T. Biewer, Sep. 20 th, 2004 NSTX Results Review of 11 Edge Ion Heating by Launched HHFW in NSTX T.M. Biewer, R.E. Bell, S. Diem, P.M. Ryan, J.R.
Gamma Ray Spectrometry System Design for ITER Plasma Diagnostics
Associazione EURATOM-ENEA sulla Fusione
Turbulence associated with the control of internal transport barriers
MHD Induced Fast Ion Loss Diagnostic for Alcator C-Mod
Status of Equatorial CXRS System Development
Investigation of triggering mechanisms for internal transport barriers in Alcator C-Mod K. Zhurovich C. Fiore, D. Ernst, P. Bonoli, M. Greenwald, A. Hubbard,
Comparisons of Measurements and Gyro-kinetic Simulations of Turbulence and Trans-port in Alcator C-Mod EDA H-Mode Discharges M. B. Sampsell, R. V. Bravenec.
Visible Doppler Spectrometer for Edge Toroidal Rotation
Evaluation of the main ion flow and temperature using the GPI system
D. S. Darrow Princeton Plasma Physics Laboratory
Presentation transcript:

K. W. Hill, M. L. Bitter, S.D. Scott S. G. Lee Development of a High Resolution X-Ray Imaging Crystal Spectrometer for Measurement of Ion-Temperature and Rotation-Velocity Profiles in Fusion Energy Research Plasmas K. W. Hill, M. L. Bitter, S.D. Scott Princeton Plasma Physics Laboratory, Princeton, NJ S. G. Lee NFRC, Korea Basic Science Institute, Daejeon, Korea A. Ince-Cushman, J. E. Rice MIT Plasma Science and Fusion Center, Cambridge, MA Ch. Broennimann, E. F. Eikenberry SLS, Paul Scherrer Institute, Villigen, Switzerland R. Barnsley Queen’s University Belfast and EFDA/JET Visiting researcher at ITER International Team, Cadarache, France Presented at the 16th International Toki Conference: Advanced Imaging and Plasma Diagnostics, December 5-8, 2006, Toki, Japan

Abstract * Supported by U.S. DoE Contract No. DE-AC02-76-CHO-3073 A high resolution imaging x-ray crystal spectrometer (XICS) is being developed for Doppler measurement of radial profiles of ion temperature, Ti, and toroidal rotation velocity on Alcator C-mod. The XICS consists of a spherically bent crystal and a 2D position sensitive x-ray detector, and provides x-ray spectra from highly charged ions from multiple sightlines through the plasma. The proof of principle of the IXCS was demonstrated by measurement of Ar XVII Ka spectral images at from +/- 8 cm of the plasma height in Alcator C-Mod and +/- 40 cm in NSTX. However, the time resolution was limited to values >100 ms by the ~ 400 kHz count-rate limit of the available 2D detector. A new silicon pixel array detector, the PILATUS II, with a count-rate capability of 1 MHz PER PIXEL, has been tested on C-Mod by recording spectra of Ar XVII at 3.1 keV, and should enable XICS measurements with time resolution < 10 ms. The detector test results and C-Mod XICS design and expected performance will be presented. * Supported by U.S. DoE Contract No. DE-AC02-76-CHO-3073

Main Points Proof-of-Principle of new imaging x-ray crystal spectrometer (XCS) for Ti- and rotation-profile (v) measurement previously demonstrated on NSTX, Alcator C-Mod, and TEXTOR; temporal and spectral resolution limited by the available 2d x-ray detector New pixelated silicon detector with better spatial resolution and 100,000 times higher count-rate capability removes limitations; detector tested on existing C-Mod spectrometer Imaging XCS being designed to measure full radial profiles of Ti and v on C-Mod, and imaging XCS adopted for ITER Calculations of uncertainty in Ti and v measurements predict performance of C-Mod and ITER spectrometers

Imaging x-ray crystal spectrometer is versatile Measure time dependent profiles Ion and electron temperature Plasma rotation Impurity charge-state distribution All plasma types Neutral-beam injection not required Simple design, construction Single spectrometer measures full profile Spherically bent crystal Two-dimensional imaging x-ray detector ASIC-based electronics and PC data acquisition

Spherical crystal images spectra in vertical direction

Spectra from NSTX and C-Mod have good resolution

Spatially resolved Te, Ti inferred from NSTX Ar XVII spectra

Lessons learned from operation of spectrometer on C-MOD and NSTX Initial Ar spectra with modestly high resolution obtained (2003-2005) MWPC detector resolution not quite adequate for Ti measurement Higher resolution detector now available will enable Ti measurement High signal and background count rates mitigated 8-cm diameter crystal masked down to 6 x 2 mm2 area Graded x-ray attenuators ~equalize count rate across radial profile; another factor of 1/8 reduction in count rate Limited shielding against hard x rays or gamma rays added Scattered x rays from crystal and holder reduced by apertures Significant count-rate limitation observed with MWPC - 400 kHz Inherent detector count-rate limit Pileup rejection in Time-To-Digital converter (TDC) Throughput limitation in electronic interface Solved by Pilatus II detector with count rate capability of 1 MHz PER PIXEL

PILATUS detector solves count-rate and resolution issues ~8.5cm 2-D array of x-ray sensitive pixels - Each module is 487 x 195 pixels - Each pixel is 0.172 x 0.172 mm2 Modular (build array of any size) Each pixel can handle a count rate of 1MHz - total count rate of previous 10 cm x 30 cm MWPC was 400 kHz (Factor of 100,000 increase) Readout time down to 2.54 ms Worked well in the electrically & mechanically noisy C-Mod environment Radiation hard (tested to 1014 n/cm2)

Shot-integrated He-like Ar spectrum from Pilatus detector shows excellent spectral resolution The Pilatus detector was installed on one of the poloidally viewing Hirex spectrometers. w x y z w 3.949Å x 3.966Å y 3.969Å z 3.994Å Spectral Resolution

PILATUS II spectra similar to HIREX spectra Spectra are for the same discharge but with slightly different views No indication of problems in the electrically noisy C-Mod environment Raw Spectra Normalized Spectra

PILATUS II Ar spectra track stored energy Measured with 20 ms time resolution PILATUS readout time now down to 2.54 ms Ar XVII resonance line, w, measured by PILATUS II detector

Background rate low for unshielded PILATUS detector Peak background count rate = 14 counts/pixel/s Peak neutron rate = 5.8E13 n/s Peak x-ray rate > 1000 counts/pixel/s

Imaging XCS configuration selected for C-Mod and ITER Because of the successful demonstration of the imaging XCS and the PILATUS II detector, an imaging XCS is being designed to measure full profiles of Ti and v on C-Mod, and the imaging XCS design has been selected for ITER. On ITER the background from neutron and  radiation will increase the uncertainty in measurement of the line position and width.

C-Mod Imaging XCS is being designed for Ti, v profiles crystals detectors

Full plasma radial view and toroidal component planned for C-Mod 2:1 imaging 3 PILATUS detectors ~30% toroidal fraction

ITER imaging x-ray spectrometer Design options for spectrometer location Ex-port Better access Better shielding In-port Wider view of plasma Choice will be based on: - Neutronics modelling Detector radiation hardness Detector background rejection Status of ITER x-ray spectroscopy, R Barnsley, IPR, India, 8th Feb 2006.

Neutron shielding is a major factor in the design Horizontal cross-section of 40deg. Sector Neutron transport modelled by Atilla code Flux at first wall ~ 1014 n/cm2.s Status of ITER x-ray spectroscopy, R Barnsley, IPR, India, 8th Feb 2006.

Modeled neutron levels for the ITER upper port imaging crystal spectrometer. Status of ITER x-ray spectroscopy, R Barnsley, IPR, India, 8th Feb 2006.

Estimates of performance of C-Mod and ITER spectrometers Estimates of uncertainty in Ti measurement and minimum resolvable toroidal rotation velocity were made for C-Mod imaging spectrometer. On ITER, both x-ray continuum and fusion-neutron background will increase uncertainties in measurement of Ti and vtor. Numerical and analytic statistical analyses were made to quantify these increased uncertainties.

Numerical line position and width agree with equations N = 50000 counts in Gaussian Nexp = 5000 No background  = 13.78556 pixels I = 2.86904 pixels s = .0128111 pixels I / sqrt(N) = .0128307 pixels s = 0.009171 pixels I / sqrt(2N) = 0.0090727 pixels Generate normal dist with RANDOMN Bin onto detector pixels with HIST Fit Gaussian with GAUSSFIT Record line position and width Do “experiment” “Nexp” times Calculate moments for  and 

Statistical contributions to vtor and Ti error can be small C-Mod spectrometer 2000 to 30000 counts in 10 ms Background not included 1-3 km/s resolvable 1 - 3% error in Ti

Position and width uncertainties increase with background approximately as expected Uncertainty for P/B=1 increases 2x for position 3x for width Simulated Gaussian plus background a=2.13, b=7.67, c=1.24, d=2.92 Equations from I. H. Hutchinson, “Statistical Uncertainty in Line Shift and Width Interpretation” Position Width

Conclusions New imaging x-ray spectrometer developed for Ti -, Te - and rotation-profile measurement on NSTX and Alcator C-Mod. Imaging concept verified on C-Mod, NSTX, and TEXTOR. Very small crystal area provided high count rates from C-Mod Suggests small area crystals suitable for ITER Detector count-rate limit and position-resolution issues solved by PILATUS II detector. Imaging spectrometer being designed for C-Mod. Numerical and statistical analyses provide basis for estimating performance of imaging XCS on C-Mod and on ITER with neutron background.