Velleman Oscilloscope: Windows 7 by Mr. David Fritz

Slides:



Advertisements
Similar presentations
1 Application Software Course Simulink By: Mahdi Akbari 2010.
Advertisements

PGA309 EVM Multi-Cal-Tools-V1.6a User’s Guide
Adders Used to perform addition, subtraction, multiplication, and division (sometimes) Half-adder adds rightmost (least significant) bit Full-adder.
Follow the instruction to install the PC Suite from the SD card: 1.Go to the settings -> SD Card & phone storage -> Enable the mass storage only mode 2.Connect.
Tutorial 9 – Creating On-Screen Forms Using Advanced Table Techniques
Measurements and Their Uncertainty 3.1
Rhesy S.ppt proRheo GmbH
Mike Scott University of Texas at Austin
1 Click here to End Presentation Software: Installation and Updates Internet Download CD release NACIS Updates.
Microsoft®.
Office 2003 Introductory Concepts and Techniques M i c r o s o f t Windows XP Project An Introduction to Microsoft Windows XP and Office 2003.
ETS4 - What's new? - How to start? - Any questions?
Velleman Arbitrary Function Generator: Windows 7 by Mr. David Fritz
1 1 Mechanical Design and Production Dept, Faculty of Engineering, Zagazig University, Egypt. Mechanical Design and Production Dept, Faculty of Engineering,
Lesson 2 Navigating LabVIEW
DAQmx下多點(Multi-channels)訊號量測
Factor P 16 8(8-5ab) 4(d² + 4) 3rs(2r – s) 15cd(1 + 2cd) 8(4a² + 3b²)
© 2012 National Heart Foundation of Australia. Slide 2.
Getting started with LEGO NXT Mindstorms software This is intended to be a short introduction to the LEGO Mindstorms software and programming the LEGO.
A lesson approach © 2011 The McGraw-Hill Companies, Inc. All rights reserved. a lesson approach Microsoft® PowerPoint 2010 © 2011 The McGraw-Hill Companies,
Fisica Generale - Alan Giambattista, Betty McCarty Richardson Copyright © 2008 – The McGraw-Hill Companies s.r.l. 1 Chapter 21: Alternating Currents Sinusoidal.
©Brooks/Cole, 2001 Chapter 12 Derived Types-- Enumerated, Structure and Union.
PSSA Preparation.
Interface between Velleman PCSGU250 and MATLAB
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
This lesson covers the following outcomes Unit 54 P1, P7, P8 Unit 6 P10, P11.
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
Analog Discovery Oscilloscope for Windows 7 by Mr. David Fritz and Ms. Ellen Robertson Financial support to develop this tutorial was provided by the Bradley.
Experiment 11: An Inverting Amplifier
Time Varying Signals.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
The Oscilloscope: Basic Features & Functions  Source –Determines which signal is compared to the trigger settings.  Level –Determines where on the edge.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
USE OF THE OSCILLOSCOPE Modified from a presentation written by David Matzke by: Donald Wisniewski, Dawn Wisniewski, Huzefa Mamoola and Angela Nolte Under.
Electric Curcuits and Measurements Basic Electrical components and their functions Measurements of electrical circuits characteristics - Multimeter - Oscilloscope.
1 AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz.
Magnitude and Phase Measurements
Pulse Width Modulation (PWM) LED Dimmer Circuit
Purpose Learn how to use basic electronic equipment:
The Function Generator and the Oscilloscope Dr. Len Trombetta 1 ECE 2100.
Oscilloscope Tutorial
 Popular instrument to show time, voltage both DC and AC. Shows Volts / Time.  Display waveforms. Spectrum scope shows volts to Frequency  Cathode (-ve.
Introduction to the Oscilloscope Professor Ahmadi ECE002 George Washington University.
Week 7: Design a Logarithmic Voltmeter A variation on Experiment 19 Validation by 8pm on October 14.
Experiment 12 Non-Inverting Amplifier. Experimental Procedure Clarification in Step 3 (Modeling) – To perform the DC Sweep in the sinusoidal voltage source.
Waveform 2.1 Basic Digital Waveforms 2 Measurement Paul Godin Updated October 2009.
Velleman Oscilloscope: Windows XP by Mr. David Fritz.
2013 High Tech Update - L973D1 973D High Tech Update.
Analog Discovery Arbitrary Function Generator for Windows 7 by Mr
Introduction to the Oscilloscope
Introduction to Phasors Week 2: Experiment 22. Experimental Procedures Do not do the steps labeled “Extra Credit” in the Procedure. No extra credit will.
 Voltage can be produced such that, over time, it follows the shape of a sine wave  The magnitude of the voltage continually changes.  Polarity may.
Vadodara Institute of Engineering kotanbi Active learning Assignment on Single phase AC CIRCUIT SUBMITTED BY: 1) Bhatiya gaurang.(13ELEE558) 2)
Physics 2225: Working With Electronic Equipment Purpose  Learn how to use basic electronic equipment: Digital multi meter Oscilloscope Function generator.
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
Due DateWeek Experiment in Lab ManualTitle Pre-Lab Report Validation Post- Validation Report 3/13/20123/14/20123/17/20126To be distributedMake-up Lab for.
Generator Frequency Knob Frequency display Frequency Range Output Amplitude (output Level) Knob -20 db (output attenuate) Functions.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
Electronic workshop Dr. Imtiaz Hussain URL :
Lecture 5: DMM & Oscilloscope 1. DMM can be used to measure: DC & AC voltages – current - resistance - BJT (β test) - diode test - short circuit test,
Phasors and Kirchhoff’s Current Law
BASIC INSTRUMENTS - oscilloscopes
Digital Multimeter – Basic Guide
The Function Generator and the Oscilloscope Dr. Len Trombetta and Dr. Dave Shattuck 1 ECE 2100.
Instrumentation & Root Mean Square Voltage
(5) DMM & Oscilloscope.
Introduction to the Oscilloscope
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
Lab 8 Induction to Oscilloscope
Presentation transcript:

Velleman Oscilloscope: Windows 7 by Mr. David Fritz

Installing Oscilloscope Drivers Unzip the Velleman scope drivers from Velleman web site to somewhere easy to find (e.g. c:/Vscope) Plug your scope into the USB port Click: Start > Control Panel > System > Device Manager Scroll down to "PCSGU250 Device“ Right Click "PCSGU250“ Click "Update Driver Software...“ Click "Browse my computer for driver software“ Browse to where you unzipped the driver directory "PCSGU250Driver_WinUSB“ Click the directory Click "OK“ Click "Next" and follow the directions

You should now have the drivers installed The scope software should be able to find the USB scope. Launch the scope control software. Start > Programs > Velleman > PcLab2000LT (You will probably want to make a shortcut)

What if the software doesn’t find the scope? • You may see a pop-up that says you are in Demo mode because the software did not find the scope. This is usually not a problem. Click Options > Hardware Setup > PCSGU250 > OK The software will find the scope and the blue light will illuminate on the front of the scope.

If you still can’t get the scope to connect… Make sure that you installed the software and drivers from the Velleman website. The CD included with your scope does not contain the latest versions. Try re-installing the drivers from the Velleman web site. See the ECE Tech Support Guru for assistance. Branden McKagen bmckagen@vt.edu 346 Whittemore Hall 9:00-Noon M-F, 1:30-5:00 MWF If you have a scope that will not work, see a GTA in the OpEL for assistance.

Using the Velleman Oscilloscope

Sine wave with a DC offset V(t) = A + Bsin(2πft) f = frequency in Hz A = DC offset voltage (average voltage) B = Sine amplitude Vpp = 2B Vmax = A + B Vmin = A – B 120 VRMS from the AC line has a peak voltage of 170V has a PP voltage of 340V A = 0, B = 170, f = 60

Electrical Power and RMS voltage Electrical Power P = Voltage (V) x Current (I) Our dilemma: The average voltage value of a sinusoidal, square, triangular, or ramp waveform with no DC offset is 0V. P = ? P = V*I = V*V/R (As V↑, I↑ into a load. Ohm’s Law says V = I * R). To calculate the power produced by an AC voltage, we must use the effective voltage, called the "Root Mean Square voltage" (abbreviated VRMS). Effective VRMS is also called “True VRMS” by many instrument manufacturers. 120VRMS and 120VDC will produce the same power in a given load.

True VRMS from DMM measurements: (works with some meters for a sine wave with an offset) Take the VDC measurement. (This is A.) Note: your DMMY64 does not always read the DC component if there is significant AC present. Take VAC measurement. (This is ACRMS = B ∕ √2) Square VDC, square VAC, add them together, take the square root of the sum.

Remember this: sin(x) varies from -1 to +1 so Bsin(x) varies from –B to +B and (for voltages) Vpp = 2B The scope has an “Amplitude” measurement that is actually the same as Vpp. Amplitude on the scope ≠ B The DMMY64 assumes all time varying signals are sinusoids. This meter will provide an ACRMS measurement for pure sinusoids; it will not accurately measure anything that is not either pure DC or a pure sinusoid between 40Hz and 400Hz.

Oscilloscope Basics The scope graphically displays a time varying voltage waveform. The scope can be used to determine waveform amplitude, frequency, period, phase, DC and AC components, noise, shape, etc. NOTE: The oscilloscope is designed to capture and display time varying waveforms – it is not the best instrument for measuring DC voltages!

Displaying the input waveform. An A→D converter captures a series data points on the waveform. The 8 bit samples provide a resolution of 256 possible voltage levels. These points are stored in memory and then displayed on the screen, using interpolation to smooth the waveform shape between data points. The accuracy and resolution depend on the vertical scale selected. For best measurement accuracy, you should always try to display the waveform as close to full scale as possible.

Main Oscilloscope Components Vertical display controls Scales the input voltage to set the size and position of the waveform. Horizontal display controls Sets the “sweep rate” (time / division) and adds a horizontal position control. Trigger System and controls If the horizontal sweep begins randomly, the waveform moves around. The trigger stabilizes the waveform by controlling where, on a waveform’s voltage and slope, the display trace begins each time. This scope also has a built-in signal generator.

The Velleman scope display

Vertical controls Turn the channel display on & off (toggle the On button) Set the vertical scale (press desired scale on Volts/Div.) Set vertical position (slide bar) Set input coupling (select buttons at bottom) Set probe type (select buttons at bottom center) use 1x for the black coax probes from Electronix Express. use 1X or 10x for the probe supplied with Velleman scope Autoset can be friend or foe!

Scope Input Coupling Input coupling may be: DC Coupling displays all of a signal, including any DC offset. True RMS measurement requires DC coupling. AC coupling strips the DC component from a waveform, leaving only the time varying portion of the signal. GND disconnects the input signal.

Horizontal controls To the right of the waveform display area is the Time/Div. horizontal scale setting buttons. The Run button enables the Horizontal display. The single button is used to display a single horizontal capture. Below the waveform display area is a slide bar to move the waveform sideways along the horizontal scale.

Trigger controls Turn the trigger on and off (use the buttons). If the trigger is off, the display will free run. If the trigger is on and you see Waiting for trigger… Select the trigger source (buttons) Select whether to trigger on rising edge or falling edge of the waveform. (buttons) Adjust the trigger voltage level (slide bar) until you see Running.

Trigger markers tell you what the trigger is doing. There are markers on the edges of the scope waveform display that correspond to the waveform’s trigger voltage level trigger time (appears when you move the horizontal position slide bar to display the waveform before the trigger occurred)

Signal Generator built into the Scope Generates sine, square, and triangle waveforms, plus other functions. Select the waveform type with the buttons. Select frequency range with the buttons, then adjust the frequency with the slider For Amplitude and DC offset, adjust the levels with the sliders or type the values into the boxes. The generator output (here) is set for a 500Hz, 5Vpp sine wave with a 0.98V DC offset - into a high Z load.

Starting the oscilloscope Install the scope software from the Velleman web site - not the CD Install the USB drivers from Velleman web site - not the CD Attach the scope to the USB port Launch scope control software Start > Programs > Velleman > PcLab2000LT (You will probably want to make a shortcut)

What if the software doesn’t find the scope? You may see a pop-up that says you are in Demo mode because the software did not find the scope. This is usually not a problem. Click Options > Hardware Setup > PCSGU250 > OK The software will find the scope and the blue light will illuminate on the front of the scope.

If you still can’t get the scope to connect… Make sure that you installed the software and drivers from the Velleman website. The CD included with your scope does not contain the latest versions. Try re-installing the drivers from the Velleman web site. See the ECE Tech support Guru for assistance. Branden McKagen   bmckagen@vt.edu 346 Whittemore Hall 9:00-Noon and 1:30-5:00 Monday - Friday If you have a scope that will not work, see a GTA in the OpEL for assistance.

Your scope is connected, what now? First do a calibration. With no cables connected to the scope, Click Options > Calibrate > OK Wait for the Calibraion complete pop-up and click OK Always run a calibration before you begin measurements if the scope and/or computer have been off.

Connecting the Generator and Scope to a load Connect the probe leads from the scope CH1 input and the scope Generator output to the load resistor on the protoboard. Insert wires into the breadboard and clip the probe leads to the wires. Do not attach the measurement clips directly to the load resistor. The heavy probe leads may pull the resistor out of the breadboard Using wires makes it easier to change the resistor value.

Set up the scope’s Signal Generator Select the waveform type with the buttons. Select frequency range with the buttons, then adjust the frequency with the slider For Amplitude and DC offset, adjust the levels with the sliders or type the values into the boxes. In this case, the generator output is set for a 500Hz, 5Vpp sine wave with a 0.98V DC offset into a high Z load.

Set up the scope for measurements Connect a BNC / Clip lead from the signal to be measured to the CH1 and/or CH2 Input(s). Click Run. Turn on the Trigger and the CH1 and/or CH2 display(s). Adjust the vertical, horizontal, and trigger controls to get your waveform on the screen.

Visually measuring the waveform On the scope display, Vmax, Vmin, Vpp, and period can be obtained by counting the number of divisions multiplying by the vertical scale for voltages multiplying by the horizontal scale for time period.

Measure the Waveform Parameters Click View > Waveform Parameters… This opens a pop-up for meaurements. Click each box to place (or clear) a check for measurements you wish to include (or exclude). DC Mean is approximately the DC offset AC RMS is VRMS without the DC offset AC + DC RMS is the True VRMS Amplitude is the same as Peak-to-Peak

“Waveform Parameters” Accuracy A waveform that vertically occupies most of display will have more measurement accuracy than a waveform that is small on the display. Best accuracy seems to require at least two waveforms horizontally. The measured values will be reasonably accurate as long as the scope display is running. If you see “?” after the value, the waveform measurement does not fit into the display window and is out of measurement range. If you have “Waiting for trigger” showing, any waveform changes will not appear in the display or Waveform Parameters measurements.

Using Cursors To obtain data at specific points on the displayed voltage vs. time graphs, you can turn on the cursors by clicking on Markers (DSO) under View on the scope toolbar.

To find the difference in time between two points in time on a curve, position the two vertical lines by click-and-dragging each line to the appropriate point on the trace. dt is the absolute value of the difference in time between the two vertical cursors. 1/dt is the reciprocal of that difference in time, expressed in Hz .

To find the difference in voltage between two points on the same trace, position the two horizontal lines by click-and-dragging each line to the appropriate point on the trace. dV is the absolute value of the difference in voltage between the two horizontal cursors. The two voltages in parenthesis after dV are the voltages used in the calculation of dV .

You can use the cursors to find the difference in voltage between the two traces. However, you should make sure that the coupling on Channel 1 is the same as the coupling on Channel 2, DC coupling on both channels will enable you to measure the difference in voltage between the two traces using ground as a reference voltage. AC coupling will only allow you to determine the difference in the ac portion of each signal. You should not use two different types of coupling.