Proposal for a new design of LumiCal R. Ingbir, P. Ruzicka, V. Vrba -1-. 31. October 07 Malá Skála.

Slides:



Advertisements
Similar presentations
Beam-plug and shielding studies related to HCAL and M2 Robert Paluch, Burkhard Schmidt November 25,
Advertisements

Advanced GAmma Tracking Array
Background effect to Vertex Detector and Impact parameter resolution T. Fujikawa(Tohoku Univ.) Feb LC Detector Meeting.
Geant4 simulation of roman pots A. Kupco, P. Ruzicka, M. Tasevsky.
Simulation Studies of a (DEPFET) Vertex Detector for SuperBelle Ariane Frey, Max-Planck-Institut für Physik München Contents: Software framework Simulation.
LHCb PatVeloTT Performance Adam Webber. Why Upgrade?  Currently we de-focus the beams o LHCb Luminosity ~ 2x10 32 cm -2 s -1 o ~ 1 interaction per bunch.
Angular resolution of LAT Agnieszka Kowal University of Science and Technology, Cracow TESLA Workshop on Forward Calorimetry Cracow, 10 October 2003.
P hysics background for luminosity calorimeter at ILC I. Božović-Jelisavčić 1, V. Borka 1, W. Lohmann 2, H. Nowak 2 1 INN VINČA, Belgrade 2 DESY, Hamburg.
1 N. Davidson E/p single hadron energy scale check with minimum bias events Jet Note 8 Meeting 15 th May 2007.
1 Hadronic In-Situ Calibration of the ATLAS Detector N. Davidson The University of Melbourne.
The SLHC and the Challenges of the CMS Upgrade William Ferguson First year seminar March 2 nd
The LiC Detector Toy M. Valentan, M. Regler, R. Frühwirth Austrian Academy of Sciences Institute of High Energy Physics, Vienna InputSimulation ReconstructionOutput.
Effect of the Shape of the Beampipe on the Luminosity Measurement September 2008 Iftach Sadeh Tel Aviv University DESY.
1 LumiCal Optimization and Design Takashi Maruyama SLAC SiD Workshop, Boulder, September 18, 2008.
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Krakow2006.
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Cambridge ILC software tools meeting.
Thomas Jefferson National Accelerator Facility Page 1 EC / PCAL ENERGY CALIBRATION Cole Smith UVA PCAL EC Outline Why 2 calorimeters? Requirements Using.
Jan MDI WS SLAC Electron Detection in the Very Forward Region V. Drugakov, W. Lohmann Motivation Talk given by Philip Detection of Electrons and.
Karsten Büßer Beam Induced Backgrounds at TESLA for Different Mask Geometries with and w/o a 2*10 mrad Crossing Angle LCWS 2004 Paris April 19 th 2004.
Analysis of Beamstrahlung Pairs ECFA Workshop Vienna, November 14-17, 2005 Christian Grah.
International Workshop on Linear Colliders, Geneve Muon reconstruction and identification in the ILD detector N. D’Ascenzo, V.Saveliev.
Yosuke Watanabe….. University of Tokyo, RIKEN A, KEK C, Development of a GEM tracker for E16 J-PARC 1 Thanks to ???????????
Impact parameter resolution study for ILC detector Tomoaki Fujikawa (Tohoku university) ACFA Workshop in Taipei Nov
Simulation of physics background for luminosity calorimeter M.Pandurović I. Božović-Jelisavčić “Vinča“ Institute of Nuclear Sciences, Belgrade, SCG.
Ivan Smiljanić Vinča Institute of Nuclear Sciences, Belgrade, Serbia Energy resolution and scale requirements for luminosity measurement.
September, 19 FCAL Worlshop in Tel Aviv W. Lohmann, DESY Physics Requirements Input From Theory Lessons from LEP LumiCal Simulations BeamCal.
Development of a Particle Flow Algorithms (PFA) at Argonne Presented by Lei Xia ANL - HEP.
ILC-ECFA Workshop Valencia November 2006 Four-fermion processes as a background in the ILC luminosity calorimeter for the FCAL Collaboration I. Božović-Jelisavčić,
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Coil and HCAL Parameters for CLIC Solenoid and Hadron-calorimetry for a high energy LC Detector 15. December LAPP Christian Grefe CERN.
Positional and Angular Resolution of the CALICE Pre-Prototype ECAL Hakan Yilmaz.
Feasibility Study of Forward Calorimeter in ALICE experiment Sanjib Muhuri Variable Energy Cyclotron Centre Kolkata.
Optimization of the Design of the Forward Calorimeters ECFA LC Workshop Montpellier, 15 November 2003 *FC Collaboration: Colorado, Cracow, DESY(Zeuthen),
A Clustering Algorithm for LumiCal Halina Abramowicz, Ronen Ingbir, Sergey Kananov, Aharon Levy, Iftach Sadeh Tel Aviv University DESY Collaboration High.
A Luminosity Detector for the Future Linear Collider Ronen Ingbir Prague Workshop HEP Tel Aviv University.
Impact parameter resolutions for ILC detector Tomoaki Fujikawa (Tohoku university) ACFA Workshop in Taipei Nov
Silicon sensors for LumiCal Two possible options Wojciech Wierba Institute of Nuclear Physics PAN Cracow.
HEP Tel Aviv University LumiCal (pads design) Simulation Ronen Ingbir FCAL Simulation meeting, Zeuthen Tel Aviv University HEP experimental Group Collaboration.
Pad design present understanding Tel Aviv University HEP Experimental Group Ronen Ingbir Collaboration High precision design Tel-Aviv Sep.05 1.
BESIII EMC Simulation & Reconstruction He Miao
CP violation in B decays: prospects for LHCb Werner Ruckstuhl, NIKHEF, 3 July 1998.
1 Hadronic calorimeter simulation S.Itoh, T.Takeshita ( Shinshu Univ.) GLC calorimeter group Contents - Comparison between Scintillator and Gas - Digital.
HEP Tel Aviv UniversityLumical - A Future Linear Collider detector Lumical R&D progress report Ronen Ingbir.
The Luminosity Calorimeter Iftach Sadeh Tel Aviv University Desy ( On behalf of the FCAL collaboration ) June 11 th 2008.
1 LumiCal Optimization Simulations Iftach Sadeh Tel Aviv University Collaboration High precision design May 6 th 2008.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
07/24/07 Francisco Carrion OPTIMIZING THE TRACK DETECTOR Francisco Javier Carrión Ruiz Mentor: Hans Wenzel 07/08/09 SID CONCEPT FOR THE INTERNATIONAL LINEAR.
Fast and Precise Luminosity Measurement at the ILC Ch.Grah LCWS 2006 Bangalore.
Tungsten-Silicon Luminosity Detector with Flat Geometry Ronen Ingbir Tel Aviv University High Energy Physics Experimental Group.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
1/24 SiD FCAL Takashi Maruyama Tom Markiewicz SLAC TILC’09, Tskuba, Japan, April 2009 Contributors: SLAC M. BreidenbachFNALW. Cooper G. Haller K.
September 2007SLAC IR WS Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY Talks by M. Morse, W. Wierba, myself.
LumiCal background and systematics at CLIC energy I. Smiljanić, Vinča Institute of Nuclear Sciences.
Performance Study of Pair-monitor 2009/06/30 Yutaro Sato Tohoku Univ.
1 LoI FCAL Takashi Maruyama SLAC SiD Workshop, SLAC, March 2-4, 2009 Contributors: SLAC M. BreidenbachFNALW. Cooper G. Haller K. Krempetz T. MarkiewiczBNLW.
HEP Tel Aviv University Lumical R&D progress report Ronen Ingbir ECFA - Durham2004 Lumical - A Future Linear Collider detector.
FCAL Krakow meeting, 6. May LumiCal concept including the tracker R. Ingbir, P.Růžička, V. Vrba.
Study of the Differential Luminosity Spectrum Measurement using Bhabha Events in 350GeV WANG Sicheng 王 思丞 Supervisor: André Sailer.
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
LumiCal High density compact calorimeter at the ILC Wojciech Wierba Institute of Nuclear Physics PAS Cracow, Poland.
Initial proposal for the design of the luminosity calorimeter at a 3TeV CLIC Iftach Sadeh Tel Aviv University March 6th 2009
FCAL R&D towards a prototype of very compact calorimeter
Luminosity Measurement using BHABHA events
Layout of Detectors for CLIC
Huagen Xu IKP: T. Randriamalala, J. Ritman and T. Stockmanns
Studies with PandoraPFA
Rick Salcido Northern Illinois University For CALICE Collaboration
Michele Faucci Giannelli
LAT performance studies
Presentation transcript:

Proposal for a new design of LumiCal R. Ingbir, P. Ruzicka, V. Vrba October 07 Malá Skála

LumiCal Calorimeter in very forward region of ILC Designed for luminosity measurement Luminosity is measured by counting Bhabha events (e + e - → e + e - +  ) in small angles Precision luminosity measurement requires high angle and energy resolution October 07 Malá Skála

Motivation New design concept Algorithm Performance Luminosity measurement Summary October 07 Malá Skála Improve the performance of the LumiCal:  improve the energy reconstruction  improve the angle reconstruction Outline

New concept October 07 Malá Skála LumiCal is composed from two components: Tracker, Calorimeter A silicon tracker with fine granularity stands in front of the calorimeter Silicon tracker Calorimeter (various tungsten thickness) Calorimeter has various tungsten thicknesses

Strip silicon tracker Tracker start227 cm Tracker ends238 cm Number of layers5 Gap between the layers20 mm Silicon thickness0.3 mm Size of the strips70 μm Inner radius80 mm Outer radius350 mm Strips are used because of less channels in comparison with pads There is no electronic and cooling system behind silicon layers when we use the strips => smaller multiple scattering We use the information from the calorimeter behind the tracker to reconstruct the tracks in the tracker In this study we use 5 layers of θ measurement but in future we will add layers of φ measurement October 07 Malá Skála

Shower-peak design calorimeter Shower-peak design calorimeter LayerTungsten thickness [mm] LayerNumber of cylindersNumber of sectors October 07 Malá Skála Start z-position238 cm End z-position258 cm Outer radius350 mm Inner radius80 mm Silicon thickness0.3 mm Electronic thickness2.3* mm Calorimeter has 30 silicon layers Total tungsten thickness is equal 35 X0

Algorithm: Deposited energy in layers 1-20 with thickness 1 X0 has  i = 1 Deposited energy in layers with thickness 1.5 X0 has  i = 1.5 Energy reconstruction algorithm For calorimeters with various tungsten thicknesses we apply different weight factors for the different layer…… October 07 Malá Skála

Position algorithm 1. Compute  (polar angle) from the calorimeter:  calor is found using the logarithmic algorithm 2. Match  of the tracker: In first layer try to find hit strips in angle  calor ± d  1, where  calor was found before. If one or more strips are found then look for a match in the next layer in angle  prevlayer ± d  2, where  prevlayer was completed before. Only if all layers are matched the tracker information is used else take θ from calorimeter October 07 Malá Skála

Tracking algorithm R i …………..radial position of the particle in layer Z i …………..z position of the layer  i ………….. error in R measurement of the hit If more than one strip in the layer is hit compute R, as where  i =1. Choosing the  : If only one strip in a layer is hit then  1 ~ strip size (70 μm) If two or more strip a in layer are hit we have more information (needs optimization) The results presented today are for  i = October 07 Malá Skála

Calorimeter performance Calibration and energy resolution October 07 Malá Skála

Calorimeter performance Polar resolution and bias October 07, Malá Skála

Calorimeter performance Polar resolution and bias October 07 Malá Skála

Estimation of tracker parameters  (  ) remains constant ~ 2.5  rad Octomber 07 Malá Skála Strip size …………. 70 μm Silicon thickness ….0.3 mm Gap ……………… mm Number of layers … 5 Silicon thickness …..0.3 mm Gap ……………… mm

Silicon tracker efficiency Octomber 07 Malá Skála Percentage of events reconstructed in tracker:

New LumiCal polar reconstruction Octomber 07 Malá Skála

Luminosity measurement October 07 Malá Skála Beam energy [GeV]  L/L    High statistics studies of luminosity error The angle  gen was generated using BHWide Fast detector simulation was done using the results presented in previous page. Then the luminosity error was then computed as where, N gen …………..number of particle generated in acceptance region N rec ………….. number of particle reconstructed in acceptance region

Summary Summary A new concept of LumiCal was studied. First results were obtained. It was done in stand alone G4. A new concept of LumiCal was studied. First results were obtained. It was done in stand alone G4. Similar energy resolution (slightly better) was obtained using the varying tungsten structure - further design optimization is needed Similar energy resolution (slightly better) was obtained using the varying tungsten structure - further design optimization is needed Significant improvement in polar resolution about factor of 5-10, was obtained using the tracker information Significant improvement in polar resolution about factor of 5-10, was obtained using the tracker information Improvement in the theta bias of about a factor of , without energy dependent was obtained using the tracker information. Improvement in the theta bias of about a factor of , without energy dependent was obtained using the tracker information. The new design leads to better performance. The estimated error in luminosity is about and even better for the higher energies. The new design leads to better performance. The estimated error in luminosity is about and even better for the higher energies October 07 Malá Skála

Thank you for your attention October 07 Malá Skála Furthered optimization of the new design is required (thickness of the silicon, gap between the layers, size of the tungsten, size of the pads,… ). After optimization we expect even better performance. Furthered optimization of the new design is required (thickness of the silicon, gap between the layers, size of the tungsten, size of the pads,… ). After optimization we expect even better performance. Further optimization of the parameters in the algorithm (different weight, better matching algorithm,…). Further optimization of the parameters in the algorithm (different weight, better matching algorithm,…). Study the new design in more real environment including background and electronic simulation. Study the new design in more real environment including background and electronic simulation. Summary - outlook Summary - outlook