Integrated Technology!

Slides:



Advertisements
Similar presentations
INTRUSION ALARM TECHNOLOGY
Advertisements

Knells Door and Hardware SINCE 1906 Electronic Access Control Presentation.
CL100D series DSP controlled Uninterruptible power supplies.
SCW9057 Key Features/Benefits
Welcome to the Radionet Monitoring Secure-Com Presentation.
AIM Armstrong’s Intelligent Monitoring Training presentation.
XT30/XT50 Basic Training System Overview
Welcome to the Award Winning Easiest to Use & Most Advanced View, Manage, and Control Security, Access Control, Video, Energy & Lighting Systems, & Critical.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
1 RISCO Agility, PIR Cam & Cloud Combined Presentation.
New Featured Products Ronnie Pennington. eBridge100RMT - EoC Adapter Kit Faster Ethernet over Coax! Features/Benefits: Data rate 100Mbps full duplex Deploy.
WELCOME A Security Masterpiece. Control Panel Line-up Max Zones Basic Zones Max Zones Basic Zones n 1725EX14 6 (4 + 2) n 1728EX15 7 (5 + 2) n 1738EX16.
GS3055-I GSM Universal Wireless Alarm Communicator
1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property.
CERTIFICATON EN Wireless Fire Detection.
System Capacity MAP 5000 Release 1.2 Feature Overview
Alexor 2-way Wireless Security Suite Aitor Gauna – DSC European TST
Pyronix Ltd. Secure House Braithwell Way, Hellaby, Rotherham, S66 8QY, UK T F E
Remote Monitoring and Management Solutions ®
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
The Comfort System Product Presentation The Intelligent Home System.
DP Cabinet.
JA-63KRG PROFI GSM Alarm JA-63KRG PROFI What? security & home automation & communicationWhere? residential & business & special applications.
1 INTRUSION ALARM TECHNOLOGY WIRELESS SYSTEMS. 2 INTRUSION ALARM TECHNOLOGY Wireless systems use radio frequencies (RF) to connect sensors to the control.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Phaseo Power Supplies ACE Expert Training Presentation 2009.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Make your premises an Oasis of security Oasis_EN_1010_c1.
ONYX Product Overview.
INTRUSION ALARM TECHNOLOGY
1 Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
1 INTRUSION ALARM TECHNOLOGY KEYPADS (CONTROL UNITS)
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
RP-2000 Series Deluge & Agent Releasing Panels
Burglar & Fire Alarm Basics
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
GS2060/TL260GS Product Technical Training
Invision TAC™ Integrated Telephone Entry and Access Control System Product Introduction June 2010.
The Comfort System Product Presentation The Intelligent Home System Revised May 2009.
AZOR – easy solution GSM mini alarm Azor. AZOR - introduction Common alarm system = STRESSFUL Your home is changing to „PROTECTED PREMISES“ Complicated.
1 Sales Academy Training Inner Range Product Advantages, Competitors & The Future.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
HP900 (ESP Protocol) Analogue Addressable Control Panels
T-Link II Secure Internet Alarm Communication. Product Goals… High level encryption Software upgrades via network Universal compatibility Non-Static IP.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
Paradox Communication Solution GPRS / GSM
MG5000 / MG5050 Magellan 32-Zone Wireless Transceiver Control Panels Product Information.
MG6250 Magellan 2-Partition 64-Zone Wireless Console with GPRS/GSM
NFS System Components & Installation.
GS3055-I Installation Process
2 December, 2015 New Conventional Fire Control Panel.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Introducing VAX: Vicon’s New Access Control System.
COSEC ARC IP based Access Control Panel.
2N® Access Unit Touch Keypad
Slides include notes (more details about every slide information).
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
High Security and Access Systems
AIM Armstrong’s Intelligent Monitoring Training presentation.
MG6250 Magellan 2-Partition 64-Zone Wireless Console with GPRS / GSM.
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

Integrated Technology! MAXSYS Version 3.3 Integrated Systems Integrated Technology!

MAXSYS Version 3.3 Introduction The MAXSYS Panel: Integrated Product with Single Software Design Combines 4 Systems: Burglary Fire Access Control Automation Full Upload/Download Programming User-Friendly System Administration Software – DLS-3 SA Pt 1: All on ONE low-cost platform Pt 2: Minimal functional compromise, high performance reliability Pt 3: Result: lower component count, higher reliability, ultimately, LOWER COST Pt 4: Expand on ease of installation - how, why, benefits

MAXSYS Version 3.3 Introduction Overview: 16 Zone, Expandable to 128 Hardwire, Wireless, Addressable Expansion Maximum 16 LCD Keypads 8 Partitions 1500 User Codes 3000 Event Buffer Supervised Digital Communicator 3 Phone Numbers, 9 Account Numbers 1 Supervised Bell Output Local Upload/Download with PCLINK Connector

MAXSYS Version 3.3 Hardwire Expansion Hardwire: PC4108 Zone Expander 8 Hardwire Zones PC4116 Zone Expander 16 Hardwire Zones Connect any Number of Modules to Expand the System up to 128 Zones PC4108/4116

MAXSYS Version 3.3 Addressable Expansion Addressable: Two-Wire Addressable Loop PGM1 and PGM2 can both be used Each can provide up to 170 mA of current Connect up to 128 Addressable (AML) Detectors Does not require any additional modules Isolators and Repeaters Available AML-770 Isolator Module AMX-400 Isolator/Repeater Module

MAXSYS Version 3.3 Addressable Expansion Burglary Detectors AMB-300 Standard PIR AMB-500 Ceiling Mount PIR AMB-600 Pet Immune PIR AMA-100 Glassbreak Detector Fire Detectors AMP-700/701 Contact Modules AMS-220 Smoke Detector AMP-702 Fire Input Module

MAXSYS Version 3.3 Addressable Expansion Use 2-wire addressable loops to easily expand to full system capacity without the added cost of system expansion modules. AMS-220 AMP-701 AMB-500 AMB-300 AML-770 The AML-770 can be used to isolate fire detectors from burglary detectors so they can be connected to the same wire run. AMX-400 The AMX-400 can be used to repeat the data loop – allowing for longer wire runs. In addition, it will isolate the loop in the event of a problem. AMA-100 AMB-600

MAXSYS Version 3.3 Wireless Expansion Wireless: Supports up to 64 Wireless Zones Supports up to 16 Wireless Keys Wireless keys do not use up zones Uses the PC4164-433 MHz Wireless Receiver Module Connect up to 8 PC4164-433 Modules for: Distributed wireless reception Larger coverage area Allows users to move through larger area with wireless panic pendants and wireless keys without being out of range

Low Temperature Sensor MAXSYS Version 3.3 Wireless Expansion Connect up to 8 PC4164-433 Modules Total number of wireless zones is 64 Total number of wireless keys is 16 WLS904PL Pet Immune Motion WLS906 Smoke Detector PC4164-433 Wireless Receiver WLS914 Pet Immune Motion WLS918 Panic Pendant WLS919 Wireless Key WLS907T Low Temperature Sensor WLS912L Glassbreak Detector WLS925L Door/Window Contact

MAXSYS Version 3.3 COMBUS COMBUS: Bi-Directional RS-485 Communication Bus for Modules Four wire, non-shielded cable Red/Black for power, Yellow/Green for data All Modules Connect to the COMBUS Modules can be home run, daisy-chained, t-tapped Total wire used cannot exceed 5,000 feet Additional Power Supplies Available PC4204 – power supply with 4 relay outputs PC4204CX – power supply/COMBUS repeater with 4 relay outputs

MAXSYS Version 3.3 Modules

MAXSYS Version 3.3 Burglary Modules Keypads: LCD4500 LCD Keypad Programmable Alphanumeric Keypad LCD4501 LCD Keypad 5 Programmable Function Keys Connect up to 16 Keypads Maximum

MAXSYS Version 3.3 Burglary Modules Zone Expanders: PC4108 Zone Expander 8 Hardwire Zones PC4116 Zone Expander 16 Hardwire Zones Current Draw – 30 mA AUX Output to Provide Power for Detectors

MAXSYS Version 3.3 Burglary Modules Output Modules: PC4204 Power Supply 1 Amp Power Supply PC4204CX Power Supply 1 Amp Power Supply (40 VA transformer) 2.2 Amp Power Supply (80 VA transformer) COMBUS Repeater Modules Supervised for Low Battery, AC Failure and Aux Output Failure Modules have 4 Programmable High Current Relays

MAXSYS Version 3.3 Burglary Modules Output Modules: PC4216 Output Module Provides 16 Low Current Outputs Outputs Rated at 50 mA Connect up to 9 Modules for 144 Outputs Typically Used for Annunciation PC4632 – 32 Point Annunciator 8 ½ x 11 inch display area PC4664 – 64 Point Annunciator 11 x 17 inch display area

MAXSYS Version 3.3 Fire Modules Fire Features All 128 Zones can be used for Fire Hardwire or Addressable Dual Phone Line Dialer Module 24 VDC Notification Appliance Outputs Annunciators Auto-Scroll Alarms Fire Inspector Test User Initiated Fire Drill

MAXSYS Version 3.3 Fire Modules Keypads: LCD4520 LCD Fire Keypad Programmable Alphanumeric Keypad LCD4521 LCD Fire Keypad 5 Programmable Function Keys Connect up to 16 Keypads Maximum

MAXSYS Version 3.3 Fire Modules Annunciators: PC4612 Fire Annunciator 10 Fire Zones, 2 Supervisory Zone, Bell and System Trouble AC Indicator PC4632/PC4664 Annunciators 32 or 64 Point Annunciators Uses PC4216 Modules (up to 4)

MAXSYS Version 3.3 Fire Modules Dialer Module: PC4701 Two Line Dialer Module Includes: Connection for two Separate Phone Lines One 2-Wire, Class B/Style B Smoke Detector Zone One Class B/Style B Waterflow Zone Form ‘C’ Fire Alarm Relay Form ‘C’ Fire Trouble Relay

MAXSYS Version 3.3 Fire Modules Output Module: PC4702BP Bell Panel Up to 4 Modules per System Two Alarm Notification Outputs 24 VDC, 1.8 Amps each Outputs supervised PTC Protected Outputs will self-restore when problem corrected Includes 28 Volt, 180 VA Transformer Red Cabinet

MAXSYS Version 3.3 Fire Modules Power Supply: PC4204CF Power Supply Up to 16 Modules per System Provide up to 1 Amp Fully Supervised for: Low battery, AC failure, AUX output failure Four Programmable High Current Relays Includes 16 Volt, 40 VA Transformer Red Cabinet

MAXSYS Version 3.3 Fire Modules Battery Charger: PC4350 External Battery Charger Includes: PC4085 Charger Module Red Cabinet 16 VAC, 80 VA Transformer Used to Charge up to 60 Ah of Batteries Auto Shutdown to Prevent Battery Deep Discharge Supervised for AC Failure

MAXSYS Version 3.3 Access Control Features Up to 32 Readers 1500 Users 64 Access Levels 99 Date Schedules, 4 Interval Each 4 Holiday Groups Scheduled Options Including: Door Unlock REX Input Code Required Door Forced Door Open Too Long Arm Request Disarm Request

MAXSYS Version 3.3 Access Control Modules Controller: PC4820 Access Control Module Up to 16 Modules per Panel Each module supports up to 2 Readers Supervised Lock Output Power, 250 mA Inputs: Door Contact, REX, Arm and Postpone Arm Outputs: LED, Buzzer ‘Failsoft’ Operation Operates if communication is lost with control panel

MAXSYS Version 3.3 Access Control Modules Readers: Multiple Reader Technology Support: Polaris ShadowProx HID IoProx Different Technology Readers can be used on one System

MAXSYS Version 3.3 Access Control Modules Controller: PC4850 Lobby Controller Apartment Building Entry Control Gate Control Up to 16 Modules per Panel Electronic Directory up to 1500 Users Controls up to 2 Doors ‘Failsoft’ Operation Operates if communication is lost with control panel Internal 128 Event Buffer PC4851 ‘No Phone Bill’ Option

MAXSYS Version 3.3 Automation Features Telephone Interface Control panel using any touchtone telephone Interface for Power Line (X-10) Devices Intercom Verbal Chime Verbal Alarm

MAXSYS Version 3.3 Automation Modules Telephone Interface Escort4580 Telephone Interface Module Turns any Touchtone Telephone into a Talking Keypad Local or Remote Access Multiple Language Available Get Verbal System Status Arm, Disarm and Perform Other User Functions 240 Word Library for Labels (zones, partitions, automation items) Interface for Power Line (X-10) Devices Control up to 32 Automation Devices

MAXSYS Version 3.3 Automation Modules Intercom PC4936 Intercom Module 7 Station Intercom Module Indoor and Outdoor (doorbell) Stations Available Features Include Page/Answer, Doorbell, Do not Disturb Supports Central Station Listen-In and Two-Way Expandable to 15 Stations with PC4937 Module When used with Escort4580 Features Include: Verbal Door Chime Verbal Alarm Annunciation

MAXSYS Version 3.3 Miscellaneous Features DataLink Bi-Directional RS232 Control Alternate Communications Skyroute T-Link Downloading

MAXSYS Version 3.3 DataLink DataLink PC4401 Serial Interface Module Supports Bi-Directional RS232 Control Provides System Integrators with Real-Time Events Panel will send panel status real-time Provides System Integrators with Real-Time Control Commands can be sent to the panel such as arm, disarm and bypass

MAXSYS Version 3.3 Cellemetry Communicator Cellemetry Communicator SkyrouteMAX Cellemetry Communicator Redundant Alarm Communication via Cellemetry Data Service Uses Control Channel of Existing Cellular Network Connects Directly to Panel COMBUS Can Report all Events by User Code, Zone Fully Supervised Signal Strength Indicator

MAXSYS Version 3.3 Network Interface T-Link Module T-Link TCP/IP Module Connects to Panel PCLINK Connector Used on LAN or WAN of User Can be used with Reporter IP Software for Local Reporting Can be used with Sur-Gard Receiver to Report via Network to the Central Station Can be used for End User Downloading

MAXSYS Version 3.3 Miscellaneous UL Listings: UL365, UL1635 Police station alarm units (Commercial burglary) UL1610, UL1635 Central station alarm units (Commercial burglary) UL609, UL1635 Local alarm units (Commercial burglary) UL1023 Household burglar alarm system units UL985 Control units & accessories - Household system UL864 Control units system (Commercial Fire) UL294 Access control system units International Listings: CE – EN60950; EN50130-4; EN55022 Class B CTR-21 CSFM

MAXSYS Version 3.3 Summary Dealer Benefits: Secure larger portion of installation One system to learn and maintain Opportunity for post-installation expansion sales Lower system cost + simplified installation = HIGHER PROFITS Third party system integration End User Benefits: Product grows with customer’s changing needs One system to learn - plain language keypads One installer to call = reduced maintenance headaches Most cost-effective multiple system solution Windows™-based System Administration Software