A Study of Proximity Focusing RICH with Multiple Refractive Index Aerogel Radiator A Study of Proximity Focusing RICH with Multiple Refractive Index Aerogel.

Slides:



Advertisements
Similar presentations
Study of 144-channel Hybrid Avalanche Photo-Detector for Belle II RICH Counter VCI2010 Susumu Shiizuka Nagoya University for Belle II Aerogel RICH group.
Advertisements

DPG 2004 Köln C. Schwarz Particle Identification with the PANDA detector at GSI C.Schwarz, GSI.
Barrel PID upgrade K. Inami (Nagoya-u) and PID group - R&D status - TOP counter - iTOP - Focusing DIRC - To do, cost estimation.
Peter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute The HERA-B RICH counter.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
CLAS12 – RICH PARAMETERDESIGN VALUE Momentum range3-8 GeV/c  /K rejection factor Not less than 500  /p rejection factor Not less than 100 Angular coverage5.
Makoto Tabata Japan Aerospace Exploration Agency (JAXA) TIPP 2011 in Chicago Recent Progress in Silica Aerogel Cherenkov Radiator.
PID Nagoya univ1 The possibility of improving TOP counter Nagoya university Yuji Enari.
Could CKOV1 become RICH? 1. Simulations 2. Sensitive area of the detection plane 3. Example of a workable solution 4. Geometrical efficiency of the photon.
TOF/ACC test Overview M. Yoshida Osaka Univ.. TOF / ACC in the prototype test For the prototype test in May, we will need PID: –TOF counter Distinguish.
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
Marco Musy INFN and University of Milano-Bicocca Pylos, June 2002 Aerogel as Cherenkov radiator for RICH detectors for RICH detectors.
T. Sumiyoshi (TMU) 30, Nov del Carmen 1 Development of HPD (HAP D) Photon-detector for the Aerogel RICH Photon-detector for the Aerogel.
The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 Shibata Lab 11R50047 Jennifer Newsham YSEP.
Peter Križan, Ljubljana March 17, 2006 Super B Workshop, Frascati Peter Križan University of Ljubljana and J. Stefan Institute Aerogel RICH and TOP: summary.
Position Sensitive SiPMs for Ring Imaging Cherenkov Counters C.Woody BNL January 17, 2012.
May 31, 2008 SuperB PID sessionMarko Starič, Ljubljana Marko Starič J. Stefan Institute, Ljubljana Report on hardware tests and MC studies in Ljubljana.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
Ichiro Adachi for the aerogel RICH R&D group KEK RICH Dec.01 Study of Highly Transparent Silica Aerogel as RICH Radiator Introduction Aerogel.
Study of a Silica Aerogel for a Cherenkov Radiator Ichiro Adachi KEK representing for the Belle Aerogel RICH R&D group 2007 October RICH2007, Trieste,
Status of Aerogel detector for high pT upgrade at PHENIX Budget from US-J project for next two years : (1) 400 liters of Aerogel (2) 600 photomultiplier.
Development of 144 Channel Multi-Anode HPD for Belle Aerogel RICH Photon Detector Development of 144 Channel Multi-Anode HPD for Belle Aerogel RICH Photon.
CLAS12 – RICH PARAMETERDESIGN VALUE Momentum range3-8 GeV/c  /K rejection factor Not less than 500  /p rejection factor Not less than 100 Angular coverage5.
A RICH with Aerogel for a hadron machine On behalf of the LHCb RICH group Some results and considerations on: Cerenkov angle resolution from aerogel Index.
J. Stefan Institute, Ljubljana Institute: Multidisciplinary institute, largest research institution in Slovenia Physics (solid state,
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
July 4, 2008 SuperBelle Meeting, KEKPeter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute Burle MCP PMTs as photon detector.
Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Peter Križan University of Ljubljana and J. Stefan Institute RICH counters for HERA-B and Belle.
Study of a Proximity Focusing RICH with Aerogel Radiator for Future Belle Upgrade Toru Iijima Nagoya University October 18, th International Workshop.
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) Feb Beijing Introduction Basic performances Future.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
KEK Test Beam Phase I (May 2005) Makoto Yoshida Osaka Univ. MICE-FT Daresbury Aug 30th, 2005.
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
“Tests of a proximity focusing RICH with aerogel as radiator” Toru Iijima / Nagoya University for Belle Aerogel-RICH R&D.
Tests of a proximity focusing RICH with aerogel as radiator and flat panel PMT (Hamamatsu H8500) as photon detector Rok Pestotnik Jožef Stefan Institute,
Aerogel RICH & TOP counter for super KEKB Y.Mazuka Nagoya University June 14-16, 2006 The 3 rd SuperB workshop at SLAC.
Peter Križan, Ljubljana Dec 7, 2007 Mini WS, SLAC Peter Križan University of Ljubljana and J. Stefan Institute Simulations for SuperBelle SuperB computing.
Cherenkov light imaging in particle and nuclear physics experiments [Toru Iijima (Nagoya), Blair Ratcliff (SLAC)] Cherenkov detectors in astroparticle.
Peter Križan, Ljubljana September 17, 2008 SuperB PID Peter Križan University of Ljubljana and J. Stefan Institute Forward PID: - SiPM as photon detectors.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
Preliminary Analysis of the New Focusing DIRC Prototype Beam Data
RICH2016 SESSIONS •Cherenkov light imaging in particle and nuclear physics experiments [Toru Iijima (Nagoya), Blair Ratcliff (SLAC)] •Cherenkov detectors.
Proximity focusing RICH with TOF capabilities for the Belle upgrade
Particle Identification (PID) at HIEPA Experiment
Highlights from RICH2007 PPD Seminar S.Easo, A.Papanestis, S.Ricciardi
CLAS12 – RICH RICH - TECHNICAL PARAMETERS PARAMETER DESIGN VALUE
PID Upgrade for Super-KEKB / Belle
Status of the PandaRoot simulation of the Forward RICH
R. DeLeo1,A. G. Argentieri2,T. Bellunato3,M. Calvi3,E. Cisbani4,F
FDIRC MC Studies: PMT Coupling Options
PCID – Projectile Charge Identification Detector
Focusing Aerogel RICH with SiPM Photodetectors
E.A.Kravchenko Budker INP, Novosibirsk, Russia
Focusing Aerogel RICH for PID and Momentum Measurement
Particle Identification in LHCb
Development and Construction of PHENIX Aerogel Cherenkov Detector
Upgrade magnets and power supplies
KEKB_Ring_3km_circumference
LHCb Particle Identification and Performance
T. Bowcock University of Liverpool For the LHCb Collaboration
E.A.Kravchenko on behalf Novosibirsk group
How can we study the magnetic distortion effect?
Development of the PANDA Forward RICH with an aerogel radiator
Performance test of a RICH with time-of-flight information
Presentation transcript:

A Study of Proximity Focusing RICH with Multiple Refractive Index Aerogel Radiator A Study of Proximity Focusing RICH with Multiple Refractive Index Aerogel Radiator 1 I. Adachi, 2 I. Bertović, 3 K.Fujita, 4 T. Fukushima, 2 A. Gorišek, 3 D. Hayashi, 3 T. Iijima, 3 K.Ikado, 5 M.Iwabuchi, 4 H. Kawai, 6,2 S. Korpar, 3 Y. Kozakai, 7,2 P. Križan, 4 A. Kuratani, 8 T. Matsumoto, 3 Y. Mazuka, 8 T. Nakagawa, 1 S. Nishida, 5 S. Ogawa, 2 R. Pestotnik, 8 T. Seki, 8 T. Sumiyoshi, 4 M. Tabata, 1 Y. Unno 1:IPNS, KEK, Tsukuba, Japan / 2:J.Stefan Institute, Ljubljana, Slovenia / 3:Dept. of Physics, Nagoya Univ., Nagoya, Japan / 4:Dept. of Physics, Chiba Univ., Chiba, Japan /5:Dept. of Physics, Toho Univ., Funabashi, Japan 6:Faculty of Chemistry and Chemical Engineering, Univ. of Maribor, Maribor, Slovenia 7:Faculty of Mathematics and Physics, Univ. of Ljubljana, Ljubljana, Slovenia / 8:Dept. of Physics, Tokyo Metropolitan Univ., Tokyo, Japan presented by Peter Križan Aerogel radiator Position sensitive PD with B=1.5Tesla Cherenkov photon 200mm n=1.05 Proximity Focusing RICH with Aerogel Radiator Developed for a new particle ID device in the Belle forward region improve  /K separation up to 4  at 4 GeV/c limited space operational under 1.5 Tesla magnetic field Key components Hydrophobic aerogel with refractive index of ~1.050 as a Cherenkov radiator Position sensitive photodetector with ~5x5mm 2 pixel size Electronics for read-out Belle detector Performance Test at 2002 Beam Experiment n=1.05 aerogel radiator  =14mrad Npe = 6 4  separation confirmed  4.0GeV “K”4.0GeV typical event RICH prototype counter Hamamatsu Multi-anode Flat-Panel PMT(H8500)  /K 4  separation at 4 GeV/c achieved with a prototype counter  need more photoelectrons for a further improvement as well as for more robustness HOW ? R&D project since 2000 Innovative idea to Get More Photoelectrons w/o Degrading Resolution Simple accumulation of aerogel layers allows to detect more Cherenkov photons, however it deteriorates overall resolution. n1n2 n1<n2 Employ multiple layers with different indices so that Cherenkov images from individual layers overlap on the photon detector. Concept Validation in Beam 4cm-thick single index aerogel   (1p.e.) = 22 mrad Npe ~ 10.6   (track) = 6.9 mrad Focusing by 2cm+2cm aerogel (n1:1.047, n2:1.057) n1 n2   (1p.e.) = 14.4 mrad Npe ~ 9.6   (track) = 4.8 mrad Novel idea of dual radiator “focusing scheme” has been proven  Only possible because refractive index of aerogel radiator can be adjusted in the production  Require further improvement of aerogel transparency not only for n=1.050 but for other indices Progress in Aerogel Radiator Production Measured index Transmission length at 400nm(mm) old synthesis method Transparency improvement for samples with n=1.040~1.060 Crack-free large sample has been made 110x110x20mm 3 150x150x20mm 3 n =1.050 refractive index control  n = index deviation from average Extension of the new concept: multiple layer radiator High accuracy of index is advantageous for dual/multiple layer radiator configurations 2001 sample Target index Averaged transmission length at 400nm     # of photoelectrons ▲ : single index layer ● : multiple layer 1st 2nd 3rd 4th 1st 2nd 3rd 4th ▲ : single index layer ● : multiple layer With new aerogels provided, we have examined the performance by stacking more layers during a 2005 beam test single photon resolution Comparison between single index and multiple radiator schemes(3.0 GeV/c pion beam) resolution per track best  (track) = 4.2 mrad We have succeeded in getting more Npe without an increase in the single photon uncertainty. Single index radiatorn = only Multiple layer radiator n1 = n2 = n3 = n4 = |  (  )-  (  )|/  (track) ~5.5  separation achieved for 4 GeV/c with Npe= 9.1 Progress on aerogel optical quality has been examined in test beam radiator thickness(cm) Npe 2001 sample 2005 sample Significant increase of Npe observed for 2005 sample, while old sample gets saturated around Npe~4.5 Transmission length at = 400nm more than doubled 10mV Conclusions 1.In 2004 we have introduced and tested a new technique which uses multiple aerogel tiles with different indices so that Cherenkov photons can be imaged to overlapping rings. With this configuration, we have demonstrated a 5.5   separation with ~9 photoelectrons in the 2005 beam test. 2.Optical quality of aerogel tiles has been significantly improved. As a result, photoelectron yield has been doubled. The radiator size can be enlarged by 86% and crack free sample was obtained. 3.We have tested additional time-of-flight capabilities of such a counter. Both Cherenkov photons from the aerogel radiator as well as from the PMT window can be used. The latter would allow to extend the PID capabilities of the counter to particles which are below the Cherenkov threshold in aerogel. References 1.T.Iijima et al., NIM A543(2001) T.Matsumoto, S.Korpar et al., NIM A521(2004) T.Iijima, S.Korpar et al., NIM A548(2005) I.Adachi et al., NIM A553(2005) P.Križan et al., physics/ , to be published in NIM A. Additional feature: RICH+TOF Idea: Make use of the fast photon detectors and measure time-of-flight with Cherenkov photons from aerogel and from the PMT window The Cherenkov photons from the window: can be used for particles below the threshold in aerogel  The separation in Belle should be even better: flight distance ~2m (instead of 0.7m in the beam test set-up). Beam test data: 50ps resolution per single photon  ~20ps per track ~38ps per track Separation of pions and protons at 2 GeV, flight distance 0.7m.