CMC3 ‘Hydromate’ Mexico March 2009. PRODUCT DESCRIPTION ‘State of the art’ stream gauging computer‘State of the art’ stream gauging computer Completely.

Slides:



Advertisements
Similar presentations
SATHUNTER Satellite pointing made easy DVB-S2 DVB-S.
Advertisements

Ranger Explorer Operations Guide ELearning Module Ver
Smart.IC II project Forklift truck connection Forklift truck connection, outside of the connector Automatic data download through GPRS and anlaysis of.
X-Call Version V3.0 User Guide
inFire HTC speed Furnace Webinar
Chapter 3 Creating a Business Letter with a Letterhead and Table
CAN HELP iPC1550KP Keypad and Reprogramming Overview.
Box Label System.
DAP-1520 FAQ’s Wireless AC750 Dual Band Range Extender.
Using Microsoft Office Excel 2007
Unit Test Calibration Training
Data Collection Device (DCD) Job Aid – Burn-in In DOIS Log onto DOIS. Click Options on the DOIS menu bar. Click on Utilities. Click DCD Software Burn-In.
PVD100 ‘Point Velocity Display’ Kota Samarahan Kuching, Sarawak July 2008.
Word Lesson 1 Microsoft Word Basics
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
DESCRIBING INPUT DEVICES
This document guides you through using the common features of the InFocus™ Mondopad™ touchscreen display located in this room. Getting Started Power Display.
Discharge Measurement Concepts September 2011 – Glen Hess,TESNAR, Oregon (Many slides from USGS Surface Water Field Techniques May 2008 Class)
1 Training Manual: KI7400 & 7800 Series Sources Level 1, V2.0 August 2008.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
Discharge Measurement Concepts September 2012 – Glen Hess,TESNAR, Oregon (Many slides from USGS Surface Water Field Techniques May 2008 Class)
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
WinTR-20 Project Formulation Hydrology Computer Program Basic Input and Output Presented by: WinTR-20 Development Team.
WinTR-20 Project Formulation Hydrology Computer Program Basic Input and Output Presented by: WinTR-20 Development Team.
Strengthening Supportive Supervision Training for Supervisors Session 3: Smartphones, introduction to SS Tool.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
1 BRIDGEPAD (BP) SYSTEM TRAINING Adapted for ScoreBridge Users By John de Ridder PSBC Revised 2 November 2009.
Creating Your PE Webshop Using SmartStore.biz This Tutorial assumes you have downloaded the software from This tutorial is based.
Spreadsheets and Microsoft Excel. Introduction n A spreadsheet (called a worksheet in Excel) is a two-dimensional array of cells containing data to be.
European Computer Driving Licence Syllabus version 5.0 Module 4 – Spreadsheets Chapter 22 – Functions Pass ECDL5 for Office 2007 Module 4 Spreadsheets.
Dynatest LWD Program - Sections
1 Sport-Ident 102 Part 4 Barry McCashin Edmonton Overlanders Orienteering Club Jan 18, 2009 UofA-BioSci © BGMcC 2009 Part 4: Other Topics 22 slides.
White Knight Tap Locator HJ Arnett Industries, LLC Portland, OR
 Starting Excel 2003  Using Help  Workbook Management  Cursor Management  Manipulating Data  Using Formulae and Functions  Formatting Spreadsheet.
Optical Manufacturing Solutions 1 FOLLOW THE DIRECTIONS BELOW AFTER INSTALLING A NEW CUTTER BODY WITH POLISHING WHEELS INTO THE 7E TYPE MACHINES. IT IS.
Technology ICT Core: Spreadsheets. Spreadsheets A spreadsheet is a table consisting of Rows and Columns Where a row and a column meet, the box is called.
InDesign CS3 Lesson 4 ( Only pages ) Importing and Editing Text.
Setting Up an on-line Store Tutorial Using SmartStore.biz This Tutorial assumes you have downloaded the software from This Tutorial.
Cypress-Fairbanks I.S.D. 04/04/05 1 QUICK PAD PRO TRAINING MODULE.
AutoCAD 培训教程 Text and Text Styles  Chapter Objectives  Text Styles  Creating a Text Style  Key Terms  Process Overview: Determining Text Height.
WORKBOOK FORMATTING Nolan Tomboulian Tomboulian.wikispaces.com HOW THINGS LOOK CELL COLORFONT COLOR CELL BORDERSFONT SIZE CELL SIZEFONT.
Resetting Student PreTests. Within the MyNursingLab Study Plans, pretests can be taken only one time by the student.
COMPARISON OF VARIOUS TYPES TypeFunctions CMC Sp Pulse + time + velocity PVD100 Hydromate CMC3 Pulse + time + velocity + discharge.
Getting Started with PDAs CALS PDA Initiative ALS 103.
1 THE VICTOR READER WAVE ● Plays DAISY books as well as music and books on MP3 or audio CD ● Powerful navigation features ● Go directly to any page number.
Microsoft Expression Web-Illustrated Unit E: Working with Pictures.
1 THE VICTOR READER VIBE. 2 Getting to Know Your Vibe Machine Basics The Vibe has eleven keys that are positioned in a clockwise format Each key has a.
Course 6: Analyzing AVO/AVA Analysis. Use gassman’s equations to predict velocity Objective accurately predict changes in amplitude.
Features and Specs 512 Channels 32 Groups of 16 Channels High/Low Power 5 Watts High 2 Watts Low Multi-line Alphanumeric Display 3 year warranty.
HydroTab Combines proprietary Hydrological Services Pty Ltd software with ‘Samsung Galaxy Tab Active’ hardware Stream Discharge Application.
JDS5 Training Guide. On Start Up you will see this screen click the OK button Click OK.
Introduction to Drafting and Design In order to begin our drawing we have to set the drawing limits or the paper size.
Microsoft Office 2013 Try It! Chapter 4 Storing Data in Access.
1 Word Lesson 1 Microsoft Word Basics Microsoft Office 2010 Introductory Pasewark & Pasewark.
1 Lesson 18 Getting Started with Excel Essentials Computer Literacy BASICS: A Comprehensive Guide to IC 3, 4 th Edition Morrison / Wells.
Forge Echo Introduction. Base Package Getting to know the device G – Sensor Calibration F4 Key Assignment Application F4 Distance Application F4 Height.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
© 2005 Avaya Inc. All rights reserved. Avaya – Proprietary & Confidential. For Limited Internal Distribution. The information contained in this document.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Word Processing vocabulary (a day) & (b day) Put the vocabulary words in your notebook.  Alignment - The way multiple lines of text line.
Submitted by: DRPU Software Team Site:
CI-202 Leaf Area Meter Instrument Training Conducted by: Brienne Meyer
Features 70” 700cd, Double double-sided outdoor dustproof digital monitor Anti-reflection tempered, vandal proof glass Outdoor weather proof: -30C to 45C.
C1300 advanced circular chart recorder
Enhancing a Document Part 1
Enhancing a Document Part 1
OdaStat-G – Getting Started with the OdaLog Type L2
Configuration Of A Pull Network.
Fluvial Hydraulics CH-3
Presentation transcript:

CMC3 ‘Hydromate’ Mexico March 2009

PRODUCT DESCRIPTION ‘State of the art’ stream gauging computer‘State of the art’ stream gauging computer Completely ‘paperless’Completely ‘paperless’ Fan equations easily stored in unitFan equations easily stored in unit Automatic calculation and display of cross-sectional area, mean velocity and dischargeAutomatic calculation and display of cross-sectional area, mean velocity and discharge Data downloaded as a ‘text’ or ‘csv’ file to database in officeData downloaded as a ‘text’ or ‘csv’ file to database in office Powered by ‘D’ cell rechargeable batteries (2x1.5V)Powered by ‘D’ cell rechargeable batteries (2x1.5V) ‘Non’ volatile memory‘Non’ volatile memory Software available in either English or Spanish versionsSoftware available in either English or Spanish versions

Mechanical Features Weight:1.5kgWeight:1.5kg Operating Temperature :-5 degrees C degrees COperating Temperature :-5 degrees C degrees C Humidity: % WaterproofHumidity: % Waterproof Enclosure Rating: IP65Enclosure Rating: IP65 Waterproof Case Dimensions: 210mm x 170mm x 90mmWaterproof Case Dimensions: 210mm x 170mm x 90mm

Electronic Features Internal rechargeable batteries (mains and car charger provided)Internal rechargeable batteries (mains and car charger provided) Standard connection of FanStandard connection of Fan RS232 serial port for PC operated configurationRS232 serial port for PC operated configuration Graphics LCD and TouchscreenGraphics LCD and Touchscreen Easily upgradeable to new software versionsEasily upgradeable to new software versions Backlighting’ of LCD‘Backlighting’ of LCD

Technical Features Discharge for up to 30 Sites can be measuredDischarge for up to 30 Sites can be measured Up to 30 verticals per site and up to 11 points per verticalUp to 30 verticals per site and up to 11 points per vertical Measures both instantaneous and average water velocityMeasures both instantaneous and average water velocity Calibration formulas for up to 32 Fans stored in ‘non-volatile’ memoryCalibration formulas for up to 32 Fans stored in ‘non-volatile’ memory Either ‘Mean’ or Mid-Section’ computation options availableEither ‘Mean’ or Mid-Section’ computation options available Fully charged gives 20hrs operation (no backlight) OR 5hrs (with backlight)Fully charged gives 20hrs operation (no backlight) OR 5hrs (with backlight)

Maintenance Do NOT charge Hydromate if alkaline batteries are installedDo NOT charge Hydromate if alkaline batteries are installed Do NOT use ballpoint pen on touch screenDo NOT use ballpoint pen on touch screen Do NOT use excessive finger pressure on touch screenDo NOT use excessive finger pressure on touch screen Do NOT charge the Hydromate while it is operatingDo NOT charge the Hydromate while it is operating ‘Clean the Touchscreen feature’ (when unit is operating) ‘Clean the Touchscreen feature’ (when unit is operating)

External Connectors Fan connection (banana type plugs) Fan connection (banana type plugs) RS232 / Charger port ON / OFF button

Hydromate Operation After first press of ON/OFF button, this screen will appear

Screen Customisation Normal Operation Upside Down View Left hand operator Right hand operator

Data Entry Press ‘Change’ - cycle between selections OR - numeric key pad OR - numeric key pad OR - alphanumeric keypad will appear - alphanumeric keypad will appear Press ‘Save’ move to next screen Press ‘Escape’ to exit WITHOUT changes saved

Fan Selection ‘New Fan’ - displays up to 32 fans that can be customised with calibration data‘New Fan’ - displays up to 32 fans that can be customised with calibration data Displays factory calibration parameters as per calibration reportDisplays factory calibration parameters as per calibration report ‘Edit Fan’ - ’ allows customisation of calibration details using ‘change and save’ buttons‘Edit Fan’ - ’ allows customisation of calibration details using ‘change and save’ buttons Use cursor buttons, ‘Save’, ‘Change’ and ‘Escape’ buttons as requiredUse cursor buttons, ‘Save’, ‘Change’ and ‘Escape’ buttons as required

Fan Calibration Formulae n < 0.99 V = n < n < 8.12 V = n n > 8.12 V = n Three Step Formula Two Step Formula n < 4.21 V = n n > 4.21 V = n Enter Data as: n < 4.21 V = n < n < 4.21 V = n n > 4.21 V = n One Step Formula All n V = n n < 5.00 V = n < n < 5.00 V = n n > 5.00 V = n Enter Data as Enter Data as :

Start New Gauging Select screen contrast, backlight and screen orientationSelect screen contrast, backlight and screen orientation Set display unitsSet display units Set discharge computation method (mean or mid-section)Set discharge computation method (mean or mid-section) Set clock to local timeSet clock to local time Check battery voltageCheck battery voltage Select siteSelect site

Enter Gauging Details Site name :Enter a 20 character alpha-numeric string. Time & Date:Automatically inserted when a discharge commences. Control:None / Checked / See Notes Method :Wading / Traveller / Cable / Boat / Bridge Rods:Top Set / Cable / Bottom Set Measure:Surface = 0 / Bed = 0 Staff Gauge:Enter gauge height when commencing measurements – optional. Weight Offset:Offset from weight to centre of Fan (Measurement point = Measured depth – Weight offset)

Enter Chainage / Sounding Details Type=WELB / Mid Stream / WERB #Points=Measurement points on this Vertical : 0,1,2,3,4,5,6,9,11 Staff: Enter Staff Gauge height – optional. Distance=Distance across the river from reference point to this vertical Dry Depth: Where applicable Wet Depth=Water Depth at this Vertical Wet Angle:Where applicable Wet Depth=Water Depth at this Vertical : Signifies ‘Optional’ = Signifies ‘Used in Mathematical Calculations’

‘Measure’ Function During Measurement – instantaneous velocityDuring Measurement – instantaneous velocity (averaged over the previous 5 seconds) After measurement – average velocityAfter measurement – average velocity (averaged over entire timing period)

Plot Function Allows operator to plot PART or ALL of the gauging sectionAllows operator to plot PART or ALL of the gauging section Displays ‘panel’ and ‘overall’ discharge for the gaugingDisplays ‘panel’ and ‘overall’ discharge for the gauging

Hydromate Interrogator Software Allows data to be uploaded from the Hydromate to a PCAllows data to be uploaded from the Hydromate to a PC Software loaded by inserting CD into PCSoftware loaded by inserting CD into PC Fan calibration details can be ‘set’ or ‘retrieved’Fan calibration details can be ‘set’ or ‘retrieved’ Gauging data can be downloaded in CSV formatGauging data can be downloaded in CSV format

Information Coding Discharge Data NameNumberDescription Control14None 15Checked 16See Notes Method7Wading 8Traveller 9Cable 10Boat 11Bridge Rods4Top Set 5Cable 6Bottom Set

Information Coding (cont.) Discharge Data NameNumberDescription Side19Up Stream 20Down Stream Measurement Type18Bed = 0 17Surface = 0 Units1m/s (metres per sec) 2ft/s (feet per second) 3km/day (km per day) Discharge Type1Mean Section 2Mid Section Factor24100% 5390% 2366% (2/3) 2250% (1/2) 2133% (1/3)

Information Coding (cont.) Discharge Data NameNumberDescription WE1WE-LB 2Mid Stream 3WE-RB DNotes25All OK 26Pylon Close 27Rock Upstream 28Debris 29Change Fan

‘Mean’ Section Method Q = v 1 *BF*(d 0+ d 1) + (v 1 + v 2 )*(d 1 + d 2 ) b 2 + (v 2 + v 3 )*(d 2 + d3) b 3 + etc “The total discharge (Q) is the product of the distance between verticals by the sum of the products of the mean of the depths of two adjacent verticals by the mean of the average velocities over those two verticals “ NB: Discharge within ‘panels’ near each bank is computed after selecting a ‘Bank Factor’ (BF) on the CMC3

‘Bank Panel’ Velocity Factor Applies to ‘Mean Section’ Method only The operator will need to make a judgement, based on his/her observation to determine a factor to apply to mean velocity measured in verticals closest to each bank and enter this factor into the CMC3, in EACH of the Water’s Edge verticals FactorComment 90%*Normally applied to bank panels of rectangular or square shape 66%Normally applied to triangular shape bank panels 50%Normally applied to triangular shape bank panels 33%Normally applied to triangular shape bank panels * Based on calculation from AS3778 Part 3.1 ‘Measurement of water flow in open channels’

‘Mid’ Section Method Total Discharge = V 1 d 1 ( b 1 + b 2 ) + V 2 d 2 ( b 2 + b 3) + V 3 d 3 ( b 3 + b 4 ) etc “The total discharge is the sum of the products of the average velocity in each vertical by the depth of that vertical and by the mean width of the two panels adjacent to the vertical “ This method assumes ‘zero’ velocity within ‘panels’ near each bank

Battery Replacement DO NOT TRY AND CHARGE STANDARD ALKALINE BATTERIES 1.Remove 6 screws on base of Hydromate 2.Remove electronics assembly 1.Remove batteries and replace with alkaline type 2.Use good quality ‘Energiser’ or ‘Duracell’ brand

Questions?